Loading...
HomeMy WebLinkAboutRevision 6-16-22OFFICE USE ONLY: ' DATE FILED: PERMIT # a;�a REVISION FEE: RECEIPT # PLANNING & DEVELOPMENT SERVICES RECEIVED BUILDING& CODE REGULATION DIVISION 2300 VIRGINIA AVENUE J U N 1 6. 2022 FORT -PIERCE, FL 34982-5652 (772) 462-1553 . St. Lucie County Permitting APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION F I L 4CO O PY LOCATION/SITE DETAILED DESCRIPTION OF PROJECT REVISIONS: CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: PL n_ QUALIFIERS NAME: L ADDRESS: S`�-f a YI.W W)-eroln�' CITY: p S L- STATE: A PHONE (DAYTIME): S-(a q - -r J-% OWNER/BUILDER INFORMATION: C -I- 14c 1A,A�-� -pm/,- ST. LUCIE CO CERT. LLC .-ter (� ZIP: FAX: NAME: ADDRESS: CITY: STATE: PHONE (DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME• ZIP: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: y 4! o SLCCC • 9123109, Revised 06130/17 e. RECEIVED FORM R405-2017 J U N 16 2022 FLORIDA ENER07m f FICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MONTANA RESIDENCE Street: TRANQUILITY BASE LANE Builder Name: PLM CONSTRUCT Permit Office: ST LUCIE COUNT I L E COPY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner. THOMAS AND ELIZABETH MONTANA Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing N om ) , s 8 . (.) Insulation Area 2. Single family or multiple family D n to - ock t I, xtedor Sc R=4.1 2568.80 ftz / a- ' ood, j e R=11.0 240.00 ftz 3. Number of units, if multiple family 1 R= ftz 4. Number of Bedrooms 3 d• N/A R= ftz 10. Ceiling Types (2733.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2733.00 ftz 6. Conditioned floor area above grade (ftz) 2733 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftZ 11. Ducts R ft2 7. Windows(414.8 sqft.) Description Area Sup: Attic, Ret: Attic, AH: Attic 6 130 a. U-Factor: Sgl, U=0.65 192.00 ftZ b. Sup: Attic, Ret: Attic, AH: Attic 6 130 SHGC: SHGC=0.21 b. U-Factor: Sgl, U=0.58 174.33 ftz 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.24 a. Central Unit 24.0 SEER:16.00 b. Central Unit 24.0 SEER:16.00 c. U-Factor: Sgl, U=0.69 40.00 ftz SHGC: SHGC=0.22 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 8.50 ftz a. Electric Strip Heat 17.0 COP:1.00 SHGC: other (see details) b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 8.172 ft. Area Weighted Average SHGC: 0.225 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (2733.0 sqft.) Insulation Area EF:0.990 a. Slab -On -Grade Edge Insulation R=0.0 2733.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ftz 15. Credits None Glass/Floor Area: 0.152 Total Proposed Modified Loads: 90.42 PASS Total Baseline Loads: 91.55 1 hereby certify that the plans and specifications covered by Review of the plans and 01TKE ST9?� this calculation are in compliance with the Florida Energy specifications covered by this .y , __ Off, Code. calculation indicates compliance with the Florida Energy Code. ti �m�,'�-: `:€i••;;��„ O PREPARED BY: DATE: 6-15-20221 Before construction is completed this building will be inspected for compliance with Section 553.908 a I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Ene y Co e. COD't�� OWNER/ACr4VNT. BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 6/15/2022 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: MONTANA RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2733 Lot # Owner Name: THOMAS AND ELIZABETH M Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: PLM CONSTRUCTION Rotate