FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: FRIEDRICH RESIDENCE
Builder Name:
Street: 260 MARINA DRIVE
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL ,
Permit Number:
Owner: RICHARD & NICOLE FRIEDRICH
Jurisdiction:
Design Location: FL, West Palm Beach
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (3305.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=9.0 3305.00 ftz
b. N/A
R= ftz
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 4
d. N/A
R= ftz
5. Is this a worst case? No
10. Ceiling Types (2075.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2075.00 ftZ
6. Conditioned floor area above grade (ft2) 2919
b. N/A
R= ftZ
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
11. Ducts
R ftz
7. Windows(320.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: LAUNDRY
6 425
a. U-Factor: Dbl, U=0.32 160.00 ftz
b. Sup: Attic, Ret: Attic, AH: A/C
6 225
SHGC: SHGC=0.22
b. U-Factor: Dbl, U=0.35 96.00 ftz
12. Cooling systems
kBtu/hr Efficiency
• SHGC: SHGC=0.20
a. Central Unit
36.0 SEER:16.50
b. Central Unit
17.6 SEER:16.00
c. U-Factor: Dbl, U=0.29 40.00 ftz
SHGC: SHGC=0.23
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 24.00 ftz
a. Electric Strip Heat
27.0 COP:1.00
SHGC: other (see details)
b. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average Overhang Depth: 5.300 ft.
Area Weighted Average SHGC: 0.214
14. Hot water systems
a. Electric
Cap: 50 gallonsEF:
8. Floor Types (2074.0 sqft.) Insulation Area
0.970
a. Slab -On -Grade Edge Insulation R=0.0 2051.00 ftz
b. Conservation features
b. Crawlspace R=19.0 23.00 ftz
None
c. N/A R= ftz
15. Credits
Pstat
Glass/Floor Area: 0.110 Total Proposed Modified Loads: 89.21
PASS
Total Baseline Loads: 113.42
I hereby certify that the plans and specifications covered by
Review of the plans and
04ZAE S7,
this calculation are in compliance with the Florida Energy
specifications covered by this
_ ; �O
Code.
calculation indicates compliance
�'�
with the Florida Energy Code.
rarr' .�. •;; �• .•;,,„ O
PREPARED Y:
Before construction is completed
c
DATE:
this building will be inspected for
-
O ^I,J' ;a
compliance with Section 553.908
*
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
G'Op W IE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
��ile Copy
10/5/2017 11:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 7
FORM R405-2014
PROJECT
Title:
FRIEDRICH RESIDENCE
Bedrooms: . 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2919
Lot #
Owner:
RICHARD & NICOLE FRIED
Total Stories: 2
Block/SubDivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
260 MARINA DRIVE
Permit Office:
ST. LUCIE COUNTY
Cross Ventilation: No
County:
ST. LUCIE COUNTY
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
IECC Design Temp
Int Design Temp
Heating
Design Daily Temp
v Design Location
