Loading...
HomeMy WebLinkAboutLetter - GFA engineer1 0810812017 15:06 LUVIANO ROOFING r )863 357 3566 "P.001 l017 LUVIANO ROOFING CO., INC. 1963 US HWY 98 NORTH OKEECHOBEE, FL 34972 FACSIMILE TRANSMITTAL SHEET. TO: FROM: GFA — ENGINEER Osiel Luviano COMPANY: DATE: GF A, AUGUST 8, 2017 FAX NUMBER: TOTAL NO. OF PAGES INCLUDING COVER: 1.772.462.1578 17 PHONE NUMBER: COPY: File RE: ORIGNAL TO FOLLOW VIA: PERMIT# 1708-0156 — RLVIEW COMMENTS .RfURGENT ❑ FOR REVIEW © PLEASE COMMENT m PLEASE REPLY 121 FOR YOUR USE. NOTESICOMMENTS: TO WHOM IT MAY CONCERN; PLEASE SEE ATTACHED REQUESTED DOCUMENTS FOR EACH COMMENT -- PLEASE CALL ME OR EMAIL IF ANY QUESTIONS OR CONCERNS. EACH COMMENT HAS BEEN ADDRESSED AS REQUESTED PER ORDER OF COMMENTS. TELEPHONE 863/357-3838 FAX 863/357-3566 - 0810812017 15:06 LUVIANO ROOFING TAX)863 357 3566 P.0031017 ��TRINITYJERD 4.2.4 Polystick TU Plus Is a nominal 80-mll thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a olyester fabric surface; meets ASTM D1970 and TAS 103. 4.2.5 PolystiCk na 0-mIl thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface; meets ASTM D1970 and TAS 103. 4.2.6 Polystick TU Max Is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m' polyester fabric surface; meets ASTM D1970 and TAS 103. 4.2.7 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester reinforced, APP modified bitumen cap sheets; meet ASTM 06222. 4.2.9 Polystick Dual Pro^' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970. 4.2.9 Polystick Tile Prom Is a nominal 60-mll thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. 4.2.10 Polystick MU-X .is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section 5.8). 4.13 Mechanically Fastened and/or Bonded Underlayments: 4.3.1 Elastoflex G TU Is a polyester reinforced, modified bitumen tile underlayment composed of an sand -surfaced SOS modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU Is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM 06380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-22) beneath mechanically fastened or adhered the roof systems. 4.3.2 Elastoflex S6 G and Elastoflex SG G FR are polyester reinforced, SOS modified bitumen cap sheets; meet ASTM 06164. Flastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex SG G FR Is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems. 4.3.3 Polyflex,G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex G Is for use as an alternate to Heat Applied "Cap, Sheet" in the. `Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered file roof systems. Polyflex G FR is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012. (04-12) beneath mechanically fastened tile roof systems. S. LIMITA110NS: 5.1 This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report Is not for use in the HVHZ. 5.3 Fire Classification Is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation Combined with supporting data for the prepared roof covering, Exterior Research and Design, us. Evaluation Report P12060.02.09-R22 cefflocore ofAuthorkatloa #9503 FBC NON-HVHZ EVAWATION F15259-1126 Polygiass USA, Inc. Revision 22: 03/13/2017 Page 4 of 14 08/0812017 15:06 LUVIAHO ROOFING TA1)663 357 3566 P.0021017 �",,�esrsz�a• �rwt� , Planning & Development Services Bubtling 8 Code Regulation Divioton 2300 Virginia Avenue Fort Pierce, FL. 34902 Phone:17721452 2172 Fax:(MId824W PROPERTY INFORMATION Address: 16471 Highway 70 East City I State / Zlp: Fort Pierce, FI 34972-8262 Parcel 9: 3131-111-0001-000/0 Zoning: AG-5 REVIEW COMMENTS Ownar(s): Family Tree Enter Limited Prtn Jurisdiction: SAINT LUCIE COUNTY LoW., Block: I ADPLICATION INFORMATION Permit Number: 1708-0156 Stories: Automatic Sprinkler System? No Permit Type: ROOF - METAL COMMACTOR INFORMATION Contractor Name: Osiel Luviano Fax Number: 863-357-3566 Business Name: Luviano Roofing Co Inc Business Addr: 11055 Hwy 441 N Email: Oslel@Luvianogroup.Com City / State / Zip: Okeechobee, FI 34972 REVIEWS AND COMMENTS Statua Ravla 6f@d By Data Started Date Completed Onto Reloaeed COMPLETE Angela Huff BIT/2017 8fr/2017 Bf7/2017 Review Tyne FRONT COUNTER REVIEW Comment.. PLANS EXAMINER REVIEW INCOMPLETE Oft -Engineer 8/812017 8/8/2017 Comment: PLEASE SPECIFY THE EXACT UNDERLAYMENT TO BE USED FOR FL 5259 AS THER ARE 10 SELF ADHERED UNDERLAYMENTS TO CHOOSE FROM. Comment: PLEASE PRINT IN DUPLICATE THE COVER PAGE FROM DBPR FOR THE POLYGLASS UNDERLAYMENT FL 8/8/2017 5259 AS REQUIRED 8/812017 Comment: PLEASE PRINT IN DUPLICATE THE COVER PAGE FROM DBPR FOR THE GULF COAST METAL PANEL FL 11651.17 AS REQUIRED Comment: PLEASE NOTE THATTHE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE 8/8/2017 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS 8/8/2017 Comment PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST. LUCIE COUNTY RESOLUTION #13-196 B/8/2017 Comment COMMENTS SENT 918117