Loading...
HomeMy WebLinkAboutRevisionFile Copy OFFICE USE ONLY: DATE FILED: -J -7 PERMIT # 0 1,2 7, REVISION FEE: RECEIPT PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 FAX (7712) 46P APPLICATION FOR BUILDING ib, SION- PROJECT INFORMA ON 1. LOCATION/SITE ADDRESS: 6-.-70) 41\4 2. 3. 4. .1 DETAILED DESCRIPTION OF PROJECT REVISIONS: . k . M E71 r';; F__ Z INFORMATION: CONTRACTOR STATE of FL REG./CERT. #: ST. LUCEE BUSINESS NAME: CE OTTALIFTERS NAME - ADDRESS: CITY: PHONE (DAYTIME): OWNER/BUILDER INFORMATION: NAME: _\ I A-" ^^ ADDRESS: 9,)/)1 CITY: PHONE: 21 ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): Revised 07/22/2014 STATE: FAX: STATE: STATE: FAX: FAX: ZIP: ZIP: 772TY7 ZIP: 2017 -Vile COPY R_'T' -" .t.fh C( IVMLIA tlrl. E ER -��� riL7 �� r,f-tjT 4 Cr�rJo QOTRINITYI__kN1S_ � __ EVALUATION REPORT Allied Building Products Corp. dba TRI-BUILT Roofing Products 9050 Louisiana Street Merrillville, IN 46410 EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (209) 262-9245 FAX: (203)'262-9243 Evaluation Report A42960.10.12-113 FL16048-R3 Date of Issuance:10/25/2012 Revision 3: 10/08/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the :5th Edition .(2014) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity ERD requires a,complete review of this Evaluation Report relative to updated Code requirements with each Code'Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall.be done in its entirety: INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for,inspection at the job site at the esi u r PO I. This Evaluation Report consists of pages 1 through 5., Prepared by: .atvtrn .• �� s� ", c3. _ k; c y�Eo-sa�aa L r �% y •ri� i �1a 1�:;•-$;�,-:OF nair. ? r-•yr.^r �r �..i5'! ;:� Robert J.M. Nieminen P.E. �iFS '`�• "t , The facsimile sealappearingwas authorized byRobert Nieminen, i l','�/vUat-E:s•l P.E on 10 rrar�rr, /08 .Th6 /2035.does not serve as an electronica8y signed Florida Registration No. 59166, Florida DCA ANE1983 ��' document. signed, sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENLE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned, -operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Rool Sub -Category: Und Compliance Statement: TRI-BOIL with the following sections of the Compliance is subject to the Instal 2. STANDARDS: Section 15071.4; 1507.18, 1507.2.9.2; 1507.4.5.1, 1507.5.3, 150777.3 1504.6 1507.3.3 1523.6.52.1 3. REFERENCES: 909LY ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) UL, I.I.C. (QUA9625) UL, LLC. (QUA9625) 4. PRODUCT DESCRIPTION: ti VTRINITYIERD' layment Roof Underlayments, as produced by TRI-BUILT, have demonstrated compliance lorida Building Code through testing'in accordance with the following; Standards. tion Requirements and Limitations / Conditions of Use set forth herein. 4.1 Self-Adherins Underiavmenta 4.1.1 Tri-Built Sand-R 'SA Shingle modified bitumen roof underl 4.1.2 Tri-Built S/A HT TU Underlay bitumen roof underlayment 4.1.3 Tri-Built Smooth HT S/A Unde bitumen roof underlayment. S. LIMITATIONS: ty Standard Year Properties ASTM D1970 2009 ated Weathering ASTM G155 2005 :ion Practice FRSA/TRI April 2012 (04-12) 2012 1 Properties TAS 103 1995 cation Reference Date 1 Properties S40540.02.43-1 02/19/2013 IProperties S40540.11.13 11/19/2013 IProperties S40540.03.14 03/26/2014 IProperties S44870.04.14-2 04/02/2014 I Properties S44870.04.14-3 64/02/2014 IProperties S44870.04.14-1 04/10/2014 IProperties 544870.04.14-4 04/10/2014 IProperties S43530.02.14-1-111 05/14/2014 IProperties 543530.05.14 09/28/2014 IProperties S40540.10.14 10/31/2014 I Properties SC7645.02.15 02/13/2015 ated Weathering SC8520.04.15 05/27/2015 Control Multiple -Listing R16814 09/04/2015 Control Service Confirmation Exp. 10/16/2017 erlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SBS lent, with a 36-inch sheet width. it is a self -adhering, non -woven polyester fabric surfaced, SBS modified is a self -adhering, glass=mat reinforced, film -surfaced, SBS modified 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are,'in any way, the Designer of Record for any project on- which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this.pr,oduct. Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-R3 Certificate of Authorlmtion #9503 FL16048-Ft! Revision 3:10/08/2015 Page 2 of 5 ��TRINITYJERD 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within ,FBC approval documents. If not listed, a request may be made to the AHJ. for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers applied atop the underlayments are as follows: TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Shingles Nail-On,Tile Foam -On Tile Metal Wood Shakes &Shingles Slate Tri-Built Sand-R SA Shingle Yes No No No Yes Yes Underlayment Tri=Built S/A HT TU Yes Yes Yes Yes Yes Yes Underlayment See 5.54 Tri-Built Smooth HT S/A Yes No No Yes Yes Yes Underiaymment 5.5.1 "Foam -:On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ➢ Tri-Built S/A HT TU Underlayment with 3M'" 2-Component Roof Tile Adhesive AH-160 (FL6332) or Dow TH613oncllm ,Roof Tile Adhesive.