A SOLAR PV SYSTEM IMPROVEMENT FOR0
:
DAVIS RESIDENCE
o �
SOLAR IMPROVEMENT CONSTRUCTION DOCUMENTS PROJECf:
FOR THE EXISTING RESIDENTIAL GRID TIED ELECTRICAL
9
9
8
W
W
SYSTEM �N
sv LucIE c®uNnr o N
BUILDING DIVISION W -<
D
REVIEW@
~ 2 C'4
FOR O p ,,
REVIEWED B " O
DATE Q t5 coo
7 Lu N U
PLANS AND PERMIT '� `>� +Ts
MUST BE KEPT ON JOB OR N Z Q
NO INSPECTION WILL BE MADE s it a
Cie V V
Q w w Lu
ppa
VICINITY MAP INDEX SHEET DRAWING NAME O ex W I.— w_
N C- a- u—
al� s. CV COVERSHEET gW
SLR1 SOLAR SYSTEM EQUIPMENT LOCATION PLAN DATE 7/21/2017 g
1 F o�
a�� �� DRAWN BY: AT
�
y PVR-SS ROOF ATTACHMENT DETAIL - SOLAR ELECTRIC
CHKD BY: AT
SLR2 ELECTRICAL 3-LINE DIAGRAM WITH CALCULATIONS jREC.o.#
--------APPENDIX -------- AS NOTED
FSEC CERTIFICATION — SOLAR PV
DRAWING#
�P 4 HELIENE 300W MODULE DATA SHEET V g
—12
APSYSTEMS YC500 MICROINVERTER DATA SHEET
SHEET I OF 4_
41, ,..
ry
rb ms
RESIDENTIAL ROOF LAYOUT - WIND ZONES - PV MODULE LAYOUT AND EQUIPMENT LOCATION PLAN
SCALE: N.T.S.
)FTOP JUNCTION BOX
ROXIMATE LOCATION
WIRE TRANSITION.
SHEET SLR2
MATERIALS REQUIRED:
(17) HELIENE 60M 300W MODULES W/ (9) APSYSTEMS YC-500
(9) IRONRIDGE MICROINVERTER MOUNTING KITS (NOTE: EACH
KIT COMES WITH 2 BOLTS)
(2) 17' XR100 RAIL
(6) 14' XR100 RAIL
(4) XR-100 INTERNAL BONDED SPLICE KITS
(4) GROUNDING LUGS FOR ARRAY CONNECTIONS OF #6 BARE COPPER
(50) WIRE MANAGEMENT CLIPS
(30) IRONRIDGE L-FOOT WITH LAG SCREW
(8) IRONRIDGE END SLEEVES
(8) IRONRIDGE END CAPS FOR RAILS
(38) IRONRIDGE GROUNDING UFO CLAMPS
(2) APSYSTEMS TRUNK CABLE END CAP
(9) APSYSTEMS TRUNK CABLE
APSYSTEMS T-CONN CAPS (AS NEEDED)
(1) NEMA 3R RATED ROOF MOUNTED JUNCTION BOXES
DISCLAIMER: MATERIALS REQUIRED LIST FOR CONCEPTUAL USE ONLY
THE INTENT IS TO AID CONTRACTOR FOR ORDERING REQUIRED MATERIALS
FOR THE PROJECT. CONTRACTOR RESPONSIBLE TO VERIFY PRIOR TO
SOLAR EQUIPMENT ORDERING.
ROOF LAYOUT NOTE:
SOLAR PANEL LAYOUT IS CONCEPTUAL, BUT AS PROVIDED, CONFORMS WITH THE REQUIREMENTS SET IN
SHEET PVR-SS FOR SPECIFIED ADDRESS. CONTRACTOR MAY ADJUST PANEL LOCATION, BUT SHALL
CONFORM TO THE REQUIREMENTS ON SHEET PVR-SS. SOLID AREAS ON CORNERS OF ROOF ARE WIND
ZONE 3 AREAS.
m
Y
a
0
W
PROJECT:
I—
w
w w
V F--
Z c"31
o
LU W
W
� ckt N
O �
� o N CN
co
o"
uj
w ch
Z < LL
to I— u?
Cie V V u
W W
J W
0 0Cie 0 -
to a d u-
DATE 1 7/21/2017
DRAWN BY: I JAT
CHKD BY: JAT
REC. NO. #
SCALE I AS NOTED
DRAWING #
SLR1
SHEET 2 OF 4
PHOTOVOLTAIC MODULE GENERAL NOTES:
1. APPLICABLE CODE: 2014 FLORIDA RESIDENTIAL CODE (5TH EDITION) & ASCE 7-10 MINIMUM DESIGN
LOADS FOR BUILDING AND OTHER STRUCTURES.
