HomeMy WebLinkAboutapproved Energy Calcs_Ravinia 3A GL permit #2202-0389PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
1
Ravinia 3A - Left Hand Garage
Ravina 3A
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle: 180
Yes
1
1450
3
New (From Plans)
Detached
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
Port St. Lucie ,
St. Lucie
Garage Left
Street Address
Comment:
Building Type: User
Cross Ventilation: No
Whole House Fan: No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 1450 11600
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 M Bedroom 195 1560 No 2 1 Yes Yes1 Yes
2M WIC 48384No0 Yes Yes1No
3 M Bath 84 672 No 1 Yes Yes1 Yes
4 Bedroom 3 143 1144 No 1 1 Yes Yes1 Yes
5 Bath 2 54 432 No 0 Yes Yes1 Yes
6 Bedroom 2 143 1144 No 1 1 Yes Yes1 Yes
7 Great Room 232 1856 No 2 Yes Yes1 Yes
8Dining 1281024No2 Yes Yes1 Yes
9 Kitchen 202 1616 Yes 2 Yes Yes1 Yes
10 Foyer 85 680 No 1 Yes Yes1 Yes
11 Hall 1 35 280 No 0 Yes Yes1No
12 Laundry 77 616 No 0 Yes Yes1 Yes
13 Hall 2 24 192 No 0 Yes Yes1No
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1195 ft² 100______ Slab-On-Grade Edge Insulatio - - - -32 ft M Bedroom
248 ft² 100______ Slab-On-Grade Edge Insulatio - - - -1 ft M WIC
384 ft² 100______ Slab-On-Grade Edge Insulatio - - - -6 ft M Bath
4143 ft² 100______ Slab-On-Grade Edge Insulatio - - - -11 ft Bedroom 3
3/6/2022 8:32 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
554 ft² 100______ Slab-On-Grade Edge Insulatio - - - -6 ft Bath 2
6143 ft² 100______ Slab-On-Grade Edge Insulatio - - - -11 ft Bedroom 2
7232 ft² 100______ Slab-On-Grade Edge Insulatio - - - -30 ft Great Room
8128 ft² 100______ Slab-On-Grade Edge Insulatio - - - -8 ft Dining
9202 ft² 100______ Slab-On-Grade Edge Insulatio - - - -12 ft Kitchen
10 85 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -19 ft Foyer
11 35 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Hall 1
12 77 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -11 ft Laundry
13 24 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Hall 2
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1Hip Composition shingles1571 ft² Medium 0.6 022.62______ No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Vented 1450 ft² N N150
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Vented) 30 195 ft² 0.1 Wood______ M Bedroom Batt
2 Under Attic (Vented) 30 48 ft² 0.1 Wood______ M WIC Batt
3 Under Attic (Vented) 30 84 ft² 0.1 Wood______ M Bath Batt
4 Under Attic (Vented) 30 143 ft² 0.1 Wood______ Bedroom 3 Batt
5 Under Attic (Vented) 30 54 ft² 0.1 Wood______ Bath 2 Batt
6 Under Attic (Vented) 30 143 ft² 0.1 Wood______ Bedroom 2 Batt
7 Under Attic (Vented) 30 232 ft² 0.1 Wood______ Great Room Batt
8 Under Attic (Vented) 30 128 ft² 0.1 Wood______ Dining Batt
9 Under Attic (Vented) 30 202 ft² 0.1 Wood______ Kitchen Batt
10 Under Attic (Vented) 30 85 ft² 0.1 Wood______ Foyer Batt
11 Under Attic (Vented) 30 35 ft² 0.1 Wood______ Hall 1 Batt
12 Under Attic (Vented) 30 77 ft² 0.1 Wood______ Laundry Batt
13 Under Attic (Vented) 30 24 ft² 0.1 Wood______ Hall 2 Batt
3/6/2022 8:32 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
14.1 0M Bedroom 00014 8N=>S Concrete Block - Int Insul 0.40Exterior 112.0 ft² ____
24.1 0M Bedroom 00018 8W=>E Concrete Block - Int Insul 0.40Exterior 144.0 ft² ____
34.1 0M Bath 00068W=>E Concrete Block - Int Insul 0.40Exterior 48.0 ft² ____
44.1 0Bedroom 3 00011 8W=>E Concrete Block - Int Insul 0.40Exterior 88.0 ft² ____
