Loading...
HomeMy WebLinkAboutRevision 12-27-17UM OFFICE USE ONLY: �/ DATE FILED: 1 2.11- REVISION FEE: l"l5.06 PERMIT# %% //— O O / RECEIPT # i 3;L3q,4 PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION _ 2300 VIRGINIA AVENUE (I a _q \e r- D FORT PIERCE, FL 34982.6662 (772)462-1553 DEC 272V117 APPLICATION FOR BUILDING PERMIT REVISIONS PERMiT. i;.; PROJECT INFORMATION St. Lucie County, FL LOCATION/SITE ADDRESS: DETAILED DESCRIPTION OF PROJECT REVISIONS: POOL CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: C P42.1957/2 Q ST. LUCIE CO CERT. #: BUSINESS NAME: r-AYS774[- Poo/-5 eF lllepI 44 A PE.2 /Nc QUALIFIERS NAME: B/412p-L/ M) L L 5 ADDRESS: Y6F0 i�,, U.S 1 CITY: V G e0 BEA C /f STATE: FL. ZIP: 3 2 9 G 7 PHONE (DAYTIME): - 3067 FAX: OWNER/BUILDER INFORMATION: NAME: L o U s/!Y)/!?�/Z /)%C/ft-✓� ADDRESS: 2.200 5. OC jEl4N 4/4NiF CITY: Fob U4vOc,eDAL,E STATE: F'L ZIP 16 PHONE (DAYTIME: ARCHITECT/ENGINEER INFORMATION: xtS NAME: gIAM�S '90SHDUS': ADDRESS: 15Y0 o9t/ `, opm CITY: PomPWIVO BE%4cy STATE: 220f Z 3 9 PHONE (DAYTIME): 3 FAX: SLCCC.• 9123109 Revised 06/30/17 I I V 1 1 . POOL CONTRACTOR TO VERIFY ALL PROPERTY LINE LOCATIONS AND POOL ELEVATION PRIOR TO CONSTRUCTION. POOL LAYOUT AND DIMENSIONS TO BE VERIFIED W/ OWNER PRIOR TO CONSTRUCTION EX, RESIDENCE POOL PILING PLAN SCALE: 1/4"=1'-0" PLACED ON 15% WARD FROM �POOL SHELL - !ES AS SHOWN EXISTING 48" MIN. HIGH RAIL WITH SELF LATCHING GATE THAT SWINGS OUT AWAY FROM POOL AREA VERIFY EXIST. FENCE IN COMPLIANCE W/ CHILD SAFETY BARRIER REQUIREMENTS PER FBC FIFTH EDITION (2014) 51 T-V PROVIDE TILED EDGE TO PREVEN'l'WATER FLOW (TYP. BOTH SIDES) 25' T-6tt --------------------------------- -- 2.5" SCH 40 I I 8' OVERFLOW AND I t AUTO -FILL R 2 VANISHING EDGE (2) LIGHTS I AQUASTAR 32CDFL-32" CHANNEL DRAIN (316 GPM @3.9 FT/SEC THRU GRATE - SINGLE UNBLOCKABLE COMPLIANT W/ ASME/ANSI A 112.19.8 - 2014 OR EQUAL \ — 6' 10'-10118 (3) INLETS FROM (2) INLETS FROM SUN SHELF STEPS EDGEPUMP REC. PUMP 240 SQ. IN. MIN. \ TOP TREAD 2.5" SC14 40 T-V r LJ" J1. t14 _T— STUB -OUT FOR J POOL CLEANER L' 2" SCH 40 I— - ---------------- CSC—�40--=—=-=� PERIMETER BONDING 2.5" SCH 40 WIRE @ 18"MIN. - 24" MAX. FROM W.L. (SEE DETAIL) NOTE: POOL CONTRACTOR TO VERIFY ALL PROPERTY LINE LOCATIONS AND POOL ELEVATION PRIOR TO CONSTRUCTION. POOL LAYOUT AND DIMENSIONS TO BE VERIFIED W/ OWNER PRIOR TO CONSTRUCTION NOTE: PROVIDE WINDOW AND DOOR ALARMS ON ALL OPENINGS THAT LEAD ONTO POOL AREA PER CODE m 3" SC" 40 5 FLUSH SPA 