EVALUATION REPORT FLORIDA BUILDING CODE, r EDITION (2014)
Manufacturer: TAMKO BUILDING PRODUCTS, INC.
P.O. Box 1404
Joplin, MO 64802
(417) 624-6644
http://wwwaamko:com
Quality Assurance: UL LLC (QUA9625)
SCOPE
Issued August 22, 2016
_.,..�,
� ���®
OC T � 4 2017
Permitting De
Lucie County FL
Category: Roofing
i
Subcategory: Underlayments
Code Sections: 1507.2.3, 1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3,
1507.4.5.1, 1507.4.5.2, 1507.4.5.3,
1507.53; 1507.5.3.2, 1507.6.3; 1507.6.3.2, 1507.6.5, 1507.7:3, 1507.7.3.2, 1507.8.3,
1507.8.3.2, 1507.8.8, T1507.8,
1507.9.3, 1507.9.3.2, 1507.9.5, 1507.9.9
Properties: Physical properties
REFERENCES
ED-till
PRI Construction Materials Technologies (TST6049)
Report No.
TAPA91-02-01REV
Standard Year
co N FARENERS Oi ACHMENT,
",I�$�Y�PONSIBII�F
PRI Construction Materials Technologies (TST6049)
TAP-192-02-01
THE
PRI Construction Materials Technologies (TST6049)
TAP-193-02-01
PRI Construction Materials Technologies (TST6(49)
TAP-214-02-01
ASTTOR OF
PRI Construction Materials Technologies (TST6049)
TAP-215-02-01
AST
PRI Construction Materials Technologies (TST6049)
TAP-216-02-03
ASTM D 6380 2003(2009)
PRI Construction Materials Technologies (TST6049)
TAP-217-02-01REV
ASTM D 6380 2003(2009)
PRI Construction Materials Technologies (TST6049)
TAP-218-02-01
ASTM D 226 2006
PRI Construction Materials Technologies (TST6049)
TAP-219-02-01
ASTM D 226 2006
PRI Construction Materials Technologies (TST6049)
TAP-220-02-01
THE40RARSM ALL PR(g4JOW0VPAK
PRI Construction Materials Technologies (TST6049)
TAP-222-02-01
AREaFAft*4 8ANY CORBOMONS
PRI Construction Materials Technologies (TST6049)
TAP-319-02-01.1
RE08W611 +' FIELD INSPEaMS THAT
UL LLC (TST9628)
13CA12269
MAY%Tft9ff§ARY IN ORS@Wr0
COMPLY WITH ALL APPLICABLE CODES.
PRODUCT DESCRIPTION AND APPLICATION
TAMKO® ASTM Slate ASTM D 6380, Class M, Type II underlayment constructed from organic felt saturated
Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules.
f *7 ( 0- e 4 69 Min. slope: 2:12
ST. LUM CiDt'NTA' PUILD i DT1nA9T8ation:. The underlayment shall be installed with minimum 2"
REVIEWED FOR C '1IPLIA,'CE � side laps and minimum 4" staggered end laps and in
REVIE 1"i BY d accordance with FRSAITRI 07230 for tile
DATE applications.
PLANS ANDMUST BE KEPT ON JOB
OR NO IN'SPECT1U-N WILL BE INLADk!lowable roof coverings: Attachment of asphalt shingle valleys and clay and
concrete file .shall be permitted in accordance with
the FBC.
TBP14001.3 FL12328-R7 . Page 1 of 4
This evaluation report is:provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other prod ct attributes that are not
specifically addressed herein.con_w
j
C R jj TAMKO BUILDING PRODCUTS, INC.
j1 TAMKO Undertayments
TECHNICAL SERVICES, LLC
TAMKOO ASTM Tile ASTM D 6380, Class M, Type 11 underlayment constructed from an organic felt saturated
Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules.
Application:
The underlayment shall be installed with minimum 2"
side laps and minimum 4" staggered end laps and in
accordance with FRSA/TRI 07230 for tile
applications.
Allowable roof coverings:
Attachment of clay and concrete tile shall be
permitted in accordance with the FBC.
TAMKOO Master
ASTM D 6380, Class S, Type IV
underlayment constructed from an organic felt saturated
Smooth
with asphalt then coated on both sides with. asphalt and surfaced with a fine mineral.
Application:
The underlayment shall be installed along the valley
in accordance with FBC requirements.
Allowable roof coverings:
Attachment of asphalt shingle: valleys shall be
permitted in accordance with the FBC:
TAMKOO Moisture
Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard Plus®
with a mineral surfacing and a removable release film on the adhesive side..
Application:
The underlayment shall be attached by adhering
directly to the roof .deck. with minimum 3-1/2" side
laps and minimum 6" staggered end laps.
Min. application temperature:
40°F.
