Loading...
HomeMy WebLinkAboutPool Plans-- —- ?✓% -- -- —� -- -- —F�— —- -— —— -- — --- POOL 5PE05: SIZE: 14' X 2b' I DEPTH: 3' TO 5' PERIMETER: 84 AREA: 3Q2 VOLUME: 11,72q I TURNOVER: 6 HR. MIN, (25 GPM ® LOW SPEED) DOPING: SQUARE EDGE TRAVERTINE TILE. 6" SKIMMER: I I RETURN5.3 VAC LINE: YES LIGHT: 2-20W JANDY NITCHELESS L.E.D. SWIMOUT: 16' X 48' I FINISH: QUARTZSCAPES RAILINGS: NO PATIO: BRICK PAVERS ENGLOSUE: YES I FOOTERS: YES DECK-O-DRAIN: AS NEEDED SUNSFELF/IST STEP WITH TILED EDGE I I E OVERHEAD ELECTRIC LINE I "r I W I v I v Q JOB SITE SPECIFICATIONS &06 5 MILITARY TRAIL LOT: 681 BLOCK: 150 s DEERFIELD BEACH, FL 33442 SUBDIVISION: LAKEWOOD PARK UNIT It PHONE: C154-631-0101 PLAT BOOK: 32 PAGE: 32-A -3212 I COUNTY: ST LUCIE lo' PU.D.E. RECEIV7D AUG 0 3' `fU N SEE PIPING SCHEMATIC FOR DETAILS AND SIZES POOL EQUIP 22' 4 r----=--------------I III }--� --- ==—JI I 4 I I I I I I � I SUNSHELF/IST ' STEP WITH TILED EDGE I I EXISTING COVERED PATIO RESIDENCE 5WIMMING POOL PLAN FOR. SKIM' I IN 5'DP Z m` / I r I' a I N VAC t l 1 I?14' WIDE l NL j f` INL JOOY POLLANO 7100 5ABA3TIAN ROAD FORT PIERCE, FLORIOA 34g51 DRAWING ITEMS � REVISIONS: DATE: 1-12-11 ORDER a 441 DRAWN BY: NAS. PLAN # 110101-21 SHEET: 1 OF 5 File Copy CONCEALED FAS ► E► ERS OR A7dCHM—tii i i3 ARE THE RESPONSIBILITY OF TEE TCA SRO THESE PLANS ANTt°. 'ALL PROPOSED WORK BEOSCREE ED IF EODL {5Af1E�Iy�yEQqT f Q [d CORRECTIONS BY LOCAL CODE REQUIPHE 1g`T MELD INISPEQTgQ�IR`it`��piHA ff, Roll PUMP: FHPM IA tP JANDY FLOPRO 2 SPEED FILTER: 05-250 DANDY CARTRIDGE 16" X 4b" CHLORINATOR: IN LINE SWIMOUT WITH TILED EDGE HEATER: NO AUTOMATION: NO FOOTING AT EDGE FOR SCREEN ENCL. SEE TYPICAL SECTION ON SHEET 2 OF 3 FOR DETAILS 513MDACOUNTY R-UPULDWG DLVi53®N REWYE- �r(7�i v DATJi' OR NO INSPECTION WILL BE TMADE. PLAN A�WF_� " = I'-O" EIV F• i * o. 57 • �* l/19/2011 :• WAYNE MARKHAM 13ENNETT O•.•. O :. 41 P.E a 51216 / M54) 818-3825265 5. FEDERAL �i � ( ••. �\ �� DEERFIELD BEACH, L 0 33441 ,�S�ONAL••��G�`\ WAYNEOWMB-PE.COM // IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES EXISTING PANEL 112" PVC CONDUIT W/ 2 #10 HOT, 2P 30A BREAKER 1 #10 GRND, 1 a 10 NEUTRAL SQUARE ails copy' FEEDING POOL 2" POOL WASTE EDGE C' FRETAIN ON SITE TRAVERTINE 2 SPEED WATER LEVEL SLOPE EXISTING I/ "=1"-O" METER Q TIME CLOCK WP OF] b' TO m •' I 1-1 il 20' FROM )VALVEYP) u F.P.L. 10"X12" BOND 0 U. WATER 2 #12 POOL PUMP 3 a12, I �12 GRND.NTIWJOUS 4 8" X 8" FTG POOL 46' MIN. 1 #12 —4U911 W. 1 #5 CONT. DECK AND• w #3®10" INTERLOCKING BRICK LEVEL F (I) JUNCTION JANDY (C5250) 250 SFJANDY (FHPMI.0-2) I HP TWO SPEED PUMP Q OGEW PAVERS