Loading...
HomeMy WebLinkAboutSolar PV System0 ffJ"ems O'oq 5083 A SOLAR PV SYSTEM IMPROVEMENT FOR0 : DAVIS RESIDENCE o � SOLAR IMPROVEMENT CONSTRUCTION DOCUMENTS PROJECf: FOR THE EXISTING RESIDENTIAL GRID TIED ELECTRICAL 9 9 8 W W SYSTEM �N sv LucIE c®uNnr o N BUILDING DIVISION W -< D REVIEW@ ~ 2 C'4 FOR O p ,, REVIEWED B " O DATE Q t5 coo 7 Lu N U PLANS AND PERMIT '� `>� +Ts MUST BE KEPT ON JOB OR N Z Q NO INSPECTION WILL BE MADE s it a Cie V V Q w w Lu ppa VICINITY MAP INDEX SHEET DRAWING NAME O ex W I.— w_ N C- a- u— al� s. CV COVERSHEET gW SLR1 SOLAR SYSTEM EQUIPMENT LOCATION PLAN DATE 7/21/2017 g 1 F o� a�� �� DRAWN BY: AT � y PVR-SS ROOF ATTACHMENT DETAIL - SOLAR ELECTRIC CHKD BY: AT SLR2 ELECTRICAL 3-LINE DIAGRAM WITH CALCULATIONS jREC.o.# --------APPENDIX -------- AS NOTED FSEC CERTIFICATION — SOLAR PV DRAWING# �P 4 HELIENE 300W MODULE DATA SHEET V g —12 APSYSTEMS YC500 MICROINVERTER DATA SHEET SHEET I OF 4_ 41, ,.. ry rb ms RESIDENTIAL ROOF LAYOUT - WIND ZONES - PV MODULE LAYOUT AND EQUIPMENT LOCATION PLAN SCALE: N.T.S. )FTOP JUNCTION BOX ROXIMATE LOCATION WIRE TRANSITION. SHEET SLR2 MATERIALS REQUIRED: (17) HELIENE 60M 300W MODULES W/ (9) APSYSTEMS YC-500 (9) IRONRIDGE MICROINVERTER MOUNTING KITS (NOTE: EACH KIT COMES WITH 2 BOLTS) (2) 17' XR100 RAIL (6) 14' XR100 RAIL (4) XR-100 INTERNAL BONDED SPLICE KITS (4) GROUNDING LUGS FOR ARRAY CONNECTIONS OF #6 BARE COPPER (50) WIRE MANAGEMENT CLIPS (30) IRONRIDGE L-FOOT WITH LAG SCREW (8) IRONRIDGE END SLEEVES (8) IRONRIDGE END CAPS FOR RAILS (38) IRONRIDGE GROUNDING UFO CLAMPS (2) APSYSTEMS TRUNK CABLE END CAP (9) APSYSTEMS TRUNK CABLE APSYSTEMS T-CONN CAPS (AS NEEDED) (1) NEMA 3R RATED ROOF MOUNTED JUNCTION BOXES DISCLAIMER: MATERIALS REQUIRED LIST FOR CONCEPTUAL USE ONLY THE INTENT IS TO AID CONTRACTOR FOR ORDERING REQUIRED MATERIALS FOR THE PROJECT. CONTRACTOR RESPONSIBLE TO VERIFY PRIOR TO SOLAR EQUIPMENT ORDERING. ROOF LAYOUT NOTE: SOLAR PANEL LAYOUT IS CONCEPTUAL, BUT AS PROVIDED, CONFORMS WITH THE REQUIREMENTS SET IN SHEET PVR-SS FOR SPECIFIED ADDRESS. CONTRACTOR MAY ADJUST PANEL LOCATION, BUT SHALL CONFORM TO THE REQUIREMENTS ON SHEET PVR-SS. SOLID AREAS ON CORNERS OF ROOF ARE WIND ZONE 3 AREAS. m Y a 0 W PROJECT: I— w w w V F-- Z c"31 o LU W W � ckt N O � � o N CN co o" uj w ch Z < LL to I— u? Cie V V u W W J W 0 0Cie 0 - to a d u- DATE 1 7/21/2017 DRAWN BY: I JAT CHKD BY: JAT REC. NO. # SCALE I AS NOTED DRAWING # SLR1 SHEET 2 OF 4 PHOTOVOLTAIC MODULE GENERAL NOTES: 1. APPLICABLE CODE: 2014 FLORIDA RESIDENTIAL CODE (5TH EDITION) & ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES. 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2014 FLORIDA BUILDING CODE (5TH EDITION) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHER YELLOW PINE (SYP) RESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL. 