HomeMy WebLinkAboutRevision 6-16-22OFFICE USE ONLY: '
DATE FILED: PERMIT # a;�a
REVISION FEE: RECEIPT #
PLANNING & DEVELOPMENT SERVICES
RECEIVED BUILDING& CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
J U N 1 6. 2022 FORT -PIERCE, FL 34982-5652
(772) 462-1553 .
St. Lucie County
Permitting APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION F I L 4CO O PY
LOCATION/SITE
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #:
BUSINESS NAME: PL n_
QUALIFIERS NAME: L
ADDRESS: S`�-f a YI.W W)-eroln�'
CITY: p S L- STATE: A
PHONE (DAYTIME): S-(a q - -r J-%
OWNER/BUILDER INFORMATION:
C -I- 14c 1A,A�-� -pm/,-
ST. LUCIE CO CERT.
LLC
.-ter
(� ZIP:
FAX:
NAME:
ADDRESS:
CITY: STATE:
PHONE (DAYTIME: FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME•
ZIP:
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAYTIME): FAX:
y 4!
o
SLCCC • 9123109,
Revised 06130/17 e.
RECEIVED
FORM R405-2017 J U N 16 2022
FLORIDA ENER07m f FICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MONTANA RESIDENCE
Street: TRANQUILITY BASE LANE
Builder Name: PLM CONSTRUCT
Permit Office: ST LUCIE COUNT I L E COPY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner. THOMAS AND ELIZABETH MONTANA
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing N om ) ,
s 8 . (.)
Insulation Area
2. Single family or multiple family D
n to - ock t I, xtedor
Sc
R=4.1 2568.80 ftz
/
a- ' ood, j e
R=11.0 240.00 ftz
3. Number of units, if multiple family 1
R= ftz
4. Number of Bedrooms 3
d• N/A
R= ftz
10. Ceiling Types (2733.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 2733.00 ftz
6. Conditioned floor area above grade (ftz) 2733
b. N/A
R= ftz
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftZ
11. Ducts
R ft2
7. Windows(414.8 sqft.) Description Area
Sup: Attic, Ret: Attic, AH: Attic
6 130
a. U-Factor: Sgl, U=0.65 192.00 ftZ
b. Sup: Attic, Ret: Attic, AH: Attic
6 130
SHGC: SHGC=0.21
b. U-Factor: Sgl, U=0.58 174.33 ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.24
a. Central Unit
24.0 SEER:16.00
b. Central Unit
24.0 SEER:16.00
c. U-Factor: Sgl, U=0.69 40.00 ftz
SHGC: SHGC=0.22
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 8.50 ftz
a. Electric Strip Heat
17.0 COP:1.00
SHGC: other (see details)
b. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average Overhang Depth: 8.172 ft.
Area Weighted Average SHGC: 0.225
14. Hot water systems
a. Electric Tankless
Cap: 1 gallons
8. Floor Types (2733.0 sqft.) Insulation Area
EF:0.990
a. Slab -On -Grade Edge Insulation R=0.0 2733.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits
None
Glass/Floor Area: 0.152 Total Proposed Modified Loads: 90.42
PASS
Total Baseline Loads: 91.55
1 hereby certify that the plans and specifications covered by
Review of the plans and
01TKE ST9?�
this calculation are in compliance with the Florida Energy
specifications covered by this
.y , __ Off,
Code.
calculation indicates compliance
with the Florida Energy Code.
ti �m�,'�-: `:€i••;;��„ O
PREPARED BY:
DATE: 6-15-20221
Before construction is completed
this building will be inspected for
compliance with Section 553.908
a
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Ene y Co e.
COD't��
OWNER/ACr4VNT.