SET IN SAND BOX 6" ON COMPACTED FILL 3 �k — CARTRIDGE FILTER100 GPM MAX FLOW RATE SELF -PRIMING W. O w APPROVED HAIR AND LINT STRAINER'-j~�I" NON -CORROSIVE ~ APPROVED 5TEELTEX FORM V m 3 CONDUIT ? FINISH OR MASONITE OR L(2) 20W JANDY NITCHELE55 L.E.D. LIGHTS (POOL) �3 WAY VALVE (TYP) RADIUS MIN. I/8" PLYWOOD I W. LOW WATER CUT OFF DEVICES VARIES ELECTRICAL R15ER DIAGRAM IN -LINE TYPICAL WALL SECTION SCALE: NOT TO SCALE CHLORINATOR SCALE: I/4" = I'-O" LL LL a6 LL IQ N 10 to Z POOL 18" < PATIO WATER LEVEL J J IL _Q > (V (V (V fV TILE TOP OR SEE TYPICAL FRONT EDGE WALL SECTION FOR DETAILS POOL 3 WATER LEVEL SWIMOUT SECTION PIPING SCHEMATIC PATIO SCALE: NOT TO SCALE SCALE: 1/4" = 1'-0"n x 3 1 111 IIk� If 1 m w -�( w - z m �- SEE TYPICAL WALL O SECTION FOR DETAILS ti 25' Q d NOTE: STEP STEEL NOT REQUIRED WATERWAY (640-ISXX V SERIES) &" PAT[ 24' 4 PATIO d POOL DRAINS wr APPROVED COVERS WATER LEVEL (ANSI/ASME AI12.19.8-2007ENTRY STEP SEG TION) (TYPICAL) � • ' — _"jjl � - LTE 3 GPM ®2.12 F.P.5. (FLOOR RATE) —II =Ili='�I=1- II[=i11=11�1'' SCALE: 1/4" = 1'-0" SEE PIPING ISOMETRIC III m 10 MAXIMUM POOL a) IIII Q' SEE TYPICAL IN V I=1 w ., FOR PIPE SIZE WALL SECTION 11-11 ` ' SLR DRAIN I 1I- w m z = FOR DETAILS III —III,- I^II�III—III_— tr ' IIIE II —II �= F � =III-1 I I—III—III=1 I I —I I1=1 I I I I 1=1 _- •— w ' ` ` 1=1 I1=1 � ai 8 F.P.S. TO PUMP MAX. d) u• POOL WALL —"'_ -III=ll I L=I C. J SLOPE (TYP) `(HAM ROCK BED ��� �p,R d (SIZE VARIES) �� r- HYDROSTATIC "'�� .•' • E C NS • �/ji // —o DRAIN DETAIL RELIEF VALVE 1 1/2" WELL POINT �, �•'•• i SCALE: 1/4" = 1'-0" •• w LONGITUDINAL SEG TION � �' : o. 5 • w SCALE: NOT TO SCALE - * : •; LL 7/19/2011 i - NAME MARKNAM BENNETT % O ••. <C/ N JOB SITE SPECIFICATIONS SWIMMING POOL PLAN FOR: DRAWING ITEMS REVISIONS: P.E u 51216 / 054) 50-3525 �A•''•F� 0 R I OP•w'\' &Ob 5 MILITARY TRAIL LOT: (787 BLOCK: 150 DATE:1-12-17 DEERFIELD BEAGH265 S. FEDERAL WFL 334�41 �� Vl) •A•••••Vl— �� w s' r F. DEERFIELD BEACH, FL JODY POLLANO ORDER a 441 // //ONA U \\\ ` WAYNE®WMB-PE.GOM / Q • 33442 SUBDIVISION: LAKEwooD PARK UNIT II 7100 5ABASTIAN ROAD DRAWN BY: N.A.S. 't PHONE: C154-631-0107 PLAT BOOK: 32 PAGE: 32-A -320 IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF TH15 DOCUMENT ARE PLAN p 170707-21 FORT PIERCE, FLORIDA 34951 NOT CON51PERED SIGNED AND SEALED AND THE SIGNATURE MUST BE dCOUNTY: 5T LUCIE SHEET: 2 OF 5 VERIFIED ON ANY ELECTRONIC COPIES w w F W IY IL 6 z a r w J IL GOVERNING 600E5 AND GENERAL NOTES FLORIDA BUILDING CODE (FBC). 