2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2014 FLORIDA BUILDING CODE (5TH
EDITION) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHER YELLOW PINE (SYP)
RESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL.
3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIENTIAL ROOFS,
CONSIDERING FROM A 7- TO A MAXIMUM 27° (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN
SCHEDULE. EXISTING RESIDENTIAL ROOF SHALL NOT EXCEED 30'-0" MEAN ROOF HEIGHT.
4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITY
OF THE CONTRACTOR TO PILOT FILL ALL HOLES.
5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO MANUFACTURER MANUAL
FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND SOLAR SPECS.
6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS OTHERWISE NOTED.
7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED.
8. ALL 39" X 65" PV MODULES MAY BE INSTALLED PER THIS STRUCTURAL CONNECTION DRAWING.
9. ALL SOLAR RAILING AND MODULES SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS.
10. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2014
FLORIDA RESIDENTIAL CODE (5TH EDITION) OR LOCAL GOVERNING CODE.
ULTIMATE
WIND ZONE 1 MAX
WIND ZONE 2 MAX
WIND ZONE 3 MAX
EMBED.
WIND SPEED
SPAN, MAX
SPAN, MAX
SPAN, MAX
DEPTH
Vw(MPH)
CANTILEVER
CANTILEVER
CANTILEVER
REQ.
160
4'-0" O.C., l'-7" O.C.
4'-0" O.C. , V-7" O.C.
2'-0" O.C., 9" O.C.
3"
- SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND PRESSURES WITH
EXPOSURE "B", RISK CATEGORY II , ENCLOSED BUILDING AND h < 60%0" PER ASCE 7-10
"MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" AND 2014 F.B.C.
* LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDES ANY ROOF DECKING THICKNESS.
a DIMENSION DEFINED PER ASCE 7-10 SHALL BE 4 FT REGARDLESS AS PER 2014 FLORIDA
RESIDENTIAL CODE 5TH EDITION
2 2
I ,•
I 1
GABLE END BUILDING HIP END BUILDING ROOF �' ,� i
ji
ROOF WIND AREA ZONES WIND AREA ZONES
I i I
- - - - - - - - - - - 2--2-----I ---
rl ------ I ®it®
---------------
al" i 0
I�
1-
L -----
1- --� -r
low I I
I I
� � I
TYPICAL PHOTOVOLTAIC -ARRAY PITCHED ROOF
LAYOUT - WIND ZONES - SCHEDULE - PLAN
SCALE: NONE
39" X 65" PHOTOVOLTAIC ALUM. SOLAR RAIL TYP 2 PLCS
MODULE TYP. ARRAY.
TRS 3\ C TRS . 1Z TRS
TRS . T C TRS
L L'MAX CANT. SEE SCH. ASPHALT SHINGLES ALUM L-FOOT - DIA ST STL LAG BOLT TYP. SEE SCH
/METAL 5V ROOF TYP. FOR MAX SPAN REQ.
TYPICAL PHOTOVOLTAIC MODULE ARRAY PLAN
SCALE: 16'=1'-0"
S.Y.P. 2X4 LOCATE BETWEEN
TRUSSES AND NAIL WITH
2-16D NAIL PATTERN AT EACH
END TO WOOD TRUSS
2X PT S.Y.P. WOOD
UNISTRUT CONT. AL
STEEL ALL-THRD
OD W/ NUT -
WASHERS - LOCTITE
ALL NUTS TYP.
ALL CONNECTIONS
OPTIONAL SPANNER CONNECTION DETAILS
SCALE: 1 2'=1'-0"
12" ALUMINUM INTERNAL
SPLICE BAR (USE WHEN
__=T===== ___________________________________,_______-____ SPLICE AT MID -SPAN W/
------
- -_-�_- o - -_ (4) #12-14X8' ST STL SELF
--------=-------------- - -- -=- ' -= TAPPING SCREWS TYP
IRONRIDGE XR1000 OR XR100 #12.14X8" ST STL SELF TAPPING
ALUM. SOLAR RAIL TYP SCREW TYP 4 PLCS PER BEAM SPLICE
TYPICAL SOLAR RAIL BEAM SPLICE DETAIL
SCALE: 1 2'=1'-0"
TYP. 2 PLCS. PER SIDE OF MODULE AND BE CONNECTED < 25% OF MODULE LENGTH
USE ANTI -SEIZE AND TIGHTEN TO TORQUE
PER MANUF. INSTRUCTIONS
REFER TO SCHEDULE FOR
REQUIRED EMBEDMENT DEPTH
LABELED "X" IN THIS DETAIL. b t'LQ'
ALUMINUM L-FOOT TYP
EVERY ROOF PENETRATION 9
3�
e - 16 HEX CAP ST STL
BOLT AND ST STL 'O
SERRATED FLANGE -NUT
TYP. t
END -CLAMP W/ 4' -
PHOTOVOLTAIC
20 HEX CAP ST STL
MODULE TYP.
