HomeMy WebLinkAboutEngineering & TestingI ENGINEERING & TESTING, INC. Phone: (866) 781-6889 •Fax: (866) 78�-8550 www.floridaenginceringandtesting.com 250 S.W.13`h Avenue Pompano Beach, FL 33069 DATE: 8/02/17 JOB ORDER #: 17-2548 CLIENT: All Area Roofing ADDRESS: 3921 S. US Highway 1 Fort Pierce, Florida 34982 PROJECT: Treasure Coast Homeless Flat Wood Non -Insulated Roof Deck ADDRESS: 5414 Winter Garden Parkway Fort Pierce, Florida FBC 2014/ASCE 7-10 DESIGN PRESSURE CALCULATIONS Proiect Information: Height = 10' Exposure: C Basic/Ultimate Wind Speed: V,lt=170 mph Length = 48' Category: H Nominal Wind Speed: Vnd=V,at*v0•6 Width = 12' Slope: < 7° (asd = allowable strength design) Parapet Wall: N/A Residential KZ = 0.85, Kzt =1.0, Kd = 0.85 Design Calculations: Velocity Pressure: q = 0.00256*KZKztKdV2 Velocity Pressure (,,It): q=0.00256(0.85)(1.0)(0.85)(170)2] = 53.45 psf. Velocity Pressure (.d): q=0.00256(0.85)(1.0)(0.85)(170*y6.6)2] = 32.07 psf Width of Pressure Coefficient: 0.1(12') = 1.2' 0.4(10') = 4.0' } use: 3'0" Effective Wind Area: <10 2 For parapet height three feet (3') or larger, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: 1) GCP1 = -1.0 2) • GCP2 = -1.8 3) GCP3 = -2.8 Internal Pressure Coefficient: 1) GCPq = 0.18 - `-- - - -- v`�Q w � ��?� � QualityA��.11ssrcrance I / V �• lQ Page 2, 8/02/17, Job Order #1 ;48 All Area Roofing - Treasure Coast Homeless Flat Wood Non Insulated Roof Deck 5414 Winter Garden Parkway; Fort Pierce, Florida: Design Pressures Based on Vasd: FLO A 1) Field P1 = 32.07*[(-1.0) — (0.18)] = -37.8 psf 2) Perimeter P2 = 32.07*[(-1.8) — (0.18)] = -63.5 psf 3) Corners P3 = 32.07*[(-2.8) — (0.18)] = -95.6 psf Attachment Requirements Per RAS-117: Based on the requirements of N.O.A. #14-0529.02, pg 23 of 42, System Type E(3), with a maximum design pressure of-52.5psf; the following are our recommended fastening patterns to attach the proposed base sheet to the wood (non -insulated) 19/32" or greater plywood or wood plank deck utilizing approved 11 ga. annular ring shank nails and approved tin caps: Field: 8" o.c. @ 4" laps and 3 staggered rows 8" o.c. Perimeter: 6" o.c. @ 4" laps and 3 staggered rows 6" o.c. Corners: 6" o.c. @ 4" laps and 5 staggered rows 6" o.c. Notes: Comers and perimeter area dimension shall not be less than a = 3'0" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2014 Edition. Wind load calculations based on ASCE 7-10, FBC 2014 and information provided by client. Client is responsible for verifying existing conditions as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sincerely, F7- Mark A. Mesiano, P.E. Florida Engineering & Testing, Inc. Florida Reg. No. 48202 Certificate of Authorization No. 6923