54.1 0Bath 2 00068W=>E Concrete Block - Int Insul 0.40Exterior 48.0 ft² ____
64.1 0Bedroom 2 00011 8W=>E Concrete Block - Int Insul 0.40Exterior 88.0 ft² ____
74.1 0Great Room 00016 8N=>S Concrete Block - Int Insul 0.40Exterior 128.0 ft² ____
84.1 0Great Room 00014 8E=>W Concrete Block - Int Insul 0.40Exterior 112.0 ft² ____
94.1 0Dining 00088E=>W Concrete Block - Int Insul 0.40Exterior 64.0 ft² ____
10 4.1 0Kitchen 00012 8E=>W Concrete Block - Int Insul 0.40Exterior 96.0 ft² ____
11 4.1 0Foyer 00088E=>W Concrete Block - Int Insul 0.40Exterior 64.0 ft² ____
12 4.1 0Foyer 00010 8S=>N Concrete Block - Int Insul 0.40Exterior 80.0 ft² ____
13 4.1 0Foyer 00018W=>E Concrete Block - Int Insul 0.40Exterior 8.0 ft² ____
14 4.1 0Laundry 00011 8E=>W Concrete Block - Int Insul 0.40Exterior 88.0 ft² ____
15 13 0Laundry 7 8N=>S Frame - Wood 0.40.23Garage 56.0 ft² ____
16 13 0Bedroom 2 13 8N=>S Frame - Wood 0.40.23Garage 104.0 ft² ____
# Door Type U-Value AreaStorms
DOORS
Ornt Space
Width
Ft In Ft In
Height
1Insulated .39 20.5 ft² None______ S=>N Foyer 1063
2Insulated .39 17.8 ft² None______ N=>S Laundry 8682
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered orientation (=>) changed to Worst Case.
Wall
ID Imp
1N=>S Low-E Single 0.39 0.29 20.0 ft² 1 ft 5 in 1 ft 4 in NoneVinyl None______ Yes1Y
2 W=>E Low-E Single 0.39 0.29 15.0 ft² 1 ft 5 in 1 ft 4 in NoneVinyl None______ Yes4Y
3 W=>E Low-E Single 0.39 0.29 15.0 ft² 1 ft 5 in 1 ft 4 in NoneVinyl None______ Yes6Y
4N=>S Low-E Single 0.39 0.29 41.0 ft² 1 ft 5 in 1 ft 4 in NoneVinyl None______ Yes7Y
5 E=>W Low-E Single 0.39 0.29 20.0 ft² 1 ft 5 in 1 ft 4 in NoneVinyl None______ Yes9Y
6 E=>W Low-E Single 0.39 0.29 15.0 ft² 1 ft 5 in 1 ft 4 in NoneVinyl None______ Yes11 Y
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1400 ft² 400 ft² 20 ft 8 ft 11______
3/6/2022 8:32 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
966.7 553.03.000254Wholehouse .090299.57Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtype BlockSpeed
1 Electric Strip Heat/ COP:1 27 kBtu/hr ______ sys#1None 1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtype BlockSubtype
1 Central Unit/ SEER: 14 28.6 kBtu/hr c f m 0.7______ sys#1Split 1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1Electric 0.95 50 gal 60.9 gal 120 deg None______ None Garage
FSEC
Company Name System Model # Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert # Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply ---- ---- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 75 ft² Foyer 10 ft² Proposed Qn Foyer 116.0 cfm 0.08 0.50______ 1 1 --- cfm
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting
3/6/2022 8:32 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD) AMPM 7880 7880 7880 7880 7878 7878 7878 7878 8078 8078 8078 8078
Cooling (WEH) AMPM 7880 7880 7880 7880 7878 7878 7878 7878 8078 8078 8078 8078
Heating (WD) AMPM 6568 6568 6568 6568 6568 6568 6568 6868 6868 6868 6868 6868
Heating (WEH) AMPM 6568 6568 6568 6568 6568 6568 6568 6868 6868 6868 6868 6868
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 M Bedroom
Default(8 lbs/sq.ft. f t ² f t 0.3 M WIC
Default(8 lbs/sq.ft. f t ² f t 0.3 M Bath
Default(8 lbs/sq.ft. f t ² f t 0.3 Bedroom 3
Default(8 lbs/sq.ft. f t ² f t 0.3 Bath 2
Default(8 lbs/sq.ft. f t ² f t 0.3 Bedroom 2
Default(8 lbs/sq.ft. f t ² f t 0.3 Great Room
Default(8 lbs/sq.ft. f t ² f t 0.3 Dining