18" BENCH - 20" BELOW W.L. 18" X 18" CORNER STEP (6) THERAPY.IETS AQUASTAR 32CDFL - 32" CHANNEL DRAIN (316 GPM @ 3.9 FT/SEC THRU GRATE - SINGLE UNBLOCKABLE OR EQUAL (1) SPA LIGHT WATER LEVEL SPILLWAY EX. RESIDENCE POOL LAYOUT & PIPING PLAN SCALE: 1/4"=V-0" POOL EQUIPMENT UNDER DECK POOL/SPA EQUIP. SEE. SITE PLAN REINFORCED OR PRODUCT APPROVED CONCRETE SLAB(S) (FIELD VERIFY SIZE & LOCATION) D r PROPOSED WOI". A>: CORRECTIONS I E 7 f I JSf>£ti70 =THAT Rita' ' So ORPEA ;.7 PUCABL£ CODES, 1's , Gh t i 1. kY { 1 t t"� DEC 2 7 2017 PERnAiT TiNG St. Lucie County, FL DRA,I. Bl MAP DECKED B\1 VV I C iTA"TL: 9-17 DECK - BY OTHERS 20.5' N.A.V.D. #4 DIA. REBAR @ 12" O.C. HORZ. AND 6" O.C. VERT. PILING STEEL TO BE BENT INTO POOL FLOOR AND TIED TO \� TOP MAT OF STEEL 16.0' N.A.V.D. PILING NOTES: -RECESS PILING 3" INTO BOTTOM OF POOL FLOOR (TYP.) Q 1 -PILE REINFORCING (NOT SHOWN) O IS TO BE SPECIFIED BY PILING ENGINEER - PILING STEEL TO BE BENT INTO POOL FLOOR AND TIED TO TOP MAT OF STEEL DECK - BY OTHERS #4 DIA. REBAR @ 12" O.C. HORZ.' AND 6" O.C. VERT. 16.0' N.A.V.D. PILE EXTENSION 81 SEE DETAIL 14" DIA. AUGER CAST PILE (8 REQUIRED) 15 TON DESIGN CAPACITY 30 TON ULTIMATE CAPACITY 611 11 4'-811 11' - I8" STEP BEYOND 6" r - - 18" #4 DIA. REB 12 @ 6" O.C.E. _ TOP AND BOTTO PILE EXTENSION SEE DETAIL 6' 14" DIA. AUGER CAST PILE (8 REQUIRED) 15 TON DESIGN CAPACITY 30 TON ULTIMATE CAPACITY 2' #4 DIA. REBAR 12" O.C. HORZ. AND 6" O.C. VERT. 1' 1 in z 1811 Ts 2" — 1211 . W.L. IN PIT -PUMP OFF 3' W.L. IN PIT -PUMP ON 301, (ESTIMATED MIN. DRAW DOWN - 1 TILE BELOW MIN. DRAW DOWN) N.A.V.D. — APPLY BASECRETE WATER PROOFING ON VANISHING EDGE WALL - PER I MANUFACTURES SPECIFICATIONS EXTEND Y ONTO POOL FLOOR — AND ADJOINING WALLS L_J I I RECESS PILING 3" INTO BOTTOM OF - POOL FLOOR (TYP.) POOL/SPA/ AND VANISHING EDG SCALE: 3/8" = 1'-0" 25' 20' #4 DIA. REBAR 3, @ 6" O.C.E.W. TOP AND BOTTOM MATS POOL SECTION TYPE 'O' POOL SCALE: 3/8" = 1'-0" EXISTING PILE,GRADE BEAM AND WALL (BY OTHERS) SECTION 5' —� 6" 20.5' N.A.V.D. #4 DIA. REBAR @ 12" O.C. HORZ. AND 6" O.C. VERT. RECESS PILING 3" INTO BOTTOM OF POOLFLOOR (TYP.) 8.0' N.A.V.D. 6' J s 211 1p' 1: 81-01► t1 O If 11 MAX. #3 DIA. HOOPS �/ I @ 161, O.C. 1 MIN. 211_ 2" h N DECK — BY OTHERS W C7 A r-+ d W O W �, 18" X 18" SQUARE 1:4 W/ 5000 P.S.I. CONC. (4) #5 DIA. REBAR TIED INTO EXIST. PILING STEEL W/ 36" LAP EXISTING PILING PILE EXTENSION DETAIL 14/1 1/211=11_Ott DECK - BY OTHERS 611 4' SUN SHELF SECTION SCALE: 1/2" - 1'-0" #4 