HomeMy WebLinkAboutEnergy Efficiency Coder FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: FRIEDRICH RESIDENCE Builder Name: Street: 260 MARINA DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL , Permit Number: Owner: RICHARD & NICOLE FRIEDRICH Jurisdiction: Design Location: FL, West Palm Beach County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (3305.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=9.0 3305.00 ftz b. N/A R= ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 4 d. N/A R= ftz 5. Is this a worst case? No 10. Ceiling Types (2075.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2075.00 ftZ 6. Conditioned floor area above grade (ft2) 2919 b. N/A R= ftZ Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 11. Ducts R ftz 7. Windows(320.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: LAUNDRY 6 425 a. U-Factor: Dbl, U=0.32 160.00 ftz b. Sup: Attic, Ret: Attic, AH: A/C 6 225 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.35 96.00 ftz 12. Cooling systems kBtu/hr Efficiency • SHGC: SHGC=0.20 a. Central Unit 36.0 SEER:16.50 b. Central Unit 17.6 SEER:16.00 c. U-Factor: Dbl, U=0.29 40.00 ftz SHGC: SHGC=0.23 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 24.00 ftz a. Electric Strip Heat 27.0 COP:1.00 SHGC: other (see details) b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 5.300 ft. Area Weighted Average SHGC: 0.214 14. Hot water systems a. Electric Cap: 50 gallonsEF: 8. Floor Types (2074.0 sqft.) Insulation Area 0.970 a. Slab -On -Grade Edge Insulation R=0.0 2051.00 ftz b. Conservation features b. Crawlspace R=19.0 23.00 ftz None c. N/A R= ftz 15. Credits Pstat Glass/Floor Area: 0.110 Total Proposed Modified Loads: 89.21 PASS Total Baseline Loads: 113.42 I hereby certify that the plans and specifications covered by Review of the plans and 04ZAE S7, this calculation are in compliance with the Florida Energy specifications covered by this _ ; �O Code. calculation indicates compliance �'� with the Florida Energy Code. rarr' .�. •;; �• .•;,,„ O PREPARED Y: Before construction is completed c DATE: this building will be inspected for - O ^I,J' ;a compliance with Section 553.908 * I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'Op W IE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. ��ile Copy 10/5/2017 11:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 7 FORM R405-2014 PROJECT Title: FRIEDRICH RESIDENCE Bedrooms: . 4 Address Type: Street Address Building Type: User Conditioned Area: 2919 Lot # Owner: RICHARD & NICOLE FRIED Total Stories: 2 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 260 MARINA DRIVE Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, West Palm Beach FL_WEST_PALM_BEAC 2 44 90 70 75 316 60 Medium BLOCKS Number Name Area Volume 1 AHU 1 2052 26709 2 AHU 2 867 6936 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 KITCHEN/LIVING 966 15456 Yes 4 1 Yes Yes Yes 2 OFFICE 144 2153 No 0 1 Yes Yes Yes 3 1/2 BATH 52 468 No 0 1 Yes Yes Yes 4 VAULT 36 360 No 0 1 Yes Yes Yes 5 PANTRY 36 360 No 0 1 No Yes Yes 6 MASTER BEDROO 341 3410 No 2 1 1 Yes Yes Yes 7 WIC 2 45 450 No 0 1 No Yes Yes 8 WIC 54 540 No 0 1 Yes Yes Yes 9 MASTER BATH 176 1584 No 0 1 Yes Yes Yes 10 LAUNDRY 99 891 No 0 1 No Yes Yes 11 STAIRS 69 690 No 0 1 No Yes Yes 12 STORAGE 34 340 No 0 1 Yes Yes Yes 13 BEDROOM 3 144 1152 No 2 1 1 Yes Yes Yes 14 BEDROOM 4 121 968 No 2 1 1 Yes Yes Yes 15 CLST.3 25 200 No 0 1 Yes Yes Yes 16 BATH 2 64 512 No 0 1 Yes Yes