TMY Site
Zone 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, West Palm Beach FL_WEST_PALM_BEAC 2 44
90
70
75
316
60
Medium
BLOCKS
Number
Name
Area
Volume
1
AHU 1
2052
26709
2
AHU 2
867
6936
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
KITCHEN/LIVING
966
15456 Yes
4
1
Yes
Yes
Yes
2
OFFICE
144
2153 No
0
1
Yes
Yes
Yes
3
1/2 BATH
52
468 No
0
1
Yes
Yes
Yes
4
VAULT
36
360 No
0
1
Yes
Yes
Yes
5
PANTRY
36
360 No
0
1
No
Yes
Yes
6
MASTER BEDROO
341
3410 No
2
1
1
Yes
Yes
Yes
7
WIC 2
45
450 No
0
1
No
Yes
Yes
8
WIC
54
540 No
0
1
Yes
Yes
Yes
9
MASTER BATH
176
1584 No
0
1
Yes
Yes
Yes
10
LAUNDRY
99
891 No
0
1
No
Yes
Yes
11
STAIRS
69
690 No
0
1
No
Yes
Yes
12
STORAGE
34
340 No
0
1
Yes
Yes
Yes
13
BEDROOM 3
144
1152 No
2
1
1
Yes
Yes
Yes
14
BEDROOM 4
121
968 No
2
1
1
Yes
Yes
Yes
15
CLST.3
25
200 No
0
1
Yes
Yes
Yes
16
BATH 2
64
512 No
0
1
Yes
Yes
Yes
17
SITTING
156
1248 No
2
1
Yes
Yes
Yes
18
BEDROOM 2
121
968 No
2
1
1
Yes
Yes
Yes
19
CLST.2
24
192 No
0
1
Yes
Yes
Yes
20
STAIR
173
1384 No
0
1
Yes
Yes
Yes
21
CLST.4
24
192 No
0
1
Yes
Yes
Yes
10/5/2017 11:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 7
FORM R405-2014
SPACES
Number Name
Area Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
I22
A/C
15 120
No
0
1 No
Yes
Yes
I
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulatio
KITCHEN/LIVING
73 ft
0
965.5 ft2
----
0
1
0
2 Slab -On -Grade Edge Insulatio
OFFICE
25.9 ft
0
143.5 ft2
----
0
1
0
3 Slab -On -Grade Edge Insulatio
1/2 BATH
4 ft
0
52 ft2
----
0
1
0
4 Slab -On -Grade Edge Insulatio
VAULT
3 ft
0
36 ft2
----
0
1
0
5 Slab -On -Grade Edge Insulatio
PANTRY
1 ft
0
36 ft2
----
0
1
0
6 Slab -On -Grade Edge Insulatio
MASTER BEDRO
36 ft
0
341 ft2
----
0
1
0
7 Slab -On -Grade Edge Insulatio
WIC 2
1 ft
0
45 ft2
----
0
1
0
8 Slab -On -Grade Edge Insulatio
WIC
9 ft
0
54 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio
MASTER BATH
11 ft
0
176 ft2
- — -
0
1
0
10Slab-On-Grade Edge Insulatio
LAUNDRY
1 ft
0
99 ft2
----
0
1
0
11SIab-On-Grade Edge Insulatio
STAIRS
1 ft
0
69 ft2
----
0
1
0
12SIab-On-Grade Edge Insulatio
STORAGE
14 ft
0
34 ft2
----
0
1
0
13Crawlspace
SITTING
1.9 ft
0
12 ft2
19
0
0
1
14Crawlspace
BEDROOM 2
2 ft
0
11 ft2
19
0
0
1
ROOF
V
Roof Gable
Roof
Solar
SA Emitt
Emitt
Deck
Pitch
# Type Materials
Area Area
Color
Absor.
Tested
Tested Insul.
(deg)
1 Hip
Metal 2162 ft2 0 ft2
Light
0.6
No 0.9
No
20
18.4
ATTIC
V
# Type
Ventilation
Vent Ratio (1
in)
Area
RBS IRCC
1 Full attic
Unvented
0
2051 ft2
N N
10/5/2017 11:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 7
FORM R405-2014
CEILING
77-
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) KITCHEN/LIVING
20
Blown
927 ft2
0.1
Wood
2
Under Attic (Unvented) OFFICE
20
Blown
144 ft2
0.1
Wood
3
Under Attic (Unvented) 1/2 BATH
20
Blown
52 ft2
0.1
Wood
4
Under Attic (Unvented) VAULT
20
Blown
12 ftz
0.1.
