Loading...
HomeMy WebLinkAboutProduct Approval Metal Roof. ' BCIS Home j Log In ; User Registration Hot Topics ! Submit Surcharge i Stats & Facts Publications FBC Staff BCIS Site Map : Links i Search i r.U4 U Product Approval 1.{1 USER: Public User Product Aooroval Menu > Product or Application Search > Application List > Application Detail FL # FL5500-R 4' Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Elite Aluminum Corporation Address/Phone/Email 4650 Lyons Technology Parkway Coconut Creek, FL 33073 (954) 949-3200 dk@dokimengineering.net Authorized Signature Frank Bennardo frank@engineeringexpress.com Technical Representative Bruce Peacock Address/Phone/Email 4650 Lyons Technology Parkway Coconut Creek, FL 33073 (954) 949-3200 bpeacock@elitealuminum.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Frank L. Bennardo, P.E. Evaluation Report Florida License PE-0046549 Quality Assurance Entity QAI Laboratories Quality Assurance Contract Expiration Date 12/31/2018 Validated By Jorge A. Pomerantz, P.E. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code EL5500 R4 COI Indep.pdf Florida Licensed Professional Engineer or Architect FL5500 R4 Equiv Equiv.Ddf 104.11.2 1709.3 Product Approval Method Method 2 Option B C Date Submitted 02/26/2015 Date Validated) 03/08/2015 Date Pending FBC Approval 03/09/2015 Date Approved 1 04/15/2015 FL # 1 Model, Number or Name Description 5500.1 1 Aluminum / Aluminum Roof Panels EPS Foam Core Composite Patio Roof Panels Limits of Use , Installation Instructions Approved for use In HVHZ: No FL5500 R4 II Dwg.Ddf Approved for use outside HVHZ: Yes Verified By: Frank L. Bennardo, P.E. PE0046549 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/P Evaluation Reports Other: For outdoor patio construction only. For use outside FL5500 R4 AE Eval.Ddf the HVHZ. See installation drawing for allowable span/load FL5500 R4 AE NOA 11092607.Ddf� combinations. FL5500 R4 AE Test Reports l.p�tf ` FL5500 _R4 AE Test_Reports__2_.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO`employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement ::,Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request; do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -pursuant to Section 455.27S (1), Florida Statutes, effective October 1, 71012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they -have one. The emails provided may be used for official con1munication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S„ please 1 click here Product Approval Accepts: Credit Card Safe I EPS FOAM CORE ROOF PANELS ALUMINUM / ALUMINUM SKIN MAXIM UM,ALLOWABLE CLEAR SPAN TART F-';' 1 3' Panels 4' Panels 8' Panels Live Load!Daifecl:on 0.024" 0.032^ 0.024- 1 0.032° 0.024• ! 0.032" 8for Uplift, Limit Alum Skill; Alum Skin Alum SkIWAlum Skin Alum Skin' Alum Skin _ 1 Ib EPS 1-Ib EPS 1 •Ib EPS 1-lb EPS Nf0'-0^ 1-lb EPS I 1-lb EPS Ps L/120 12 psf L 1120 14'-0. i 16'-3^ 13'-2" 15'-3• 1T-0" 17'42' i 23'-2^ 1 23'-0" /�^A•e,�� L1120 LI120 IT-7" 1 17••11" 17•-1" ! 17'-0" 21'-9" 22'S' 20•-R^ 21•.3" 18 psf L I120 1V-12" 3'-10" 11'-613'-4• 16'.q" ! f8•_3" 15'•8' I 15'S" tg•-10• 2g•-4- IT-O" I tq T• 20 psl L / 120 11'-2' l 12410" 15'-2' 15•_1" 18'-.4" 24 ps1 I L1120 28 PST i L 1120 10'-6" ? 12'-1' ta•.3• 14'-3" 1T-0° 1T•5" 32 psf1 L 1120 9'-11" 1 V-6' 9'.9" 11'-0° 13'-5' j 13'S" 12%6__, 12•7. 16'-5^ T' 15'S" I_ 15-.1" CLEAR SPAN TABLE USE INSTRUCTIONS: --'- --' 1. DETF,RMINF TYPE OF ENCLOSURE TO BE COVERED (OPEN, SCREENED WALLS, OR FULLY ENCLOSED). 