Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
approved Manual J_Ravinia 3A GL
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 16:04:01Right-Suite® Universal 2021 21.0.10 RSU08101 Page 1...ucie County - Ravina 3A - Letft Hand Garage.rup Calc = MJ8 Front Door faces: N Job:Project Summary Date:Entire House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com Project Information Ravinia 3A - Left Hand GarageFor:Garage Left, Port St. Lucie, FL Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75Design TD °F28 Design TD °F15Daily range MRelative humidity %50Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh15504 Structure Btuh15614DuctsBtuh4193DuctsBtuh5106Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0(none)(none)Humidification Btuh0 Blower Btuh0PipingBtuh0Equipment load Btuh19696 Use manufacturer's data nRate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh19684 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Average0Fireplaces Structure Btuh4258DuctsBtuh1589Central vent (0 cfm)Btuh0CoolingHeating(none)14501450Area (ft²)Equipment latent load Btuh58461160011600Volume (ft³)Air changes/hour 0.230.45 Equipment Total Load (Sen+Lat)Btuh25530Equiv. AVF (cfm)4487 Req. total capacity at 0.70 SHR ton2.3 Heating Equipment Summary Cooling Equipment Summary Make Make RuudTradeTradeRUUDModelCondRA1430AJ1NAAHRI ref Coil RH1P3017STANJAAHRI ref 7491225Efficiency100 EFF Efficiency 11.5 EER, 14 SEERHeating input kW5.7 Sensible cooling Btuh20020Heating output Btuh19575 Latent cooling Btuh8580Temperature rise °F19 Total cooling Btuh28600Actual air flow cfm953 Actual air flow cfm953Air flow factor cfm/Btuh0.048 Air flow factor cfm/Btuh0.046Static pressure in H2O0.50 Static pressure in H2O0.50Space thermostat Load sensible heat ratio 0.78 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 16:04:01Right-Suite® Universal 2021 21.0.10 RSU08101 Page 1...ucie County - Ravina 3A - Letft Hand Garage.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Entire House M Bedroom 2 Exposed wall 146.0 ft 32.0 ft3Room height 8.0 ft 8.0 heat/coolft 4 Room dimensions ft195.0x1.0 5 Room area 1450.0 ft²195.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 240 179 718 392 112 92 368 201.GG 1A-r1ov1A-r1ov 0.9000.900 nn 25.2025.20 19.7919.79 20 0 504 396 20 0 504 396.GG 1A-r1ovd1A-r1ovd 0.9000.900 nn 25.2025.20 19.7919.79 41 0 1028 807 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 424 389 1558 851 0 0 0 0 11 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 42.3342.33 15 0 378 635 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 42.3342.33 20 0 504 847 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 80 60 239 130 0 0 0 0DD11D011D00.3900.390 ss 10.9210.92 10.3410.34 20 20 223 211 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 424 394 1578 862 144 144 577 315GG1A-r1ov1A-r1ov 0.9000.900 ww 25.2025.20 42.3342.33 30 0 756 1270 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 1450 1450 1299 2320 195 195 175 312FF22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 1450 146 4043 0 195 32 886 0 6 c) AED excursion 0 -64 Envelope loss/gain 12826 8721 2510 1160 12 a)Infiltration 2677 733 587 161 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 12 2760 2 460 Appliances/other 3400 0 Subtotal (lines 6 to 13)15504 15614 3097 1781 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal155041561430971781 15 Duct loads 27%33%4193 5106 27%33%837 582 Total room load 19696 20720 3934 2363 Air required (cfm)Air required (cfm)953 953 190 109 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 16:04:01Right-Suite® Universal 2021 21.0.10 RSU08101 Page 2...ucie County - Ravina 3A - Letft Hand Garage.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name M WIC M Bath 2 Exposed wall 0 ft 6.0 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft6.0x8.0 ft6.0x14.0 5 Room area 48.0 ft²84.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0.GG 1A-r1ov1A-r1ov 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0.GG 1A-r1ovd1A-r1ovd 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0 11 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 42.3342.33 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 42.3342.33 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0DD11D011D00.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 48 48 192 105GG1A-r1ov1A-r1ov 0.9000.900 ww 25.2025.20 42.3342.33 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 48 48 43 77 84 84 75 134FF22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 48 0 0 0 84 6 166 0 6 c) AED excursion -3 -17 Envelope loss/gain 43 74 434 222 12 a)Infiltration 0 0 110 30 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13)43 74 544 482 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal4374544482 15 Duct loads 27%33%12 24 27%33%147 158 Total room load 55 98 691 640 Air required (cfm)Air required (cfm)3 5 33 29 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 16:04:01Right-Suite® Universal 2021 21.0.10 RSU08101 Page 3...ucie County - Ravina 3A - Letft Hand Garage.