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIENTIAL ROOFS, CONSIDERING FROM A 7- TO A MAXIMUM 27° (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. EXISTING RESIDENTIAL ROOF SHALL NOT EXCEED 30'-0" MEAN ROOF HEIGHT. 4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITY OF THE CONTRACTOR TO PILOT FILL ALL HOLES. 5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO MANUFACTURER MANUAL FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND SOLAR SPECS. 6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS OTHERWISE NOTED. 7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. 8. ALL 39" X 65" PV MODULES MAY BE INSTALLED PER THIS STRUCTURAL CONNECTION DRAWING. 9. ALL SOLAR RAILING AND MODULES SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS. 10. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2014 FLORIDA RESIDENTIAL CODE (5TH EDITION) OR LOCAL GOVERNING CODE. ULTIMATE WIND ZONE 1 MAX WIND ZONE 2 MAX WIND ZONE 3 MAX EMBED. WIND SPEED SPAN, MAX SPAN, MAX SPAN, MAX DEPTH Vw(MPH) CANTILEVER CANTILEVER CANTILEVER REQ. 160 4'-0" O.C., l'-7" O.C. 4'-0" O.C. , V-7" O.C. 2'-0" O.C., 9" O.C. 3" - SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND PRESSURES WITH EXPOSURE "B", RISK CATEGORY II , ENCLOSED BUILDING AND h < 60%0" PER ASCE 7-10 "MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" AND 2014 F.B.C. * LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDES ANY ROOF DECKING THICKNESS. a DIMENSION DEFINED PER ASCE 7-10 SHALL BE 4 FT REGARDLESS AS PER 2014 FLORIDA RESIDENTIAL CODE 5TH EDITION 2 2 I ,• I 1 GABLE END BUILDING HIP END BUILDING ROOF �' ,� i ji ROOF WIND AREA ZONES WIND AREA ZONES I i I - - - - - - - - - - - 2--2-----I --- rl ------ I ®it® --------------- al" i 0 I� 1- L ----- 1- --� -r low I I I I � � I TYPICAL PHOTOVOLTAIC -ARRAY PITCHED ROOF LAYOUT - WIND ZONES - SCHEDULE - PLAN SCALE: NONE 39" X 65" PHOTOVOLTAIC ALUM. SOLAR RAIL TYP 2 PLCS MODULE TYP. ARRAY. TRS 3\ C TRS . 1Z TRS TRS . T C TRS L L'MAX CANT. SEE SCH. ASPHALT SHINGLES ALUM L-FOOT - DIA ST STL LAG BOLT TYP. SEE SCH /METAL 5V ROOF TYP. FOR MAX SPAN REQ. TYPICAL PHOTOVOLTAIC MODULE ARRAY PLAN SCALE: 16'=1'-0" S.Y.P. 2X4 LOCATE BETWEEN TRUSSES AND NAIL WITH 2-16D NAIL PATTERN AT EACH END TO WOOD TRUSS 2X PT S.Y.P. WOOD UNISTRUT CONT. AL STEEL ALL-THRD OD W/ NUT - WASHERS - LOCTITE ALL NUTS TYP. ALL CONNECTIONS OPTIONAL SPANNER CONNECTION DETAILS SCALE: 1 2'=1'-0" 12" ALUMINUM INTERNAL SPLICE BAR (USE WHEN __=T===== ___________________________________,_______-____ SPLICE AT MID -SPAN W/ ------ - -_-�_- o - -_ (4) #12-14X8' ST STL SELF --------=-------------- - -- -=- ' -= TAPPING SCREWS TYP IRONRIDGE XR1000 OR XR100 #12.14X8" ST