2. D ' ' ETERMINE'I HE SITE SPECIFIC REQUIRED DE SIGN WIND PRESSURE PROVIDED BY SEPARATE ENGINEERING BY A LICENSED ENGINEER OR REGISTERED ARCHITECT, IN ACCORDANCE WITH THE FLORIDA BUILDING CODE FIFTH EDITION (2014). 3. FIND ALLO'.VABLE COMPOSITE PANEL CLEAR SPAN IN TABLES FOR.APPRCPRIATE PANEL DEPTH, FACING THICKNESS, AND EPS .__CORE DENSITY SELECTED_ `SEAL JOINT CONTINUOUS / CAULKING °oo o°oo°ooe000,°, oouoo o °°o°000°000 CROSS SECTION AT RYj(;AL"PANF iNTEMOCK EPS ROOF PANEL SPAN DETAIL: 0.024" OR 0.032" ALUM 4' MAX WIDTH PER INTERLOCKING PANEL. TOP & BOT"TOM FA__._.CINGS (1/4" PER FOOT MIN SLOPE) _::.-__ -CLEAR SPAN R) INSIDE TO INSIDE REFER TO ADDITIONAL ENGINEERING SHEETS FOR LOADS, RUOF CONNECTIONS, & SUPPORTING STRUCTURE DETAILS (BY OTHERS). THIS SHEET CERTIFIES ALLOWABLE ROOF SPANS ONLY. MAXTMI I AI I FNAIA RI F 1"1 GAD C M A n1 T 3- Pe La 4• Panels 6' P_an_els Live Loadpe8edlon 0.024" • 0.032' 0.024" 0.032" 0.02-0' 0.032' 81or Uplift Limit Alum Skln`Plum Skin Alum Skin' Skin Alum Skin: Alum Skin -lb 1-lb EPS , 1-Ib EPS 1-lb EPS 1 1-lb EPS 1-lb EPS 11-lb EPS 15 Pa( L / 180 10'•9" 12'-5' 14'- " ' 14'-8° 17'-W 18.4' I L1240 ....._........._....i.._._.._._... 9'-9•' ..........____....._..___._ 1V-3" 13'-3" 13'.2• f6'•1" 1 17 Psf I L1180 10.3" 11'•10" _^ _._..._...__.:_._....._............._. t3'-12' 13'N' 18'-11' i 1T•5" L/ 240 _......_._... .,..,.9'.4", _' 10'•9" .... 12'41' + .._..._ i.......�._..._.. 1T-R' 15.5" j. 1s'-1R' 20 psf L/180 9'•9" 11'-3" 13'�" 13'•2' ,. _._.-.... 18'-I• i 16'6' L/240 0'-10" 10'-3" 12'•0° i 1ILIK f4'-T' 14'-12' I L 1180 2a psf 9,•2 •� 7 •. 12'.y:.....:__._._.........._........_ : 12'-5' .:..........._._....... 15'-1" i 1_/240 8'•4" 9'•7" 11'-4" i 17'•3' IT-W 14'-l' 28 psf L/180.LL1R70'' 11 =t0' 14'4" 14'-9". L/240 T-11" 9'-2" 10'-9" 11'•7" 10'-0' 11'-6' 19'-0' 14'•0' 13'-5" id'-5".._. 30 psf 9'-10" 10'-6- 10'-6° 12'•9' 13'-v 32 psf ' ti'-3' ..._... .......j L / 240 7'-1" _._._..._. W-9" 10' 3 � 10'-3' 12'-8' 12'-10' 34 psf € L 1180 81•2" 9'-5" 11'•1° 1I'•1' 13'-5" 13'-10^ L, 240 10'-1' 1T-3" 72'-7" 37 psf 9 10'-9' 13'-1' t 13'-5' L 1240 7'-2' 8'4" 9'-10" 9'-9' 11'-11' 17-2° 40 of 180 P T-8" 0'-11" 10'•e' __ 10'-6' ...L1 240 T-0' 8'•1" 9'-T 9'-6' 11'-7° 11'•it' 44 psf L1180 T•6" 8'-8" tU•-2• It!'-2" 12'4°- 1...-d'..... .......... ._..... ....1._L/240. V-10" T-10" 1V-3• 11'•g, 48 psf L 1180 _0.3.9'-3' L/240 8 7 T-8' V-.2 R'it' 1n 1f 11%2' L 1180 sz psf 7 1 8'-2" 9'-7 9' 7... 11 S ..... .. 1 n-m Lf240 8 5 T-5" 8'-9 - W. f0 56 psf ! L/180 6'_71" T-12' 9'.5" i g•-0^ 1P•8' p 11,•5" ..... . _L / 240 6'J" 7'-0" R'-R" B'-A'• 10'-4" 60 psf 9" 7 10 9' 2 9'-2- 1 t •2 t 11=0 ! L / 240 6'-2" ' 7'-1" R'4' ' A'A' 10'•i' ': 10'S" DEFLECTION NOTFS' ......................... _... __........... __... _........................ _..__.._..--'^'-' 1. USE L/120 FOR ALL MEMBERS SUPPORTING ROOFS OVER AN OPEN OR SCREEN -WALLED ROOM. 2. USE L/180 FOR ALL MEMBERS SUPPORTING ROOFS WITH A NON -PLASTERED CEILING OVER AN ENCLOSED ROOM. 3. USE L/240 FOR ALI. MEMBERS SUPPORTING ROOFS WITH A PLASTERED CEILING OVER AN ENCLOSED ROOM, PER FLORIDA BUILDING CODE. FIFTH EDITION (2014) TABLE 1604.3. MAXIMUM ALLOWABLE DESIGN PRESSURES: AS NOTED IN CLEAR SPAN TABLES DESIGN NOTES: POSITIVE AND NEGATIVE DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED BY OTHERS ON A JOB -SPECIFIC BASIS IN ACCORDANCE PRESSURE REQV REMENTSI AS DETERMINETH THE D IN ACNG CORDANCE WITHIASCE 7-10 ANp CHAPTER Y609 OF THE FLORIDA