5TH EDITION (2014) AND ALL OTHER CODES, RULES, REGULATIONS AND RESTRICTIONS HAVING JURISDICTION ON THE PROJECT SHALL GOVERN INCLUDING FBC 5TH EDITION BUILDING, RESIDENTIAL, FUEL GAS AND ENERGY CONSERVATION FBG 5TH EDITION ENERGY CONSERVATION R403A AND WITH AN9I/APSP-14 HAS BEEN MET FOR THIS PROJECT FBC 5TH EDITION ENERGY CONSERVATION C404.1• POOLS AND IN GROUND PERMANENTLY INSTALLED SPAS HAS BEEN MET FOR THI5 PROJECT (EXCEPTION) HEAT PUMP 15 BEING INSTALLED FBC 5TH EDITION RESIDENTIAL CHAPTER 451 SWIMMING POOLS SHALL SPECIFICALLY GOVERN FBC 5TH EDITION R4501b ENGINEERING DESIGN HAS BEEN MET FOR THIS PROJECT, INCLUDING CODES AND REFERENCES SPECIFICALLY WITHIN FBC 5TH EDITION R4501b.1 CONFORMANCE STANDARD. DESIGN, CONSTRUCTION AND WORKMANSHIP SHALL BE IN CONFORMITY WITH THE REQUIREMENTS OF AN51/N5P13-AN51/APSPACX-4-AN51/AP5P/ICG5-AN51/APSP/ICC6- AN51/AP5P 7 CONCRETE: CONCRETE SHALL CONFORM TO THE LATEST EDITION OF ACI 301 AND AGI 31b WITH MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 5.000 P51. POOL CONCRETE CAN BE APPLIED PNEUMATICALLY AND SHALL CONFORM TO ACI-506.2 REINFORCING STEEL: SHALL CONFORM TO THE LATEST EDITION OF ASTM A615, GRADE 60 FBC 5TH EDITION BUILDING 141032 GLASS FIBER REINFORCED CONCRETE GFCR AND THE MATERIALS USED IN SUCH CONCRETE SHALL BE IN ACCORDANCE WITH THE PGI MNL 12b STANDARD IF SHOWN ON THE DRAWIN65 POOL PIPING SHALL BE N.5.F. APPROVED AND SCHEDULE 40. THE ENGINEER IS NOT RESPONSIBLE FOR ANY ENCROACHMENT INTO EASEMENTS OR SETBACKS, EVEN IF APPROVED BY AUTHORITY HAVING JURISDICTION THESE DRAWINGS SHALL NOT BE SCALED,. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE. THESE DRAWINGS ARE THE PROPERTY OF WAYNE MARKHAM BENNETT, P.E. USE OF THESE DRAWINGS WITHOUT PERMISSION FROM THE ENGINEER 15 PROHIBITED AND A VIOLATION OF THE FBC 5TH EDITION USE OF THESE DRAWINGS BY THE CONTRACTOR INDEMNIFIES AND HOLDS HARMLESS THE ENGINEER FOR ALL COSTS AND DAMAGES INCLUDING LEGAL FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION AND CONSTRUCTION PRACTICES BEYOND WHICH 15 GALLED FOR LOCAL, STATE AND FEDERAL CODES AND FROM DEVIATIONS OF THESE PLANS EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED EXISTING CONDITIONS, DIMENSIONS AND QUANTITIES SHALL BE FIELD VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION. TYPICAL FIELD CONDITIONS ARE ASSUMED IN THE DESIGN. SHOULD ANYTHING DIFFER FROM THAT SPECIFIED HEREIN OR STANDARD FIELD CONDITIONS, ADDITIONAL ENGINEERING MAY BE REQUIRED AND THE ENGINEER SHALL BE CONTACTED TO PROVIDE DIRECTION. CARE SHALL BE TAKEN BY CONTRACTOR IN ALL APPLICATION OF THESE DRAWINGS EQUIPMENT AND PIPING PHYSICAL LOCATION MAY DIFFER IN THE FIELD DUE TO UNFORESEEN CONDITIONS OR OTHER