HomeMy WebLinkAboutPool Layout & Piping PlanPOOL CONTRACTOR TO VERIFY ALL PROPERTY LINE LOCATIONS AND POOL ELEVATION PRIOR TO CONSTRUCTION. POOL LAYOUT AND DIMENSIONS TO BE VERIFIED W/ OWNER PRIOR TO CONSTRUCTION EX, RESIDENCE POOL PILING PLAN SCALE: 1/4"=1'-0" PILE TO BE PLACED ON 15 ANGLE OUTWARD FROM BOTTOM OF POOL SHELL - TYP. 2 PLACES AS SHOWN EXISTING 48" MIN. HIGH RAIL WITH SELF LATCHING GATE WHAT SWINGS OUT AWAY FROM POOL AREA VERIFY EXIST. FENCE IN COMPLIANCE W/ CHILD SAFETY BARRIER REQUIREMENTS PER FBC FIFTH EDITION (2014) NOV 0 0 2017 Permi':tinq Department St. Lucie County, FL 71-611 t 25- 7'-6►► ----------------------- - - - - - i 2.5" SCH 40 r-- 3_SCH 0 _._ I I ----4 NOTE: PROVIDE WINDOW AND DOOR ALARMS ON ALL OPENINGS THAT LEAD ONTO POOL AREA PER CODE EX. RESIDENCE POOL LAYOUT & PIPING PLAN SCALE: 1/4"=1'-0" POOL EQUIPMENT UNDER DECK POOL/SPA EQUIP. SEE SITE PLAN REINFORCED OR PRODUCT APPROVED CONCRETE SLAB(S) (FIELD VERIFY SIZE & LOCATION) S;. LtiCT rnl� aITI n, nn Tc, RTFVIEl3 ED FOR COMPLIANCE DATE 'I -- PL.'NS AND PERMIT MUST BE KEP"f 0 Oil NO INSPECTION WILL BE MADE. THESE PLANS AND ALL PROPOSED Wl APE E,UBJLCT TO ANY CORRECTIONS RtoUIPEO By FIELD INSPECTORS THI MAY RE NECESSARY IN ORDER TO toMPLY WITH ALL APPLICABLE CODI No LL�.� Cj co 0 0� m w [teZ< 0 r, 0 „ O� a O w e1 en TrO!LA V1 V a 0000 �a 00 DRAWN BY: MAP CHECKED BY: WJC DATE: 7-18-17 SCALE: AS NOTED JOB NUMBER: 17 - 287 SHEET OF 3 0 U rEu'W 1 t> 7 f— DECK - BY OTHERS X 20.5' N.A.V.D. #4 DIA. REBAR @ 12" O.C.E.W. PILING STEEL TO BE BENT INTO POOL FLOOR AND TIED TO \� TOP MAT OF STEEL 16.0' N.A.V.D. PILING NOTES: -RECESS PILING 3" INTO BOTTOM OF POOL FLOOR (TYP.) 81 -PILE REINFORCING (NOT SHOWN) IS TO BE SPECIFIED BY PILING ENGINEER - PILING STEEL TO BE BENT INTO POOL FLOOR AND TIED TO TOP MAT OF STEEL DECK - BY OTHERS #4 DIA. REBAR @ 12" O.C.E.W. - 16.0' PILE EXTENSION 8 1 SEE DETAIL 14" DIA. AUGER CAST PILE (8 REQUIRED) 15 TON DESIGN CAPACITY 30 TON ULTIMATE CAPACITY 6" rr 8" 4'-8"7 2' lg STEP BEYOND 1" Ti 6" I 12" 10" 1,. #4 DIA. REBAR / #4 DIA. REBAR @ 12" O.C.E.W. BOTTOM MAT 1s" @ 6" O.C.E.W. TOP MAT PILE EXTENSION I / SEE DETAIL 1 #4 DIA. REBAR @ 12" O.C.E.W. BOTTOM MAT 14" DIA. AUGER CAST PILE (8 REQUIRED) 15 TON DESIGN CAPACITY 30 TON ULTIMATE CAPACITY F.3m #4 DIA. REBAR @ 6" O.C.E.W. IN VANISHING EDGE WALL AND PIT RECESS PILING 3" INTO BOTTOM OF POOLFLOOR (TYP.) POOL/SPA/ AND VANISHING EDGE SECTION 94 DIA. REBAR #4 