BUILDING CODE FIFTH EDITION (2014) SHALL BE LESS THAN OR EQUAL TO THE POSITIVE OR NEGATIVE DESIGN PRESSURE CAPACITY VALUES LISTED HEREIN FOR ANY ASSEMBLY AS SHOWN. GENERAL NOTES: 1, THIS SPECIFICATION HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENOF THE FLORIDA BUILDING CODE FIFTH EDITION (2014) FOR USE OUT TSIDE THE HVHZ, COMPOSITE ROOF PANELS SHALL COMPLY WITH CHAPTER 7 SECTION 720, ER 26 SECTION 2603 OF THE ER 8 SECTION D FLORIDA DA BUILDING CODE FIFCLASS A INTERIOR FIN TH EDITIONAND �2014). CONTRACTOR SHALL INVESTIGATE AND CONFORM TO: ALL LOCAL BUILDING CODE AMENDMENTS WHICH MAY APPLY. DESIGN CRITERIA BEYOND AS STATED HEREIN MAY REQUIRE ADDITIONAL SITE -SPECIFIC SEALED ENGINEERING. 2. NO 33-1/3% INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THIS SYSTEM. 3. THE ARCHITECT/ENGINEER OF RECORD FOR THE PROJECT SUPERSTRUCTURE WITH WHICH THIS DESIGN IS USED SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PER CONTRACTOR. 4. SEPARATE'SITE-SPECIFIC' SEALED ENGINEERING SHALL BE ' REQUIRED IN ORDER TO DEVIATE FROM LOADS, DEFLECTIONS, OR SPANS CONTAINED HEREIN_ LINEAP. INTERPOLATION OF THE ALLOWABLE SPAN FROM THE CONDITIONS DETAILED HEREIN, .4 LICENSED ENGINEER OR REGISTERED' ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE IN CONJUNCTION WITH THIS DOCUMENT. 6, THE CONTRACTOR SMALL CAREFULLY CONSIDER POSSIBLE IMPOSING CK1 DI1gl4, tat PROPERLY ANALYZED BY A LICENSED ENGINEER OR REGISTERED.ARCHITFCT, 7. EPS CORE COMPOSITE PANELS SHALL BE CONSTRUCTED USING TYPE 3105-H1S4 ALUMINUM FACINGS. EXPANDED POLYSTYRENE FOAM SHALL HAVE TYPICAL DENSITY OF 1.0 PCF AND SHALL BE MANUFACTURED BY DYPLAST PRODUCTS, LLC PER MfAMFDAOE NOA #I1-0926.07 (OR CURRENT VERSION OF THIS NOA. THE EPS FOAM SHALL BE ADHERED TO THE ALUMINUM FACING WITH ISOGRIP SP 202 ADHESIVE (BY ASHLAND SPECIALTY). FABRICATION SHALL BE IN ACCORDANCE WITH APPPOVFn 8. THE CONTRACTOR IS RESPONSIBLE TO INSULATE OR PROTECT ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 9. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY, USC OF TI ITS SPECIFICATION BY CONTRACTOR, et. at, INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & 11 OTHER CONSIDERATIONS: DAMAGES INCLUDING LEGAL FEES&APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, & CONSTRUCTION PRACTICE! -••-- ---- .__ BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES J. FRONT OVERHANG MAY B[ UP TO 3'-0" WITH VALUES LISTED HEREIN. MAXIMUM & FROM DEVIATIONS OF T"HIS PLAN. UNSUPPORTED SIDE OVERHANG IS 25% OF LAST PANEL WIDTH i.e. 12" MAX FOR 48" 10. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL -PANEL WIDTH), ( CER'7IFICATIONS OR AFFIRMATIONS ARE INTENDED. 2:_. ROOF PITCH_SHALL BE AS PER.BUILDING CODE RE UIREMENTS 11. ALTERATIONS, ADDITIONS, HIGHLIGHTING,, OR OTHER MARKINGS TO ...._ _ ._._.............._..._. __4.THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE_ TFIIS OPTIONAL GUTTER OR DRIP CAP OVERHANG 1 36" MAX 0/11 AT FRONT & 2S i OF LAST PANEL WIDTH AT SIDES (UP TO 12- MAX O/H AT SIDES) TABLE VALUE DERIVATIONS: PANELPROPERTIES: 1. PA�f• E-L STRUCTURAL PROPERTIES DERIVED FROM CERTIFIED TEST REPORTS Nos. METI-05-1985,-OS-1981,-05"1968,-05-1989, -OS-1990,-OS-1991,-OS-1992,-OS-1993,-05-1994,-05-1995, -05-1996,-05-1997,-06-2066,-06-2067,-06-2068,-06.2069, -06-2070,-06-2071,-06-2072,-06-2073, &-06-2074 BY HURRICANE ENGINEERING & TESTING, Inc. 2. PANEL DEAD LOADS HAVE BEEN FACTORED INTO CALCULATIONS FOR GRAVITY LOADS AS WELL AS CALCULATIONS FOR PANEL PROPERTIES. 14-1438