Angle: 0 Street: TRANQUILITY BASE L Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Ewsting: New (From Plans) Comment: CLIMATE v Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AH U 1 1492 15190 2 AHU 2 1241 13609 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 315 3465 No 0 1 1 Yes Yes Yes 2 M TOILET 30 300 No 0 1 Yes Yes Yes 3 M BATH 246 2460 No 0 1 Yes Yes Yes 4 M HALL 40 400 No 0 1 No Yes Yes 5 M WIC 168 1680 No 0 1 Yes Yes Yes 6 FOYER 90 1080 No 0 1 Yes Yes Yes 7 LAUNDRY RM 130 1300 No 0 1 Yes Yes Yes 8 GREAT RM 352 4224 No 0 1 Yes Yes Yes 9 PANTRY 30 300 No 0 1 No Yes Yes 10 KITCHEN/NOOK 452 4520 Yes 0 1 Yes Yes Yes 11 ENTRY WAY 78 780 No 0 1 No Yes Yes 12 BEDROOM 2 169 1690 No 0 1 1 Yes Yes Yes 13 WIC 15 150 No 0 1 No Yes Yes 14 BATH 2 50 500 No 0 1 Yes Yes Yes 15 BEDROOM 3 169 1690 No 0 1 1 Yes Yes Yes 16 CLST 3 18 180 No 0 1 Yes Yes Yes 17 BATH 3 54 540 No 0 1 Yes Yes Yes 18 THEATER 270 2970 No 0 1 Yes Yes Yes 19 HALL 57 570 No 0 1 Yes Yes Yes 6/15/2022 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 45 ft 0 315 ft2 ---- 1 0 0 2SIab-On-Grade Edge Insulation M TOILET 5 ft 0 30 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulation M BATH 14 ft 0 246 ft2 ---- 1 0 0 4 Slab -On -Grade Edge Insulation M HALL 1 ft 0 40 ft2 ---- 1 0 0 5 Slab -On -Grade Edge Insulation M W IC 34 ft 0 168 ft2 ---- 1 0 0 6 Slab -On -Grade Edge Insulation FOYER 9 ft 0 90 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulation LAUNDRY RM 8 ft 0 130 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulation GREAT RM 16 ft 0 352 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulation PANTRY 1 ft 0 30 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulation KITCHEN/NOOK 21 ft 0 452 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulation ENTRY WAY 1 ft 0 78 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulation BEDROOM 2 13 ft 0 169 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulation WIC 2 1 ft 0 15 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation BATH 2 5 ft 0 50 ft2 ---- 1 0 0 15SIab-On-Grade Edge Insulation BEDROOM 3 13 ft 0 169 ft2 ---- 1 0 0 16SIab-On-Grade Edge Insulation CLST 3 2 ft 0 18 ft2 ---- 1 0 0 17SIab-On-Grade Edge Insulation BATH 3 6 ft 0 54 ft2 ---- 1 0 0 18SIab-On-Grade Edge Insulation THEATER 48 ft 0 270 ft2 ---- 1 0 0 19SIab-On-Grade Edge Insulation HALL 3.6 ft 0 57 ft2 ____ 1 0 0 ROOF v Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 3057 ft2 0 ft2 Medium N 0.4 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2733 ft2 N N 6/15/2022 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Flat ceiling under attic (Unvented) MASTER BEDRO 0 Blown 315 ft2 0.1 Wood 2 Flat ceiling under attic (Unvented) M TOILET 0 Blown 30 ft2 0.1 Wood 3 Flat ceiling under attic (Unvented) M BATH 0 Blown 246 ft2 0.1 Wood 4 Flat ceiling under attic (Unvented) M HALL 0 Blown 40 ft2 0.1 Wood 5 Flat ceiling under attic (Unvented) M WIC 0 Blown 168 ft2 0.1 Wood 6 Flat ceiling under attic (Unvented) FOYER 0 Blown 90 ft2 0.1 Wood 7 Flat ceiling under attic (Unvented) LAUNDRY RM 0 Blown 130 ft2 0.1 Wood 8 Flat ceiling under attic (Unvented) GREAT RM 0 Blown 352 ft2 0.1 Wood 9 Flat ceiling under attic (Unvented) PANTRY 0 Blown 30 ft2 0.1 Wood 10 Flat ceiling under attic (Unvented) KITCHEN/NOOK 0 Blown 452 ft2 0.1 Wood 11 Flat ceiling under attic (Unvented) ENTRY WAY 0 Blown 78 ft2 0.1 Wood 12 Flat ceiling under attic (Unvented) BEDROOM 2 0 Blown 169 ft2 