Wood
5
Under Attic (Unvented) PANTRY
20
Blown
8 ft2
0.1
Wood
6
Under Attic (Unvented) MASTER BEDRO
20
Blown
7 ft2
0.1
Wood
7
Under Attic (Unvented) LAUNDRY
20
Blown
22 ft2
0.1
Wood
8
Under Attic (Unvented) STAIRS
20
Blown
14 ft2
0.1
Wood
9
Under Attic (Unvented) STORAGE
20
Blown
22 ft2
0.1
Wood
10
Under Attic (Unvented) BEDROOM 3
20
Blown
144 ft2
0.1
Wood
11
Under Attic (Unvented) BEDROOM 4
20
Blown
121 ft2
0.1
Wood
12
Under Attic (Unvented) CLST. 3
20
Blown
25 ft2
0.1
Wood
13
Under Attic (Unvented) BATH 2
20
Blown
64 ft2
0.1
Wood
14
Under Attic (Unvented) SITTING
20
Blown
156 ft2
0.1
Wood
15
Under Attic (Unvented) BEDROOM 2
20
Blown
121 ft2
0.1
Wood
16
Under Attic (Unvented) CLST. 2
20
Blown
24 ft2
0.1
Wood
17
Under Attic (Unvented) STAIR
20
Blown
173 ft2
0.1
Wood
18
Under Attic (Unvented) CLST. 4
20
Blown
24 ft2
0.1
Wood
19
Under Attic (Unvented) A/C
20
Blown
15 ft2
0.1
Wood
WALLS
Adjacent Space Cavity
10 1AInli Type1
Width
Height
Sheathing Framing Solar
Below
N
Exterior Concrete Block - Int InsKITCHEN/LIV
9
36
0 16
0
576.0 ft2
0
0
0.5
0
2
S
Exterior Concrete Block - Int InsKITCHEN/LIV
9
19
0 16
0
304.0 ft2
0
0
0.5
0
3
W
Exterior Concrete Block - Int InsKITCHEN/LIV
9
18
0 16
0
288.0 ft2
0
0
0.5
0
4
S
Exterior Concrete Block - Int Insul OFFICE
9
13
0 15
0
195.0 ft2
0
0
0.5
0
5
W
Exterior Concrete Block - Int Insul OFFICE
9
13
0 15
0
195.0 ft2
0
0
0.5
0
6
S
Exterior Concrete Block - Int Insult/2 BATH
9
4
0 9
0
36.0 ft2
0
0
0.5
0
7
W
Exterior Concrete Block - Int Insul VAULT
9
3
0 10
0
30.0 ft2
0
0
0.5
0
8
N
Exterior Concrete Block - Int InsMASTER BE
9
19
0 10
0
190.0 ft2
0
0
0.5
0
9
E
Exterior Concrete Block - Int InsMASTER BE
9
17
0 10
0
170.0 ft2
0
0
0.5
0
10
E
Exterior Concrete Block - Int Insul WIC
9
9
0 10
0
90.0 ft2
0
0
0.5
0
_ 11
E
Exterior Concrete Block - Int InsiMASTER BA
9
11
0 9
0
99.0 ft2
0
0
0.5
0
_ 12
N
Exterior Concrete Block - Int InsuBTORAGE
9
6
0 10
0
60.0 ft2
0
0
0.5
0
13
E
Exterior Concrete Block - Int InsuBTORAGE
9
2
0 10
0
20.0 ft2
0
0
0.5
0
14
W
Exterior Concrete Block - Int InsuSTORAGE
9
6
0 10
0
60.0 ft2
0
0
0.5
0
15
N
Exterior Concrete Block - Int InsBEDROOM 3
9
12
0 8
0
96.0 ft2
0
0
0.5
0
16
E
Exterior Concrete Block - Int InsBEDROOM 3
9
12
0 8
0
96.0 ft2
0
0
0.5
0
17
W
Exterior Concrete Block - Int InsBEDROOM 3
9
1
0 8
0
8.0 ft2
0
0
0.5
0
18
N
Exterior Concrete Block - Int InsBEDROOM 4
9
11
0 8
0
88.0 ft2
0
0
0.5
0
_ 19
W
Exterior Concrete Block - Int InsBEDROOM 4
9
11
0 8
0
88.0 ft2
0
0
0.5
0
_20
E
Exterior Concrete Block - Int Insul CLST. 3
9
5
0 8
0
40.0 ft2
0
0
0.5
0
_21
E
Exterior Concrete Block - Int Insul BATH 2
9
8
0 8
0
64.0 ft2
0
0
0.5
0
10/5/2017 11:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 7
I
I
FORM R405-2014
i
WALLS
Adjacent
CavR_Vaity
Width
Height
Sheathing Framing
Solar
Below
pace
S1,
le
Et
In
Et In
Area
R Alaille
-tonn
Erne,
AhSor
Gratle%
22
E
Exterior
Concrete Block - Int Insul SITTING
9
13
0
8 0
104.0 ft2
0
0
0.5
0
23
S
Exterior
Concrete Block - Int Insul SITTING