FACTORS. CONTRACTOR SHALL BE RESPONSIBLE TO LOCATE AND INSTALL ITEMS IN A LOCATION THAT MEETS LOCAL CODES NDPES REQUIREMENTS: A SILT FENCE SHALL BE INSTALLED PRIOR TO CONSTRUCTION SURROUNDING THE ENTIRE WORK AREA MEETING THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION CONTRACTOR SHALL BE RESPONSIBLE TO SECURE AND PROTECT ALL MATERIAL BROUGHT ON SITE, SHALL RESTORE ALL AREAS IMPACTED BY THE CONSTRUCTION WORK TO THE PREEXISTING CONDITION OR BETTER AND SHALL NOT IMPACT DRAINAGE/LAKE OR ANY OTHER EASEMENTS WITHOUT EASEMENT OWNER CONSENT SWIMMING POOL BARRIER REQUIREMENTS FBC 5TH EDITION RESIDENTIAL R4501,17.1.1 THROUGH R4501,1.17.1.14 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS BARRIER SHALL BE A MINIMUM OF 45 INCHES ABOVE GRADE, WITH A MINIMUM OF 2" CLEARANCE AT BOTTOM. NO GAPS GREAT THAN A 4 INCH SPHERE. ACGE55 GATES SHALL BE SELF CLOSING, WITH SELF LATCHING DEVICE LOCATED A MINIMUM OF 54 INCHES ABOVE GRADE ON THE POOL SIDE AND SWING OUTWARD AWAY FROM THE POOL. ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM THE HOUSE SHALL BE EQUIPPED WITH AN EXIT ALARM COMPLYING WITH UL2107. RESIDENTIAL SWIMMING BARRIER BY SEPARATE PERMIT OWNER RESPONSIBILITY. IT 15 THE RESPONSIBILITY OF THE PROPERTY OWNER TO PROVIDE A SWIMMING BARRIER AROUND THE POOL THAT MEETS THE ABOVE CODE PRIOR TO FINAL POOL STRUCTURAL INSPECTION AND FILLING OF THE POOL, BY SEPARATE PERMIT j 501L BEAR/NCB AND FOUNDATION NOTES FBC 5TH EDITION BUILDING 1&03 GEOTECHNICAL INVESTIGATIONS, THE BUILDING OFFICIAL SHALL BE PERMITTED TO WAIVE THE REQUIREMENT ` WHERE SATISFACTORY DATA FROM ADJACENT AREAS 15 AVAILABLE THAT DEMONSTRATES AN INVESTIGATION 15 NOT NECESSARY AND FBG 5TH EDITION R401.4.1 IN LIEU OF A COMPLETE GEOTECHNICAL EVALUATION, THE LOAD BEARING VALVES IN TABLE R401.4.1 SHALL BE USED, ALLOWABLE BEARING CAPACITY. BASED ON RATIONAL ANALYSIS THROUGH KNOWLEDGE OF OTHER PROJECTS IN THE VICINITY AND A VISUAL EXAMINATION OF THE SURFACE SOIL, FINDING SAND AND ROCK, THE POOL FOUNDATION HAS BEEN DESIGNED ASSUMING A 2000 P5F SOIL BEARING CAPACITY PER FBG 5TH EDITION TABLE R401.4.1 A LETTER REPEATING THE ABOVE CAN BE SUBMITTED TO THE BUILDING OFFICIAL, IF REQUESTED. IF DURING EXCAVATION DELETERIOUS MATERIAL (SUCH AS SILT, PEAT, MUCK, CLAY, ECT) 15 FOUND THAT CANNOT PROVIDE 2000 P5F, THIS MATERIAL SHALL BE REMOVED IN ITS ENTIRETY AND REPLACED WITH COMPACTED STRUCTURAL FILL. IF TH15 CANNOT BE ACCOMPLI5HED, ALL CONSTRUCTION SHALL BE STOP AND THE ENGINEER SHALL BE CONTACTED TO PROVIDE DIRECTION AND TO POTENTIALLY REQUEST A GEOTECHNICAL INVESTIGATION JOB SITE SPECIFICATIONS SWIMMING POOL PLAN