Loading...
HomeMy WebLinkAboutProduct Approval1 Florida Building Code Online Page 1 of 3 RECEIVED AUG 04 2017 ,,=lolida Depamientaf BCIS Home I Log In ? User Registration i Hot Topics ; Submit Surcharge i Stats & Facts { Publications i FBC Staff { BCIS Site Map I Links I Search j BusinesE"' Professal Product Approval USER: Public User a FIB. SPY Regulation Product Approval Menu > Product or Aoolication Search > Aoolication List > Application Detail FL # FL13509-R4 Application Type Revision Code Version 2014 Application Status Approved Comments Archived D Product Manufacturer NATURAL LIGHT ENERGY SYSTEMS Address/Phone/Email 10821 N. 23rd Ave. PHOENIX, AZ 85029 (602) 485-5984 kelly@nitubular.com Authorized Signature Kelly Joya kelly@nitubular.com Technical Representative Gregg Vincent Address/Phone/Email 10821 N. 23rd Ave. Phoenix, AZ 85029 (602) 485-5984 gvincent@nitubular.com Quality Assurance Representative Mark Orszulak Address/Phone/Email 10821 N. 23rd. Ave. Phoenix, AZ 85029 (602)485-5984 Mark@nitubular.com Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Allen Douglas Gezelman the Evaluation Report Florida License PE-59180 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By James Tippens, PE E1 Validation Checklist - Hardcopy Received Certificate of Independence FL13509 R4 COI NLT PV ATTIC FAN PCA FL 13509 COI 131.odf Referenced Standard and Year (of Standard) Standard ASTM E330 TAS 100A TAS 202 Year 2002 1995 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL13509 R4 Eauiv PCA FL13509 STANDARD OUIVALENCY 2014 FBC DS.odf littps://www.floridabuilding.org/pr/pr- app_dtl.aspx?param--wGEVXQwtDqiiynOPErOHee... 3/23 /2016 Florida Building Code Online Page 2 of 3 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 09/28/2015 11/12/2015 11/13/2015 12/15/2015 FL # Model, Number or Name Description 13509.1 NATURAL LIGHT ENERGY SYSTEMS NATURAL LIGHT ENERGY SYSTEMS SOLAR ATTIC FANS GABLE MOUNTED SOLAR ATTIC POWERED BY PV PANELS FAN Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +86.5/-175 Other: FL13509 R4 II oable attic fan install Ddf Verified By: LICENSED PE PE59180 Created by Independent Third Party: No Evaluation Reports FL13509 R4 AE 1LDR-PVAF-VENTI(009)(2)pdf FL13509 R4 AE NLT PV ATTIC FAN PCA FL 13509 ENGR EVAL. REPORT (9).Ddf Created by Independent Third Party: No 13509.2 NATURAL LIGHT ENERGY SYSTEMS NATURAL LIGHT ENERGY SYSTEMS SOLAR ATTIC FANS ROOF MOUNTED SOLAR ATTIC POWERED BY PHOTO VOLTAIC PANELS FANS Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +86.5/-175 Other: LIMITED TO WOOD ROOF DECKS FL13509 R4 II SAF install Florida Ddf Verified By: PROFESSIONAL ENGINEER FL 59180 Created by Independent Third Party: No Evaluation Reports FL13509 R4 AE 1LDR-PVAF-VENTI (009) (2)Ddf FL13509 R4 AE NLT PV ATTIC FAN PCA FL 13509 ENGR EVAL. REPORT (9).Ddf EL13509 R4 AE SAF E330-A8071 01-301-44-RO Ddf FL13509 R4 AE TAS202 -A8071 02-301-18-R0(2)ndf Created by Independent Third Party: No 13509.3 TURAL LIGHT ENERGY SYSTEMS NATURAL LIGHT ENERGY SYSTEMS SOLAR ATTIC FANS OF MOUNTED SOLAR ATTIC TFANS POWERED BY PHOTO VOLTAIC PANELS Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +86.5/-175 Other: FL13509 R4 II SAF install Florida pdf Verified By: Allen Gezelman PE 59180 Created by Independent Third Party: No Evaluation Reports FL13509 R4 AE 1LDR-PVAF-VENTI (009) (2)Ddf FL13509 R4 AE NLT PV ATTIC FAN PCA FL 13509 FNGR EVAL. REPORT (9).odf Created by Independent Third Party: No Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32Il99 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. coovriaht 2007-2013 State of Florida.:; Privacy Statement :: Accessibility Statemen :: Refund tat m nt Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 4S5, F.S., please click here . Product Approval Accepts: St:cu.lt :511:. RIGS" https://www. floridabuilding. org/pr/,nr_app_dtl. aspx?param=wGEVXQ WtDquynOPErOHee... 