HomeMy WebLinkAboutProduct Approval Metal RoofingBCIS Home
Florida Building Code Online
rn I t1�
rim'.:.
Log In i User Registration l Hot Topics I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search
dDprFlorida
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail "ONCEALED FASTENERS OR ATTACHMEN
- ®FL # ng.V 63Y ARE THE RESPONSIBILITY OF THE
Application Type New CONTRACTOR OF RECORD
Code Version Ol
Application Status pprortved
. ;%>
Comments
Archived
Product Manufacturer Sunlast Metal /Wo a6Zs�-
Address/Phone/Email 2120 SW Poma Drive ST. LUC. COUNTY BC'Il ^Ltd p:`,1c1r4i�
Palm City, FL 34990
(772) 223-4055 REVIEWED FOR CO-NIPLIANCE
flvalidation@yahoo.com REVIE►JED BY G
DATE G /
Authorized Signature Terry Kapron PLANS A.ND PERMIT MUST HE KEPT ON J(
flvalidation@yahoo.com OR NO INSPECTION WILL BE .)LADE.
Technical Representative
Address/Phone/Email
Quality Assurance Representative THESE PLANS AND ALL PROPOSED WORK
Address/Phone/Email ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
Category Roofing COMPLY WITH ALL APPLICA569 CQDES.
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
a Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Locke Bowden
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 03/02/2026
Validated By Zachary R. Priest, P.E.
1 Validation Checklist - Hardcopy Received
Certificate of Independence FL19621 RO COI FL 17701 Sunlast Metal ssr.odf
Referenced Standard and Year (of Standard) Standard Year
TAS 100 1995
TAS 125 2000
TAS 125 2003
Equivalence of Product Standards
Certified By
Sections from the Code i
https://www.floddabuilding.org/pr/pr app_otl.aspx?param=wGEVXQwtDgtA°/a2fGGFsMxvHNQgk6GRNt8kduX9Ye74PcXH17°/a2bti8c9lg°/a3d%3d 1/2
7/17/2017
` Product Approval Method
Florida Building Code Online
Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
12/18/2015
12/18/2015
12/21/2015
02/10/2016
FL #
Model, Number or Name
Description
ff62
"'Key Seriesi?5 V Crimp HVHZ
26^GA ,HVHZ -24''width
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL19621 RO II FL 17701 Sunlast Metal ssr.Ddf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. # 49704
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +n/a/-189.25
Evaluation Reports
Other:-78.5psf @ 16" o.c.-189.25psf @ 8" o.c. Install per
FL19621 RO AE FL 17701 Sunlast Metal ssrodf
manufacturer instructions and RAS 133 in compliance with FBC
Created by Independent Third Party: Yes
2014 For HVHZ use
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1024
The State of Florida is an AA/EEO employer. _Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
W. E M
Predit.Catd
securityNil-TKICS'
https://www.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtAg/g2fGGFsMxvHNQgk6GRNt8kduX9Ye74PcXH17p/o2bti8cglgg/p3dg/g3d 2/2
10
Locke.Bowden, P.E.
9450 Alysbury Place
Montgomery, AL 36117
Manufacturer: Sunlast Metal, Inc.
2120 SW Poma Drive
Palm City, FL 34990
Code Compliance. Flo da°Building Code 301
Rule # 61G20-3
Category: Roofing
Sub -Category Metal Roofing HVHZ
"Key=West°Se'ries"
Product: 5V Crimp Metal Roof Panel
FL 17701
Support Substrate: 15/32" APA Wood Deck min. over supports at 24" spacing maximum
Material 26GA steel Yield Strength 55ksi min. Corrosion resistant: Material to comply with FBC
section 1517.6 for HVHZ (Design of support system not included in this report)
Panel Dimensions: Thickness-26GA steel Width: 24" Rib Height: 5/8" High rib: 12' o.c
Slope: 2/12 min. or greater in compliance with FBC 2014; Section 1515.2
Underlayment: In conformance to FBC 2014.
Fire Classification: Not within the scope of this report.
Fastener: Corrosion resistant #10-1-1/2" (3/16" min. penetration through support; Wood-Zac
XG Fastener, Hex Head w/Neoprene washer fastener or equivalent In compliance with FBC
Section 1506.6 and 1507.4.4
Insulation: Optional -Rigid insulation board, 3" max thickness compliant with FBC 2014 Section
1508.2
Installation: Install per manufactures details and RAS 133
(Deslg"0Il1W�Pressure; Table A1ij
Roof�Areas w'�G
�Fie(d _
'n•.
E P."eLimeteistand Corners
MaD�esign Pressure.
-78.5 psf
-189.25 psf
FastenerSpacmg
16" o.c.
8" o.c.
Fasterie� Size ' t:.
#10
#10
*Maximum Design Pressures include 2J Safety Factor
Quality Assurance: In accordance with FBC 2014 and Rule # 61G20-3: Keystone Certification,
Inc. QUA 1824
Code Compliance demonstrated: Florida Building Code 2014 Section 1523.6.5.2.4.1
This report is limited to compliance with the structural wind load requirements of the FBC 2014.
Required wind loads shall be determined per project per FBC 2014 and any rational analysis
computation shall be prepared by a licensed design professional.
Reference Data:
Architectural Testing Inc (TST 1527) #F0755.01-450-18
Architectural Testing Inc (TST 1527) #0412-1017-05
Architectural Testing Inc. (TST 1527) #SFMS-001-02-01
PRI Construction Material Technologies(TST5878) AKZC-001-02-01/05
PRI Construction Material, Tech nologies(TST5 878)AKZC-001-02-01/05
AKZO Nobel Coatings, Inc.
Lab Form
TAS 125-2003
TAS 125-2003
TAS 100-1995
TAS 110-2000
ASTM B 117-2002
ASTM G 153
Locke Bowden, P.E.
9450 Alysbury Place
Montgomery, AL 36117
Manufacturer: Sunlast Metal, Inc. FL 17701
2120 SW Poma Drive
Palm City, FL 34990
Certificate of Independence
Locke Bowden, P.E. does not have, not will: acquire financial interest in any company manufacturing or
distributing products under this evaluation..
Locke Bowden, P.E. is not owned, operated or controlled by any company manufacturing or
distributing products under this report.
Perimeter/'Corner'fastenebspaang:8' o e "T e-d. astener spacing
a
Swe Table 'A'
o # 4W
r `
0VWWP AP
�0111 in.rrrrrrr.
80
�/
V a
L&ke Bowden,
F6A 044 STATE OF °
ate.
i s
!�'l�4eM