(FL717) 5.6 Allowable substrates are noted below: 5.6A Direct -Bond to Deck: Tri-Built Sand-R, SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; ASTM D41 primed structural concrete. While not required over plywood, OSB or Southern Yellow Pine Substrates, TRI-BUILT recommends priming the deck if the final roof cover is not slated for installation, within 24 hours. Note: TRI-BUILT requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self - adhering underlayment. 5.6.2 Bond -to -Insulation: Tri-Built S/A HT TU Underlayment applied to: ➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on the systems, insulation attachment shall be designed by a qualified design professional and installed based on. testing of the insulation/underlayment system in accordance with FM 4474, Appendix D or TAS 114, Appendix J. 5.6.3 Bond to Mechanically Attached Base Laver: ➢ ASTM D226, Type I or II felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12). Exterior Research and Design, I.I.C. Evaluation Report A42960:10.12-R3 Certi lcate of Aothorizatlon #9503 FL16048-R3 Revision 3:10/68/2015 Page 3 of 5 TRINITY I ERD 5.6.4 Wind Resistance for Underlavment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on the systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck underlayment systems that arenot addressed in FRSA/TRI April 2012 (0442) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 15.04.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures. 5.6.4.1 Maximum. Design Pressure = -45M psf. Deck: Min. 15/324nch plywood to meet project requirements to.satisfaction of AH1. Primer: (Optional) ASTM.D41 Underlayment: Tri=Built S/A HTTU Underlayment, self -adhered. 5.7 Exposure Limitations: I 5.7.1 Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than 5b-days: after installation 5.7.2 Tri=Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation. 6. INSTALLATION: 6'.1 TRI-BUILT Roof Underlay rents shall be installed in accordance with' TRI-BUILT published installation requirements subject to the Limitations set -forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose.decking panels, and check for protruding nail heads. Sweep .the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 63 Tri-Built Sand-R SA ShinalJ Underlayment, Tri-Built S/A HT TU Underlavment. or T68uilt Smooth HT S/A Underlayment: 6.3.1 Shall be installed in compliance .with the requirements for ASTM D1970 underlayment in FBC'Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile applications: While priming is optional, TRI-BUILT recommends priming the deck -if the final roof cover is not slated 'for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. II Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel -off, the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and, staggered not less�than 2-ft from vertical seams in the course below. All over:granule end -laps shall be sealed using -either heat -welding or hot air welding techniques: When installing at slopes above 8:12, Allied Building Products Corp recommends back -nailing in the overlap area at the top -of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center.sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys, appi y the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications (Tri-Built S/A HTTU Underlayment only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Exterior Research and Design, I.I.C. Evaluation Report A42960.10AZ-113 Certijkate of Authorization #9503 FL16048-R3 Revision 3:10/08/1015 Page 4 of i V��TRINITYJERD 7. BUILDING PERMIT REQUIREMENTS: As.required by the Building Official or Authority Having Jurisdiction :in order to properly. evaluate :the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information. on product locations covered for F.A.C. Rule 9N-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report A41060.30.12-R3 CerWleate ojAuthorl:atfon #9503 FL16648-R3 Revision 3:10/M/2015 Page 5 of 5 QOTRINITYIERD APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4 1A-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5 1B Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 5 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 6 1D Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 6 1E-1 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 7 lE-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 8 1F Wood New or Reroof (Tear -Off) F Non -insulated, Bonded Roof Cover 8 2A Steel or Conc. New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9 2B Steel or Conc. New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 10 2C Steel or