HomeMy WebLinkAboutRevisionOFFICE USE ONLY:
DATE FILED:
REVISION FEE:
LOCATION/SITE
ADDRESS:
Aquavista Lot 7 - 4446 N. Hwy At A
aka Queens Inland Preserve - Lot 7
PERMIT # 1901-0544
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982.5652
(772) 462-1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
REVISED FLOOD VENT LOCATIONS & CALCULATIONS
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CGC 1527445
BUSINESS NAME: Artar Construction LLC
QUALIFIERS NAME: Armando Reyes Toledo
ADDRESS: 13360 SW 40th Street
CITY: Miami STATE: FL
PHONE (DAYTIME): (786) 344-3855
OWNER/BUILDER INFORMATION:
NAME: Venetian Administration LLC
ADDRESS: 7400 W Flagler Street
CITY: Miami
PHONE (DAYTIME:
STATE: FL
ARCMTECT/ENGINEER INFORMATION:
NAME; Knight McGuire & Associates
ADDRESS: 2345 14th Avenue - Suite #3
CITY: Vero Beach
PHONE (DAYTIME): (772) 569-5505
SLCCC: 9123109
Revised 06130/17
STATE: FL
ST. LUCIE CO CERT. #: 31143
FAX:
r li-,N-:
I
ZIP: 33175
ZIP: 33144
ZIP: 32960
r41a1 -
FLOOD VENT CALCULATION
8"x16" ENGINEERED FLOOD VENTS THAT
PROVIDE 250 SF OF FLOOD COVERAGE
GARAGE 1470 SF/250 = 5.9 = 6 VENTS
6 VENTS PROVIDED
LOBBY/STORAGE AREAS 1250 SF/250 = 5.0 = 5 VENTS
2 VENTS PROVIDED + 4 PASS THRU
BELOW POOL DECK AREA 770 SF/250 = 3.1 = 4 VENTS
(+4 VENT FOR LOBBY/STORAGE PASS THRU = 8 VENTS)
8 VENTS PROVIDED
THE DESIGN OF THE FLOOD VENT OPENINGS WILL
E PROVIDE FOR EQUALIZATION OF HYDROSTATIC FLOOD
FORCES ON EXTERIOR WALLS BY ALLOWING FOR THE
In
q AUTOMATIC ENTRY AND EXIT OF FLOODWATERS AS
SPECIFIED IN SECTION 2.7.2.2 OF ASCE 24. PER FBC
R322.2.2 FOOT NOTE 2.1
N
N THE BOTTOM OF EACH OPENING SHALL BE NOT MORE
THAN 1 FOOT ABOVE THE HIGHER OF THE FINAL INTERIOR
o FLOOR AND THE FINISHED EXTERIOR GRADE IMMEDIATELY
BELOW THE OPENING.
FLOOD VENT x2
(under window)
PASS -THROUGH VENTSIL_'
° SCANNED
BY
tp��i` ST LUCIE COUNTY
®N 7 SDK PL. eg. No.41060
DESIGNfBY�
DRAWN BY'<" P FLOOD VENT PLACEMENT
•SCALE'=�,a�-�`�+ Calculations
'DATE- :g = v g : b6-072022 =_, _
AcquaVista LOT 7
GROUND LEVEL
71 1
FLOOD VENT x4
PASS THROUGH
(2x2 stacked)
FLOOD VENT x2
(under window)
THE DRAWINGS ARE THE PROPERTY OF THE
ENGINEER. WHETHER THE PROJECT FOR WHICH
THEY ARE MADE IS EXECUTED OR NOT. COPY OR
USE FOR OTHER PROJECTS IS PERMITTED ONLY
BY WRITTEN CONTRACT WITH THE ENGINEER.
UNAUTHORIZED USE WILL BE PROSECUTED
PURSUANT TO THE COPYRIGHT LAWS.
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
SOCC
FLOOD VENT x3
at n
In
`?
FLOOD VENT x1 L" C "��;
I F_ —
III
II
II
I
I
II
II
II
I�
II
II
I
J r
TOTAL OF EIGHT (8) VENTS
REQUIRED.
VENTS MAY BE POSITIONED
IN ANY OF THE FRANGIBLE
WALLS UNDER THE POOL
DECK AREA ADJACENT TO
THE EXTERIOR, INCLUDING
FRANGIBLE WALLS
CONTINGENT WITH THE
POOL SHELL.
VENTS MAY BE POSITIONED
SEPARATE OR TOGETHER
(MINIMUM TWO LOCATIONS).
FLOOD VENT x8
KMA Engineering & Surveying, LLC
Consulting Engineers & Surveyors
234514th Avenue Suite #3 Vero Beach FI.32960
Phone: (772) 569-9505 E-Mail: civil@�m�R.com
Certificate of Authorization Number: 33705
KMA