FOR: m DEE FIELD BEACH, FLL LOT: (y87 BLOCK: 15o JODY POLL ANO t 33442 SUBDIVISION: LAKEWOOD PARK UNIT 11 7100 SABAST/AN ROAD PHONE: G54-637-0707 PLAT BOOK: 32 PAGE: 32-A -320 FORT PIERCE, FLORIDA 34g51 COUNTY: ST LUCIE ELEGTRIGAL CODE, NOTES AND BONDING FBC 5TH EDITION RESIDENTIAL CHAPTER 42 SWIMMING POOLS (ELECTRICAL PROVISIONS) SHALL SPECIFICALLY GOVERN INCLUDING E4202 WIRING METHODS, E4203 EQUIPMENT LOCATIONS, E4204 BONDING, E4205 GROUNDING AND EQUIPMENT INSTALLATION FBC 5TH EDITION RESIDENTIAL APPENDIX Q PROVIDES A GROSS REFERENCE TO 2011 NATIONAL ELECTRICAL CODE, NFPA 70 FBC 5TH EDITION RESIDENTIAL E4203b OVERHEAD CONDUCTOR CLEARANCES AND FBC 5TH EDITION E4203b UNDERGROUND WIRING SHALL SPECIFIC -ALLY GOVERN FBC 5TH EDITION RESIDENTIAL E4204 BONDING. EQUIPOTENTIAL BONDING SHALL BE REQUIRED. THE PARTS (CONDUCTIVE POOL SHELLS, PERIMETER SURFACES, METAL COMPONENTS, UNDERWATER LIGHTING, METAL FITTINGS, ELECTRICAL EQUIPMENT AND ALL FIXED METAL PARTS) SHALL BE BONDED USING A SINGLE SOLID a & AWG BONDING WIRE, PLACED AROUND THE PERIMETER lb" TO 24" FROM THE POOL WATERS EDGE, PLACED 4" TO 6" BELOW GRADE, FOLLOWING THE CONTOUR OF THE PERIMETER SURFACE, CONNECTED TO THE STRUCTURAL STEEL REINFORCING IN FOUR (4) UNIFORMLY SPACED LOCATIONS BY EXOTHERMIC WELDING OR BY LISTED PRESSURE CONNECTORS OR CLAMPS THAT ARE LABELED A5 BEING SUITABLE FOR THI5 PURPOSE AND ARE OF STAINLE55 STEEL, BRA55, COPPER OR COPPER ALLOY. THIS SINGLE a 8 AWG WIRE WILL EXTEND UNDER CONCRETE, PAVERS AND UNPAVED SURFACES FBC 5TH EDITION RESIDENTIAL E4204.3 POOL. WATER. THE POOL WATER SHALL BE INTENTIONALLY BONDED BY MEANS OF A CONDUCTIVE SURFACE AREA NOT LE55 THAN G SQUARE INCHES (51) INSTALLED IN CONTACT WITH THE POOL WATER. IF 9 (51) 15 NOT ACCOMPLISHED BY THE BONDED ITEMS ABOVE A POOLBOND PB-2005:(,10.1 51) OR APPROVED EQUAL SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURES INSTRUCTION FBC 5TH EDITION RESIDENTIAL E4203.13 GFCI PROTECTION SHALL BE PROVIDED FOR POOL PUMP MOTORS 2011 NATIONAL ELECTRIC CODE (N..E.GJ. NFPA 70 SHALL GOVERN OUTSIDE IF THE PPOV15IONS ABOVE N.E.G. 43032 GONTIN000LJ -DUTY MOTORS SUCH AS POOL PUMP MOTORS SHALL HAVE OVERLOAD PROTECTION POOL EQUIPMENT AND ANCHORING POOL EQUIPMENT ELEVATION SHALL BE AT A MINIMUM OF THE DESIGN FLOOD ELEVATION (FBC 5TH EDITION RESIDENTIAL R322.1.4) PLUS I FOOT OR ACCORDING TO THE AUTHORITY HAVING JUR15DICTION FEY- 5TH EDITION BUILDING 1620 HVHZ WIND LOADS AND 1621 HVHZ OVERTURNING MOMENT AND UPLIFT POOL EQUIPMENT SHALL BE DESIGNED, CONSTRUCTED AND INSTALLED TO MEET THE REQUIREMENTS OF ASGE T EQUIPMENT TIE DOWN SHALL BE AS FOLLOWS, HEATERS 