Yes 17 SITTING 156 1248 No 2 1 Yes Yes Yes 18 BEDROOM 2 121 968 No 2 1 1 Yes Yes Yes 19 CLST.2 24 192 No 0 1 Yes Yes Yes 20 STAIR 173 1384 No 0 1 Yes Yes Yes 21 CLST.4 24 192 No 0 1 Yes Yes Yes 10/5/2017 11:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 7 FORM R405-2014 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated I22 A/C 15 120 No 0 1 No Yes Yes I FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio KITCHEN/LIVING 73 ft 0 965.5 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio OFFICE 25.9 ft 0 143.5 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio 1/2 BATH 4 ft 0 52 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio VAULT 3 ft 0 36 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio PANTRY 1 ft 0 36 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulatio MASTER BEDRO 36 ft 0 341 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio WIC 2 1 ft 0 45 ft2 ---- 0 1 0 8 Slab -On -Grade Edge Insulatio WIC 9 ft 0 54 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio MASTER BATH 11 ft 0 176 ft2 - — - 0 1 0 10Slab-On-Grade Edge Insulatio LAUNDRY 1 ft 0 99 ft2 ---- 0 1 0 11SIab-On-Grade Edge Insulatio STAIRS 1 ft 0 69 ft2 ---- 0 1 0 12SIab-On-Grade Edge Insulatio STORAGE 14 ft 0 34 ft2 ---- 0 1 0 13Crawlspace SITTING 1.9 ft 0 12 ft2 19 0 0 1 14Crawlspace BEDROOM 2 2 ft 0 11 ft2 19 0 0 1 ROOF V Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2162 ft2 0 ft2 Light 0.6 No 0.9 No 20 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2051 ft2 N N 10/5/2017 11:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 7 FORM R405-2014 CEILING 77- # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) KITCHEN/LIVING 20 Blown 927 ft2 0.1 Wood 2 Under Attic (Unvented) OFFICE 20 Blown 144 ft2 0.1 Wood 3 Under Attic (Unvented) 1/2 BATH 20 Blown 52 ft2 0.1 Wood 4 Under Attic (Unvented) VAULT 20 Blown 12 ftz 0.1. Wood 5 Under Attic (Unvented) PANTRY 20 Blown 8 ft2 0.1 Wood 6 Under Attic (Unvented) MASTER BEDRO 20 Blown 7 ft2 0.1 Wood 7 Under Attic (Unvented) LAUNDRY 20 Blown 22 ft2 0.1 Wood 8 Under Attic (Unvented) STAIRS 20 Blown 14 ft2 0.1 Wood 9 Under Attic (Unvented) STORAGE 20 Blown 22 ft2 0.1 Wood 10 Under Attic (Unvented) BEDROOM 3 20 Blown 144 ft2 0.1 Wood 11 Under Attic (Unvented) BEDROOM 4 20 Blown 121 ft2 0.1 Wood 12 Under Attic (Unvented) CLST. 3 20 Blown 25 ft2 0.1 Wood 13 Under Attic (Unvented) BATH 2 20 Blown 64 ft2 0.1 Wood 14 Under Attic (Unvented) SITTING 20 Blown 156 ft2 0.1 Wood 15 Under Attic (Unvented) BEDROOM 2 20 Blown 121 ft2 0.1 Wood 16 Under Attic (Unvented) CLST. 2 20 Blown 24 ft2 0.1 Wood 17 Under Attic (Unvented) STAIR 20 Blown 173 ft2 0.1 Wood 18 Under Attic (Unvented) CLST. 4 20 Blown 24 ft2 0.1 Wood 19 Under Attic (Unvented) A/C 20 Blown 15 ft2 0.1 Wood WALLS Adjacent Space Cavity 10 1AInli Type1 Width Height Sheathing Framing Solar Below N Exterior Concrete Block - Int InsKITCHEN/LIV 9 36 0 16 0 576.0 ft2 0 0 0.5 0 2 S Exterior Concrete Block - Int InsKITCHEN/LIV 9 19 0 16 0 304.0 ft2 0 0 0.5 0 3 W Exterior Concrete Block - Int InsKITCHEN/LIV 9 18 0 16 0 288.0 ft2 0 0 0.5 0 4 S Exterior Concrete Block - Int Insul OFFICE 9 13 0 15 0 195.0 ft2 0 0 0.5 0 5 W Exterior Concrete Block - Int Insul OFFICE 9 13 0 15 0 195.0 ft2 0 0 0.5 0 6 S Exterior Concrete Block - Int Insult/2 BATH 9 4 0 9 0 36.0 ft2 0 0 0.5 0 7 W Exterior Concrete Block - Int Insul VAULT 9 3 0 10 0 30.0 ft2 0 0 0.5 0 8 N Exterior Concrete Block - Int InsMASTER BE 9 19 0 10 0 