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
6/15/2022 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
MONTANA RESIDENCE
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2733
Lot #
Owner Name:
THOMAS AND ELIZABETH
M
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
PLM CONSTRUCTION
Rotate Angle:
0
Street:
TRANQUILITY BASE L
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Detached
FL,
New/Ewsting:
New (From Plans)
Comment:
CLIMATE
v
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
AH U 1
1492
15190
2
AHU 2
1241
13609
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
MASTER BEDROO
315
3465 No
0
1
1
Yes
Yes
Yes
2
M TOILET
30
300 No
0
1
Yes
Yes
Yes
3
M BATH
246
2460 No
0
1
Yes
Yes
Yes
4
M HALL
40
400 No
0
1
No
Yes
Yes
5
M WIC
168
1680 No
0
1
Yes
Yes
Yes
6
FOYER
90
1080 No
0
1
Yes
Yes
Yes
7
LAUNDRY RM
130
1300 No
0
1
Yes
Yes
Yes
8
GREAT RM
352
4224 No
0
1
Yes
Yes
Yes
9
PANTRY
30
300 No
0
1
No
Yes
Yes
10
KITCHEN/NOOK
452
4520 Yes
0
1
Yes
Yes
Yes
11
ENTRY WAY
78
780 No
0
1
No
Yes
Yes
12
BEDROOM 2
169
1690 No
0
1
1
Yes
Yes
Yes
13
WIC
15
150 No
0
1
No
Yes
Yes
14
BATH 2
50
500 No
0
1
Yes
Yes
Yes
15
BEDROOM 3
169
1690 No
0
1
1
Yes
Yes
Yes
16
CLST 3
18
180 No
0
1
Yes
Yes
Yes
17
BATH 3
54
540 No
0
1
Yes
Yes
Yes
18
THEATER
270
2970 No
0
1
Yes
Yes
Yes
19
HALL
57
570 No
0
1
Yes
Yes
Yes
6/15/2022 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
MASTER BEDRO
45 ft
0
315 ft2
----
1
0
0
2SIab-On-Grade Edge Insulation
M TOILET
5 ft
0
30 ft2
----
1
0
0
3 Slab -On -Grade Edge Insulation
M BATH
14 ft
0
246 ft2
----
1
0
0
4 Slab -On -Grade Edge Insulation
M HALL
1 ft
0
40 ft2
----
1
0
0
5 Slab -On -Grade Edge Insulation
M W IC
34 ft
0
168 ft2
----
1
0
0
6 Slab -On -Grade Edge Insulation
FOYER
9 ft
0
90 ft2
----
1
0
0
7 Slab -On -Grade Edge Insulation
LAUNDRY RM
8 ft
0
130 ft2
----
1
0
0
8 Slab -On -Grade Edge Insulation
GREAT RM
16 ft
0
352 ft2
----
1
0
0
9 Slab -On -Grade Edge Insulation
PANTRY
1 ft
0
30 ft2
----
1
0
0
10SIab-On-Grade Edge Insulation
KITCHEN/NOOK
21 ft
0
452 ft2
----
1
0
0
11SIab-On-Grade Edge Insulation
ENTRY WAY
1 ft
0
78 ft2
----
1
0
0
12SIab-On-Grade Edge Insulation
BEDROOM 2
13 ft
0
169 ft2
----
1
0
0
13SIab-On-Grade Edge Insulation
WIC 2
1 ft
0
15 ft2
____
1
0
0
14SIab-On-Grade Edge Insulation
BATH 2
5 ft
0
50 ft2
----
1
0
0
15SIab-On-Grade Edge Insulation
BEDROOM 3
13 ft
0
169 ft2
----
1
0
0
16SIab-On-Grade Edge Insulation
CLST 3
2 ft
0
18 ft2
----
1
0
0
17SIab-On-Grade Edge Insulation
BATH 3
6 ft
0
54 ft2
----
1
0
0
18SIab-On-Grade Edge Insulation
THEATER
48 ft
0
270 ft2
----
1
0
0
19SIab-On-Grade Edge Insulation
HALL
3.6 ft
0
57 ft2
____
1
0
0
ROOF
v
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck Pitch
# Type Materials Area
Area Color
Barr
Absor. Tested
Tested
Insul. (deg)
1 Hip Composition shingles 3057 ft2
0 ft2 Medium
N
0.4 No 0.9
No
20
26.6
ATTIC
/
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented
0 2733 ft2
N N
6/15/2022 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Flat ceiling under attic (Unvented) MASTER BEDRO
0
Blown
315 ft2
0.1
Wood
2
Flat ceiling under attic (Unvented) M TOILET
0
Blown
30 ft2
0.1
Wood
3
Flat ceiling under attic (Unvented) M BATH
0
Blown
246 ft2
0.1
Wood
4
Flat ceiling under attic (Unvented) M HALL
0
Blown
40 ft2
0.1
Wood
5
Flat ceiling under attic (Unvented) M WIC
0
Blown
168 ft2
0.1
Wood
6
Flat ceiling under attic (Unvented) FOYER
0
Blown
90 ft2
0.1
Wood
7
Flat ceiling under attic (Unvented) LAUNDRY RM
0
Blown
130 ft2
0.1
Wood
8
Flat ceiling under attic (Unvented) GREAT RM
0
Blown
352 ft2
0.1
Wood
9
Flat ceiling under attic (Unvented) PANTRY
0
Blown
30 ft2
0.1
Wood
10
Flat ceiling under attic (Unvented) KITCHEN/NOOK
0
Blown
452 ft2
0.1
Wood
11
Flat ceiling under attic (Unvented) ENTRY WAY
0
Blown
78 ft2
0.1
Wood
12
Flat ceiling under attic (Unvented) BEDROOM 2
0
Blown
169 ft2
0.1
Wood
13
Flat ceiling under attic (Unvented) WIC 2
0
Blown
15 ft2
0.1
Wood
14
Flat ceiling under attic (Unvented) BATH 2
0
Blown
50 ft2
0.1
Wood
15
Flat ceiling under attic (Unvented) BEDROOM 3
0
Blown
169 ft2
0.1
Wood
16
Flat ceiling under attic (Unvented) CLST 3
0
Blown
18 ft2
0.1
Wood
17
Flat ceiling under attic (Unvented) BATH 3
0
Blown
54 ft2
0.1
Wood
18
Flat ceiling under attic (Unvented) THEATER
0
Blown
270 ft2
0.1
Wood
19
Flat ceiling under attic (Unvented) HALL
0
Blown
57 ft2
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
1
N
Exterior Concrete Block - Int InsuMASTER BE
4.1
16
0 11
0
176.0 ft2
0
0
0.4
0
2
E
Exterior Concrete Block - Int InsuMASTER BE
4.1
19
0 11
0
209.0 ft2
0
0
0.4
0
3
W
Exterior Concrete Block - Int InsuMASTER BE
4.1
10
0 11
0
110.0 ft2
0
0
0.4
0
4
E
Exterior Concrete Block - Int Insul M TOILET
4.1
5
0 10
0
50.0 ft2
0
0
0.4
0
5
E
Exterior Concrete Block - Int Insul M BATH
4.1
14
0 10
0
140.0 ft2
0
0
0.4
0
6
E
Exterior Concrete Block - Int Insul M W IC
4.1
9
0 10
0
90.0 ft2
0
0
0.4
0
7
S
Exterior Concrete Block- Int Insul M W IC
4.1
20
0 10
0
200.0 ft2
0
0
0.4
0
8
W
Exterior Concrete Block- Int Insul M W IC
4.1
5
0 10
0
50.0 ft2
0
0
0.4
0
9
S
Exterior Concrete Block - Int Insul FOYER
4.1
9
0 12
0
108.0 ft2
0
0
0.4
0
10
S
Exterior Concrete Block - Int InsuLAUNDRY R
4.1
8
0 10
0
80.0 ft2
0
0
0.4
0
_ 11
S
Garage Frame - Wood LAUNDRY R
11
5
0 10
0
50.0 ft2
0
0.1
0.4
0
12
N
Exterior Concrete Block - Int InsulGREAT RM
4.1
16
0 12
0
192.0 ft2
0
0
0.4
0
_ 13
N
Exterior Concrete Block - Int InsdKITCHEN/NO
4.1
11
0 10
0
110.0 ft2
0
0
0.4
0
_ 14
E
Exterior Concrete Block - Int InsLIKITCHEN/NO
4.1
10
0 10
0
100.0 ft2
0
0
0.4
0
15
S
Garage Frame- Wood ENTRY WAY
11
6
0 10
0
60.0 ft2
0
0.1
0.4
0
16
W
Exterior Concrete Block - Int InsuBEDROOM 2
4.1
13
0 10
0
130.0 ft2
0