3/23/2016 EVALUATION REPORT BY FLORIDA PROFESSIONAL ENGINEER: PAGE OF2PAGES FLORIDA PRODUCT CONTROL APPROVAL (PCA) FL 13509 FLORIDA RULES CHAPTER 61G20-3.005(d) EVALUATOR: ALLEN GEZELMAN, PE 59180 16502 HANNA RD. LUTZ, FL 33549 PHONE 813 909 1956 EMAIL allen@gezelmanpe.com PRODUCT CATEGORY: ROOFING PRODUCT SUB -CATEGORY: ROOFING ACCESSORIES THAT ARE AN INTEGRAL PART OF THE ROOFING SYSTEM COMPLIANCE METHOD: FLORIDA RULES CHAPTER 61G20-3.005 (d) EVALUATION REPORT BY FLORIDA PROFESSIONAL ENGINEER MANUFACTURED BY: NATURAL LIGHT ENERGY SYSTEMS 10821 NORTH 23RD AVENUE PHOENIX, ARIZONA 85029 PRODUCT DESCRIPTION: THIS SOLAR POWERED ATTIC FAN HAS 0.80-INCH THICK, 1100 SERIES ALUMINUM, EXTERNAL COMPONENTS (SELF -FLASHING MOUNTING BASE AND HOOD) TO WHICH ARE MOUNTED BRACKETS SUPPORTING A UL-LISTED PHOTO -VOLTAIC (PV) MODULE AND A DC FAN MOTOR. A STAINLESS STEEL SCREEN PREVENTS ENTRY OF PESTS. SEE DRAWINGS CONTAINED WITHIN THIRD PARTY TESTING BELOW. THIRD PARTY TESTING: PRI (TAS 100(A)-95) REPORT NO: NLES-001-02-02, DATED 12/21/09 ARCHITECTURAL TESTING (ASTM E 330-02) TEST REPORT NO: A8071.01-301-44, DATED 03/21/11 ARCHITECTURAL TESTING (TAS 202-94) TEST REPORTA8071,02-301-18, DATED 08/24/13. EVALUATION: USING A 200% SAFETY FACTOR, ABOVE REFERENCED THIRD PARTY TESTING ESTABLISHED DESIGN PRESSURE RATINGS OF PRODUCT AS+86.5_PSF (DOWNWARD) AND-175_PSF (UPLIFT). REFERENCED THIRD PARTY TESTING PROVED THE RESISTANCE OF FAN SELF -FLASHING. WATER -PROOF BASF, AND. HOOD TO WIND —DRIVEN RAIN ENTRY. INSTALLATION: THIS PRODUCT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS WHICH SHALL BE SUPPLEMENTED BY USE OF CURRENT FLORIDA BUILDING CODE AND NATIONAL ROOFING CONTRACTORS ASSOCIATION ROOFING & WATER -PROOFING MANUAL FOR DETAILS NOT SPECIFICALLY DESCRIBED IN MANUFACTURERS'S INSTALLATION INSTRUCTIONS. EVALUATION REPORT BY FLORIDA PROFESSIONAL ENGINEER: ..1/1 PAGE 20F2PAGES LIMITATIONS: THIS PRODUCT APPROVAL SHALL BE LIMITED TO WOOD ROOFS. THIS PRODUCT SHALL NOT BE INSTALLED IN ROOF PRESSURE ZONE 3 AS DESIGNATED BY ASCE 7 „ (AMERICAN SOCIETY OF CIVIL ENGINEERS —MINIMUM DESIGN LOADS FOR BUILDINGS), Allen Gezelman 6l 16502 Hanna Rd APR 3 0 2015 Lutz, FL 33549��� 813 909 1956 bolsonl@tampabay.rr.com �, ; �" c;.d a Z�C' F J�` ; �.�•z: '+ram ' ; �� -.. f!ll11 f'"' U PORTAM IT: Before Onstagoorn g Please take the time to read through the ENTIRE instructions prior to starting any work. Pveca. utgons 1. Ensure normal safety precautions are taken when using tools and walking on roofs. 2. Do not cut any structural members in the house. 3. Measure twice and cut once. Took Required • Reciprocating Saw Caulking Gun o Measuring Tape • Marking Pen Screw Gun o Razor Knife • String o Ladders Co �uponents Mote: Exploded view for illustrative purposes. Unit comes pre -assembled. "u. (2) #8 Phillips Head Screws/Clip Assembly 2. Custom Solar Panel 3. Wire Lead 4. Adjustable Solar Panel Bracket S. Aluminum Shroud 6. Custom DC Motor 7. Motor Isolation Bracket 8. Air Drive Precision Pitch Blade 9. 4" x 48" Stainless Steel Wire Mesh T®. Rugged 14 Gauge Shroud Support Bracket TT. (6) #6 x 1 1 /2" Stainless Steel Phillips Head Screws 12. Aluminum Flashing 1 2 is 7 Onsta fla tilo n Polinters When determining location of the unit, try to place the solar attic fan on the south side of the roof, also consider potential problems such as objects shading the unit during certain times of the day. The unit should also be centered on the roof and the center of the unit should be about 2 feet down from the roof ridge. Choose location for solar vent unit, south exposure is best. if a southern ex- posure is not feasible for your installation, the fan can be installed on any other exposure and the solar panel adjusted to capture maximum sunlight. Step 2 Hammer a nail at the center of the location chosen between rafters for the solar attic fan unit. The center of the unit should be about 2 feet down from the ridge. Attach a string to the nail. Measure 9.5" of string and attach a marking pen to the string, see diagram. Scribe a 19" circle onto the roof shingles or use the template created