HomeMy WebLinkAboutGenerator Product Review16/20/22 kW I CL DES: ST. LUCIE COUNTY BUILDING DIVISION . REVIEWED FOR CO LlInAl2�52-j7V REVIEWED BY DATE _ -� � � 7 P NS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE ® True Power' Electrical Technology 0 Two Line LCD Multilingual Digital Evolution'"" Controller (English/Spanish/ French/Portuguese) o Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. Se P GENERAL' GUARDIAN® SERIES Residential Standby Generators Air=iaooled Gas Engine Standby Power Rating iviodels G007036-0, G007037-0 (Aluminum - Bisque) - '16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz Models G007039-0, G007038-0 (Aluininut-n - Bisque) - 20 kW 60 Hz Models G007043-0, G007042-0 (Aluminum - Bisque) - 22 kW 60 Hz e age 4 for Details. K-2 1 1 > 1�, t, - 19 Electronic Governor Ili F; rid y - System Status & Maintenance Interva t, l LSD" Indicators ® Sound Attenuated Enclosure IO NERAM (9 Flexible Fuel Line Connector Direct -To -Dirt Composite Mounting Pad J "� 0 Natural Gas or LP Gas Operation ui DS QUIi�� ® 5 Year Limited Warranty Llsrro © Capability to be installed within 18" 457 mm limiiea ICICrcuitswilches�Unifspac�kagedi�thttie6r��£wllchareUlsCeruledin of a building* ( ) the USA only. *Only If located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O success in providing the most reliable generators possible, Generac's G-Force engine lineup offers added peace of mind and.reilabiiify for when you need It the most. The G-Farce series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER"' ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. it provides optimized FAST RESPONSE to changing load conditions and MAXIMUM -MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at:tl%. SINGLE SOURCE SERVICE RESPONSE from Generec's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are Nr PROTOTYPE TESTED NEMA M01.22 EVALUATION synonymous with GENERAC POWER SYSTEMS, One reason for this J SYSTEM TORSIONAL TESTED d MOTOR STARTING ABILITY confidence is that the GENERAC product line includes Its own transfer systems and controls for total system compatibility. G- E N ERA C t7.3so ����A� i— RRP Mobile LnkPROMISE a •mlmmrn.nu�,mor efBcMO/ Ipnpyry, GENERAC" 1 6/2®/22 kW features and benefits Engine • Generac G-Force design Maximizes engine "breathing" forincreased fuel efficiency. Plateau honed cylinderwalls and plasma molyrings helps the engine run cooler, reducing oil consumption resulting in longer • "Spiny-lok" cast iron cylinder walls engine life. Rigid construction and added durability provide long engine life. • Electronic Ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field • Skewed stator Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Displaced phase excitation Produces a smooth output waveform for compatibility with electronic equipment. Maximizes motor starting capability. 0 Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution'" Controls ® Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. s Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing • Generator voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Utility Interrupt delay Constantly monitors generator voltage to ensure the cleanest power delivered to the home. Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up ® Engine cool -down Ensures engine is ready to assume the load, setpoint approximately 5 seconds. Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing, flexibility and potentially lower fuel costs to the owner. o Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. A Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking root panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- Ically applied textured epoxy paint for added durability. m Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. ® Small, compact, attractive Makes for an easy, eye appealing Installation, as close as 18" away from a building. Installation System ® 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration wtie�nfconnected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. • Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. GENERAC 16/20/22 kW specifications Generator Model 0007O35.O, GOO7O36.O, 0OO7O38-0, GOO7O39-0 GOO7O42.O, GOO7O43.O 6007O37.O (16 kW) (20 kW) (22 kW) Rated Maximum Continuous Power Capacity (LP) 16,000 Watts" 20,000 Watts' 22,000 Rated Maximum Continuous Power Capacity (NG) 16,000 Watts" 18,000 Watts' 19,500 Rated Voltage I 240 240 240 Rated Maximum Continuous Load Current— 240 Volts (LP/NG) 66.6/66.6 83.3/75 91.6/81.3 Total Harmonic Distortion Less than 5% Less than 5% Less than 5% Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp Phase 1 1 1 Number of Rotor Poles 2 2 2 Rated AC Frequency 60 Hz 60 Hz 6OHz Power Factor 1.0 1.0 1.0 Battery Requirement (not included) 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 65O CCA Minimum Unit Weight (lb/kg) Dimensions (L x W x H) (n/mm 406/186 448/203 466/211 48 x 25 x 29/1218 x 638 x 732 Sound output in dB(A) at 23 ft'(7 m) with generator operating at normal load* • 66 66 67 Sound output In dB(A) at 23ift (7 m) with generator In Quiet -Test'" low -speed exercise mode"' 58 58 58 Exercise duration 5 min 5 min 5 min Engine Type of Engine GENERAC G-Force 1000 Series Number of Cylinders ! 