HomeMy WebLinkAboutGenerator Addition Riser DiagramABBREVIA'nONS: AC ALTERNATING CURRENT MCC MOTOR CONTROL CENTER A/C AIR CONDITIONING MOP MAIN DISTRIBUTION PANELBOARD Al. ALUMINUM MTS MANUAL TRANSFER SWITCH AHU AIR HANDLING UNIT MLO MAIN LUGS ONLY ATS AUTOMATIC TRANSFER SWITCH NEC NATIONAL ELECTRICAL CODE AMP AMPERE NEMA NATIONAL ELECTRICAL MANUFACTURERS AFCI ARC FAULT CIRCUIT INTERRUPTER ASSOCIATION ANSI AMERICAN NATIONAL STANDARDS INSTITUTE NFPA NATIONAL FIRE PROTECTION ASSOCIATION C CONDUIT PLCS PLACES (QUANTITY) CU COPPER CONDUCTOR PNL PANEL COVB CITY OF VERO BEACH PVC POLYVINYL CHLORIDE CONDUIT DC DIRECT CURRENT RMC RIGID METAL CONDUIT EXIST EXISTING RTU ROOF TOP UNIT FPL FLORIDA POWER & LIGHT TYP TYPICAL G GROUND TEMP TEMPORARY GFCI GROUND FAULT CIRCUIT INTERRUPTER UG UNDERGROUND IRC INDIAN RIVER COUNTY UL UNDERWRITERS LABORATORY KVA KILOVOLTAMPERE UON UNLESS OTHERWISE NOTED KW KILOWATT V VOLT MC METAL CLAD CABLE VA VOLT AMPERE MCB MAIN CIRCUIT BREAKER W WATT XFMR TRANSFORMER (EXISTING) (2) #410 XHHW AL (LINE) (1) #410 XHHW AL (NEUTRAL) i ATTIC (EXISTING) 2' PVC CONDUIT (2) #4/0 THHW AL (LINE) (1) #410 THHW AL (NEUTRAL) (1) #6 THHN CU (GROUND) (EXISTING) #4 BARE CU IN 112" CONDUIT COLD WATER BOND (EXISTING) #4 BARE CU IN 1/2" CONDUIT GRADE (EXISTING) (2) 5/8" X 8' CU GROUND RODS 2" PVC CONDUIT 1 1/4" PVC CONDUIT W/ #4/0 SER AL (2) #3 THHN CU (LINE) (1) #3 THHN CU (NEUTRAL) (1) #8 THHN CU (GROUND) (NEW) (NEW) (EXISTING) i (EXISTING) I 0200 AMP 200 AMP 200AMP 100AMP FEED GENERAC MLO SUB -PANEL (EXISTING) j 20AMP THROUGH BE RATED INTERIOR PANEL PANEL ATS I HOUSE METERIMAIN PANEL COMBO 120/2401 ¢ (NEW) 6"x6"x36"LONG 311 TROUGH (EXISTING) WATER LINE SCOPE OF WORK: • PROVIDE AND INSTALL 200AMP FEED THROUGH PANEL, 200 AMP SE RATED ATS NEXT TO FPL METER CAN ON EXTERIOR WALL. PROVIDE AND INSTALL 6"WIDEx6"DEEPx36'LONG NEMA 3R WIRE TROUGH BELOW EXISTING METER MAIN AND NEW PANELS. • SHALL BE UTILIZING A PRE -FABRICATED PAD. SEE DETAILS ON SHEET E3. • PROVIDE AND INSTALL (1) 48kW GENERAC LP GAS GENERATOR. • PROVIDE AND INSTALL CONDUIT AND CONDUCTOR FROM NEW GENERATOR TO NEW ATS. • GENERATOR NEW LP GAS CONNECTION FROM EXISTING 500 GALLON TANK BY FERRELLGAS AS A SUBCONTRACTOR UNDER THIS PERMIT. • NO NEW BRANCH CIRCUIT LOADS SHALL BE ADDED TO HOUSE PANEL UNDER THIS SCOPE OF WORK. 2" PVC CONDUIT (2) #410 THHW AL (LINE) (1) #410 THHW AL (NEUTRAL) (1) 116 THHN CU (GROUND) 1-1/4" PVC CONDUIT (2) #310 THHW CU (LINE) (1) #310 THHW CU (NEUTRAL) (1) #6 THHW CU (GROUND) 314" PVC CONDUIT W/ (7) #14 THHN CU. (NEW) GENERATOR: AIR COOLED GENERAC48KW ® 200AMP BREAKER ATTIC GRADE GENERAL NOTES: • THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICE ROUGH IN AND INSTALLATION DETAIL WITH THE LOCAL UTILITY POWER COMPANY. • THIS ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE LOCAL ORDINANCE, AND THE NATIONAL ELECTRIC