Loading...
HomeMy WebLinkAboutLetter - Engineering345 Seahorse Terrace Ft. Pierce, FL This structure has been designed in accordance with the requirements of the 2014 Florida Building Code, Fifth Edition - Residential, Chapter 3, Section R301.2.1. The following wind load requirements, in accordance with 2014 Florida Building Code, Fifth Edition - Building, Chapter 16, Structural Design, Section 1609 and ASCE 7-10 were employed in the design of the structure: Ultimate Design Wind Speed (V„ It): 150 MPH 3-Sec6nd Gust Wind Speed (Vasa): 116 MPH Risk Category: I Wind Exposure Category: B Applicable Internal Pressure Coefficient: +/- 0.18 (Utility Shed) Design Pressure for Exterior Components & Cladding: • Walls = +21.8/-25.6 PSF • Roof = +8.5/-26.8 PSF Applicable Internal Pressure Coefficient: +/- 0.00 (Carport) Design Pressure for Exterior Components & Cladding: • Walls = N/A • Roof = +/-15.0 PSF Applicable Internal Pressure Coefficient: +/- 0.00 (Screen Room) Design Pressure for Exterior Components & Cladding: • Walls = +/- 18.6 PSF • Roof = +/-15.0 PSF TNg§# PLANS AN8 ALL PROPOSED WORK 4NE @U®JSC7 rO ANY CORRECTIONS K AVf3- SVFIELD INSPECTORS THAT comp SS NECESSARY IN ORDER TO �aAi�LY Y" ALL APPLICABLE CODES. CONCEg160 fASTFNEqe,� , ARETN,FgES�,ONSIBILliyOF �R�ENTS CONTR,gCTOR OFREC080 T HE Davis & Cleaton Engineering, Inc. 260 Wekiva Springs Road Suite # 1060 Longwood, FL 32779 FL P.E. License # 35816 �Jd - a/0 9 S'T. LUC?F' ANTY BL'ILnL!'C'DIVISION R.EVIER'ED FOR C Le REVIEWED Y�GJy DATE PLA\S A\ PERMIIT M ST BE KEPT ON JOB OR NO INSPECTION WILL BE yiADE. olZ� mie copy 345 Seahorse Terrace Ft. Pierce, FL WIND LOADS ON EXTERIOR OPENINGS OPENING SIZE TOTAL TOTAL POSITIVE NEGATIVE LENGTH OF LOAD PER LIN. AREA LOAD WIND LOAD WIND LOAD BUCK ATTACHMENT FT. OF BU. (Ft.2) (Lbs.) (PSF) (PSF) (In.) (LB. per FT.) Window 3'-0 x 3'-0" 9.0 312 25.9 34.7 108.00 Door T-0" x 6'-8" 20.0 648 24.7 32.4 196.00 1.) For exterior windows, use 1x4 P.T. buck on jambs and head. 2.) For exterior doors, use 2x4 (Min.) P.T. buck on jambs and head. 3.) For garage door use minimum 2x6 P.T. buck for jambs and required spring pads. 4.) Provide enough fasteners of type used to equal or exceed stated loads on table. Fasteners are required no closer than 2" or more than 4" from ends and spaced equal in distance along balance of buck. Minimum fasteners for top buck is 2. ** Minimum fasteners for side buck is 3. Approved Fasteners: 3/16 Tapcon with 1 %" penetration = 230 lb. of holding power. %4" Tapcon with 2" penetration = 380 lb. of holding power. See manufacturers specification for required fasteners to attach garage door, entry doors, patio doors and windows to building. Note: Garage door "bucks" shall be attached to studs with 3/8"x4" lag bolts. Spaced each 24" o.c. with minimum of 3 bolts. Davis & Cleaton Engineering, Inc. 260 Wekiva Springs Rd., Suite 1060 Longwood, FL 32779 Ph.# 407-539-2353 Licl 35816 35 40 i