STL SELF TAPPING ALUM. SOLAR RAIL TYP SCREW TYP 4 PLCS PER BEAM SPLICE TYPICAL SOLAR RAIL BEAM SPLICE DETAIL SCALE: 1 2'=1'-0" TYP. 2 PLCS. PER SIDE OF MODULE AND BE CONNECTED < 25% OF MODULE LENGTH USE ANTI -SEIZE AND TIGHTEN TO TORQUE PER MANUF. INSTRUCTIONS REFER TO SCHEDULE FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL. b t'LQ' ALUMINUM L-FOOT TYP EVERY ROOF PENETRATION 9 3� e - 16 HEX CAP ST STL BOLT AND ST STL 'O SERRATED FLANGE -NUT TYP. t END -CLAMP W/ 4' - PHOTOVOLTAIC 20 HEX CAP ST STL MODULE TYP. - ' BOLT AND ST STL ASPHALT SERRATED SHINGLES / FLANGE -NUT TYP. IRONRIDGE XR1000 METAL 5V END -CLAMP SIZE OR XR100 ALUM. WOOD ROOFING TYP. VARIES. SOLAR RAIL TYP. SHEATHING 16" ST STL LAG BOLT. SEE WOOD ROOF SCH FOR EMBED DEPTH TRUSS TYP. REQ. TYP EACH L-FOOT TYPICAL PV SOLAR RAIL END CONNECTION DETAILt-_31 SCALE: 1 z"=1'-0" REFER TO SCHEDULE FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL. ALUMINUM L-FOOT TYP EVERY ROOF PENETRATION 8" - 16 HEX CAP ST STL BOL AND ST STL SERRATED FLANGE NUT TYP. I% m Y a 0 w PROJECT. DATE: 1 7-21.2017 DRAWN BY: JAT N � �A CHKD BY: JAT �s RECORD #: 29127 I SCALE: AS NOTED \—CENTER-CLAMP WITH 4' - 20 HEX CAP ST PHOTOVOLTAIC STL BOLT AND (1) ST STL SERRATED MODULE TYP. �\ ASPHALT FLANGE NUT TYP. \\� IRONRIDGE XR1000 OR XR100 ALUM. SHINGLES FRONT SIDE BEAM$ t SOLAR RAIL TYP. METAL 5V LOCATION. SEE T�'DE�fL� WOOD ROOFING 16" ST STL LAG BOLT. SEE�CH ; WOOD ROOF TYP' FOR EMBED. DEPTH REQ.P* ; SHEATHING TRUSS TYP. EACH L-FOOT 1 Z TYPICAL PV SOLAR RAIL MID CONNECTION DETAIL iiF SCALE: 1 2'=1'-0" DRAWING # G ��s N 7 -MN— W 0///// 11111111\\� JUL 21 2017 l POWER TABLE: DC -SIDE A B 1 500 W 240 VAC 2.08 A 60 HZ # PV MODULE 1 MANUF HELIENE MODEL 60M POWER 300 Wp-dc VOC 39.83 VDC ISC 9.59 A VMP 33.14 VDC IMP 9.13 AMP ** STC: CELL TEMPERATURE @ 25" C, SPECTRU SYSTEM A (9) MODULES/ (5) INVERTERS IN BRANCH CIRCUIT TERMINATOR CAP INSTALLED ON END OF TC-ER CABLE SYSTEM CONTINUOUS #6 AWG CU CONDUCTOR BONDING SOLAR RAIL, MODULES, AND MICROINVERTERS W/ WEEB LUGS OR MODULES AND MICROINVERTERS MAY BE BONDED TO RAIL WITH WEEB WASHERS, INTEGRATED GROUNDING MID CLAMP OR EQUIVALENT TO SIMPLIFY INSTALLATION. SYSTEM A SYSTEM B 1ST BRNCH C 2ND BRI 5 4 2500 W 2000 W 240 VAC 240 VAC 10.4 A 8.32 A 60 HZ 60 HZ 1.5, IRRADIANCE @ 1000 A T TC-ER #12 AWG CU 90 RATED INSULATED CABLE AC -SIDE INVERTER APSYSTEMS YC500 RATED POWER VOLTAGE CURRENT FREQUENCY TC-ER CABLE SYSTEM AP YC500A MICROINVERTER TYP. #6 AWG SOLID CU GROUND TYP. SYSTEM B (8) MODULES/ (4) INVERTERS IN BRANCH CIRCUIT SIMILAR GROUNDING STRATEGY AS BRANCH CIRCUIT A NEC 2011 LABELING REQUIREMENTS PHOTOVOLTAIC AC DISCONNECT MAXIMUM AC OPERATING CURRENT: 18.72 A MAXIMUM AC OPERATING VOLTAGE: 240 V (PER NEC 690.54 - PROVIDE AT EXTERNAL