9
12
0
8 0
96.0 ft2
0
0
0.5
0
24
S
Exterior
Concrete Block - Int InsBEDROOM 2
9
11
0
8 0
88.0 ft2
0
0
0.5
0
25
W
Exterior
Concrete Block - Int InsBEDROOM 2
9
11
0
8 0
88.0 ft2
0
0
0.5
0
26
W
Exterior
Concrete Block - Int Insul CLST. 2
9
4
0
8 0
32.0 ft2
0
0
0.5
0
27
W
Exterior
Concrete Block - Int Insul STAIR
9
7
0
8 0
56.0 ft2
0
0
0.5
0
28
N
Exterior
Concrete Block - Int Insul CLST. 4
9
1
0
8 0
8.0 ft2
0
0
0.5
0
_29
S
Exterior
Concrete Block - Int Insul CLST. 4
9
1
0
8 0
8.0 ft2
0
0
0.5
0
_30
W
Exterior
Concrete Block - Int Insul CLST. 4
9
4
0
8 0
32.0 ft2
0
0
0.5
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated KITCHEN/LIV
None
.39
3
8
24 ft2
2
N
Insulated STORAGE
None
.39
3
8
24 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Area
Depth
Separation
Int Shade
Screening
1
N
1
Vinyl Low-E Double Yes
0.35
0.2
96.0 ft2
10 ft 0 in
1 ft 4 in
None
None
2
N
1
Vinyl Low-E Double Yes
0.33
0.21
24.0 ft2
10 ft 0 in
1 ft 4 in
None
None
3
S
2
Vinyl Low-E Double Yes
0.32
0.22
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
4
S
2
Vinyl Low-E Double Yes
0.32
0.22
16.0 ft2
6 ft 0 in
1 ft 4 in
None
None
5
W
3
Vinyl Low-E Double Yes
0.29
0.23
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
6
S
4
Vinyl Low-E Double Yes
0.32
0.22
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
7
W
5
Vinyl Low-E Double Yes
0.29
0.23
4.0 ft2
10 ft 0 in
1 ft 4 in
None
None
8
N
8
Vinyl Low-E Double Yes
0.32
0.22
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
9
E
9
Vinyl Low-E Double Yes
0.29
0.23
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
10
E
11
Vinyl Low-E Double Yes
0.32
0.22
9.0 ft2
2 ft 0 in
1 ft 4 in
None
None
11
N
15
Vinyl Low-E Double Yes
0.32
0.22
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
12
E
16
Vinyl Low-E Double Yes
0.29
0.23
4.0 ft2
2 ft 0 in
1 ft 4 in
None
None
13
N
18
Vinyl Low-E Double Yes
0.32
0.22
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
14
W
19
Vinyl Low-E Double Yes
0.29
0.23
4.0 ft2
2 ft 0 in
1 ft 4 in
None
None
15
E
21-
Vinyl Low-E Double Yes
0.32
0.22
6.0 ft2
2 ft 0 in
1 ft 4 in
None
None
16
E
22
Vinyl Low-E Double Yes
0.29
0.23
4.0 ft2
2 ft 0 in
1 ft 4 in
None
None
17
S
23
Vinyl Low-E Double Yes
0.32
0.22
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
18
S
24
Vinyl Low-E Double Yes
0.32
0.22
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
19
W
25
Vinyl Low-E Double Yes
0.32
0.22
4.0 ft2
2 ft 0 in
1 ft 4 in
None
None
10/5/2017 11:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 7
i
FORM R405-2014
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
513.6ft2
513.6ft2
24ft loft 4.1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000513
3924.4 215.45 405.18 .4354 7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
2
Electric Strip Heat
Electric Strip Heat
None
None
COP:1 27 kBtu/hr 1
COP:1 17 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit
Central Unit
Split
Split
SEER: 16.5 36 kBtu/hr cfm 0.8 1