earlier. Iep With a reciprocating saw, cut the diameter of the hole. IMPORTANT: The solar attic fan must be installed between the roof rafters or over a roof rafter. DO NOT CUT THROUGH ANY FRAMING MEMBER. trey 4 Roof rafters are generally 16" or 24" on center. On 16" on center construction, the installer can either cut a 14" hole between the rafters or cut a 19" hole with the roof rafter running through the cut hole - do not cut the rafter (see diagram). On 24" on center construction, center the fan between the rafters. NEVER CUT THROUGH ANY ROOF RAFTERS. LEAVE ALL FRAMING MEMBERS IN PLACE. Only remove roof sheathing. %ep 3 With a razor knife, cut a four inch slit through the shingles and tar paper at the three and nine o'clock position of the flashing. This allows for the foot print of the flashing to be inserted under the shingles. NOTE: If a 14" hole was cut instead of a 19" hole in Step 3, additional shingles may also need to be removed on the high side towards the ridge to allow the flashing to slide over the hole (see inset Illustration). 01 16" ON CENTER INS TALL a Ma a ,tep 6 Insert the reciprocating saw blade sideways at the three o'clock position and commence cutting the roofing nails up and around to the nine o'clock position. This process removes the nails that will prevent the flashing foot print from sliding up underneath the shingles. Step 7 Caulk underside of flashing with the provided caulking material. Two concentric rings of caulking material is sufficient. NOTE: Installation on tile roofs will require the use of a skirt. step a Taking care not to smear caulk on the exposed shingles, slide flashing under tar paper and shingles and force flashing up until the shingles come in contact with the raised portion of the flashing. The bottom side of the flashing will be on top of the shingles. Secure flashing with four Phillips head screws at the 3:00, 6:00, 9:00 and 12:00 positions. The 3:00 and 9:00 positions screws should go under the shingles. The 6:00 and 12:00 position screws should go on top of the shingles. ;tip c At the 6:00 and 12:00 positions, caulk over the screw head, since it will be exposed to the weather. Use remaining caulk to seal the areas where the 4" slits were made and around the area where the shingles meet with the raised area of the flashing. Step 10 Loosen, but do not remove, the screw on the clip/screw assembly located on each side of the solar panel bracket. Adjust the solar panel to the position it will collect the most sunlight throughout the day. Tighten screws at the desired position. �� Wiffin- En 0 0 //•J/J Natural Lighter- rf This Natural Light Solar Attic Fan has a 25 year warranty . on the housing, the sole panel ajad the motor. IMPORTANT. PLEASE COMPLETE AND MAIL THE CARD BELOW AS SOON AS YOUR SOLAR ATTIC FAN IS INSTALLED. This card will serve as proof of your purchase, should you misplace your original invoice. The manufacturer warrants this product to be free from defects in material and manufacturer's workmanship for a period of 25 years on the motor, the solar panel and the housing, from the date of installation. This warranty is subject to proper installation of the unit in accordance with the manufacturer's written installation instructions. The manufacturer will not be liable for any special, incidental or consequential damages in any way related to, or arising out of, defects in, or damage to, the solar attic fan. This warranty gives you specific legal rights, and you may have other rights which vary from state to state concerning exclusion or limitation of incidental or consequential damages. Please fill out the form below and mail it to: Natural Light Energy Systems o 10821 North 23rd Avenue o Phoenix, AZ 85029 •�.;�Or., F` Natural Light Solar Attic Fan Installer: Date of Purchase: Customer Name: Address: City: State: Zip: Customer Survey Are you satisfied with the performance? Y N What made you choose our product? Were you satisfied with the installation job? Comments: