Loading...
HomeMy WebLinkAboutEvaluation ReportCREEK Certificate of Authorization No. Driv 17520 Edinburgh Drive Tampa, FL.33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, r EDITION (2014) Manufacturer: TAMKO BUILDING PRODUCTS, INC. P.O. Box 1404 Joplin, MO 64802 (417) 624-6644 http://wwwaamko:com Quality Assurance: UL LLC (QUA9625) SCOPE Issued August 22, 2016 _.,..�, � ���® OC T � 4 2017 Permitting De Lucie County FL Category: Roofing i Subcategory: Underlayments Code Sections: 1507.2.3, 1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5.1, 1507.4.5.2, 1507.4.5.3, 1507.53; 1507.5.3.2, 1507.6.3; 1507.6.3.2, 1507.6.5, 1507.7:3, 1507.7.3.2, 1507.8.3, 1507.8.3.2, 1507.8.8, T1507.8, 1507.9.3, 1507.9.3.2, 1507.9.5, 1507.9.9 Properties: Physical properties REFERENCES ED-till PRI Construction Materials Technologies (TST6049) Report No. TAPA91-02-01REV Standard Year co N FARENERS Oi ACHMENT, ",I�$�Y�PONSIBII�F PRI Construction Materials Technologies (TST6049) TAP-192-02-01 THE PRI Construction Materials Technologies (TST6049) TAP-193-02-01 PRI Construction Materials Technologies (TST6(49) TAP-214-02-01 ASTTOR OF PRI Construction Materials Technologies (TST6049) TAP-215-02-01 AST PRI Construction Materials Technologies (TST6049) TAP-216-02-03 ASTM D 6380 2003(2009) PRI Construction Materials Technologies (TST6049) TAP-217-02-01REV ASTM D 6380 2003(2009) PRI Construction Materials Technologies (TST6049) TAP-218-02-01 ASTM D 226 2006 PRI Construction Materials Technologies (TST6049) TAP-219-02-01 ASTM D 226 2006 PRI Construction Materials Technologies (TST6049) TAP-220-02-01 THE40RARSM ALL PR(g4JOW0VPAK PRI Construction Materials Technologies (TST6049) TAP-222-02-01 AREaFAft*4 8ANY CORBOMONS PRI Construction Materials Technologies (TST6049) TAP-319-02-01.1 RE08W611 +' FIELD INSPEaMS THAT UL LLC (TST9628) 13CA12269 MAY%Tft9ff§ARY IN ORS@Wr0 COMPLY WITH ALL APPLICABLE CODES. PRODUCT DESCRIPTION AND APPLICATION TAMKO® ASTM Slate ASTM D 6380, Class M, Type II underlayment constructed from organic felt saturated Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. f *7 ( 0- e 4 69 Min. slope: 2:12 ST. LUM CiDt'NTA' PUILD i DT1nA9T8ation:. The underlayment shall be installed with minimum 2" REVIEWED FOR C '1IPLIA,'CE � side laps and minimum 4" staggered end laps and in REVIE 1"i BY d accordance with FRSAITRI 07230 for tile DATE applications. PLANS ANDMUST BE KEPT ON JOB OR NO IN'SPECT1U-N WILL BE INLADk!lowable roof coverings: Attachment of asphalt shingle valleys and clay and concrete file .shall be permitted in accordance with the FBC. TBP14001.3 FL12328-R7 . Page 1 of 4 This evaluation report is:provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other prod ct attributes that are not specifically addressed herein.con_w j C R jj TAMKO BUILDING PRODCUTS, INC. j1 TAMKO Undertayments TECHNICAL SERVICES, LLC TAMKOO ASTM Tile ASTM D 6380, Class M, Type 11 underlayment constructed from an organic felt saturated Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules. Application: The underlayment shall be installed with minimum 2" side laps and minimum 4" staggered end laps and in accordance with FRSA/TRI 07230 for tile applications. Allowable roof coverings: Attachment of clay and concrete tile shall be permitted in accordance with the FBC. TAMKOO Master ASTM D 6380, Class S, Type IV underlayment constructed from an organic felt saturated Smooth with asphalt then coated on both sides with. asphalt and surfaced with a fine mineral. Application: The underlayment shall be installed along the valley in accordance with FBC requirements. Allowable roof coverings: Attachment of asphalt shingle: valleys shall be permitted in accordance with the FBC: TAMKOO Moisture Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane Guard Plus® with a mineral surfacing and a removable release film on the adhesive side.. Application: The underlayment shall be attached by adhering directly to the roof .deck. with minimum 3-1/2" side laps and minimum 6" staggered end laps. Min. application temperature: 40°F. Allowable roof coverings: Attachment of asphalt shingles and mechanically fastened concrete and. clay the roofing shall be permitted in accordance with the FBC. TAMKOO No. 15 ASTM ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4" end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TAMKOO No. 15 UL ASTM D 226, Type l underlayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4" end laps. Allowable roof coverings: Attachment of asphalt shingles; metal