Allowable roof coverings:
Attachment of asphalt shingles and mechanically
fastened concrete and. clay the roofing shall be
permitted in accordance with the FBC.
TAMKOO No. 15 ASTM
ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
Application:
The underlayment shall be installed with minimum 2"
side laps and minimum 4" end laps.
Allowable roof coverings:
Attachment of asphalt shingles, metal roofing, wood
shingles, wood shakes, and roll roofing shall be
permitted in accordance with the FBC.
TAMKOO No. 15 UL
ASTM D 226, Type l underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
Application:
The underlayment shall be installed with minimum 2"
side laps and minimum 4" end laps.
Allowable roof coverings:
Attachment of asphalt shingles; metal roofing, wood
shingles, wood shakes, and roll roofing shall be
permitted in accordance with the FBC.
TBP14001.3 FL12328-97 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changestor quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are 'not
specifically addressed herein.
i
CREEK TAMKO BUILDING PRODCUTS, INC.
TAMKO"Underlayments
TECHNICAL SERVICES,, LLC
TAMKOO No. 30 ASTM ASTM D 226, Type. If underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
Application: The underlayment shall be installed with minimum 2"
side laps and minimum 4 end laps.
Allowable roof coverings: Attachment of asphalt shingles, metal roofing; clay
and concrete tile, slate shingles, wood shingles,
wood shakes; and roll roofing shall be permitted in
accordance with the FBC.
TAMKO® No. 30 UL ASTM D 226; Type If underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
Application:
The underlayment shall be installed with minimum 2"
side laps and minimum 4" end laps.
Allowable roof coverings:
Attachment of asphalt shingles, metal roofing, clay
and concrete file; slate shingles, wood shingles,
wood shakes, and roll roofing shall be permitted in
accordance with the FBC.
TAMKO® TIN Metal and
Self -adhered, flexible,. ASTM
D 1970, rubberized asphalt sheet membrane with a
Tile Underlayment
polymer film on the surface and
a removable release film on the adhesive side.
Application:
The underlayment shall be attached by adhering
directly to the roof deck with minimum 4" side taps
and minimum 6" staggered end taps.
Min. application temperature:
409F
Allowable roof coverings:
Attachment of asphalt shingles, metal roofing, and
mechanically fastened clay and concrete tiles shall
be permitted in accordance with the FBC.
TAMKO®TW
Self -adhered, flexible, ASTM
D 1970, rubberized asphalt sheet membrane with a
Underlayment
polymer film on the surface and
a removable release film on the adhesive side.
Application:
The underlayment shall be attached by adhering
directly to the roof deck with minimum 4" side laps
and minimum 6" staggered end laps.
Min. application temperature:
40"F
Allowable roof coverings:
Attachment of asphalt shingles and metal roofing
shall be permitted in accordance with the FBC.
TAMKO® TAM -FELT
Alternate to ASTM D 226, Type
I and Type 'If underlayment constructed from a non -
perforated organic felt that is saturated with asphalt.
Application:
The underlayment shall be installed with minimum 2"
side laps and minimum 4" end laps:
Allowable roof coverings:
Attachment of asphalt shingles shall be permitted in
accordance.with the FBC.
TBP14001.3 FL12328-R7 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC ofany.product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or -other product attributes that are not
specifically addressed herein.
I/
CREEK TAMKO BUILDING PRODCUTS; INC.
TAMKO Underlayments
TECHNICAL SERVICES, LLC
LIMITATIONS
1) This evaluation report is not for use in the HVHZ.
2) FireL Classification is not within the scope of this evaluation.
3) Wind uplift resistance in not within scope of this evaluation.
4) Installation of the evaluated product shall comply with this report, the FBC; and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
5) Minimum application temperature shall be 500E unless otherwise noted. Contact the manufacturer when
installing at temperatures below the minimum application temperature.
6) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
7) The roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck
shall be installed in accordance with FBC requirements.
8) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements.
9) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer's application instructions.
10) The underlayment may be used as described in other current FBC product approval documents.
11) The underlayment'shall not be installed over existing roof coverings.
12) Contact the manufacturer regarding specific exposure limits for each underlayment:
13) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 5`h Edition (2014) as -evidenced in the referenced documents submitted bythe named manufacturer.
`,,`t���Y iR,IAr���i
NSF• �Sj, �i
No 74021
-'0 S TAT E OF : �W
0.
rn
CERTIFICATION OF INDEPENDENCE
2016.08.2
7-2 09:35:39
_0 /I,L001
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical; Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by company manufacturing or distributing products under this evaluation.
Zachary R. Priest,. P.E. does not have, nor will acquire, afinancial interest in any company manufacturing or distributing products under this evaluation.
ZacharyR. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
TBP14001.3 FL12328-R7 Page 4 of 4
This evaluation report is.provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of -any product changes or quality assurance changes throughout -the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.