Default(8 lbs/sq.ft. f t ² f t 0.3 Kitchen
Default(8 lbs/sq.ft. f t ² f t 0.3 Foyer
Default(8 lbs/sq.ft. f t ² f t 0.3 Hall 1
Default(8 lbs/sq.ft. f t ² f t 0.3 Laundry
Default(8 lbs/sq.ft. f t ² f t 0.3 Hall 2
3/6/2022 8:32 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction:Ravinia 3A - Left Hand Garage
Ravina 3A
Street:
City, State, Zip: Port St. Lucie , FL ,
Garage Left
Permit Number:
Design Location: FL, Fort Pierce CHECKAIR BARRIER CRITERIA
A continuous air barrier shall be installed in the building envelope.
The exterior thermal envelope contains a continuous air barrier.
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
the insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall be sealed.
The junction of the top plate and the top of exterior walls shall be
sealed.
Knee walls shall be sealed.
The space between window/door jambs and framing, and
skylights and framing shall be sealed.
Rim joists shall include the air barrier.
The air barrier shall be installed at any exposed edge of
insulation.
Exposed earth in unvented crawl spaces shall be covered with
a Class I vapor retarder with overlapping joints taped.
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Narrow cavities
Shafts, penetrations
Crawl space walls
Floors
(including
above-garage
and cantilevered
floors)
Rim joists
Windows, skylights
Walls
Ceiling/attic
General
COMPONENT
Garage separation
Recessed lighting
Plumbing and wiring
S h o w e r / t u b
HVAC register boots HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub-floor, wall covering or
The air barrier shall be installed behind electrical or communication
boxes or air-sealed boxes shall be installed.
The air barrier installed at exterior walls adjacent to showers and
tubs shall separate them from the showers and tubs.
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Recessed light fixtures installed in the building thermal envelope
shall be sealed to the finished surface.
Air sealing shall be provided between the garage and conditioned spaces.
When required to be sealed, concealed fire sprinklers shall only be
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ceilings.
C o n c e a l e d
Electrical/phone box on
exterior walls
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
INSULATION INSTALLATION CRITERIA
EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software3/6/2022 8:34 PM Page 1 of 1
Air-permeable insulation shall
not be used as a sealing material.
The insulation in any dropped ceiling/soffit
shall be aligned with the air barrier.
Cavities within corners and headers of frame walls
shall be insulated by completely filling the cavity
with a material having a thermal resistance of R-3
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Rim joists shall be insulated.
Floor framing cavity insulation shall be installed to
maintain permanent contact with the underside of
subfloor decking, or floor framing cavity insulation
shall be permitted to be in contact with the top side
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
and doors
on exterior wall
requirements
Recessed light fixtures installed in the building
thermal envelope shall be air tight and IC rated.
sprinklers
Where provided instead of floor insulation, insulation
shall be permanently attached to the crawlspace walls.
Exterior walls adjacent to showers and tubs shall
be insulated.
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
a