Loading...
HomeMy WebLinkAboutDrawing TrussIMPORTANT NOTES yV_ L ra EJ3 EJ3 EJ3 EJ3 CJ 1 NO BACK CHARGES WITHOUT PRIOR APPROVAL FROM A REPRE=SENTATIVE OF TJ TRUSS CORP. 2 2' 2' ,r 2' 2' 2' 2' 0 2' 2' 2' '° 2' 2' 2' 2' 4/12 17 cv a cv 3' 0 4/12 - - I U co L Q <C Q Q Q Q Q Q Q Q Q Q 40' ABBREVIATIONS BLDR = BUILDER HGR= HANGER GDR= GIRDER CLG= CELING T.O.B.= TOP OF BEARING LAYOUT SCALE: 1/4" = 1'-0" 3D VIEW CJ 1 EJ3 EJ3 EJ3 EJ3 CJ1 Q Q L M U y�Q Q f,I Q TYP PITCH ;w,j TYP HEE TYP OH TYP END DETAIL :-'iJCEALEO RS T ENEAS OR ATTACHMENT;; A�E THE rr ESP NSh fl IT_' OF T HF ti17'1AI 'i'OR QF RFCpRi! THESE PLANS AND AU PROPOSED WOI?I( ARE SE,1jECT TO ANY CORRECTIONS CCOMPLY.AEQUfRE'D BY FIELD INSPECTORS THAT COMPLY. NECESSARY IN ORDER TO ,: WITHALL APPLICABLE CODES, MEAL FOR TRUSS PLACEMENT ONL a- m JEC I ' .nyd.npcjz,h✓ TJ TRUSS PROVIDES STANDARD TRUSS TO TRUSS CONNECTIONS. ALL STRAPS AND UPLIFT TIEDOWNS TO FLAT GIRDERS, BEAMS,WALLS AND JACKS ARE SUPPLIED BY THE BUILDER. DRAWN WALLS ARE BEARING UNLESS OTHERWISE NOTED. ALL UNDERFRAMING OF DROPPED CEILINGS AND FINISH FRAMING OF SPECIAL CEILINGS IS BY BUILDER. TJ TRUSS IS NOT RESPONSIBLE FOR TEMPORARY BRACING OF THE ROOF SYSTEM. FOR TEMPORAY AND PERMANENT BRACING REQUIREMENTS SEE BCSI 1-03 GUIDE BRACING REQUIRED BY THE INDIVIDUAL TRUSS/WEB COMPONENTS IS TO OVERCOME BENDING OF SPECIFIC COMPRESSION MEMBERS DUE TO GRAVITY OR WIND LOADS AND SHOULD NOT BE CONFUSED WITH THE BRACING REQUIREMENTS OF THE BUILDING STRUCTURE, AND SHALL BE INSTALLED BY BUILDER. TJ TRUSS DISCLAIMERS: FOR ANY CONFLICT BETWEEN THIS SETTING PLAN AND THE INDIVIDUAL ENGINEERED DRAWINGS, THE INDIVIDUAL ENGINEERED DRAWING WILL TAKE PRECEDENCE. DO NOT CUT OR ALTER ANY TRUSS WITHOUT CONSULTING A REPRESENTATIVE OF TJ TRUSS FIRST. ANY PARTY WHO CUTS OR DAMAGES A TRUSS SHALL BE RESPONSIBLE FOR THE COST OF THE REQUIRED ENGINEERING DESIGN AND REPAIR OF THE TRUSS. NO BACK CHARGES WILL BE ACCEPTED UNLESS APPROVED IN WRITING BY AN OFFICER OF TJ TRUSS CORP. FAILURE TO SEEK THE RESOLUTION OF A PROBLEM UNTIL AFTER THE ROOF IS SHINGLED OR THE DRY WALL IS INSTALLED SHALL CONSTITUTE ACCEPTANCE OF THE PROBLEM BY THE CUSTOMER AND THE CUSTOMER SHALL BEAR TOTAL FINANCIAL RESPONSIBILTY TO RESOLVE THE PROBLEM. CUSTOMER RESPONSIBILTY: PROVIDE AND INSTALL ANY AND ALL PERMANENT BRACING REQUIRED BY THE TRUSS DESIGNS. PROVIDE A SUITABLE UNOBSTRUCTED AREA TO UNLOAD TRUSSES. TO ERECT ALL TRUSS COMPONENTS IN ACCORDANCE WITH THE TRUSS PLATE INSTITUTE PUBLICATION BCSI AND TO SEEK PROFESSIONAL HELP AND ADVICE ON ANY QUESTIONS PRIOR TO THE ERECTION OF THE TRUSSES. FLORIDA ADM. CODE 61G15-23.002 COMPLIANCE NOTE: THIS TRUSS PLACEMNT DIAGRAM WAS NOT CREATED BY AN ENGINEER, BUT RATHER BY THE TJ TRUSS CORP STAFF AND IS PURELY TO BE USED AS AN INSTALALTION GUIDE AND DOES NOT REQUIRE A SEAL. COMPLETE TRUSS ENGINEERING AND ANALYSIS CAN BE FOUND ON THE TRUSS DESIGN DRAWINGS WHICH MAY BE SEALED BY THE TRUSS DESIGN ENGINEER. LOADING CRITERIA ROOF FLOOR TCLL: 20 PSF TCLL: 0 PSF TCDL: 7 PSF TCDL: 0 PSF BCLL: 10 PSF BCLL: 0 PSF BCDL: 5 PSF BCDL: 0 PSF TOTAL LOAD:42 PSF TOTAL LOAD: 0 PSF DUR. FACTOR:1.25 DUR. FACTOR:1.00 DESIGN CRITERIA: FBC/ASCE 7-2002/TPI 1-02 WIND SPEED: 140 M.P.H. BUILDING EXPOSURE: B CATEGORY: RES 11 TYPE: MWFRS REVISIONS: 1. 2. 3. 4. APPROVAL IS NEEDED (4) WEEKS PRIOR TO DELIVERY DATE YOUR SIGNATURE WILL ACKNOWLEDGE (1) AUTHORIZATION TO BEGIN FABRICATION (2) VERIFICATION OF DIMENSIONS PITCHES, HEEL HEIGHTS, OVERHANGS, ETC. (3) TRUSSES WILL BE BUILT IN STRICT ACCORDANCE WITH THIS LAYOUT! ❑ APPROVED -NO CHANGES []APPROVED AS NOTED ❑ REVISE AND RESUBMIT SIGNED - DATE DELIVERY DATE TRUSS CORP. 2801 INDUSTRIAL 33RD FT. PIERCE, FL. 34946 PH. (772) 466 - 3388 FAX (772) 466 - 9329 TOLL FREE (800) 326 - 3388 saesr�rrauss cane SPANNING THE DISTANCE - WITH PEAK PERFORMANCE # JOB # 61225 OB-DICK PAWLUS JOB NAME STORAGE LOT/BLK/SUBDIV 2023 ST LUCIEBLVD LUCIE DATE 12/14/06 DRAWN BY DWH