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Bedroom 3 Bath 2 2 Exposed wall 11.0 ft 6.0 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft11.0x13.0 ft6.0x9.0 5 Room area 143.0 ft²54.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0.GG 1A-r1ov1A-r1ov 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0.GG 1A-r1ovd1A-r1ovd 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0 11 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 42.3342.33 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 42.3342.33 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0DD11D011D00.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 88 73 292 160 48 48 192 105GG1A-r1ov1A-r1ov 0.9000.900 ww 25.2025.20 42.3342.33 15 0 378 635 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 143 143 128 229 54 54 48 86FF22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 143 11 305 0 54 6 166 0 6 c) AED excursion 204 -8 Envelope loss/gain 1103 1227 407 184 12 a)Infiltration 202 55 110 30 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1305 1512 517 214 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution81491614Subtotal13131526526230 15 Duct loads 27%33%355 499 27%33%142 75 Total room load 1668 2025 668 305 Air required (cfm)Air required (cfm)81 93 32 14 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 16:04:01Right-Suite® Universal 2021 21.0.10 RSU08101 Page 4...ucie County - Ravina 3A - Letft Hand Garage.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Bedroom 2 Great Room 2 Exposed wall 11.0 ft 30.0 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft11.0x13.0 ft232.0x1.0 5 Room area 143.0 ft²232.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 128 87 349 191.GG 1A-r1ov1A-r1ov 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0.GG 1A-r1ovd1A-r1ovd 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 41 0 1028 807 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 112 112 448 245 11 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 42.3342.33 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 42.3342.33 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0DD11D011D00.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 88 73 292 160 0 0 0 0GG1A-r1ov1A-r1ov 0.9000.900 ww 25.2025.20 42.3342.33 15 0 378 635 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 143 143 128 229 232 232 208 371FF22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 143 11 305 0 232 30 831 0 6 c) AED excursion 204 -108 Envelope loss/gain 1103 1227 2864 1506 12 a)Infiltration 202 55 550 151 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 2 460 Appliances/other 0 900 Subtotal (lines 6 to 13)1305 1512 3414 3017 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution6110014Subtotal1311152334143017 15 Duct loads 27%33%354 498 27%33%923 987 Total room load 1665 2021 4338 4004 Air required (cfm)Air required (cfm)81 93 210 184 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 16:04:01Right-Suite® Universal 2021 21.0.10 RSU08101 Page 5...ucie County - Ravina 3A - Letft Hand Garage.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Dining Kitchen 2 Exposed wall 8.0 ft 12.0 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft8.0x16.0 ft202.0x1.0 5 Room area 128.0 ft²202.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0.GG 1A-r1ov1A-r1ov 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0.GG 1A-r1ovd1A-r1ovd 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 64 44 176 96 96 96 384 210 11 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 42.3342.33 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 42.3342.33 20 0 504 847 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0DD11D011D00.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0GG1A-r1ov1A-r1ov 0.9000.900 ww 25.2025.20 42.3342.33 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 128 128 115 205 202 202 181 323FF22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 128 8 222 0 202 12 332 0 6 c) AED excursion -33 -106 Envelope loss/gain 1016 1115 898 428 12 a)Infiltration 147 40 220 60 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 2 460 2 460 Appliances/other 0 2000 Subtotal (lines 6 to 13)1163 1615 1118 2948 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution0091514Subtotal1163161511262963 15 Duct loads 27%33%315 528 27%33%305 969 Total room load 1478 2143 1431 3932 Air required (cfm)Air required (cfm)72 99 69 181 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 16:04:01Right-Suite® Universal 2021 21.0.10 RSU08101 Page 6...ucie County - Ravina 3A - Letft Hand Garage.