DIA. REBAR @ 6" O.C.E.W. 10.511 gr► #4 DIA. REBAR @ 6" O.C.E.W. TOP AND BOTTOM MAI y M G U � r ' � o L; U �`,yl�secaansltF ,y�., LL YW o :n � m rc W w 74 F F 3 • M 00 h Ci F---i r l M�1 � 3 U E"gw0 a W U U 00 0.r P0 0 w U C G O a A, W W Pa w F a •POO U ail/ V1 v1 G� IM��I d F v� U O O O F O .a E~ W x H y w U 0 I j W ;3 ° C f � v ; N MAP w CHECKEDRY= C7 WJC OF qj DECK- BY OTHERS BULLNOS) BRICK CO) ING� SLOPE DECK a; ( y" PER. FOOT 4" -- �,j r MARCITE i OR EQUAL -�--- �\ 444 REINFORCING STEEL SEE SHEET2 R �.1HUS V._:O EN TN ;IICAL WALL SECTION 18" MIN: 24" MAX. (ENTIRE PERIMETER) W.L. #8 SOLID BARE COPPER BOND WIRE W/ APPR CLAMPS (ONE ON EACH SIDE OF POOL-4TOTAL) 6" THICK CONCRETE SLAB(BY OTHERS) W/ (1) 98 BARE SOLID COPPER WIRE (IN SLAB) BONDED TO POOL STEEL AS SHOWN EOUIPOTENTIAL BONDING DETAIL PER FLORIDA BUILDING CODE ADAPTATION OF N.E.C. 2011 SEC. 680.26 1411 O� �w m � PIPE REDUCED TO 1" n w AND RUN TO DECK 3 / BOX 2" SCH 40 PVC CORD LED LIGHT SLEEVE SP 10-22 WALL FITTING - OR EQUAL INSTALLED INSIDE PIPE LED LIGHT DETAIL 10.-5' 10.5' 10.5' 10.5' POOL/SPA SPECIFICATIONS W ATLR LINE �o VACUUM FITTING W/ SELF -CLOSING SAFETY COVER (HAYWARD MODEL #400 OR EQUAL) VACUUM LINE DETAIL (WHEN APPLICABLE) 1)" 19„ 1)" STEP SECTION SIZE: 16'4" X 25' DEPTH: Y-0" TO 4'-11" VOLUME: 12,257 GALLONS ELEVATION DET.ONSITE TURN OVER RATE: 5.67 HR. n 36 GPM MAX. - LOW SPEED (TURN OVER RATE: 1.54 HR. * 132 GPM - HIGH SPEED) DESIGN FLOW RATE = 12,257 GAL./6 HRS./60 MIN. = 34 G.P.M. TILE: STANDARD THERAPY JETS: (6) IN SPA POOL FINISH: MARCITE OR EQUAL PIPING: SCH. 40 INLETS POOL (3 REC.)(2 EDGE) SPA (THRU JETS) DECK: PAVERS ELECTRIC: BY OTHERS POOL LIGHT: (2) LED SPA: LED LADDER: NO HANDRAIL: NO EDGE PUMP: .75 HP JANDY FLO PRO FHPM REC. PUMP: 2.7 HP JANDY E-PUMP JEP 2.0 A.P.S.P. PUMP CERT.: CURVE A - 34 GPM n 1725 RPM FILTER: JANDY CS206 CARTRIDGE - 200 SQ. FT. FILTER AREA HEATER: JANDY 400,000 BTU GAS HEATER VACUUM LINE: YES POOL AREA: 365 S.F. PERIMETER 82 L.F. SPA AREA: 35 S.F. PERIMETER 24 L.F. PIT AREA: 50 S.F. PERIMETER 54 L.P. AUTO -FILL: YES OVERFLOW: YES- JANDY AQUALINK W/ SPA SIDE REMOTE n 3/4 HP JANDY FLRO PRO PUMP MOTOR HEATER (GAS) - IGNAITION SWITCH w/ BUILT-IN OVERLOAD SWITCH W/ 3 - 3 - #12 THHN CU WITHIN 1/2" CONDUIT #12 TWIN CU WITHIN 1/2" MIN. CONDUIT (GFCI PROTECTED) POOL PANEL W/ 80 AMP BRKR & MANUAL MOTOR STARTER SWITCH (2) - 94 & (2) 410 CND 2.7 HP JANDY E-PUMP MOTOR w/ BUILT-IN THHN CU IN OVERLOAD SWITCH W/ 3 - #10 THHN CU 1 1/4" RPVC CONDUIT WITHIN %" MIN. CONDUIT (GFCI PROTECTED) 1ME CLOCK S.P.S.T. TOGGLE W. P. DISCONNECT SWITCH (2) POOL LIGHTS 12 VOLT TRANSFORMER ( GFI NOT REQUIRED) JUNCTION BOX (1) SPA LIGHT (GFI NOT REQUIRED) 1. ALL ELECTRICAL TO COMPLY WITH 2O11 NATIONAL ELECTRIC CODE. ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION. 2. 3412 THHN CU WITHIN 1/2" MIN. CONDUIT FOR POOL LIGHT(S). 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC. w/#8 SOLID, BARE COPPER. 4. PROVIDE W.P.G.F.I. OUTLET 10' MIN. - 20' MAX. FROM WATER'S EDGE. 5. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(B). ELECTRICAL DIAGRAM N.T.S. AQUASTAR 32CDFL - 32" CHANNEL DRAIN (316 GPM @ 3.9 FT/SEC THRU GRATE - SINGLE UNBLOCKABLE OR EQUAL _ 3114" FINISH PLASTER --._ 3 3/32" HYDROSTATIC RELIEF VALVE PORT OR CAP OFF hT911101 MAIN DRAIN SUCTION LINE HYDROSTATIC RELIEF VALVE & TIED TOGETHER AS SHOWN PERFORATED PVC COLLECTION ABOVE - PIPE SIZE PER TUBE, WHERE REQUIRED PLAN MIN. Y2 YARD GRAVEL SUMP NOTE: 25.9 SQUARE INCH OPEN AREA, WRAPPED W/ DRAIN FEILD 316 GPM = 3.9 FEET PER SECOND CLOTH (RECOMMENDED) Channel Main Drain Detail EQUIPMENT LAYOUT SCALE: N.T.S. SCALE: 3/8" = V-0" PUMP FRAME OR FILTER TANK MOUNT OR HEATER /ANCHOR POOL PUMP AND /FILTER PER MFGR'S. N.O.A. 4" THICK REINFORCED CONCRETE SLAB MIN. E.G. ".rnnn F FILTER POOL PUMP, FILTER v AND HEATER ANCHOR POINTS MAY VARY POOL EQUIPMENT ANCHORING DETAIL SEE MFGR. SPECIFICATIONS FOR ADDITIONAL ANCHORING INFORMATION- EQUIPMENT SHAPES MAY VARY LEGEND 1. 2" RETURN TO POOL 2. 2.5" PIT MAIN DRAIN LINE 3.3" SPA MAIN DRAIN LINE 4. 2" VACUUM LINE 5. 3" POOL MAIN DRAIN LINE 6. 2" SKIMMER LINE 7. 3" POOL RETURN LINE 8. 3" RETURN TO SPA JETS A. 3/4 HP JANDY FLO PRO PUMP EDGE PUMP W/ APPR HAIR & LINT STRAINER B. 2.7 HP JANDY E-PUMP JET 2.0 REC. PUMP W/ APPR HAIR & LINT STRAINER C. CARTRIDGE FILTER W/ PRESSURE GAUGE AND AIR RELIEF VALVE D. 1.5" TO WASTE OR DISCHARGE TO GROUND E. JANDY 400,000 BTU GAS HEATER W/ INTERNAL BY-PASS F. VALVES (TYPICAL) GENERAL NOTES: 1. ALL LIGHTS, LADDERS, HANDRAILS, REINFORCING STEEL SHALL BE GROUNDED PER CODE, 2. POOL TO BE CONSTRUCTED OF CONCRETE/GUNITE WITH A MINIMUM COMPRESSIVE STRENGTH OF 4000 P.S.I. AT 28 DAYS. 3. ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OF NEW BILLET STEEL, CONFORMING TO ASTM A-615, GRADE 60, STEEL SHALL BE BENT, LAPPED AND PLACED IN ACCORDANCE WITH ACI STANDARDS. 4. GRATE IN MAIN DRAIN SHALL HAVE A FREE AREA OF 4 TIMES THE AREA OF THE SUCTION LINE. 5. STEPS TO HAVE A 10" MINIMUM TREAD AND A 12" MAXIMUM RISER. 