AC DISCONNECT OR MAIN SERVICE PANEL IF APPLICABLE) GENERAL PHOTOVOLTAIC 3-LINE DIAGRAM SPECIFIC FLAG NOTES: OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES PRIOR TO THE COMMENCEMENT OF WORK LABEL DEVICE PER NEC 690.14(C)(2), AND SECURE PER NEC 690.7(D). EQUIPMENT SHALL BE INSTALLED PER THE 2011 NATIONAL ELECTRICAL 22 CODE (NEC), ALL APPLICABLE OR GOVERNING CODES, MANUFACTURER LABEL BREAKER PER NEC 690.54, 705.12(D) AND 705.10. REQUIREMENTS OF AND PER THE GOVERNING UTILITY COMPANY. LISTING AGENT NAME AND NUMBER SHALL BE INDICATED PER NEC PV BACKFEED CURRENT PLUS MAIN BREAKER RATING MUST BE LESS THAN OR EQUAL TO 120% OF MAIN SERVICE BUS RATING AND BREAKERS MUST BE MOUNTED AT OPPOSITE END OF MAIN BREAKER PER NEC 705.12(D). CONDUCTOR WIRE SIZES SHOWN BASED SOLELY ON AMPACITY IF PV BACKFEED CURRENT PLUS MAIN BREAKER RATING EXCEEDS 120% OF REQUIREMENTS. TO PREVENT AN INCREASE IN AC VOLTAGE LEVEL AND 8 MAIN SERVICE BUS RATING, CONTRACTOR SHALL LOCATE ADEQUATELY AVOID ANY NUISANCE FAULTS, IT IS RECOMMENDED TO SIZE CONDUCTOR FOR A TOTAL VOLTAGE DROP OF 2% OR LESS PER INV. SIZED DISCONNECT BETWEEN SUB/SERVICE PANEL AND SUPPLY SIDE MANUFACTURER. CONNECTION AND COMPLY WITH NEC 705.12(A) TC-ER #11 AWG CU 90 C RATED INSULATED CABLE Ll #6 AWG SOLID CU GROUND TYP. G BRANCH CIRCUIT B TO BE CONNECTED THE SAME AS BRANCH CIRCUIT A WITH SAME INVERTER AND MODULE TYPE ALONG CABLE SYSTEM TC-ER 90 C RATED INSULATED CABLE #6 AWG SOLID CU GROUND TYP. C INVERTER OUTPUT CIRCUIT CABLE OUTDOOR / INDOOR CONDITIONS (3) # 10 AWG CU, INSULATION: THHN/THWN-2 (1) # 10 AWG CU, INSULATION: THHN/THWN-2 GROUND CONDUCTOR CONDUIT SIZE: 2" MINIMUM ATTIC SPACE / WALL INTERIOR RUN ONLY WIRING OPTION (3) # 10 AWG W/ (1) #10 GROUND NM ROMEX CABLE, OF CABLE OR EQUIVALENT A A GI I JUNCTION BOX NOTE: ALL CONDUCTORS THIS SHEET SHALL BE COPPER UNLESS OTHERWISE NOTED. NEMA 3R ENCLOSURE MAIN PV SYSTEM DISCONNECT PER NEC 690.14(2) - PROVIDE AT MAIN SERVICE PANEL ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL PER NEC 690.17 - PROVIDE AT MAIN SERVICE PANEL WARNING INVERTER OUTPUT CONNECTION - DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL PER NEC 705-12(D)(7) - PROVIDE AT MAIN SERVICE PANEL EXISTING 150 AMP MAIN SERVICE PANEL (VERIFY IN FIELD) TO EXISTING GROUNDING ELECTRODE WARNING DUAL POWER SOURCE SECOND SOURCE IS PV SYSTEM PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED LABEL PER NEC 705.12(D)(4) - PROVIDE AT MAIN SERVICE PANEL m Y 1' a 0 PROJECT: w w L. Lu U I-- Z to 0 co to ww lL c-' CV to Lu L Q N tp ce tT � Lo M w _ > Z Q u Q V Lu V L.0 w w 0 00� to d a L- DATE 7/21/2017 DRAWN BY: JAT CHKD BY: JAT REC. NO. # SCALE AS NOTED DRAWING # SLR2 SHEET 4 OF 4 TE XIMUM OF 7 INVERTERS PER ,NCH CIRCUIT PER NUFACTURER OMMENDATIONS. 1 r U