HomeMy WebLinkAboutLetter- Permit 1711-0075,. SUMMIT
DESIGN & FORE.N''SICS, INC..
August 20, 2018
RE: Nicole & Bradley Beddome
2365 Dyer Road
Port St. Lucie, Florida 34952
Permit No.: 1711-0075
Attention: Inspector,
It is acceptable to fasten the lath at the stucco ceilings and soffits with minimum 11 gage,
2" long and 3/8" head nails spaced at 6" on -center.
If you should have any questions, please call me at 772-285-0572.
Respectfully Submitted,
Brian J. Maskol, P.E.
Summit Design & Forensics, Inc.
State of Florida
License No. 66080
SUMMIT
DESIGN & FORENSICS:, INC..
August 21, 2018
RE: Nicole & Bradley Beddome
2365 Dyer Road
Port St. Lucie, Florida 34952
Permit No.: 1711-0075
Attention: Inspector,
It is acceptable to attach the (2)-2xl2 beam to the wood post using (2)-MTS20 straps in
lieu of the specified LUS410.
It is our understanding that the specified connector has been added for the 6x6 corner
post to (2)-2x12 beam. In addition, (2)-MST24 straps have been used at this connection.
Blocking and nailing per plan has been added for the wall sheathing.
If you should have any questions, please call me at 772-285-0572.
Respectfully Submitted,
Brian J. Maskol, P.E.
Summit Design & Forensics, Inc.
State of Florida
License No. 66080