DIA. REBAR @ 12" O.C.E.W. BOTTOM MAT SCALE: 3/8" = V-0" 25' 20' 10' SLOPE 1' POOL SECTION TYPE 'O' POOL SCALE: 3/8" = V-0" 5' 4'-111, 6" 20.5' N.A.V.D. ' RECESS PILING 3" 6 INTO BOTTOM OF POOLFLOOR (TYP.) 8.0' N.A.V.D. ' 1 / t 18" 8t -0 #3 DIA. HOOPS @ 16" O.C. IN. M Ztt 2t� DECK - BY OTHERS 18" X 18" SQUARE W/ 5000 P.S.I. CONC. (4) #5 DIA. REBAR TIED INTO EXIST. PILING STEEL W/ 36" LAP EXISTING ^ PILING ' �J PILE EXTENSION DETAIL 14" 1/2" = i' — 0" DECK -BY OTHERS' 6" 4' #4 ]DIA. REBAR @ 12" O.C.E.W. BOTTOM MAT SUN SHELF SECTION SCALE:1/2" 1'-0" #4 DIA. REBAR @ 6" O.C.E.W. 10.5" #4 DIA. REBAR @ 6" O.C.E.W. i TOP MAT DRAWN BY: MAP CHECKED BY: WJC DATE: 4-18-17 SCALE: a AS NOTED JOB NUMBER: 17 - 287 SHEET Aft 2 OF 3 18" MIN: 24" MAX. 11 DECK -BY OTHERS (ENTIRE PERIMETER) - 14 HEATER (GAS) - IGNAITIONSWITCH WATER LINE 3 - 812 THHN CU WITHIN 1/2" CONDUIT BULLNOSE 3 BRICK COPING @ , S �' POOL PANEL W/ 80 ADSY BRKR & MANUAL MOTOR STARTER SWITCH SLOPE DECK / PER. FOOT w PIPE REDUCED TO 1" 2.7 HP JANDY E-PUMP MOTOR w/ BUILT-IN 4 z w AND RUN TO DECK T - N & (2) #10 GND j #8 SOLID BARE COPPER BOND 6 3 - OVERLOAD SWITCH W/ 3 - #10 THHN CU �. < sox THHN CU IN WIRE w/ APPR. CLAnIPS 1 1/4" RPVC CONDUIT WITHIN Y," MIN. CONDUIT (ONE ON LEACH SIDE OF `o (G E PROTECTED) POOL-4TOTAL) c 1 VACUUM FITTING W/ W P CLOCK IONNECT y F�5 2" SCH 40 PVC CORD SELF -CLOSING SAFETY COVER S.P.S.T. To S + LED LIGHT SLEEVE SWITCH 6" THICK CONCRETE SLAB(BY OTHERS) (HAYWARD MODEL #400L 12 VOLT TRANSFORMER 6" W/ (1) #8 BARE SOLID COPPER IVIRE SP 10-22 WALL OR EQUAL) (2) POOL LIGHTS 41 (IN SLAB) BONDED TO POOL FITTING - ORE UAL GFI NOT REQUIRED) y' STEEL AS SHOWN Q ( Q ) JUNCTION BOX MARCITE INSTALLED INSIDE PIPE VACUUM LINE DETAIL OR EQUAL (1) SPA LIGHT REINFORCING STEEL EQUIPOTENTIAL BONDING DETAIL (WHEN APPLICABLE)( GFI NOT REQUIRED) (SEE SHEET 2) PER FLORIDA BUILDING CODE ADAPTATION OF 12'T ' ",I N.E.C.2011 SEC.680.26 LED LIGHT DETAIL I. ALL ELECTRICAL 1'O COMPLY WITH 2O11 NATIONAL ELECTRIC CODE. RADIIUS ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY VARIES AT POINT OF CONNECTION. TYPICAL WALL SECTION 2. 3-412 THHN CU WITHIN 1/2" MIN. CONDUIT FOR POOL LID. ID, BAR 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC. w/ #8 SOLID, BARE COPPER. 4. PROVIDE W.P.G.F.I. OUTLET 10' MIN. - 20' MAX. FROM WATER'S EDGE. 5. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(B). 12" . 12". 