roofing, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TBP14001.3 FL12328-97 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changestor quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are 'not specifically addressed herein. i CREEK TAMKO BUILDING PRODCUTS, INC. TAMKO"Underlayments TECHNICAL SERVICES,, LLC TAMKOO No. 30 ASTM ASTM D 226, Type. If underlayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4 end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing; clay and concrete tile, slate shingles, wood shingles, wood shakes; and roll roofing shall be permitted in accordance with the FBC. TAMKO® No. 30 UL ASTM D 226; Type If underlayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4" end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing, clay and concrete file; slate shingles, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TAMKO® TIN Metal and Self -adhered, flexible,. ASTM D 1970, rubberized asphalt sheet membrane with a Tile Underlayment polymer film on the surface and a removable release film on the adhesive side. Application: The underlayment shall be attached by adhering directly to the roof deck with minimum 4" side taps and minimum 6" staggered end taps. Min. application temperature: 409F Allowable roof coverings: Attachment of asphalt shingles, metal roofing, and mechanically fastened clay and concrete tiles shall be permitted in accordance with the FBC. TAMKO®TW Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Underlayment polymer film on the surface and a removable release film on the adhesive side. Application: The underlayment shall be attached by adhering directly to the roof deck with minimum 4" side laps and minimum 6" staggered end laps. Min. application temperature: 40"F Allowable roof coverings: Attachment of asphalt shingles and metal roofing shall be permitted in accordance with the FBC. TAMKO® TAM -FELT Alternate to ASTM D 226, Type I and Type 'If underlayment constructed from a non - perforated organic felt that is saturated with asphalt. Application: The underlayment shall be installed with minimum 2" side laps and minimum 4" end laps: Allowable roof coverings: Attachment of asphalt shingles shall be permitted in accordance.with the FBC. TBP14001.3 FL12328-R7 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC ofany.product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or -other product attributes that are not specifically addressed herein. I/ CREEK TAMKO BUILDING PRODCUTS; INC. TAMKO Underlayments TECHNICAL SERVICES, LLC LIMITATIONS 1) This evaluation report is not for use in the HVHZ. 2) FireL Classification is not within the scope of this evaluation. 3) Wind uplift resistance in not within scope of this evaluation. 4) Installation of the evaluated product shall comply with this report, the FBC; and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5) Minimum application temperature shall be 500E unless otherwise noted. Contact the manufacturer when installing at temperatures below the minimum application temperature. 6) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 7) The roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be installed in accordance with FBC requirements. 8) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements. 9) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in successive courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 10) The underlayment may be used as described in other current FBC product approval documents. 11) The underlayment'shall not be installed over existing roof coverings. 12) Contact the manufacturer regarding specific exposure limits for each underlayment: 13) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 5`h Edition (2014) as -evidenced in the referenced documents submitted bythe named manufacturer. `,,`t���Y iR,IAr���i NSF• �Sj, �i No 74021 -'0 S TAT E OF : �W 0. rn CERTIFICATION OF INDEPENDENCE 2016.08.2 7-2 09:35:39 _0 /I,L001 Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical; Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by company manufacturing or distributing products under this evaluation. Zachary R. Priest,. P.E. does not have, nor will acquire, afinancial interest in any company manufacturing or distributing products under this evaluation. ZacharyR. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBP14001.3 FL12328-R7 Page 4 of 4 This evaluation report is.provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of -any product changes or quality assurance changes throughout -the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.