PAUL WELCH INC.
Mechanical Electrical Civil Engineering
1.984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (712) 785 - 9888
Email pwelchinc@aol.com
February 14, 2018
Re: Residential Roof
3191 Daniels St.
Fort Pierce, FL
Permit# 1711-0123
To Whom It May Concern:
Please be advised our office has inspected the roofing installations for the above
referenced address low sloped roof at the right side of the residence and find that it has
been installed as per the requirements of the Florida Building Code 2014, and with our
Engineering requirements for this project.
Inspections Include: Underlayment / Flashing / Base Sheet Attachment
Roofing: Certainteed Modified Bitumen Roofing (NOA# 14-0529.02)
System Type E(3) page 23 of 42
Thank you for your attention to this matter. If you should have any questions or concerns,
please do not hesitate to contact our office.
Submitted by:
PAUI WELCH INC.
'Paul fech, P.E.
;-.Reg. No 29945
PW;PJ
PAUL WELCH INC.
Mechanical Electrical Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Email pwelchinc@aol.com
February 14, 2018
Re: Residential Roof
3191 Daniels St.
Fort Pierce, FL
Permit# 1711-0123
To Whom It May Concern:
Please be advised our office has inspected the roofing installations for the above
referenced address sloped roof of the residence and find that it has been installed as per
the requirements of the Florida Building Code 2014, and with our Engineering
requirements for this project.
Inspections Include: Metal Fasteners / In -Progress
Roofing:
Extreme Metal Fabricators, LLC, Standing Seam 1" Nail Strip (FL#17022.5)
Thank you for your attention to this matter. If you should have any questions or concerns,
please do not hesitate to contact our office.
8
Submittd by: '
PAULWELCH INC.
Paul We ch, P.E.
Reg. No 29945
PW:pj
v
o
KC —Inspections
i
St. Lucie Count �
Click here to return to the main Permits page.
Permit: 1711-0123
Permit Status: Issued
Job Description: REMOVE ALL EXISTING ROOF COVERINGS AND INSTALL " EXTREME METAL " 1" NAIL STRIP [ FL# 17022.5 OVER STANDARD 30 LB FELT
UNDERLAYMENT AND CERTAINTEED MODIFIED ROOF SYSTEM TYPE E [3] FOR FLAT ROOF AREA COVERING [ N.O.A. # 14-0529.02 ] . 1136 SQ FT 4/12 PITCH.
To pay a reinspection fee, please click PavFee link for each fee due. You may use Visa, Mastercard, Discover Card,
or echeck to pay the fee using the Govteller gateway.
To schedule an inspection, please select Request for each inspection you would like to schedule. Inspections must be scheduled in the order of the Priority listed below. An inspection will
not schedule until all inspections with a lower Priority number show an "Approved" status and ALL reinspection fees have been PAID.
To add a note for the Inspector for scheduled inspections, please select Add Noteenter note in Inspection Notes textbox below, and click Update link for each inspection you would lik
to add a note for.
If you are unable to schedule an inspection or require any assistance, please contact the Building Division at (772) 462-2172.
Type Certk
Status Permit Type
Name Company
Phone Faz
Cell
Contractor 25387
Active I ROOF - MODIFIED BITUMEN
3AMIE CISCO SUNSHINE ROOFING LLC
(772) 260-8195
Request
Add Note
Pay Fee
Fee
Code
Status Priority
Date Scheduled
Date Inspected
Insp. ID Comments
Inspection
Notes
Add Note
Pay Fee
SHEATHING
Approved 1
1/8/2018
1/8/2018
0
162-ROOF
Add Note
Pay Fei!
AFFIDAVIT —TURN
Approved 1
1 1/8/2018
1/8/2018
0
INTO OFFICE
!
30 LB: ON SLOPES AND E (3] BASE SHEET
Add Note
Pay Fee
136-ROOF DRY-
Accepted as
2
1/9/2018
1/9/2018
MECHANIWlY ATTACHED PER
237
IN/TIN TAB
noted
! ENGINEERS REPORT ON FLAT AREA.
Sloped roof is approved.
Add Nece
Pay Fer-
904
4-FASTNERS
Disapproved � 2
I 1/9/2018
1/9/2018
237 �. for
_.. .......
...... ....
..y
......
I ...I . . .. .......
..._.. .........
Disapproved-
........._._ _.... ........
.,........ ........
--
.--._..._....
nd dote
Pa Fey
904 - FASTNERS
i Reinspect Fee 2
1/18/2018
1/18/2018
39
t...I
Required
_
Add Note
Pay Fee
(I�FASTNERS
j i 2
i
Request
RENSPECTION.
An,. NotL
Pay Fee
149 - PROGRESS
i
Disapproved I 3
I 1/18/2018
1/18/2018
ROOF METAL FASTENERS. No one on site
39
INSPECTION
{
i—! no panels installed
_-.._.....---._......
.....
Ado Note
pay Fee
149 -PROGRESS
i 3
I
RENSPECTION.
INSPECTION
i
Add Ploie.
Pay Fee
999 INSPECTION FINAL
4
Another Permit
[-''7—
(fe %0
"000=0*11,0
http://codeinspectionpublic.stiucieco.gov/ 1/1