HomeMy WebLinkAboutGenerator Concrete PadNGSH �\ GENERATOR___I x PAD ����x - THICKNESS D GVIA P ISOMETRIC VIEW PAD DIMENSIONS: CONCRETE PAD GENERATOR F = GENERATOR UNIT BY o SEPARATE SUBMITTAL (SEE SCHEDULE FOR M MINIMUM WEIGHT REQUIRED) 54" LENGTH PLAN VIEW.. CONCRETE PAD !' i, -1 ROAD MESH IASTERFIBER v 3 MIN' / MAC100 GROUND�Nf` AMERICAST GENERATOR CONCRETE PAD GENERATOR TABLE: (ON -GRADE APPLICATIONS ONLY) ON AMERICAST •MADE n4 AMHRIOA:• FEDTAxsic.9�=w � ucHNSBAm_-oosai63 S7 Pdff xa Aye. Fort Fierce, FL 34912 W. 772-971-19SE I = 772 464-OW Email• g1eQ"tnerFe•.Nusam "r eh•.lavdtt700101wha""e" HVHZ OR NON-HVHZ RISK EXPOSURE (EXP) RISK EXPOSURE (EXP) RISK EXPOSURE (EXP) COUNTY I C D I I C IUD�a t III;,IVi ( �C fi Il.p t) t( P. BEACH 150 MPH 30.44 Psf 36.94 Psf 170 MPFT 9.09 Psf 47.44 Psf 180 MPH 43 83 Psf 53.19 Psf. BROWARD 156 MPH 32.92 Psf 39.95 Psf 170 MPH !39.09Psf 47.44 Psf ;180`MPH 43:83Psf_ 5A19,Psf-. MIAMI-DADE 165MPH 36.83Psf 44.69Psf 175MPH 1.43 Psf 50.28 Psf 186 MPH 46.80 Psf 56.80 Psf BRAND & MODEL CAPACITY WIDTH LENGTH- HEIGHT ` WEIGHT, ALLOWABLE PRESSURE COMMENTS Generac 005871 & 005883 10 KW 25.00.." ` �48.00""- 387 Ibs+' 3 54.00 Psf EXP C 186 MPH & D 180 MPH Generac 005872 & 005884 14 KW 25.00" 48200"_ j 2900 " , , 439 Ibs 56.80 Psf UP TO EXPOSURE D 186 MPH Generac 6459, 6461, 6462 16 KW 25.00"' ' 48 00'"- 29.00 " /,513 Ibs-, �;56.80 Psf Generac 006721 16 KW 25.00 "' 48.00 29 00 "-1 f 448 Ibs -.,_ 56.80 Psf Generac 005873 & 005885 17 KW 25.00 " 48.00 " 29 00r": J'455 Ibs 56.80 Psf Generac 005874 & 005886 17 KW 25 00 ". r48 00 a 29 00 � 421 Ibs , a 56a80 Psf Generac 005875 & 005887 20 KW 25:OQ"� 48.00 29 OV""' =451 Ibs' " 56:80'Psf Generac 006729 & 006730 20 KW 25.00! -48.00(' 29.00`1J - 516 ]b`s- q �56.80 Psf Generac 006551 & 006552 22 KW 25.00 " 48.00 " 29.00" 526 Ibs 56.80 Psf Kohler 14RES & 20RES 14-20 KW 26.00 " 48.00 " 29.00 " 500 Ibs 56.80 Psf GE 40323GE & 40324GE 13 KW 35.00 " 39.40 " 39.00 " 540 Ibs 49.50 Psf EXP C 186 MPH & D 170 MPH GE 04038215KW 15 KW 33.00 " 48.00 " 30.50 " 484 Ibs 56.80 Psf I UP TO EXPOSURE D 186 MPH GE 04037817KW 17 KW 33.00 " 48.00 " 30.50 " 484 Ibs 56.80 Psf GE'40330GE & 40331GE 20 KW 33.00 " 48.00 " 30.50 " 600 Ibs 56.80 Psf Briggs & Stratton 040243-0 10 KW 31.00 " 32.00 " 34.00 " 430 Ibs 56.80 Psf Briggs & Stratton 040302-2 12 KW 33.75 " 50.00 " 31.60 " 507 Ibs 54.00 Psf EXP C 186 MPH & D 180 MPH Briggs & Stratton 040303-1 15 KW 33.75 " 49.00 " 31.60 " 562 Ibs 56.80 Psf UP TO EXPOSURE D 186 MPH Briggs & Stratton 040304-1 18 KW 33.75 " 49.00 " 31.60 " 568 Ibs 56.80 Psf Briggs &Stratton 040305-1 20 KW 33.75 " 49.00 " 31.60 " 570 Ibs 56.80 Psf Generac 7035, 7036, 7037 16 KW 25.00" 48.00 " 29.00 " 406 Ibs 47.44 Psf EXP C 186 MPH & D 170 MPH Generac.007038 & 007039 20 KW 25.00 " 48.00 " 29.00 " 448 Ibs 47.44 Psf Generac'007042 & 7043 22 KW 25.00 " 48.00 " 29.00 " 466 Ibs 47.44 Psf GENERATOR MOUNTING CONFIGURATION: GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE W/ (4) #10 SS 316 SELF -DRILLING 3/8 1 H H GENERATOR (SEE CONCRETE PAD ww SCHEDULE FOR x x DIMENSIONS & WEIGHT REQUIRED) 4" } 32" WIDTH 54" LENGTH o I SIDE VIEW FRONT VIEW N 0 c (SEE GI GENERATOR WIND DESIGN REOUIREMENTS_ (BASED ON ASCE 7-10 & FLORIDA BUILDING CODE FIFTH EDITION (2014)) AT -GRADE SIGN METHOD ULTIMATE DESIGN WIND SPEED VUlt = 186 mph NOMINAL DESIGN WIND SPEED Vasd = 144 mph RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= 0.85 ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H qh = 77.56 Ib/ft2 FORCE COEFFICIENT Cf = 1.44 WIND PRESSURE,: P = qh G Cf = 56.80 Ib/ft2 (ASD) L_ - - - - - - ANCHOR TO PAD SCHEDULE: SUBSTRATE DESCRIPTION CONCRETE: ( )- (6PSI EQUIVALENT,TITEN MINHD MIN.) 2-3/4" FULL EMBED O CONCRETE, 3" MIN EDGE DISTANCE, 6" MIN. SPACING TO ANY ADJACENT ANCHOR. NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2._ EMBEDMENT AND EDGE DISTANCE A. EXCL'UDES,FINISHES, IF --APPLICABLE._--_' 3 .,,,-ENSURE MINIMUM EDGE DISTANCE �i ti _-. AS`�NOTEC 4IN ANCHOR SCHEDULE. 