DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
MIAVII-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
"r (786) 315-2590 F (786) 3 t5-2599
NOTICE OF ACCEPTANCE (NOA) 17M.-Dw",iv.miamidade.gv/economy
GAFST. LUCIE rnr,^m uU MPTNrG DM—'ION
RANCE
REVIEWED FOR COMPLI.
1. Campus Drive It2EVIL 0V'ED BY
Parsippany, NJ 07054 DATE
SCOPE: PLANS AND T N4UW9T AE KEPT ON JOB
OR NO INSPECTION WILL BE MADE.
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the A1-IJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revolve, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the .High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Timberline Ultra HD@ Shingles THESE PLANS AND ALL PROPOSED WORK
g ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
LABELING: Each unit shall bear a permanent label with the manufacturer's name or 18 AY. f` `J�QI I
statement: "Miami -Dade County Product Control Approved".* unless otherwise noted herein.
ITHALL �pPU
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 13-1104.12 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
MIAMI-DADE COUNTY
NOA No.: 14-1022.21.
Expiration Date: 04/22/18
Approval Date: 02/05/15
Page 1 of 5
t
ROOFING ASSEMBLY APPROVAL
Category
Sub -Category:
Materials:
Deck Tyne:
SCOPE
Roofing
Asphalt Shingles
Laminate
Wood
This approves GAF Timberline Ultra HD Shingles as manufactured by GAF described in Section 2 of this Notice of
Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test
Specifications
GAF Timberline Ultra HD lot 1.3'/4"X 39'/s" TAS 110
Man- facturing
Locations # 1, 2, 3, 4, 5, 6
MANUFACTURING LOCATION
1. Tampa, FL
2. Michigan City, IN
3. Baltimore, MD
4. Ennis, TX
5. Myerstown, PA
6. Tuscaloosa, AL
EVIDENCE SUBMITTED
Product Description
Fiberglas reinforced heavy weight asphalt roof
shingle, with a laminate profile.
Test Agency Test Identifier
Test Name/Report
Date
Underwriters Laboratories, Inc. ASTM D 3462
02NK.41.809
l 1/08/02
TAS 107
02NK41811
11/11/02
TAS 107
03CA35209
10/17/03
ASTM D 3462
03NK26444
10/17/03
TAS 107
05CA42840
11/11/05
TAS 107
05CA47541
05/10/06
ASTM D3462
06CA10139
09/1.3/06
TAS 107
PRI Asphalt Technologies, Inc. TAS 100
ELK-108-02-01
10/14/03
TAS 100
ELK-084-02-01
10/30/02
TAS 100
ELK-087-02-01
10/30/02
TAS 100
GAF-046-02-01
04/05/04
TAS 100
GAF-100-02-01
11/16/08
ASTM D 3462
GAF-100-02-02
11/16/05
TAS .100
GAF-103-02-01
11/16/05
ASTM D 3462
GAF-103-02-02
11./16/05
NOA No.: 14-1022.21
MIAMI�DAD CCOUNTY Expiration Date: 04/22/18
Approval Date: 02/05/15
Page 2 of 5
LIMITATIONS
1. Fire classification is riot part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RA.S 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail'A', attached.
5. Nailing shall be in compliance with Detail 'B', attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade
Countv Product Control Sea] as shown below.
CMIAMIM-DADMECOMUN
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by Building Official or Applicable building code in order to properly evaluate the
installation of this material.
NOA No.: 14-1022.2 t
MIAMI•DADE COUNTY Expiration Date: 04/22/18
Approval Date: 02/05/15
Page 3 of 5
IDETAIL A
COURSE LAYOUT
Exposure
NOA No.: 14-1022.21
Expiration Date: 04/22/18
Approval Date: 02/05/15
Page 4 of 5
"I.
DETAIL B—13-1/4" X 39-3/8"
OVERALL DIMENSIONS AND NAILING PATTERN
- 1"
6 fasteners "— 72�� �- 71��
2
�1�►
4
5-4
5-5
f
- 6-4'
L
1/2"
Front Side (Maximum Slope 21:12)
Tab Sealant
1"
Back Side
GAF TIMBERLINE ULTRA if
END OF THIS ACCEPTANCE
- Release
Tape
3/8"
NOA No.: 14-1022.2.1
Expiration Date: 04/22/1.8
Approval Date: 02/05/1.5
Page 5 of 5