190.0 ft2 0 0 0.5 0 9 E Exterior Concrete Block - Int InsMASTER BE 9 17 0 10 0 170.0 ft2 0 0 0.5 0 10 E Exterior Concrete Block - Int Insul WIC 9 9 0 10 0 90.0 ft2 0 0 0.5 0 _ 11 E Exterior Concrete Block - Int InsiMASTER BA 9 11 0 9 0 99.0 ft2 0 0 0.5 0 _ 12 N Exterior Concrete Block - Int InsuBTORAGE 9 6 0 10 0 60.0 ft2 0 0 0.5 0 13 E Exterior Concrete Block - Int InsuBTORAGE 9 2 0 10 0 20.0 ft2 0 0 0.5 0 14 W Exterior Concrete Block - Int InsuSTORAGE 9 6 0 10 0 60.0 ft2 0 0 0.5 0 15 N Exterior Concrete Block - Int InsBEDROOM 3 9 12 0 8 0 96.0 ft2 0 0 0.5 0 16 E Exterior Concrete Block - Int InsBEDROOM 3 9 12 0 8 0 96.0 ft2 0 0 0.5 0 17 W Exterior Concrete Block - Int InsBEDROOM 3 9 1 0 8 0 8.0 ft2 0 0 0.5 0 18 N Exterior Concrete Block - Int InsBEDROOM 4 9 11 0 8 0 88.0 ft2 0 0 0.5 0 _ 19 W Exterior Concrete Block - Int InsBEDROOM 4 9 11 0 8 0 88.0 ft2 0 0 0.5 0 _20 E Exterior Concrete Block - Int Insul CLST. 3 9 5 0 8 0 40.0 ft2 0 0 0.5 0 _21 E Exterior Concrete Block - Int Insul BATH 2 9 8 0 8 0 64.0 ft2 0 0 0.5 0 10/5/2017 11:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 7 I I FORM R405-2014 i WALLS Adjacent CavR_Vaity Width Height Sheathing Framing Solar Below pace S1, le Et In Et In Area R Alaille -tonn Erne, AhSor Gratle% 22 E Exterior Concrete Block - Int Insul SITTING 9 13 0 8 0 104.0 ft2 0 0 0.5 0 23 S Exterior Concrete Block - Int Insul SITTING 9 12 0 8 0 96.0 ft2 0 0 0.5 0 24 S Exterior Concrete Block - Int InsBEDROOM 2 9 11 0 8 0 88.0 ft2 0 0 0.5 0 25 W Exterior Concrete Block - Int InsBEDROOM 2 9 11 0 8 0 88.0 ft2 0 0 0.5 0 26 W Exterior Concrete Block - Int Insul CLST. 2 9 4 0 8 0 32.0 ft2 0 0 0.5 0 27 W Exterior Concrete Block - Int Insul STAIR 9 7 0 8 0 56.0 ft2 0 0 0.5 0 28 N Exterior Concrete Block - Int Insul CLST. 4 9 1 0 8 0 8.0 ft2 0 0 0.5 0 _29 S Exterior Concrete Block - Int Insul CLST. 4 9 1 0 8 0 8.0 ft2 0 0 0.5 0 _30 W Exterior Concrete Block - Int Insul CLST. 4 9 4 0 8 0 32.0 ft2 0 0 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated KITCHEN/LIV None .39 3 8 24 ft2 2 N Insulated STORAGE None .39 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.35 0.2 96.0 ft2 10 ft 0 in 1 ft 4 in None None 2 N 1 Vinyl Low-E Double Yes 0.33 0.21 24.0 ft2 10 ft 0 in 1 ft 4 in None None 3 S 2 Vinyl Low-E Double Yes 0.32 0.22 20.0 ft2 2 ft 0 in 1 ft 4 in None None 4 S 2 Vinyl Low-E Double Yes 0.32 0.22 16.0 ft2 6 ft 0 in 1 ft 4 in None None 5 W 3 Vinyl Low-E Double Yes 0.29 0.23 12.0 ft2 2 ft 0 in 1 ft 4 in None None 6 S 4 Vinyl Low-E Double Yes 0.32 0.22 15.0 ft2 2 ft 0 in 1 ft 4 in None None 7 W 5 Vinyl Low-E Double Yes 0.29 0.23 4.0 ft2 10 ft 0 in 1 ft 4 in None None 8 N 8 Vinyl Low-E Double Yes 0.32 0.22 30.0 ft2 2 ft 0 in 1 ft 4 in None None 9 E 9 Vinyl Low-E Double Yes 0.29 0.23 12.0 ft2 2 ft 0 in 1 ft 4 in None None 10 E 11 Vinyl Low-E Double Yes 0.32 0.22 9.0 ft2 2 ft 0 in 1 ft 4 in None None 11 N 15 Vinyl Low-E Double Yes 0.32 0.22 15.0 ft2 2 ft 0 in 1 ft 4 in None None 12 E 16 Vinyl Low-E Double Yes 0.29 0.23 4.0 ft2 2 ft 0 in 1 ft 4 in None None 13 N 18 Vinyl Low-E Double Yes 0.32 0.22 15.0 ft2 2 ft 0 in 1 ft 4 in None None 14 W 19 Vinyl Low-E Double Yes 0.29 0.23 4.0 ft2 2 ft 0 in 1 ft 4 in None None 15 E 21- Vinyl Low-E Double Yes 0.32 0.22 6.0 ft2 2 ft 0 in 1 ft 4 in None None 16 E 22 Vinyl Low-E Double Yes 0.29 0.23 4.0 ft2 2 ft 0 in 1 ft 4 in None None 17 S 23 Vinyl Low-E Double Yes 0.32 0.22 15.0 ft2 2 ft 0 in 1 ft 4 in None None 18 S 24 Vinyl Low-E Double Yes 