Loading...
HomeMy WebLinkAboutNOA - Shingles0 �a DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION MIAVII-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 "r (786) 315-2590 F (786) 3 t5-2599 NOTICE OF ACCEPTANCE (NOA) 17M.-Dw",iv.miamidade.gv/economy GAFST. LUCIE rnr,^m uU MPTNrG DM—'ION RANCE REVIEWED FOR COMPLI. 1. Campus Drive It2EVIL 0V'ED BY Parsippany, NJ 07054 DATE SCOPE: PLANS AND T N4UW9T AE KEPT ON JOB OR NO INSPECTION WILL BE MADE. This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the A1-IJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revolve, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the .High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline Ultra HD@ Shingles THESE PLANS AND ALL PROPOSED WORK g ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT LABELING: Each unit shall bear a permanent label with the manufacturer's name or 18 AY. f` `J�QI I statement: "Miami -Dade County Product Control Approved".* unless otherwise noted herein. ITHALL �pPU RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 13-1104.12 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. MIAMI-DADE COUNTY NOA No.: 14-1022.21. Expiration Date: 04/22/18 Approval Date: 02/05/15 Page 1 of 5 t ROOFING ASSEMBLY APPROVAL Category Sub -Category: Materials: Deck Tyne: SCOPE Roofing Asphalt Shingles Laminate Wood This approves GAF Timberline Ultra HD Shingles as manufactured by GAF described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Specifications GAF Timberline Ultra HD lot 1.3'/4"X 39'/s" TAS 110 Man- facturing Locations # 1, 2, 3, 4, 5, 6 MANUFACTURING LOCATION 1. Tampa, FL 2. Michigan City, IN 3. Baltimore, MD 4. Ennis, TX 5. Myerstown, PA 6. Tuscaloosa, AL EVIDENCE SUBMITTED Product Description Fiberglas reinforced heavy weight asphalt roof shingle, with a laminate profile. Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories, Inc. ASTM D 3462 02NK.41.809 l 1/08/02 TAS 107 02NK41811 11/11/02 TAS 107 03CA35209 10/17/03 ASTM D 3462 03NK26444 10/17/03 TAS 107 05CA42840 11/11/05 TAS 107 05CA47541 05/10/06 ASTM D3462 06CA10139 09/1.3/06 TAS 107 PRI Asphalt Technologies, Inc. TAS 100 ELK-108-02-01 10/14/03 TAS 100 ELK-084-02-01 10/30/02 TAS 100 ELK-087-02-01 10/30/02 TAS 100 GAF-046-02-01 04/05/04 TAS 100 GAF-100-02-01 11/16/08 ASTM D 3462 GAF-100-02-02 11/16/05 TAS .100 GAF-103-02-01 11/16/05 ASTM D 3462 GAF-103-02-02 11./16/05 NOA No.: 14-1022.21 MIAMI�DAD CCOUNTY Expiration Date: 04/22/18 Approval Date: 02/05/15 Page 2 of 5 LIMITATIONS 1. Fire classification is riot part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RA.S 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A', attached. 5. Nailing shall be in compliance with Detail 'B', attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade Countv Product Control Sea] as shown below. CMIAMIM-DADMECOMUN BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this material. NOA No.: 14-1022.2 t MIAMI•DADE COUNTY Expiration Date: 04/22/18 Approval Date: 02/05/15 Page 3 of 5 IDETAIL A COURSE LAYOUT Exposure NOA No.: 14-1022.21 Expiration Date: 04/22/18 Approval Date: 02/05/15 Page 4 of 5 "I. DETAIL B—13-1/4" X 39-3/8" OVERALL DIMENSIONS AND NAILING PATTERN - 1" 6 fasteners "— 72�� �- 71�� 2 �1�► 4 5-4 5-5 f - 6-4' L 1/2" Front Side (Maximum Slope 21:12) Tab Sealant 1" Back Side GAF TIMBERLINE ULTRA if END OF THIS ACCEPTANCE - Release Tape 3/8" NOA No.: 14-1022.2.1 Expiration Date: 04/22/1.8 Approval Date: 02/05/1.5 Page 5 of 5