12" 10.5" 10.5" 1 10.5" 10.5"� -'1_' Tom. • T STEP SECTION POOL/SPA SPECIFICATIONS SIZE: 13'-8" X 25' DEPTH: Y-0" TO 4'-11" VOLUME: 10,066 GALLONS ELEVATION DET. ON SITE TURN OVER RATE: 4.66 HR. (a), 36 GPM MAX. - LOW SPEED (TURN OVER RATE: 1.27 HR. (a, 132 GPM - HIGH SPEED) DESIGN FLOW RATE = 10,066 GAL./6 HRS./60 MIN. = 28 G.P.M. TILE: STANDARD THERAPY JETS: (6) IN SPA POOL FINISH: MARCITE OR EQUAL PIPING: SCH. 40 INLETS POOL 3 SPA (THRU JETS) DECK: PAVERS ELECTRIC: BY OTHERS POOL LIGHT: (2) LED SPA: LED LADDER: NO HANDRAIL: NO REC. PUMP: 2.7 HP JANDY E-PUMP JEP 2.0 A.P.S.P. PUMP CERT.: CURVE A - 34 GPM (a-,) 1725 RPM FILTER: JANDY CS200 CARTRIDGE - 200 SQ. FT. FILTER AREA HEATER: JANDY 400,000 BTU GAS HEATER VACUUM LINE: YES POOL AREA: 298 S.F. PERIMETER 77 L.F. SPA AREA: 35 S.F. PERIMETER 24 L.F. PIT AREA: 50 S.F. PERIMETER 54 L.F. AUTO -FILL: YES OVERFLOW: YES JANDY AQUALINK W/ SPA SIDE REMOTL ELECTRICAL DIAGRAM N.T.S. AQUASTAR 32CDFL - 32" -�c CHANNEL DRAIN (316 GPM @ 3.9 FT/SEC THRU GRATE - SINGLE UNBLOCKABLE OR EQUAL 3 FINISH PLASTER ' -� HYDROSTATIC RELIEF VALVE & PERFORATED PVC COLLECTION TUBE, WHERE REQUIRED 32" - � r 3 3/32" HYDROSTATIC RELIEF VALVE PORT OR CAP OFF FLOOR MAIN DRAIN SUCTION LINE TIED TOGETHER AS SHOWN ABOVE - PIPE SIZE PER PLAN MIN. %2 YARD GRAVEL SUMP NOTE: 25.9 SQUARE INCII OPEN AREA, WRAPPED W/ DRAIN FEILD 316 GPM = 3.9 FEET PER SECOND CLOTH (RECOMMENDED) Channel Main Drain Detail SCALE: 3/8" = F-0" n EQUIPMENT LAYOUT SCALE: N.T.S. PUMP FRAME OR FILTER TANK MOUNT OR HEATER /ANCHORPOOLPUMPAND /FILTER PER MFGR'S. N.O.A. 4" THICK REINFORCED CONCRETE SLAB -71�2MIN. F.G. urmnn _ FILTER POOL PUMP, FILTER " AND HEATER ANCHOR POINTS MAY VARY HEATER POOL EQUIPMENT ANCHORING DETAIL SEE MFGR. SPECIFICATIONS FOR ADDITIONAL ANCHORING INFORMATION - EQUIPMENT SHAPES MAY VARY LEGEND 1. 3" SPA MAIN DRAIN LINE 2.2" VACUUM LINE 3. 3" POOL MAIN DRAIN LINE 4.2" SKIMMER LINE 5. 3" POOL RETURN LINE 6.3" RETURN TO SPA JETS A. 2.7 HP JANDY E-PUMP JEP 2.0 REC. PUMP W/ APPR HAIR & LINT STRAINER B. CARTRIDGE FILTER W/ PRESSURE GAUGE AND AIR RELIEF VALVE C. 1.5" TO WASTE OR DISCHARGE TO GROUND D. JANDY 400,000 BTU GAS HEATER W/ INTERNAL BY-PASS E. VALVES (TYPICAL) GENERAL NOTES: �1. ALL LIGHTS, LADDERS, HANDRAILS, REINFORCING STEEL SHALL BE GROUNDED PER CODE. 2. POOL TO BE CONSTRUCTED OF CONCRETE/GUNITE WITH A MINIMUM COMPRESSIVE STRENGTH OF 4000 P.S.I. AT 28 DAYS. 3. ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OF NEW BILLET STEEL, CONFORMING TO ASTM A-615, GRADE 60, STEEL SHALL BE BENT, LAPPED AND PLACED IN ACCORDANCE WITH ACI STANDARDS. 4. GRATE IN MAIN DRAIN SHALL HAVE A FREE AREA OF 4 TIMES THE AREA OF THE SUCTION LINE. 5. STEPS TO HAVE A 10" MINIMUM TREAD AND A 12" MAXIMUM RISER. 6. POOL TO BE FENCED PER LOCAL CODES. 7. GATES TO BE SELF -LATCHING, SELF -CLOSING AND LOCKABLE. 8. DESIGN, CONSTRUCTION AND WORKMANSHIP SHALL BE IN CONFORMITY WITH THE REQUIREMENTS OF ANSI/ NSPI 3; ANSI/ NSPI 4; ANSI/ NSPI 5; ANSI/ NSPI 6; AND ANSI/APSP 7 2006 AND ANSI/APSP.ICC-15 2011. 9. SPAS AND HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH A COVER DESIGNED TO MINIMIZE HEAT LOSS. EXCEPTIONS: OUTDOOR POOLS DERIVING OVER 70 PERCENT OF THE ENERGY FOR HEATING FROM NON-DEPLETABLE ON -SITE RECOVERED SOURCES COMPUTED OVER AN OPERATING SEASON ARE EXEMPT FROM THIS REQUIREMENT. 10. ALL FEATURES OF THE POOL/SPA SHALL BE INSTALLED IN COMPLIANCE WITH THE FBC FIFTH EDITION (2014) - RESIDENTIAL, SECTION R4101-PRIVATE SWIMMING POOL AND LOCAL AMENDMENTS, IF ANY. il. RESIDENTIAL SWIMMING POOL BARRIER SHALL COMPLY WITH FBC FIFTH EDITION (2014) - RESIDENTIAL CHAPTER 45 - PRIVATE SWIMMING POOL. 12. POOL CONTRACTOR/OWNER BUILDERS TO VERIFY ALL POOL DIMENSIONS, POOL LOCATION AND SETBACKS PRIOR TO CONSTRUCTION. (CONTACT ENGINEER IF ANY DISCREPANCIES OCCUR) 13. POOL PLANS ARE DESIGNED TO MEET THE FBC FIFTH EDITION (2014) - RESIDENTIAL - PRIVATE SWIMMING POOLS. 14. ENTRAPMENT PROTECTION FOR SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ANSI/APSP 7-2006 AND FBC FIFTH EDITION (2014) - RESIDENTIAL CHAPTER 45. PLUMBING NOTES: 1. ALL PIPING, EQUIPMENT AND MATERIALS USED IN THE PLUMBING SYSTEM OF SWIMMING POOLS THAT ARE BUILT IN PLACE SHALL CONFORM TO THE FBC FIFTH EDITION (2014), PLUMBING, CHAPTER 45 - PRIVATE SWIMMING POOLS.POOL PIPING SHALL BE DESIGNED SO THE WATER VELOCITY WILL NOT EXCEED 6 FT/SEC ON BRANCH SUCTION LINES, 8 FT/SEC. ON SUCTION LINES AND 10 FT/SEC. PRESSURE LINES. 2. VALVES SHALL BE MADE OF MATERIALS THAT ARE APPROVED IN THE FLORIDA BUILDING CODE, PLUMBING. VALVES LOCATED UNDER CONCRETE SLABS SHALL BE SET IN A PIT HAVING AT LEAST A DIMENSION OF FIVE DIAMETERS WITH A MINIMUM OF AT LEAST 10 INCHES AND FITTED WITH A SUITABLE COVER. ALL VALVES SHALL BE LOCATED WHERE THEY WILL BE READILY ACCESSIBLE FOR MAINTENANCE AND REMOVAL. 3. WHERE CHECK VALVES ARE INSTALLED, THEY SHALL BE OF THE SWING OR VERTICAL CHECK PATTERN. 