6. POOL TO BE FENCED PER LOCAL CODES. 7. GATES TO BE SELF -LATCHING, SELF -CLOSING AND LOCKABLE. 8. DESIGN, CONSTRUCTION AND WORKMANSHIP SHALL BE IN CONFORMITY WITH THE REQUIREMENTS OF ANSI/ NSPI 3; ANSI/ NSPI 4; ANSI/ NSPI 5; ANSI/ NSPI 6; AND ANSI/APSP 7 2006 AND ANSI/APSP.ICC-15 2011. 9. SPAS AND HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH A COVER DESIGNED TO MINIMIZE HEAT LOSS. EXCEPTIONS: OUTDOOR POOLS DERIVING OVER 70 PERCENT OF THE ENERGY FOR HEATING FROM NON-DEPLETABLE ON -SITE RECOVERED SOURCES COMPUTED OVER AN OPERATING SEASON ARE EXEMPT FROM THIS REQUIREMENT. 10. ALL FEATURES OF THE POOL/SPA SHALL BE INSTALLED IN COMPLIANCE WITH THE FBC FIFTH EDITION (2014)-RESIDENTIAL, SECTION R4101-PRIVATE SWIMMING POOL AND LOCAL AMENDMENTS, IF ANY. 11. RESIDENTIAL SWIMMING POOL BARRIER SHALL COMPLY WITH FBC FIFTH EDITION (2014) - RESIDENTIAL CHAPTER 45 - PRIVATE SWIMMING POOL. 12. POOL CONTRACTOR/OWNER BUILDERS TO VERIFY ALL POOL DIMENSIONS, POOL LOCATION AND SETBACKS PRIOR TO CONSTRUCTION. (CONTACT ENGINEER IF ANY DISCREPANCIES OCCUR) 13. POOL PLANS ARE DESIGNED TO MEET THE FBC FIFTH EDITION (2014) - RESIDENTIAL - PRIVATE SWIMMING POOLS. 14. ENTRAPMENT PROTECTION FOR SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ANSI/APSP 7-2006 AND FBC FIFTH EDITION (2014) - RESIDENTIAL CHAPTER 45, PLUMBING NOTES: L ALL PIPING, EQUIPMENT AND MATERIALS USED IN THE PLUMBING SYSTEM OF SWIMMING POOLS THAT ARE BUILT IN PLACE SHALL CONFORM TO THE FBC FIFTH EDITION (2014), PLUMBING, CHAPTER 45 - PRIVATE SWIMMING POOLS.POOL PIPING SHALL BE DESIGNED SO THE WATER VELOCITY WILL NOT EXCEED 6 FT/SEC ON BRANCH SUCTION LINES, 8 FT/SEC. ON SUCTION LINES AND 10 FT/SEC. PRESSURE LINES. 2. VALVES SHALL BE MADE OF MATERIALS THAT ARE APPROVED IN THE FLORIDA BUILDING CODE, PLUMBING. VALVES LOCATED UNDER CONCRETE SLABS SHALL BE SET IN A PIT HAVING AT LEAST A DIMENSION OF FIVE DIAMETERS WITH A MINIMUM OF AT LEAST 10 INCHES AND FITTED WITH A SUITABLE COVER ALL VALVES SHALL BE LOCATED WHERE THEY WILL BE READILY ACCESSIBLE FOR MAINTENANCE AND REMOVAL. 3. WHERE CHECK VALVES ARE INSTALLED, THEY SHALL BE OF THE SWING OR VERTICAL CHECK PATTERN. 4. ALL HEATERS SHALL BE EQUIPPED WITH AN APPROVED PERMANENT BY-PASS OR ANTI -SIPHON DEVICE INSTALLED TO PROVIDE A POSITIVE MEANS OF RETAINING WATER IN THE HEATER WHEN THE PUMP IS NOT IN OPERATION. 