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Foyer Hall 1 2 Exposed wall 19.0 ft 0 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft85.0x1.0 ft7.0x5.0 5 Room area 85.0 ft²35.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0.GG 1A-r1ov1A-r1ov 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0.GG 1A-r1ovd1A-r1ovd 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 64 49 196 107 0 0 0 0 11 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 42.3342.33 15 0 378 635 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 42.3342.33 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 80 60 239 130 0 0 0 0DD11D011D00.3900.390 ss 10.9210.92 10.3410.34 20 20 223 211 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 8 8 32 18 0 0 0 0GG1A-r1ov1A-r1ov 0.9000.900 ww 25.2025.20 42.3342.33 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 85 85 76 136 35 35 31 56FF22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 85 19 526 0 35 0 0 0 6 c) AED excursion -53 -2 Envelope loss/gain 1670 1184 31 54 12 a)Infiltration 348 95 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)2018 2009 31 54 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution1221-31 -5414Subtotal2031203000 15 Duct loads 27%33%549 664 27%33%0 0 Total room load 2580 2694 0 0 Air required (cfm)Air required (cfm)125 124 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 16:04:01Right-Suite® Universal 2021 21.0.10 RSU08101 Page 7...ucie County - Ravina 3A - Letft Hand Garage.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Laundry Hall 2 2 Exposed wall 11.0 ft 0 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft11.0x7.0 ft6.0x4.0 5 Room area 77.0 ft²24.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0.GG 1A-r1ov1A-r1ov 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0.GG 1A-r1ovd1A-r1ovd 0.9000.900 nn 25.2025.20 19.7919.79 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 88 88 352 193 0 0 0 0 11 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 42.3342.33 0 0 0 0 0 0 0 0 GG 1A-r1ov1A-r1ov 0.9000.900 ee 25.2025.20 42.3342.33 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0DD11D011D00.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0GG1A-r1ov1A-r1ov 0.9000.900 ww 25.2025.20 42.3342.33 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 77 77 69 123 24 24 22 38FF22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 77 11 305 0 24 0 0 0 6 c) AED excursion -13 -1 Envelope loss/gain 726 303 22 37 12 a)Infiltration 202 55 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)928 358 22 37 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution915-22 -3714Subtotal93637300 15 Duct loads 27%33%253 122 27%33%0 0 Total room load 1190 495 0 0 Air required (cfm)Air required (cfm)58 23 0 0 2022-Jan-12 16:04:02 Right-Suite® Universal 2021 21.0.10 RSU08101 Page 1 ...ucie County - Ravina 3A - Letft Hand Garage.rup Calc = MJ8 Front Door faces: N Job:Duct System Summary Date:Entire House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com Project Information Ravinia 3A - Left Hand GarageFor: Garage Left, Port St. Lucie, FL CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.250 / 0.250 in H2O in H2O0.250 / 0.250 Lowest friction rate in/100ft0.296in/100ft0.296 Actual air flow cfm953cfm953 Total effective length (TEL)ft169 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk 95.012.4VlFx0x04.00.4661432668hBath 2 95.013.6VlFx0x07.00.46093812021cBedroom 2 st2115.017.8VlFx0x07.00.37693812025cBedroom 3 st1115.016.5VlFx0x07.00.38099722143cDining 95.05.8VlFx0x07.00.4961241252580hFoyer st3135.031.2VlFx0x07.00.301921052169hGreat Room st3135.031.2VlFx0x07.00.301921052169hGreat Room-A st1115.016.5VlFx0x08.00.380181693932cKitchen 95.08.5VlFx0x05.00.48323581190hLaundry st2115.017.1VlFx0x04.00.3792933691hM Bath st4135.029.3VlFx0x06.00.30454951967hM Bedroom st4135.033.7VlFx0x06.00.29654951967hM Bedroom-A st4135.028.8VlFx0x04.00.3055398cM WIC Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st2 Peak AVF 307 236 0.296 563 10.0 0x0 VinlFlx st1 Peak AVF 351 464 0.301 590 12.0 0x0 VinlFlx st4 Peak AVF 193 113 0.296 553 8.0 0x0 VinlFlx st2 st3 Peak AVF 210 184 0.301 601 8.0 0x0 VinlFlx st1 2022-Jan-12 16:04:02 Right-Suite® Universal 2021 21.0.10 RSU08101 Page 2 ...ucie County - Ravina 3A - Letft Hand Garage.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb1 0x 9530 953 0 0 0 0 x0 0 VlFx