- ' BOLT AND ST STL
ASPHALT SERRATED
SHINGLES / FLANGE -NUT TYP.
IRONRIDGE XR1000
METAL 5V END -CLAMP SIZE
OR XR100 ALUM.
WOOD ROOFING TYP. VARIES.
SOLAR RAIL TYP.
SHEATHING 16" ST STL LAG BOLT. SEE
WOOD ROOF SCH FOR EMBED DEPTH
TRUSS TYP. REQ. TYP EACH L-FOOT
TYPICAL PV SOLAR RAIL END CONNECTION DETAILt-_31
SCALE: 1 z"=1'-0"
REFER TO SCHEDULE FOR REQUIRED
EMBEDMENT DEPTH LABELED "X" IN
THIS DETAIL.
ALUMINUM L-FOOT
TYP EVERY ROOF
PENETRATION
8" - 16 HEX CAP ST STL BOL
AND ST STL SERRATED
FLANGE NUT TYP. I%
m
Y
a
0
w
PROJECT.
DATE: 1 7-21.2017
DRAWN BY:
JAT
N
�
�A
CHKD BY:
JAT
�s
RECORD #: 29127
I
SCALE: AS NOTED
\—CENTER-CLAMP WITH
4' - 20 HEX CAP ST
PHOTOVOLTAIC STL BOLT AND (1) ST
STL SERRATED
MODULE TYP. �\
ASPHALT FLANGE NUT TYP. \\�
IRONRIDGE XR1000
OR XR100 ALUM. SHINGLES FRONT SIDE BEAM$ t
SOLAR RAIL TYP. METAL 5V LOCATION. SEE T�'DE�fL�
WOOD ROOFING 16" ST STL LAG BOLT. SEE�CH ;
WOOD ROOF TYP' FOR EMBED. DEPTH REQ.P* ;
SHEATHING TRUSS TYP. EACH L-FOOT 1 Z
TYPICAL PV SOLAR RAIL MID CONNECTION DETAIL
iiF
SCALE: 1 2'=1'-0"
DRAWING #
G
��s
N 7
-MN—
W
0///// 11111111\\�
JUL 21 2017
l
POWER TABLE:
DC -SIDE
A
B
1
500 W
240 VAC
2.08 A
60 HZ
# PV MODULE
1
MANUF
HELIENE
MODEL
60M
POWER
300 Wp-dc
VOC
39.83 VDC
ISC
9.59 A
VMP
33.14 VDC
IMP
9.13 AMP
** STC: CELL TEMPERATURE @ 25" C, SPECTRU
SYSTEM A
(9) MODULES/ (5) INVERTERS IN
BRANCH CIRCUIT
TERMINATOR CAP
INSTALLED
ON END OF TC-ER
CABLE SYSTEM
CONTINUOUS #6 AWG CU
CONDUCTOR BONDING SOLAR
RAIL, MODULES, AND
MICROINVERTERS W/ WEEB
LUGS OR MODULES AND
MICROINVERTERS MAY
BE BONDED TO RAIL WITH
WEEB WASHERS, INTEGRATED
GROUNDING MID CLAMP OR
EQUIVALENT TO SIMPLIFY
INSTALLATION.
SYSTEM A SYSTEM B
1ST BRNCH C 2ND BRI
5 4
2500 W
2000 W
240 VAC
240 VAC
10.4 A
8.32 A
60 HZ
60 HZ
1.5, IRRADIANCE @ 1000
A T
TC-ER #12 AWG CU 90
RATED INSULATED CABLE
AC -SIDE
INVERTER
APSYSTEMS YC500
RATED POWER
VOLTAGE
CURRENT
FREQUENCY
TC-ER
CABLE SYSTEM
AP YC500A MICROINVERTER TYP.
#6 AWG SOLID CU GROUND TYP.
SYSTEM B
(8) MODULES/ (4) INVERTERS
IN BRANCH CIRCUIT
SIMILAR GROUNDING STRATEGY AS BRANCH CIRCUIT A
NEC 2011 LABELING REQUIREMENTS
PHOTOVOLTAIC AC DISCONNECT
MAXIMUM AC OPERATING CURRENT: 18.72 A
MAXIMUM AC OPERATING VOLTAGE: 240 V
(PER NEC 690.54 - PROVIDE AT EXTERNAL AC
DISCONNECT OR MAIN SERVICE PANEL IF
APPLICABLE)
GENERAL PHOTOVOLTAIC 3-LINE DIAGRAM SPECIFIC FLAG NOTES:
OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES
PRIOR TO THE COMMENCEMENT OF WORK
LABEL DEVICE PER NEC 690.14(C)(2), AND SECURE PER NEC 690.7(D).