0.1 Wood 13 Flat ceiling under attic (Unvented) WIC 2 0 Blown 15 ft2 0.1 Wood 14 Flat ceiling under attic (Unvented) BATH 2 0 Blown 50 ft2 0.1 Wood 15 Flat ceiling under attic (Unvented) BEDROOM 3 0 Blown 169 ft2 0.1 Wood 16 Flat ceiling under attic (Unvented) CLST 3 0 Blown 18 ft2 0.1 Wood 17 Flat ceiling under attic (Unvented) BATH 3 0 Blown 54 ft2 0.1 Wood 18 Flat ceiling under attic (Unvented) THEATER 0 Blown 270 ft2 0.1 Wood 19 Flat ceiling under attic (Unvented) HALL 0 Blown 57 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N Exterior Concrete Block - Int InsuMASTER BE 4.1 16 0 11 0 176.0 ft2 0 0 0.4 0 2 E Exterior Concrete Block - Int InsuMASTER BE 4.1 19 0 11 0 209.0 ft2 0 0 0.4 0 3 W Exterior Concrete Block - Int InsuMASTER BE 4.1 10 0 11 0 110.0 ft2 0 0 0.4 0 4 E Exterior Concrete Block - Int Insul M TOILET 4.1 5 0 10 0 50.0 ft2 0 0 0.4 0 5 E Exterior Concrete Block - Int Insul M BATH 4.1 14 0 10 0 140.0 ft2 0 0 0.4 0 6 E Exterior Concrete Block - Int Insul M W IC 4.1 9 0 10 0 90.0 ft2 0 0 0.4 0 7 S Exterior Concrete Block- Int Insul M W IC 4.1 20 0 10 0 200.0 ft2 0 0 0.4 0 8 W Exterior Concrete Block- Int Insul M W IC 4.1 5 0 10 0 50.0 ft2 0 0 0.4 0 9 S Exterior Concrete Block - Int Insul FOYER 4.1 9 0 12 0 108.0 ft2 0 0 0.4 0 10 S Exterior Concrete Block - Int InsuLAUNDRY R 4.1 8 0 10 0 80.0 ft2 0 0 0.4 0 _ 11 S Garage Frame - Wood LAUNDRY R 11 5 0 10 0 50.0 ft2 0 0.1 0.4 0 12 N Exterior Concrete Block - Int InsulGREAT RM 4.1 16 0 12 0 192.0 ft2 0 0 0.4 0 _ 13 N Exterior Concrete Block - Int InsdKITCHEN/NO 4.1 11 0 10 0 110.0 ft2 0 0 0.4 0 _ 14 E Exterior Concrete Block - Int InsLIKITCHEN/NO 4.1 10 0 10 0 100.0 ft2 0 0 0.4 0 15 S Garage Frame- Wood ENTRY WAY 11 6 0 10 0 60.0 ft2 0 0.1 0.4 0 16 W Exterior Concrete Block - Int InsuBEDROOM 2 4.1 13 0 10 0 130.0 ft2 0 0 0.4 0 17 S Garage Frame- Wood BEDROOM 2 11 13 0 10 0 130.0 ft2 0 0.1 0.4 0 18 W Exterior Concrete Block - Int Insul BATH 2 4.1 5 0 10 0 50.0 ft2 0 0 0.4 0 19 W Exterior Concrete Block - Int InsuBEDROOM 3 4.1 13 0 10 0 130.0 ft2 0 0 0.4 0 20 W Exterior Concrete Block - Int Insul CLST 3 4.1 2 0 10 0 20.0 ft2 0 0 0.4 0 21 W Exterior Concrete Block - Int Insul BATH 3 4.1 6 0 10 0 60.0 ft2 0 0 0.4 0 6/15/2022 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 r t-UKM K4U5-1U1 / INNU I ,UMMAKY UNIZUKLI, I KtVUK WALLS Adjacent Space Cavity Width R-I/:;]-,e Et In Height Et in Area Sheathing Framing R-Vah le Erection Solar Below AhSor r�rarfe% 22 N Exterior Concrete Block - Int Insul THEATER 4.1 15 0 11 0 165.0 ftz 0 0 0.4 0 _ 23 E Exterior Concrete Block - Int Insul THEATER 4.1 14 0 11 0 154.0 ftz 0 0 0.4 0 24 W Exterior Concrete Block - Int Insul THEATER 4.1 19 0 11 0 209.0 ftz 0 0 0.4 0 25 NE Exterior Concrete Block - Int Insul HALL 4.1 3 7 10 0 35.8 ftz 0 0 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated ENTRY WAY None .23 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.69 0.22 Y 40.0 ftz 1 ft 6 in 1 ft 4 in None None 2 E 2 Metal Low-E Single Yes 0.58 0.24 Y 20.0 ftz 1 ft 6 in 1 ft 4 in None None 3 E 4 Metal Low-E Single Yes 0.58 0.24 Y 6.0 ftz 1 ft 6 in 1 ft 4 in None None 4 E 5 Metal Low-E Single Yes 0.58 0.24 Y 5.0 ftz 1 ft 6 in 1 ft 4 in None None 5 E 5 Metal Low-E Single Yes 0.58 0.24 Y 6.0 ftz 1 ft 6 in 1 ft 4 in None None 6 S 7 Metal Low-E Single Yes 0.58 0.24 Y 10.0 ftz 1 ft 6 in 1 ft 4 in None None 7 S 9 Metal Low-E Single Yes 0.45 0.26 Y 8.5 ftz 6 ft 6 in 1 ft 4 in None None 8 S 9 Metal