Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Review - Comments
to Planning& Development Services REVIEW COMMENTS EC 1Lt�A Building & Code Regulation Division , 2300 Virginia Avenue Fort Pierce, FL. 34982 f ��n� CO St. Lucie C . Phone:(772)462-2172 Fax:(772)462-6443 Page 1 PROPERTY INFORMATION Address: 2365 Dyer Rd City / State / Zip: Port St Lucie, FI 34952 Parcel #: 3414-501-1409-350/0 Zoning: APPLICATION INFORMATION Permit Number: 1711-0075 Owner(s): Bradley R Beddome / Nicole D Beddome Jurisdiction: SAINT LUCIE COUNTY Lot#: 9 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Michael J Miranda J, CA Block: 2 Automatic Sprinkler System? No k Fax Number: 772-334-0804 Business Name: Group One Construction & Dev Inc Business Addr: 10302 S Federal Hwy Ste 164 Email: Mikemiranda3074@Aol.Co ©`` m City / State / Zip: Port St Lucie, FI 34952 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released ADDRESSING ASSIGNMENT COMPLETE Lydia Galbraith 11/13/2017 11/1412017 11/14/2017 Comment: DOCUMENTS MISSING 11/2/2017 Comment: 11/13/2017 Comment: 11/13/2017 Comment: ENVIRONMENTAL REVIEW Comment: FRONT COUNTER REVIEW Comment: PLANS EXAMINER REVIEW Comment: PENDING Lashahna Ingram NEED SUB CONTRACTOR AGREEMENTS FOR ALL TRADES A COPY OF THE PAID UTILITY SERVICE RECEIPT FOR ELECTRIC SERVICE OR A LETTER FROM THE ELECTRICAL UTILITY PROVIDER THAT ELECTRIC WILL BE AVAILABLE TO THE LOCATION. APPLICATION IS MISSING A JOB DESCRIPTION. PLEASE ADD AT TIME OF PICK UP COMPLETE Lynn Swartzel 11/6/2017 11122/2017 11/22/2017 COMPLETE PENDING Lashahna Ingram 11/2/2017 11/2/2017 11/2/2017 ZONING REVIEW INCOMPLETE Lydia Galbraith 11/812017 11 8/2017 Comment: PLEASE PROVIDE A COPY OF THE €CORDED ACCESS EASEMENT. Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462-6443 REVIEW COMMENTS Page 2 Comment: THE SURVEY IS INCOMPLETE: PLEASE INDICATE THE CORRECT SCALE ON PAGE 2, THIS PAGE DOESN'T SCALE 11`— 60'. DIMENSIONS ON THE SURVEY ARE NOT MATCHING WITH THE FLOOR PLAN (GARAGE AND REAR,P( 11/8/2017 - INDICATE PROPOSED FINISHED FLOOR, ELEVATION. MIN -REQUIRED IS 18" ABOVE CENTER LINE,OF SIN THIS CASE18"ABOVE BENCH MARK ELEVATION 15.21'OR"ELEVATION REQURED FOR SEPTI" ANKIDIAIN FIELD) -SETBACK FROM'�PROPOSEO SFR TO ALL PROPERTY LINES. 11/13/2017 Comment: FLOOR PLAN INDICATE BEDROOM 4. HOWEVER, WE.COUNT A TOTAL OF 3 BEDROOMS1 Comment PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING RE' EW. THE PLANS 11/14/2017 EXAMINER MIGHT HAVE ADDITIONAL CO'MME{yyT5 y =�, .5�owt� o> r Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462-6443 REVIEW COMMENTS Comment: - THE SUBMITTED ATTACHMENT METHOD FOR THE PRODUCT APPROVAL AFFIDAVIT ON THE PLANS IS NOT COMPLETE. IF THE ATTACHMENT METHOD IS NOT COMPLETE IN ITS ENTIRETY FOR THE PRODUCT SPECIFIED ON THE PRODUCT APPROVAL AFFIDAVIT, THE PRODUCT APPROVALS MUST BE SUBMITTED AND HIGHLIGHTED SHOWING THE ATTACHMENT METHOD. 12/26/2017 • SUBMIT THE PRODUCT APPROVALS, IN DUPLICATE OR PRODUCT REVIEW AFFIDAVIT COMPLETE WITH FLORIDA PRODUCT APPROVAL OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED SEALED AND DATED BY THE DESIGN PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN ACCORDANCE WITH 553.842 OF THE FLORIDA STATUTES. PRODUCT APPROVAL'S MUST BE HIGHLIGHTED OR MARKED IDENTIFYING THE OPENING OR CLADDING COMPONENTS, WITH FASTENERS AND DESIGN PRESSURES. Comment: • PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING 12/26/2017 THE SQUARE FOOT INFORMATION OR A LETTER FROM THE DESIGN PROFESSIONAL SPECIFYING THE CUBIC VOLUME OF THE CONDITIONED SPACE. SEE CHAPTER 1 SECTION 107 OF THE 2014 FLORIDA BUILDING CODE. 12/26/2017 Comment: - ENERGY CALC'S INFORMATION BLOCK AT THE TOP OF THE PAGE ARE INCOMEPLETE. SEE SECTION 405.4.2 (1) OF THE 2014 FLORIDA ENERGY CODE. ZONING REVIEW INCOMPLETE Lydia Galbraith 11/8/2017 11/8/2017 Comment: PLEASE PROVIDE A COPY OF THE RECORDED ACCESS EASEMENT. Comment: THE SURVEY IS INCOMPLETE: - PLEASE INDICATE THE CORRECT SCALE ON PAGE 2, THIS PAGE DOESN'T SCALE 1"= 60'. 12/6/17 NOT ADDRESSED. SCALE STILL INDICATES 1"=60' 12/21/17 ADDRESSED - DIMENSIONS ON THE SURVEY ARE NOT MATCHING WITH THE FLOOR PLAN (GARAGE AND REAR PORCH) 12/6/17 NOT ADDRESSES, STILL NOT MATCHING. SEE FOUNDATION PLAN AS WELL. PORCH IS LARGER ON THE SURVEY THAN ON THE FOUNDATION/FLOOR PLANS. GARAGE IS LARGER ON THE SURVEY THAN ON 11/8/2017 PLANS. - INDICATE PROPOSED FINISHED FLOOR ELEVATION. MIN. REQUIRED IS 18" ABOVE CENTER LINE OF ROAD (IN THIS CASE 18" ABOVE BENCH MARK ELEVATION 15.21 OR ELEVATION REQUIRED FOR SEPTIC TANK/DRAIN FIELD) 12/6/17 CORRECTED. - SETBACK FROM PROPOSED SFR TO ALL PROPERTY LINES. 12/6/17 NOT ADDRESSED. 12/21/17 ADDRESSED. 11/13/2017 Comment: FLOOR PLAN INDICATE BEDROOM 4. HOWEVER, WE COUNT A TOTAL OF 3 BEDROOMS. 11/14/2017 Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.