4. ALL HEATERS SHALL BE EQUIPPED WITH AN APPROVED PERMANENT BY-PASS OR ANTI -SIPHON DEVICE INSTALLED TO PROVIDE A POSITIVE MEANS OF RETAINING WATER IN THE HEATER WHEN THE PUMP IS NOT IN OPERATION. 5. ALL POOL PIPING SHALL BE: 1.5" SCH. 40 PVC EXCEPT AS SHOWN AND SHALL BEAR THE H.S.P. SEAL OF APPROVAL. 6. THIS POOL/SPA IS DESIGNED TO WITHSTAND HYDROSTATIC UPLIFT FORCES WHEN EMPTY, FOR WATER TABLE UP TO X-0" BELOW POOL/SPA DECK ELEVATION. HOWEVER, DUE TO SEASONAL VARIATIONS IN THE WATER TABLE ELEVATIONS, ALL POOL/SPA SHALL BE FITTED WITH A HYDROSTATIC RELIEF VALVE. 7. WATER SUPPLY AND DISPOSAL SHALL BE ARRANGED SO THERE IS NO CROSS .SUCTION WITH A DOMESTIC WATER SUPPLY OF WATER DISPOSAL. 8. UNLESS AN APPROVED TYPE OF FILLING SYSTEM IS INSTALLED, ANY WATER SUPPLY WHICH IN THE JUDGEMENT OF THE ADMINISTRATIVE AUTHORITY MAY BE USED TO FILL THE, POOL IF EQUIPPED WITH BACKFLOW PROTECTION. NO OVER -THE -RIM FILL SPOUT WILL BE ACCEPTED UNLESS LOCATED UNDER A DIVING BOARD, OR PROPERLY GUARDED. 9. ALL POOL/SPA PIPING SHA"LL BE INSPECTED AND APPROVED BEFORE COVERING OR CONCEALING. IT SHALL BE TESTED AND PROVED TIGHT TO THE SATISFACTION OF THE ADMINISTRATIVE AUTHORITY, UNDER A STATIC WATER TEST OR AIR PRESSURE TEST OF NOT LESS THAN 35 PSI FOR 15 MINUTES. 10. JOINTS AND CONNECTIONS SHALL BE MADE AS REQUIRED BY THE FLORIDA BUILDING CODE, PLUMBING. 14. ALL WATER HEATING EQUIPMENT SHALL BE INSTALLED WITH FLANGES OR UNION CONNECTION ADJACENT TO THE HEATER. 12. PURPLE PRIMER REQUIRED ON ALL PVC PIPING PER FBC FIFTH EDITION (2014) 605.21. 13. GAS PIPING SHALL COMPLY WITH FLORIDA BUILDING CODE FUEL GAS. (SEPARATE PLANS AND PERMIT REQUIRED) 14. SWIMMING POOL/SPA WATER HEATERS SHALL BEAR THE LABEL OF A RECOGNIZED TESTING AGENCY. 15. PROVIDE BACK FLOW PREVENTOR ON WATER SUPPLY. POOL SYSTEM FLOW RATE: 150 GPM (MAXIMUM FLOW FROM PUMP CURVE) REC./ THERAPY PUMP = 2.7 HP JANDY E-PUMP JEP2.0 VARIABLE SPEED - LOW SPEED = 36 GPM MAX. HIGH SPEED = 150 GPM @ 40 TDH 3" SUCTION PIPE @ 150 GPM = 6.63 FT./SEC. (8 FT./SEC. MAX. - SUCTION LINES) 2.5" BRANCH PIPE @ 75 GPM = 5.13 FT./SEC. (6 FT./SEC. MAX. - PRESSURE LINES) 3" PRESSURE PIPE @ 150 GPM = 6.63 FT./SEC. (10 FT./SEC. MAX. - PRESSURE LINES) CARTRIDGE FILTER - 28 GPM @ 0.375 GPM/ SQ. FT. = 74 SQ. FT. FILTER A}REA ,a�,. �J pJ� ......... Z: tL b FRB pe t O OD co O L ;U s 4 O r C/7 Crj `.nv' mid •, J, �I ��44 �4 z 1n ►!) N Z a�wo U U DRAWN BY MAP CHECKED BY: i WJC DATE: 4-18-17 SCALE: AS NOTED JOB NUMBER: 17 - 287 SHEET 3 OF 3