0.32 0.22 15.0 ft2 2 ft 0 in 1 ft 4 in None None 19 W 25 Vinyl Low-E Double Yes 0.32 0.22 4.0 ft2 2 ft 0 in 1 ft 4 in None None 10/5/2017 11:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 7 i FORM R405-2014 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 513.6ft2 513.6ft2 24ft loft 4.1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000513 3924.4 215.45 405.18 .4354 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Strip Heat Electric Strip Heat None None COP:1 27 kBtu/hr 1 COP:1 17 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit Central Unit Split Split SEER: 16.5 36 kBtu/hr cfm 0.8 1 SEER: 16 17.6 kBtu/hr cfm 0.8 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / # --- Supply — Location R-Value Area --- Return -- Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 2 Attic 6 425 ft2 Attic 6 225 ft2 Attic Attic 105 ft2 Default Leakage LAUNDRY (Default) (Default) 55 ft2 Default Leakage A/C (Default) (Default) 1 1 2 2 10/5/2017 11:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 7 i FORM RAnr,-gf11A TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan HeatinHJan Feb HFeb Mar Mar f Apr Apr Ma May X Jun Jun Jul Jul ri Xj AugX] 4 ] Au[ ] Se [ Sep [ ] Oct ] Oct Nov X Nov Dec Dec Ventin Jan Feb X Mar [X A r Ma Jun Jul [ ] Aug [ j Se [X] Oct [X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 10/5/2017 11:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 7 of 7 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: FRIEDRICH RESIDENCE Builder Name: Street: 260 MARINA DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: RICHARD & NICOLE FRIEDRICH Jurisdiction: Design Location: FL, West Palm Beach COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 10/5/2017 11:35 AM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 79 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftz) 7. Windows- Description a. U-Factor: Dbl, U=0.32 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.35 SHGC: SHGC=0.20 c. U-Factor: Dbl, U=0.29 SHGC: SHGC=0.23 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 260 MARINA DRIVE, FT. PIERCE, FL, New (From Plans) 9. Wall Types Single-family a. Concrete Block - Int Insul, Exterior b. N/A 1 c. N/A 4 d. N/A 10. Ceiling Types No a. Roof Deck (Unvented) 2919 b. N/A Area c. N/A 160.00 ftz 11. Ducts a. Sup: Attic, Ret: Attic, AH: LAUNDRY b. Sup: Attic, Ret: Attic, AH: A/C 96.00 ftz 12. Cooling systems 40.00 ftz a. Central Unit b. Central Unit 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. Crawispace R=19.0 c. N/A R= 24.00 ftz 13. Heating systems a. Electric Strip Heat 5.300 ft. b. Electric Strip Heat 0.214 Area 14. Hot water systems 2051.00 ftz a. Electric 23.00 ftz ftz b. Conservation features None 15. Credits certify that this home has complied with the Florida Energy Efficiency Code for Building construction through the above energy saving features which will be installed (or exceeded) n this home before final inspection. Otherwise, a new EPL Display Card will be completed >ased on installed Code compliant features. ilder Signature: of New Home: Date: City/FL Zip: Insulation Area R=9.0 3305.00 ftz R= ftZ R= ftZ R= ftZ Insulation Area R=20.0 2075.00 ftz R= ftz R= ftz R ftz 6 425 6 225 kBtu/hr Efficiency 36.0 SEER:16.50 17.6 SEER:16.00 kBtu/hr Efficiency 27.0 COP:1.00 17.0 COP:1.00 Cap: 50 gallons EF: 0.97 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/5/2017 11:35 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 a r