Conc. New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 11 3A-1 Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 12-14 3A-2 Concrete New or Reroof (Tear -Off) A-1 Bonded Temporary Roof, Bonded Insulation, Bonded Roof Cover 15 3B Concrete New or Reroof (Tear -Off) F Non -insulated, Bonded Roof Cover 15 - 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 16-17 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 17 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 18-20 SA CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 21 5B CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 22 5C CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 22 SD CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 23 5E CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 23 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 24 6B Gypsum New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 25 6C Gypsum New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 25 6D Gypsum New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 25 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 26-27 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 27 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, Dens Deck, Dens Deck Prime, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board that meets the CIA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover. Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report A42970.10.12-R1 for FL16027-RI Certificate of Authorization #9503 Revision 1: 03/23/2015 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 1 of 27 QOTRINITYIERD 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. S. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ HA (HA): Full coverage at 25-30lbs/square. ➢ Dow Insta-Stik Roofing Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ 3M CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. i 6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered-polyisocyanurate-arthe fallowing thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values-be.used-to'increase'-the MDP --listings the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board -listed -below -may ba dro e used as p-in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) ➢ OMG OlyBond 500 (08500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) ➢ OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+ GL) ➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3) ` ➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II) ➢ 3M CR-20: MDP -117.5 psf (Min. 1.0-inch thick) _ 7. Bonded polyisocya nu rate insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 9. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 11. For existing substrates in a bonded recover installation, the existing roof system shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124. 12. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. 13. LWIC shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. For systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report A42970.10.12-111 for FL16027-R1 Certificate of Authorization #9503 Revision 1: 03/23/2015 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 27 NTINITYIERD 14. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. TABLE 1: TRI-BUILT ROOF COVERS Reference Layer Material Application BP -AA Base FBC Approved ASTM D4601, Type II HA at 20 40 Ibs/square Ply FBC Approved ASTM D2178, Type IV or VI (Base and Ply sheets, Asphalt -Applied) SBS-AA Cap TriBuilt SBS Granular HA at 20-40 Ibs/square (SBS, Asphalt -Applied) SBS-TA Cap TriBuilt SBS Granular Torch -Applied (SBS, Torch -Applied) SBS-SA Base TriBuilt SA SBS Base Self -Adhering Cap TriBuilt SA SBS Cap (SBS, Self -Adhering) APP-TA Base or Ply TriBuilt APP Smooth Torch -Applied Cap TriBuilt APP Smooth, TriBuilt APP Granular (APP, Torch -Applied) APP-SA Cap TriBuilt SA APP Cap Self -Adhering (APP, Self -Adhering) 15. The following represent priming requirements for gypsum -based coverboards: ➢ Dens Deck and Dens Deck Prime shall be field -primed with ASTM D41 primer prior to self -adhering or torch -applied membrane application. No priming is required for hot -asphalt membrane applications. ➢ SECUROCK Gypsum -Fiber Roof Board does not require field priming for any membrane application. 16. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. t60 i\'Ck V Exterior Research and Design, LLC. d/b/a Trinity] ERD Evaluation Report A42970.10.12-111 for FL16027-R1 Certificate of Authorization #9503 Revision 1: 03/23/2015 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 3 of 27 QoTpuNITYIERD TABLE 1A-1: WOOD DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover MDP No. (See Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Cap (Psfl Min. 0.25-inch Dens 8-inch o.c. in 4- Deck, Dens Deck Prime, Polyglass G2 Base, 32 ga., 1-5/8- inch lap and 8- (Optional) FBC SECUROCK Gypsum - Min. 19/32- CertainTeed Glasbase, inch diameter inch o.c. in Approved, Fiber Roof Board, Min. SBS-AA, W 1 inch plywood Firestone MB Base, tin caps with 11 three, equally ASTM C1289, HA 0.75-inch FescoBoard HA BP -AA (Optional) SBS-TA, -60.0 max. Tamko o a annular ringspaced, g � p type II of iso- Yp p y (homogeneous) or min. ( g ) BP APP-TA spans inch spans in Glass Base or GlassPermBase or shank nails staggered cyanurate 0.5-inch Structodek GAFGLAS #75 center rows High Density Fiberboard Roof Insulation __ Polyglass G2 Base, ------ —32 ga:, 1=5%8— 8-inch o.c. in4— inch lap and 8- �--- (Optional) FBC (Optional) —Min. 19/32— —CertainTeed Glasbase, Min. 0.25-inch Dens SBS-SA, inch plywood Firestone MB Base, JM inch diameter inch o.c. in Approved, Deck, Dens Deck Prime, One or APP-SA, W-2 at max. 24- Perma-Ply 28, Tamko tin caps with 11 three, equally ASTM C1289, HA SECUROCK Gypsum- HA SBS-SA more SBS- SBS-TA or -60.0 inch spans Glass Base or ga. annular ring spaced, type II polyiso- Fiber Roof Board SA or APP-TA GAFGLAS #75 shank nails staggered cyanurate APP-TA center rows 6-inch o.c. in 4- Min. 2-inch DAS, OBS00, Min. 19/32- 32 ga., 1-5/8- inch lap and 6- ACFoam II, III, CR-20 or M- Min. 0.25-inch Dens D-IS, irich plywood Polyglass Elastobase inch diameter inch o.c. in H-Shield, H- OSFA, atop Deck, Dens Deck Prime OB500, (Optional) SBS-AA, W 3 at max. 24- or Polyglass tin caps with 12 four, equally Shield CG, fastener or SECUROCK Gypsum- CR-20 or BP AA BP -AA SBS-TA, -60.0 inch spans Elastobase Poly ga. annular ring spaced, Multi -Max FA3 rows, 7-inch Fiber Roof Board M-OSFA APP-TA shank nails staggered center rows or ENRGY-3 oc 6-inch o.c. in 4- Min. 2-inch D-IS, OB500, 32 ga., 1-5/8- inch lap and 6- (Optional) Min. 19/32- Polyglass Elastobase inch diameter inch o.c. in ACFoam II, III, CR-20 or M- D-IS, One or SBS-SA, W-4 inch plywood or Polyglass tin caps with 12 four, equally H-Shield, H- OSFA, atop (Optional) Additional OB500, SBS-SA more SBS- APP-SA, -60.0 at max. 24- Elastobase Poly ga. annular ring spaced, Shield CG, fastener layers of base insulation CR-20 or SA or SBS-TA or inch spans shank nails staggered Multi -Max FA3 rows, 7-inch M-OSFA APP-TA APP-TA center rows or ENRGY-3 oc Exterior Research and Design, LLC. d/b/a Trinity[ ERD Evaluation Report A42970.10.12-R1 for FL16027-R1 Certificate of Authorization #9503 Revision 1: 03/23/2015 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 4 of 27 . �! TRINITY I ERD TABLE 1E-2: WOOD DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Base Sheet Roof Cover MDP No. Deck (See Note 1) Base Fasteners Attach Ply _Cap (psf) Min. 19/32-inch Polyglass Elastobase, Polyglass Elastobase OMG Flat Bottom Plates (square) with 12-inch o.c. in 4-inch lap and 12-inch (Optional) One or W-1 plywood at max. Poly, Polyglass G2 Base, CertainTeed Roofgrip #14, Dekfast Hex with Dekfast #14 o.c. in two, equally spaced, staggered more BP -AA or SBS-AA, SBS- -52.5 24-inch spans e, Firestone MB Base, Gy or TruFast MP-3 with TruFast-HD center rows APP-TA TA, APP-TA AF LAS #7 Ply 28, Tamko Glass Base or GAFGLAS #75 28, Min. 19/32-inch Polyglass Elastobase or Polyglass Dekfast Hex with Dekfast #14 or TruFast MP- 12-inch o.c. in 4-inch lap and 12-inch One or more SBS- SBS-SA, APP- W-2 plywood at max. Elastobase Poly with poly top surface 3 with TruFast HD o.c. two, equally spaced, staggered SA SA, SBS TA or 52.5 24-inch spans center rows APP-TA Min. 19/32-inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with 12-inch o.c. in 4-inch lap and 12-inch (Optional) One or SBS-AA, SBS- W-3 plywood at max. Elastobase Poly Roofgrip #12 o.c. in two, equally spaced, staggered more BP -AA or TA, APP-TA -60.0 24-inch spans center rows APP-TA Min. 19/32-inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with 12-inch o.c. in 4-inch lap and 12-inch One or more SBS- SBS-SA, APP- W-4 plywood at max. Elastobase Poly with poly top surface Roofgrip #12 o.c. in two, equally spaced, staggered SA SA, SBS-TA or -60.0* 24-inch spans center rows APP-TA TABLE 1F: WOOD DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System Roof Cover MDP No. Deck Primer (psf) Joint Treatment Base Ply Cap Y1!-5 ',. Min. 15/32=ihch plywood M OptionaQ ASTM D4 None SBS-SA (Optional) SBS-SA or SBS-SAf APP-SA, SBS -TA i90.0 -� at.max_24-inch-span sq APP-TA or APP-TA W 6 Min. 15/32-inch plywood (Optional) ASTM D41 Plywood joints are covered with 4-inch wide strips of TriBuilt SA TriBuilt SA SBS Base (Optional) SBS-SA or SBS-SA, APP-SA, SBS-TA 97.5 at max. 24-inch spans SBS Base, rolled into place to create continuous bond. APP-TA or APP-TA r- Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report A42970.10.12-R1 for FL16027-R1 Certificate of Authorization #9503 Revision 1: 03/23/2015 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 8 of 27