4 TOTAL (I PER SIDE OR 2 PER OPPOSITE SIDES) OTHERS 2 TOTAL: 3 Y2' MINIMUM THICK, 3000 PSI CONCRETE SLAB, 3" LARGER THAN ON EACH SIDE THAN THE EQUIPMENT.Y4" DIAMETER TAPCON CONCRETE SCREWS (1600# TENSION, 12G0# SHEER, I YZ" EMBEDMENT IN 2000 PSI CONCRETE) OR EQUAL WITH STAINLESS STEEL FENDER WASHER INTO FACTORY PROVIDED HOLD DOWNS OR I WIDE, 14 GAUGE GALVANIZED 5TRAP5 WITH 2 5TAINLE55 STEEL, u 10 X 3/4" PAN HEAD PHILLIPS 55 SCREWS EACH STRAP INTO METAL FRAME OF EQUIPMENT FBC 5TH EDITION BUILDING 1907.1 GENERAL: THE THICKNESS OF CONCRETE FLOOR SLABS SUPPORTED DIRECTLY ON THE GROUND SHALL NOT BE LE55 THAN 3 Ys INCHES THICK AND SHALL NOT REQUIRE A VAPOR BARRIER. FEIC 5TH EDITION RESIDENTIAL M1305.1.4.1 GROUND CLEARANCE. EQUIPMENT SUPPORTED FROM THE GROUND SHALL BE LEVEL AND FIRMLY SUPPORTED ON A CONCRETE SLAB EXTENDING NOT LE55 THAN 3" ABOVE ADJOINING GROUND FEY- 5TH EDITION RESIDENTIAL M2006 POOL HEATERS SHALL SPECIFICALLY APPLY, IF HEATER 15 PROVIDED FBC 5TH EDITION ENERGY CONSERVATION R403A.1,1 SHALL SPECIFICALLY APPLY WITH A MINIMAL THERMAL EFFICIENCY OF 83% IF A GAS HEATER IS PROVIDED AND FBC 5TH EDITION ENERGY CONSERVATION 403.4.1.2 SHALL SPECIFICALLY APPLY WITH A COEFFICIENT OF PERFORMANCE OF GREATER THAN 4, IF A HEAT PUMP 15 PROVIDED EQUIPMENT LOCATION AND SCREENIN(S. THE EQUIPMENT AND PIPING PHYSICAL LOCATION MAY DIFFER IN THE FIELD DUE TO UNFORESEEN CONDITIONS OR OTHER FACTORS. CONTRACTOR SHALL BE RESPONSIBLE TO LOCATE AND INSTALL ITEMS IN A LOCATION THAT MEETS LOCAL ZONING CODE AND TO PROVIDE CODE COMPLIANT LANDSCAPE OR FENCE SCREENING FLOOD ZONE FEIG 5TH EDITION RESIDENTIAL R322 FLOOD -RESISTANT CONSTRUCTION STRUCTURES CONSTRUCTED IN WHOLE OR PART IN FLOOD HAZARD AREAS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS OF THIS SECTION, ESPECIALLY R322.13 FLOOD -RESISTANT CONSTRUCTION AND R3222.4 POOLS IN FLOOD HAZARD AREAS, IF STRUCTURES CONSTRUCTED IN WHOLE OR PART IN FLOODWAYS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH ASCE 24 AND THE CONSTRUCTION OF THIS POOL WILL NOT INCREASE THE DESIGN FLOOD ELEVATION AT ANY POINT WITHIN THE JURISDICTION \'xx�%1111111///// \ NOHAM '\CE/V 0.57 6 •: NAME MARKHAM BENNETT �O�•.•. .� �G/; �� •, l R p P •.' ���� DRAWING ITEMS REVISIONS: P.E # 5721(o / M54) 51&-3b25 �/ • • • Q) 265 S. FEDERAL HWY. a 109 CSC • • • " • • <• �/ DATE: 7-12-11 DEERFIELD BEACH, FL 33441 WAYNE®WMB-PE.COM `� \\ /O' `~ i ORDER s 441 DRAWN BY: NAS. PLAN a 170707-21 IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THI5 DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE SHEET: 3 OF 3 VERIFIED ON ANY ELECTRONIC COPIES