SEER: 16 17.6 kBtu/hr cfm 0.8 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.97 50 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume FEF
None
None
ft2
DUCTS
/
#
--- Supply —
Location R-Value Area
--- Return -- Air CFM 25 CFM25 HVAC #
Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1
2
Attic 6 425 ft2
Attic 6 225 ft2
Attic
Attic
105 ft2 Default Leakage LAUNDRY (Default) (Default)
55 ft2 Default Leakage A/C (Default) (Default)
1 1
2 2
10/5/2017 11:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 7
i
FORM RAnr,-gf11A
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
HeatinHJan
Feb
HFeb
Mar
Mar
f
Apr
Apr
Ma
May
X Jun
Jun
Jul
Jul
ri
Xj AugX]
4 ] Au[
]
Se [
Sep [
] Oct
] Oct
Nov
X Nov
Dec
Dec
Ventin Jan
Feb
X Mar
[X
A r
Ma
Jun
Jul
[ ] Aug
[ j
Se [X]
Oct
[X Nov
Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
10/5/2017 11:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 7 of 7
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: FRIEDRICH RESIDENCE Builder Name:
Street: 260 MARINA DRIVE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: RICHARD & NICOLE FRIEDRICH Jurisdiction:
Design Location: FL, West Palm Beach
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/doorjambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
10/5/2017 11:35 AM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 79
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz)
7. Windows- Description
a. U-Factor: Dbl, U=0.32
SHGC: SHGC=0.22
b. U-Factor: Dbl, U=0.35
SHGC: SHGC=0.20
c. U-Factor: Dbl, U=0.29
SHGC: SHGC=0.23
d. U-Factor: other (see details)
SHGC: other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
260 MARINA DRIVE, FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Single-family
a. Concrete Block - Int Insul, Exterior
b. N/A
1
c. N/A
4
d. N/A
10. Ceiling Types
No
a. Roof Deck (Unvented)
2919
b. N/A
Area
c. N/A
160.00 ftz
11. Ducts
a. Sup: Attic, Ret: Attic, AH: LAUNDRY
b. Sup: Attic, Ret: Attic, AH: A/C
96.00 ftz
12. Cooling systems
40.00 ftz
a. Central Unit
b. Central Unit
8. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. Crawispace R=19.0
c. N/A R=
24.00 ftz
13. Heating systems
a. Electric Strip Heat
5.300 ft.
b. Electric Strip Heat
0.214
Area
14. Hot water systems
2051.00 ftz
a. Electric
23.00 ftz
ftz
b. Conservation features
None
15. Credits
certify that this home has complied with the Florida Energy Efficiency Code for Building
construction through the above energy saving features which will be installed (or exceeded)
n this home before final inspection. Otherwise, a new EPL Display Card will be completed
>ased on installed Code compliant features.
ilder Signature:
of New Home:
Date:
City/FL Zip:
Insulation Area
R=9.0 3305.00 ftz
R=
ftZ
R=
ftZ
R=
ftZ
Insulation
Area
R=20.0
2075.00 ftz
R=
ftz
R=
ftz
R ftz
6 425
6 225
kBtu/hr Efficiency
36.0 SEER:16.50
17.6 SEER:16.00
kBtu/hr Efficiency
27.0 COP:1.00
17.0 COP:1.00
Cap: 50 gallons
EF: 0.97
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.