5. ALL POOL PIPING SHALL BE 1.5" SCH. 40 PVC EXCEPT AS SHOWN AND SHALL BEAR THE H.S.P. SEAL, OF APPROVAL, 6. THIS POOL/SPA IS DESIGNED TO WITHSTAND HYDROSTATIC UPLIFT FORCES WHEN EMPTY, FOR WATER TABLE UP TO Y-0" BELOW POOL/SPA DECK ELEVATION. HOWEVER, DUE TO SEASONAL VARIATIONS IN THE WATER TABLE ELEVATIONS, ALL POOL/SPA SHALL BE FITTED WITH A HYDROSTATIC RELIEF VALVE. 7. WATER SUPPLY AND DISPOSAL SHALL BE ARRANGED SO THERE IS NO CROSS SUCTION WITH A DOMESTIC WATER SUPPLY OF WATER DISPOSAL. 8. UNLESS AN APPROVED TYPE OF FILLING SYSTEM IS INSTALLED, ANY WATER SUPPLY WHICH IN THE JUDGEMENT OF THE ADMINISTRATIVE AUTHORITY MAY BE USED TO FILL THE POOL IF EQUIPPED WITH BACKFLOW PROTECTION. NO OVER -THE -RIM FILL SPOUT WILL BE ACCEPTED UNLESS LOCATED UNDER A DIVING BOARD, OR PROPERLY GUARDED. 9. ALL POOL/SPA PIPING SHALL BE INSPECTED AND APPROVED BEFORE COVERING OR CONCEALING. IT SHALL BE TESTED AND PROVED TIGHT TO THE SATISFACTION OF THE ADMINISTRATIVE AUTHORITY, UNDER A STATIC WATER TEST OR AIR PRESSURE TEST OF NOT LESS THAN 35 PSI FOR 15 MINUTES. 10. JOINTS AND CONNECTIONS SHALL BE MADE AS REQUIRED BY THE FLORIDA BUILDING CODE, PLUMBING. 11. ALL WATER HEATING EQUIPMENT SHALL BE INSTALLED WITH FLANGES OR UNION CONNECTION ADJACENT TO THE HEATER. 12. PURPLE PRIMER REQUIRED ON ALL PVC PIPING PER FBC FIFTH EDITION (2014) 605.21. 13. GAS PIPING SHALL COMPLY WITH FLORIDA BUILDING CODE FUEL GAS. (SEPARATE PLANS AND PERMIT REQUIRED) 14. SWIMMING POOL/SPA WATER HEATERS SHALL BEAR THE LABEL OF A RECOGNIZED TESTING AGENCY, 15. PROVIDE BACK FLOW PREVENTOR ON WATER SUPPLY. POOL SYSTEM FLOW RATE: 150 GPM (MAXIMUM FLOW FROM PUMP CURVE) REC./ THERAPY PUMP = 2.7 HP JANDY E-PUMP JEP2.0 VARIABLE SPEED - LOW SPEED = 36 GPM MAX. HIGH SPEED =150 GPM @ 40 TDH 3" SUCTION PIPE @ 150 GPM = 6.63 FT./SEC. (8 FT./SEC. MAX. - SUCTION LINES) 2.5" BRANCH PIPE @ 75 GPM = 5.13 FT./SEC. (6 FT./SEC. MAX. - PRESSURE LINES) 3" PRESSURE PIPE @ 150 GPM = 6.63 FT./SEC. (10 FT./SEC. MAX. - PRESSURE LINES) CARTRIDGE FILTER = 28 GPM @ 0.375 GPM/ SQ. FT. = 74 SQ. FT. FILTER AREA EDGE PUMP = 3/4 HP JANDY FLO PRO FHPM DUAL SPEED - LOW SPEED = 36 GPM MAX. HIGH SPEED = 80 GPM @ 15 TDH 2.5" SUCTION PIPE @ 80 GPM = 5.47 FT./SEC. (8 FT./SEC. MAX. - SUCTION LINES) 2" PRESSURE PIPE @ 80 GPM = 7.80 FT./SEC. (10 FT./SEC. MAX,. - PRESSURE LINES) aI G z u tom. it fr z u Li a6liAY 39Blgf , �� � cr t cz rf)� in K L fj) �Q,{ G o8 a s .... ,`® O%%% E-� F w a M 0 F i kn i'C h�O1l1 vi �' V �aclg0 x In O z 1 tea+ � ca CJ O z G W U 0 O ,C. W w 19. F� A z 0 1 0ROO DRAWN BY; MAP CHECKED UN: r W'JC. 7 DATE: 3 4-18-17