CODE, PRESENTLY IN EFFECT. I • ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AN CRAFTSMAN LIKE MANNER BY PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF A MASTER ELECTRICIAN LICENSED IN THE STATE OF FLORIDA. • THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SECURELY SUPPORTED AND FASTENED, WITH WORKING SPACE PER NEC 110.26. • PVC SCHEDULE 40 CONDUIT SHALL BE USED UNDERGROUND, IN OR BELOW CONCRETE AND WHERE EXPOSED NOT SUBJECT TO DAMAGE. PVC SCHEDULE 80 CONDUIT SHALL BE USED WHERE EXPOSED, SUBJECT TO DAMAGE. • ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGNIZED TESTING LABORATORY. • GROUNDING PER NFPA 70 2011 EDITION ARTICLE 250. I • STANDBY SYSTEM INSTALLATION PER NFPA 70 2011 EDITION ARTICLE 702, AND MANUFACTURER INSTALLATION INSTRUCTIONS. NO $ T,F. GENERATOR ADDITION RISER DIAGRAM GENERAL NOTES: 1. LIGHT LINE WORK REPRESENTS EXISTING TO REMAIN. 2. LIGHT / DASHED LINE WORK REPRESENTS EXISTING TO BE REMOVED. 3. DARK AND RED LINE WORK REPRESENT NEW EQUIPMENT, CONDUIT, AND WIRE. GENERAC' COMPLETE ELECTRIC INC. 637 SEBASTIAN BLVD. SEBASTIAN, FL 32958 (772)388.0533 Sizing Report Rated Nominal Voltage 240 Generator Fuel Choice Propane String Method (NEC 220) Part IV (Pert III required for selected circult Implementation, Both valid for whole house) General Lighting & Receptacles Load (WV) Square Footage Being Covered (f A2) 3!>00 10.6 Small Appliance Circuits (20 amps) Kitchen Circuits 2 3 Laundry Circuha 2 3 Managed Estimated Nameplate Flzed-In•Piece Appllene¢98 Motors Loads (kM (amps) 240V Load (kM Dryer 6.6 X 5.5 Microwave 1.3 1.3 Oven 5.0 X 6.o Dishwasher 1.5 1.6 Refrigerator 0.8 0.8 Dishwasher 1.6 1.5 Refrigerator 0.8 0.8 Pool Pump 2.0 20 Managed Estimated Nameplate Air Conditioning & CooHna Loads (kW) (am") 240 V Loed IkW) 1.6 Ton Unit I's X 1.6 2.0 Ton Unit 2.0 X 20 3.0 Ton Unit 3.0 X 3.0 Managed Estimated Nameplate Fleati 8 Heat PumpsLoads (kW) (amps) 240 V Load h ng .1 ement 0.0 40 X 9.6 healing element @2 0.0 28 X 6.7 healing element #3 0.0 28 X 6.7 Estimated Actual Utilized Trenslant Reculrement (.RA) (LRA) (LRA) 77 s U,x �r Z ���� USN Q' z Cl) co U¢LyLO o cub LZ co U LU Q m M WIJU IJU O U 6 \ \ "V'O U �0-) W W �w QO -ate, W O (9 WQ 0 Q Largest Motor's Stanhrg Amps (LRA) 276 77 j rn 0 Go LL.v O V t7 Summary NEC Load Load (kM NEC Required of O0 W tJi General Ughting & Receptaclea 16.5 W g Fixed -In -Place Sum of all General Loads 34.9 19.9 V oo U Ill f W W Z W_ Cooling 6.5 6.6 im g 0 Heating (w/demand factors) 23 23 W 0 Q Larger of Heating & Cooling 23 23 O S[Ang based on requirements of NEC Article 220, Pert IV 43 Z N LL Elevation Oft Minimum size generator for motor starting requirements 11 BTU load required _ 779940 _ -- 45 kW Generao Model Generator Recommended E1 rn :08108/2017 q --- 1 OF 3 (NEW) ATS LOCATION (NEW) 200AMP FEED THROUGH PANEL LOCATION (EXISTING) UTILITY METER LOCATION SINGLE FAMILY \ RESIDENCE 2302 ATLANTIC BEACH BLVD. \ FORT PIERCE, FL. 34949 3'-0" \ 10'-0" \ 0 DRIVEWAY \ oo Pao \ < Oov PARTIAL SITE PLAN Way E (NEW) 41"x83" PRE -FABRICATED GENERATOR PAD LOCATION (EXISTING) 500 GAL. LP TANK LOCATION 83" 41" --{ TOP VIEW F- — 41' LEFT ELEVATION NOTE: USING PRE -FABRICATED GENERATOR PAD. SIMILAR TO GENERAC GENPAD LC. SEE SHEET E-3. DETAIL IS FOR REFERENCE ONLY. REFER TO PRE -FABRICATED PAD MANUFACTURERS INSTRUCTIONS FOR MOUNTING HARDWARE, LOCATIONS AND PHYSICAL DIMENSIONS, I— 83" -{ FRONT ELEVATION NO $C Am GENERATOR PAD DETAIL m x� z c u� m UR'N Q' Z cl) U Q J o LL LJU LU <OD � LU W � � m LU co U �E7 rn Ld U Elew w Z og a ww zt= (U) > p> 0Qm LL chi Q m L L w ~ Z of wwzw WiL wa� Z Np OLL E2 v, 08/08/2017 2OF3 GENERAC® L RE GenPad LC's unique Fiber Reinforced Concrete delivers 8000 PSI compression strength. The LI ®114MOLED Superiortotraditionalpoured concrete. Generator Pad Solution LESS GenPad LC is stronger and weighs 50% less than concrete, GENPAOM'mEIGHT — A 61FTING Easy Placement. Our 5/8" lifting Insert accommodates an eye -bolt and Exclusively INSERT sling to mechanically place the GenPad LC. 1 1P NOCKOUT CONDUITFEED_ I/2" MOUNTING f INSERTS ,U PAD ALIGNMENT 5/8" LIFT GUIDE .% . UNIT POSITIONINGC' jF=jLff GENERACPART #10000005,771 GUIDE I Easy Alignment. The GenPad LC Pads has indentations to ensure perfect pad alignment. UNtT aosmowwo Easy Positioning. Edge to edge positioning is made simple with the GenPad LC guides. These visual markings eliminate the guesswork of ' GUIDE proper positioning. e CONDOR KNOCK_OUT 6" x 6" knockouts are designed for conduit feed direct) Into the ' generator base. Tapping the section out provides full access. CLIP NOUNTING GenPad LC's unique clip mounting system provides the most flexibility and 8-polnt connections. t SYSTEM �e - - - - 1 TOTAL PACKAGE One Pallet - Everything included. Each GenPad LC kit is shipped on its own pallet with mounting hardware included. - FREEZE/ The GenPad LC design provides superior resistance to freeze/thaw ram......_ TNAw RESIST climate conditions. GENERAC DEALER REVIEWS OF GENPAD' "1 am SOLD on this pad. We installed this _ .._: "My installation team is spoiled for life and we 48kW unit with three men in one day." I.- can't do without them now." -- --- - i "Excellent product, easy to install, good looking __ _ _ "I was very satisfied and would recommend tt i finished product. You're going to be hard-pressed �. to other dealers. The ease of installation makes to find an easier installation than this." the decision of using these LC pads easy." NO SCALE PRE -FABRICATED GENERATOR PAD DETAIL ' U 3 2 Z C Z � om V N tYZMM W E" LL 9 LLJ :5 i g LJ < m U) O U r -! JLLJ CEO �O7 �W 0 VOQ W QLU0 w Zo (D (L rr a a � J � p mrn LLo=A ULL 00 W Z X wwZw a w¢0 O Z � LL N E3 08/08/2017 3OF3