EQUIPMENT SHALL BE INSTALLED PER THE 2011 NATIONAL ELECTRICAL
22 CODE (NEC), ALL APPLICABLE OR GOVERNING CODES, MANUFACTURER LABEL BREAKER PER NEC 690.54, 705.12(D) AND 705.10.
REQUIREMENTS OF AND PER THE GOVERNING UTILITY COMPANY.
LISTING AGENT NAME AND NUMBER SHALL BE INDICATED PER NEC PV BACKFEED CURRENT PLUS MAIN BREAKER RATING MUST BE LESS THAN
OR EQUAL TO 120% OF MAIN SERVICE BUS RATING AND BREAKERS MUST
BE MOUNTED AT OPPOSITE END OF MAIN BREAKER PER NEC 705.12(D).
CONDUCTOR WIRE SIZES SHOWN BASED SOLELY ON AMPACITY IF PV BACKFEED CURRENT PLUS MAIN BREAKER RATING EXCEEDS 120% OF
REQUIREMENTS. TO PREVENT AN INCREASE IN AC VOLTAGE LEVEL AND 8 MAIN SERVICE BUS RATING, CONTRACTOR SHALL LOCATE ADEQUATELY
AVOID ANY NUISANCE FAULTS, IT IS RECOMMENDED TO SIZE
CONDUCTOR FOR A TOTAL VOLTAGE DROP OF 2% OR LESS PER INV. SIZED DISCONNECT BETWEEN SUB/SERVICE PANEL AND SUPPLY SIDE
MANUFACTURER. CONNECTION AND COMPLY WITH NEC 705.12(A)
TC-ER #11 AWG CU
90 C RATED INSULATED CABLE Ll
#6 AWG SOLID CU GROUND TYP.
G
BRANCH CIRCUIT B TO BE CONNECTED THE SAME
AS BRANCH CIRCUIT A WITH SAME INVERTER
AND MODULE TYPE ALONG CABLE SYSTEM
TC-ER 90 C RATED INSULATED CABLE
#6 AWG SOLID CU GROUND TYP.
C INVERTER OUTPUT CIRCUIT CABLE
OUTDOOR / INDOOR CONDITIONS
(3) # 10 AWG CU, INSULATION: THHN/THWN-2
(1) # 10 AWG CU, INSULATION: THHN/THWN-2
GROUND CONDUCTOR
CONDUIT SIZE: 2" MINIMUM
ATTIC SPACE / WALL INTERIOR RUN ONLY
WIRING OPTION
(3) # 10 AWG W/ (1) #10 GROUND
NM ROMEX CABLE, OF CABLE OR
EQUIVALENT
A
A
GI I
JUNCTION BOX
NOTE: ALL CONDUCTORS THIS SHEET SHALL BE COPPER UNLESS OTHERWISE NOTED. NEMA 3R
ENCLOSURE
MAIN PV SYSTEM
DISCONNECT
PER NEC 690.14(2) - PROVIDE AT MAIN
SERVICE PANEL
ELECTRIC SHOCK HAZARD. DO NOT TOUCH
TERMINALS. TERMINALS ON BOTH THE LINE
AND LOAD SIDES MAY BE ENERGIZED IN THE
OPEN POSITION
LABEL PER NEC 690.17 - PROVIDE AT MAIN SERVICE PANEL
WARNING
INVERTER OUTPUT CONNECTION - DO NOT
RELOCATE THIS OVERCURRENT DEVICE
LABEL PER NEC 705-12(D)(7) - PROVIDE AT MAIN SERVICE PANEL
EXISTING 150
AMP MAIN
SERVICE PANEL
(VERIFY IN FIELD)
TO EXISTING
GROUNDING
ELECTRODE
WARNING
DUAL POWER SOURCE
SECOND SOURCE IS PV SYSTEM
PHOTOVOLTAIC SYSTEM
CIRCUIT IS BACKFED
LABEL PER NEC 705.12(D)(4) - PROVIDE AT MAIN
SERVICE PANEL
m
Y
1'
a
0
PROJECT:
w
w
L. Lu
U I--
Z to
0 co
to ww
lL c-' CV
to
Lu L Q N tp
ce tT
� Lo M
w _
> Z Q u
Q V Lu
V
L.0 w w
0 00� to d a L-
DATE 7/21/2017
DRAWN BY: JAT
CHKD BY: JAT
REC. NO. #
SCALE AS NOTED
DRAWING #
SLR2
SHEET 4 OF 4
TE
XIMUM OF 7 INVERTERS PER
,NCH CIRCUIT PER
NUFACTURER
OMMENDATIONS.
1
r