Loading...
HomeMy WebLinkAboutReview - -Comments0810812017 15:30 LUVIANO ROOFING TAR)863 357 3566 P.0021017 32--./ffal;p ev"f J:�t" Planning 8 Development Services Building S Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34062 Phone:(772)462-2172 Fax:(7721462.0443 PROPERTY INFORMATION Address; 16471 Highway 70 East City I State I Zip: Fort Pierce, FI 34972-8262 Parcel 0. 3131-111-0001-00010 Zoning: AG-5 APPLICATION INFOOMT10N Permit Number; 1708-0157 Permit Type: ROOF - METAL REVIEW COMMENTS Page 1 _Owner(s)., Family Tree Enter Limited Prtn Jurtsdictlon; SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No CONTRACTOR INFORMATION Contractor Name: Osiel Luviano Fax Number: 863-357-3560 Business Name: Luvlano Roofing Co Inc Email: Osiel@Luvienogroup.Com Buelneea Addr 11055 Hwy 441 N 1 City I State / Zip: Okeechobee, FI 34972 REVIEWS ANQ COMMENTS Ravlow Tyne FRONT COUNTER REVIEW $latUS Rovif od By Data Started Date Completed Date Releeeed COMPLETE Angela Huff 01712017 0/7/2017 8/7/2017 Comment FLANS EXAMINER REVIEW INCOMPLETE Ofa-Engineer 6/8/2017 Pos.4 CommenL PLEASE SPECIFY THE EXACT UNDERLAYMENT TO BE USED FOR FL 5259 AS THER ARE 10 SELF ADHERED 802017 UNDERLAYMENTS TO CHOOSE FROM. V01-9-Comment PLEASE PRINT IN DUPLICATE THE COVER PAGE FROM DBPR FOR THE POLYGLASS UNDERLAYMENT FL 818/201T 5259 AS REQUIRED .� UO Comment: PLEASE PRINT IN DUPLICATE THE COVER PAGE FROM Dapn FOR THE GULF COAST METAL. PANEL FL 8/8l2017 11551.17 AS REQUIRED Comment: PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE $1812017 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS Comment: PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER 8/8/2017 (a ST. LUCIE COUNTY RESOLUTION #13-196 8/812017 6 ` ..Comment: COMMENTS SENT 8017 0810812017 15:31 LUVIANO ROOFING TAX)863 357 3566 P.0031017 C�YM 4.2.4 Polystick TU Plus Is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 an�TTAS 3.4.2.5 sa nominal 130-mil thick ed asphalt waterproofing membrane, �Slass-fib�erlpolye�_$ter reinforced, with a granular surface; meets ASTM D1970 and TAS 103. 4.2.6 Polystick TU Max Is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface; meets ASTM D1970 and TAS 203. 4.2.7 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP ,Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. 4.2.8 Polystick Dual Pro"" Is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970. 4.2.9 Polystick Tile Prom is a no 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D2970 and TAS 103. 4.2.10 Potystick MU-X Is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section 5.8). 4.3 Mechanically Fastened and/or Bonded Underlayments: 4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of an sand -surfaced S65 modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2022 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered the roof systems. 4.3.2 Elastoflex SG G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164. Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll, Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems. Elastoflex 56 G Is for use as an alternate to Hot Asphalt applied "Cap Sheet' in the "Two Ply System" from FRSA/TRl April 2012. (04-12) beneath mechanically fastened or adhered file roof systems. Elastoflex S6 G FR is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex G is for use as an alternate to Heat Applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-22) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR Is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. S. LIMITATIONS: 5.1 This Is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report Is not for use in the HVHZ. 5.3 Fire Classification Is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5A Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with Supporting data for the prepared roof covering. Exterior Research and Deign, LLC, Evaluation Report P12060.02.09-1122 certblcare ofAuthariratlon #9503 FBC NON-HVHZ WAWA1n0N FLSZ59-R16 Polyglass USA, Inc. Revision 22: 03/13/2017 Page 4 of 14