0
0.4
0
17
S
Garage Frame- Wood BEDROOM 2
11
13
0 10
0
130.0 ft2
0
0.1
0.4
0
18
W
Exterior Concrete Block - Int Insul BATH 2
4.1
5
0 10
0
50.0 ft2
0
0
0.4
0
19
W
Exterior Concrete Block - Int InsuBEDROOM 3
4.1
13
0 10
0
130.0 ft2
0
0
0.4
0
20
W
Exterior Concrete Block - Int Insul CLST 3
4.1
2
0 10
0
20.0 ft2
0
0
0.4
0
21
W
Exterior Concrete Block - Int Insul BATH 3
4.1
6
0 10
0
60.0 ft2
0
0
0.4
0
6/15/2022 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
r
t-UKM K4U5-1U1 /
INNU I
,UMMAKY UNIZUKLI, I KtVUK
WALLS
Adjacent
Space
Cavity Width
R-I/:;]-,e Et In
Height
Et in
Area
Sheathing Framing
R-Vah le Erection
Solar Below
AhSor r�rarfe%
22 N
Exterior
Concrete Block - Int
Insul THEATER
4.1 15
0
11 0
165.0 ftz
0
0
0.4
0
_ 23 E
Exterior
Concrete Block - Int
Insul THEATER
4.1 14
0
11 0
154.0 ftz
0
0
0.4
0
24 W
Exterior
Concrete Block - Int
Insul THEATER
4.1 19
0
11 0
209.0 ftz
0
0
0.4
0
25 NE
Exterior
Concrete Block - Int Insul HALL
4.1 3
7
10 0
35.8 ftz
0
0
0.4
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated
ENTRY WAY
None
.23
2
8
8
21.3 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Omt ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N
1
Metal
Low-E Single
Yes
0.69 0.22
Y
40.0 ftz
1 ft 6 in
1 ft 4 in
None
None
2
E
2
Metal
Low-E Single
Yes
0.58 0.24
Y
20.0 ftz
1 ft 6 in
1 ft 4 in
None
None
3
E
4
Metal
Low-E Single
Yes
0.58 0.24
Y
6.0 ftz
1 ft 6 in
1 ft 4 in
None
None
4
E
5
Metal
Low-E Single
Yes
0.58 0.24
Y
5.0 ftz
1 ft 6 in
1 ft 4 in
None
None
5
E
5
Metal
Low-E Single
Yes
0.58 0.24
Y
6.0 ftz
1 ft 6 in
1 ft 4 in
None
None
6
S
7
Metal
Low-E Single
Yes
0.58 0.24
Y
10.0 ftz
1 ft 6 in
1 ft 4 in
None
None
7
S
9
Metal
Low-E Single
Yes
0.45 0.26
Y
8.5 ftz
6 ft 6 in
1 ft 4 in
None
None
8
S
9
Metal
Low-E Single
Yes
0.58 0.24
Y
48.0 ftz
6 ft 6 in
1 ft 4 in
None
None
9
S
10
Metal
Low-E Single
Yes
0.58 0.24
Y
10.0 ftz
1 ft 6 in
1 ft 4 in
None
None
10
N
12
Metal
Low-E Single
Yes
0.65 0.21
Y
96.0 ftz
10 ft 6 in
1 ft 4 in
None
None
11
N
13
Metal
Low-E Single
Yes
0.65 0.21
Y
48.0 ftz
10 ft 6 in
1 ft 4 in
None
None
12
E
14
Metal
Low-E Single
Yes
0.65 0.21
Y
48.0 ftz
20 ft 6 in
1 ft 4 in
None
None
13
W
16
Metal
Low-E Single
Yes
0.58 0.24
Y
15.0 ftz
1 ft 6 in
1 ft 4 in
None
None
14
W
18
Metal
Low-E Single
Yes
0.58 0.24
Y
9.0 ftz
1 ft 6 in
1 ft 4 in
None
None
15
W
19
Metal
Low-E Single
Yes
0.58 0.24
Y
15.0 ftz
1 ft 6 in
1 ft 4 in
None
None
16
W
21
Metal
Low-E Single
Yes
0.58 0.24
Y
9.0 ftz
1 ft 6 in
1 ft 4 in
None
None
17
NE
25
Metal
Low-E Single
Yes
0.58 0.24
Y
21.3 ftz
14 ft 6 in
1 ft 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
1008 ftz
1008 ftz
24 ft
loft
11
INFILTRATION
# Scope
Method
SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Whclehouse
Proposed ACH(50) .000335 2399.9 131.67
247.19
.1008
5
6/15/2022 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat!
