Engineering Installation Methods
FL #: FL 17022.6 R5 Date: 4 / 18 / 16 NC.E3UCK Engineering Page Report No.: 6 of INS-A36W-ER SpPclalty Structural Engineaprinq CBUCK, Inc. Certificate of Authorization #8064 Installation Method Extreme Metal Fabricators, LLC. 1" Nail Strip (0.032" Aluminum) Roof Panel attached to Wood Deck Drawings 16" 0-1 Panel Profile . . }:'A i M COPY � \ XIIIN �� X 3/4" 1 Deck: -15/32" or greater Plywood, or - Wood plank Integral Snap Lock Apply 3116" Bead Bostik 915TM Sealant ContinuousAlong Male Rib Vertical Flange Fastener #10 x 1" Min. per Table "A" Pancake Head Wood Screw Typical Assembly Profile View (Typical Fastening Pattern Across Width) FL #: FL 17022.6 R5 Date: 4 / 18 / 16 N. CBUCK Engineering Page Report No.: 1 off-1NS-A36W-ER Spxlalty Structural Englneerinq CBUCK, Inc. Certificate of Authorization #8064 Installation Method Extreme Metal Fabricators, LLC. 1" Nail Strip (0.032" Aluminum) Roof Panel attached to Wood Deck Fastener #10 X 1" Min. per Table "A" Pancake Head Wood Screw 1" Nail Strip Roof Panel Optional: Rigid Insulation Thickness 3" Maximum L Seam Adhesive Application: Deck: Apply 3116" Bead Bostik 915Tm Sealant 15/32" or greater Plywood, or Continuous Along Male Rib Vertical Flange - Wood plank (Refer to Table "A") Typical Roof Assembly Isometric View (Optional) Rigid Insulation Board per Page 4 of this report TABLE "A" ALLOWABLE LOADS METHOD 1 Design Pressure (ASD)*: - 78.5 PSF Fastener Spacing: 6" o.c. Seam Adhesive: 3/16" Continuous Bead * Allowable design pressure(s) for allowable stress design (ASD) with a margin of safety of 2 to 1.