4. ENSURE;MINIMUM,SPACING TO :ANY ADJACENT -ANCHORS. i L5 IFOLLOW MANUFACTURER'S INSTALLATION,INSTRUCrIONS TO -INSTALL ANCHORS,,+ 'ail {(+„aGENERAT,OR�- ATTACHMENT BASE,_.,. VARIES WITH'MODEL , SEE GENERATOR SPECS SIMPSON TIfEN HD, SEE ANCHOR SCHEDULE 2"x3"x3/a" GALV. STEEL - WASHER i RUBBER VIBRATION PAD - WASHER& RUBBER" VIBRATION PAD 1, CONCRETE PAD - 1 6,000 PSI * LIGHTWEIGHT CONCRETE 'PAD CONCRETE MIX 6,000 PSI LIGHTWEIGHT MASTERFIBER MAC 100 - 'CONCRETEIMIX s 4 `3 " & ROAD MESH C , ' NOTES v" V.> _ FOAM CORE 1..r 'Y'DISTANCE DEPEND -ON GENERATOR BASE LENGTH, NO•LESS THAN 2". 2. X DISTANCE 3" FROM UNIT EDGE TO CLIP. 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN ANCHOR REQUIREMENTS lF�---• iE jl - w' ee GENERAL NOTES . =1 co T �2"--t 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2014 FLORIDA BUILDING CODE (5th EDITION). 2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH THE APPLICABLE BUILDING CODE SHACcBE-LESS THAN OR EQUAL TO THE DESIGN` PRESSURE'ASD° CAPACITY VALUES LISTED HEREIN FOR ANY -ASSEMBLY AS SHOWN jl' 3. DIMENSIONS ANDjWEIGHT OF UNITS S_HALC' NE "R'M TO SPECIFICATIONS STATED-HEREIN.-._� 4. UNITS MUST BE CENTERED. ON' P.AD WITH OPPOSITE SIDES HAVING EQUAL CLEARA- ANCE MINIMUM DISTANCEFROM UNIT TO PAD EDGE IS SPECIFIED. 5. THE AREA UNDER CONCERETE SLAB ON�GROUND-SHALL HAVE ALL VEGETATION, STUMPS ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR TO INSTALLATION 0N'COMPACTED SOIL AS VERIFIED BY OTHERS. 6. RESISTANCE TO_SLIDING OF THETAD ONtTHEIGROUND ISINOT PART OF THIS' DOCUMENT AS SOIL`CHARACTERISTICS AND PAD PLACEMENT VARIES 7. ELECTRICAL GROUND- HEN REQUIRED,=TO'BE-bESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 8. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 9. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 10. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR:- 11. THIS DOCUMENT IS GENERIC'AND-DOES NOT PERTAIN TO ANY SPECIFIC PROJECT SI .E,INFORMATION CONTAINED AEREIN IS BASED ON CONTRACTOR -SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS"OR INACCURATE DATA OR MEASUREMENTS DIMENSIONS ARE SHOWN TO`ILLUSTRATE DESIGN FORCES ANDLbTHER-DESIGN CRITERIA sTHEY',MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN WORK SHALL -BE FIELD :VERIFIED'BY CT OTHERS PRIOR TO CONSTRUION. ERGIIVEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPONiDISCOVERY OF ANY , INACCURATE INFORMATION -PRIOR -TO MODIFICATION OF EXISTING .. - EXISTING FIELD CONDITIONS ANDTABRICATION AND. INSTALLATION OF MATERIALS'ALTERATIONS,:ORIADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. 12. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. ANK L. BENNARDO, P.E. 46549 N-3�01 IFCHRXED, QAfiFfINGPEAnQS 6R0V1 ANK L. BENNARDO, P.E. 0 N Z,-I Ito p L"u M'Ux W I--" rl j'd OU to W � 'LL � LLI co LL X W ik rZfn1W. OLULU =°zar W ~ � < Lu U Y �Q W �wt70 a[II��Z W W O N _j W LLJ � (7 U) O' a=w W O LIJ ui OO ,-I w J L Q IL cpIn V Q O ` rn w 0 rt � U < Z H w J a rn m a 0 C07 Qa H N a J C1 C� O •J CDF=F Y z G ll { M cid w w r, V) O M Z U 'T LU -I /I6 C a Y ,ti fn Q In �: . �` t,�Q ce 0 YEI 1. LL �k 8 S n O r MOS. o o z u'7 w m 10 o w� 5LL o3001. z O O o g it 0 asg in w wi"°"ia mWE Y w w 0 � �o c ¢ w o n aid W z 0�sw o COPYRIGHT ENGINEERING EXPRESS 17-3961.1 SCALE: NTS UNLESS NOTED OF� I