None
COPA
17 kBtu/hr
1
sys#1
2 Electric Strip Heatt
None
COP:1
17 kBtu/hr
2
sys#2
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR
Block
Ducts
1 Central Unitt
Split
Single SEER: 16
24 kBtu/hr
720 cfm 0.8
1
sys#1
2 Central Unit/
Split
Single SEER: 16
24 kBtu/hr
720 cfm 0.8
2
sys#2
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt Conservation
1 Electric Tankless
Garage
0.99 1 gal 55.1 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
— Supply --
— Return --
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT QN
RLF
Heat Cool
1 Attic 6 130 ft2
Attic
13 ft2 Default Leakage
Attic
(Default) c(Default) c
1 1
2 Attic 6 130 ft2
Attic
13 ft2 Default Leakage
Attic
(Default) c(Default) c
2 2
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan Feb Mar
Heatin HJan HFeb NMar
Apr
A r
Ma Jun Jul
Ma Jun Jul
Au
AugMe
ri
Se Oct
Oct
Nov
Nov
Dec
Dec
Venting Jan Feb Mar
Apr
May Jun Jul
Aug
Sep Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8 9 10
11
12
Cooling (W D) AM 78
78 78
78 78 78
78
78 80 80
80
80
PM 80
80 80
80 78 78
78
78 78 78
78
78
Cooling (WEH) AM 78
78 78
78 78 78
78
78 80 80
80
80
PM 80
80 80
80 78 78
78
78 78 78
78
78
Heating (WD) AM 65
65 65
65 65 65
65
68 68 68
68
68
PM 68
68 68
68 68 68
68
68 68 68
68
68
Heating (WEH) AM 65
65 65
65 65 65
65
68 68 68
68
68
PM 68
68 68
68 68 68
68
68 68 68
68
68
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ftz
ft
0.3
M HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M WIC
6/15/2022 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(B Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GREAT RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN/NOOK
Default(8 Ibs/sq.ft.
ft2
ft
0.3
ENTRY WAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8lbs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
THEATER
Default 8 Ibs/s .ft.
ft2
ft
0.3
HALL
6/15/2022 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: MONTANA RESIDENCE Builder Name: PLM CONSTRUCTION
Street: TRANQUILITY BASE LANE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
U
Owner: THOMAS AND ELIZABETH MONTANA Jurisdiction: ST LUCIE COUNTY
=
Design Location: FL, Fort Pierce
c�
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
6/15/2022 11:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Detached or multiple -family
2. Detached
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
48.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2733
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.620
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.225
14. Heating system: Capacity
34.0
c) Area
7c.
414.8
a) Split system heat -pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.99
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
0.0
b) Cross ventilation
No
b) Single assembly, no airspace
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be eted basr�ed on installed code compliant features.
Builder Signature: Date: (O o 02
Address of New Home: TRANQUILITY BASE LANE City/FL Zip: FORT PIERCE, FL
6/15/2022 11:27:01 AM EnergyGauge® USA 7.0.07 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1