Low-E Single Yes 0.58 0.24 Y 48.0 ftz 6 ft 6 in 1 ft 4 in None None 9 S 10 Metal Low-E Single Yes 0.58 0.24 Y 10.0 ftz 1 ft 6 in 1 ft 4 in None None 10 N 12 Metal Low-E Single Yes 0.65 0.21 Y 96.0 ftz 10 ft 6 in 1 ft 4 in None None 11 N 13 Metal Low-E Single Yes 0.65 0.21 Y 48.0 ftz 10 ft 6 in 1 ft 4 in None None 12 E 14 Metal Low-E Single Yes 0.65 0.21 Y 48.0 ftz 20 ft 6 in 1 ft 4 in None None 13 W 16 Metal Low-E Single Yes 0.58 0.24 Y 15.0 ftz 1 ft 6 in 1 ft 4 in None None 14 W 18 Metal Low-E Single Yes 0.58 0.24 Y 9.0 ftz 1 ft 6 in 1 ft 4 in None None 15 W 19 Metal Low-E Single Yes 0.58 0.24 Y 15.0 ftz 1 ft 6 in 1 ft 4 in None None 16 W 21 Metal Low-E Single Yes 0.58 0.24 Y 9.0 ftz 1 ft 6 in 1 ft 4 in None None 17 NE 25 Metal Low-E Single Yes 0.58 0.24 Y 21.3 ftz 14 ft 6 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1008 ftz 1008 ftz 24 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Whclehouse Proposed ACH(50) .000335 2399.9 131.67 247.19 .1008 5 6/15/2022 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat! None COPA 17 kBtu/hr 1 sys#1 2 Electric Strip Heatt None COP:1 17 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitt Split Single SEER: 16 24 kBtu/hr 720 cfm 0.8 1 sys#1 2 Central Unit/ Split Single SEER: 16 24 kBtu/hr 720 cfm 0.8 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Garage 0.99 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply -- — Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 130 ft2 Attic 13 ft2 Default Leakage Attic (Default) c(Default) c 1 1 2 Attic 6 130 ft2 Attic 13 ft2 Default Leakage Attic (Default) c(Default) c 2 2 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb Mar Heatin HJan HFeb NMar Apr A r Ma Jun Jul Ma Jun Jul Au AugMe ri Se Oct Oct Nov Nov Dec Dec Venting Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ftz ft 0.3 M HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC 6/15/2022 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(B Ibs/sq.ft. ft2 ft 0.3 LAUNDRY RM Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT RM Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN/NOOK Default(8 Ibs/sq.ft. ft2 ft 0.3 ENTRY WAY Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8lbs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 THEATER Default 8 Ibs/s .ft. ft2 ft 0.3 HALL 6/15/2022 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: MONTANA RESIDENCE Builder Name: PLM CONSTRUCTION Street: TRANQUILITY BASE LANE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: U Owner: THOMAS AND ELIZABETH MONTANA Jurisdiction: ST LUCIE COUNTY = Design Location: FL, Fort Pierce c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 6/15/2022 11:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Detached or multiple -family 2. Detached b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 48.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2733 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.225 14. Heating system: Capacity 34.0 c) Area 7c. 414.8 a) Split system heat -pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.99 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly, no airspace 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be eted basr�ed on installed code compliant features. Builder Signature: Date: (O o 02 Address of New Home: TRANQUILITY BASE LANE City/FL Zip: FORT PIERCE, FL 6/15/2022 11:27:01 AM EnergyGauge® USA 7.0.07 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1