2 2 2 Displacement 999 cc 99900 999 cc Cylinder Block Aluminum w/ Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/ Magneto Solid-state w/ Magneto Solid -stale w/ Magneto GovernorSyslem Electronic Electronic Electronic Compression Ratio 9.5:1 9.5:1 9.51 Staffer 12 Vdc 12 Vdc 12 Vdc Oil Capacity Including Filter ' Approx.1.9 gt/1.8 L Approx 1.9 gV1.8 L Approx.1.9 gV1.8 L Operating rpm 3,600 3,600 3,600 Fuel Consumption Natural Gas ( fl3/hr (m3/hrj 1/2 Load 218 (6.17) 204 (5,78) 216 (6.12) Full Load Liquid Propane 113/hr (gal/hr) [I/hr] 309 (8.75) 301 (8.52) 310 (8.78) 112 Load 91.6 (2.52) [9.53] 86 (2.37) [8.99] 93.2 (2.56) [9.70] Full Load 106.8 (2,94) [11.11) 129.6 (3.56) [13.481 140 (3.87) [14.65] Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel Inlet at all load ranges - 3.5-71 water column (7-13 mm mercury) for natural gas, 1 O-12" water column (19-22 min mercury) for LP gas. For Btu content, 3 multiply 11/hrx 2500 (LP) or ft3/hr x 1000 (NG). For Megaloule content, multiply m3/hr x 93.15f °r LP � For multiply 2500 (LP) or x 100O (NG). For Megaloule content, multiply m3/hr x 93.15 (LP)or ma/hi x 37.26 ING)m'/hr x 37.26 ING) Controls 2-Line Plain Text Multilingual LCD Display Simple user interlace for ease of operation. Mode BiRons:Aulo Automatic Slan•on Utility failure, 7 day exerciser. Manual ' Start with starter control, unit slays on. If utility fails, transfer to load takes place, Oft i Stops unit. Power Is removed. Control and charger stilt operate. Ready to Run/Maintenance Messages Standard Engine Run Hours Indicalto6 ;` ! Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Utility Voltage Loss/Return to Ulllity. Adjustable (Brownout Selling) Future Set Capable Exerciser/Enercise Sol Error Warning From 140-171 V/190-216 V Run/Alarrn/Maintenance Lags i Standard 50 Events Each Engine Start Sequence Cyclic cranking:16 sec on, 7 rest (90 sac maximum duration). Starter Lock -out ! i Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Faull/Mtssing AC Warning , Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulatioriwilh;Overand Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcunent Protection Standard SafelyFused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard OvercranWOverspeed (@ 72Hz)/r`pm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal FaultAncorrect Wiring Protection Standard Common External Fault Capability Standard Field Upgradable Firmware Standard "Sound levels are taken from the frontof the generator. Sound fevelstaken from other sides of the generator may behlgher depending on Installation parameters. Hating definitions -Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings In accordance with BS5514,IS03046and DIN6271)•* Mwdmum Mlovaltamps and current are Subject to and limited bysuch factors as fuel 11wimegaloule content, ambient temperature, aletude, engine power and condition, etc. Maximum power decreasesabout 3.5 percent for each 1,000 feet (304.8 motors) above sea level; and also will decrease aboull percent for each 6 `C (101) above 16°C (60 T). GENERAL' 16/20/22 W switch options Limited Circuits Switch Features ® 16 circuits, breakers not included. 0 Electrically operated, mechanically -held contacts for fast, positive connections 0 Rated for all classes of load,100% equipment rated, both inductive and resistive. a 2 pole, 250 VAC contactors. m 30 millisecond transfer time. ® Dual coil design. m Rated for both copper and aluminum conductors. ® Main contacts are silver plated or silver alloy to resist welding and sticking. ® NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. 0 Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions Height Width Depth H1 H2 Wi W2 In 26.75 30.1 10.5 13.5 6.91 mm 679.4 764:3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 2/0-#14 210-#14 Service Rated Smart Switch Features 0 Includes Digital Power Management Technology standard (0PM). 0 Intelligently manages up to four air conditioner loads with no additional hardware. 0 Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). 0 Electrically operated, mechanically -held contacts for fast, clean connections. ® Rated for all classes of load,100% equipment rated, both inductive and resis- tive. • 2 pole, 250 VAC contactors. 0 Service equipment rated, dual coil design. m Rated for both aluminum and capper conductors. 0 Main contacts are silver plated or silver alloy to resist welding and sticking. NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- Ing flexibility. Dimensions 200 Amps 120/240,1 e Open Transition Service Rated Height Width H1 H2 W1 W2 Depth In 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 Model 6007036.0 (1fikW) No. of Pales 2 Current Rating (Amps) 100 Voltage Rating (VAC) 120/240.10 Utility Voltage Monitor (Fixed)' -Pickup 80% -Dropout 65% Return to Utility approx.15 seo Exercises bi-weekly for 5 minutes't Standard UL Listed Standard Total Circuits Available 16 Tandem Breaker Capabilities 8 spaces Circuit Breaker Protected Available RMS Symmetrical 10,000 Fault Current @ 250 Volts *Function of Evolution Controller Exercise can be set to weekly or monthly DEPhI Model G007037.0 (16 kM/GO07039.0 (20 kW)/ G007043.0 (22 kW) No, of Poles 2 Current Rating (Amps) 200 Voltage Rating (VAC) 120/240,10 UtilityVoltage Monitor (Fixed)* -Pick-up 80% -Dropout 65% Return to Utility approx.13 sec Exercises bi-weekly for 5 minutes' Standard UL Listed Standard Enclosure Type NEMA/UL 3R Circuit Breaker Protected 22,000 Lug Range 250 MCM - #6 *Function of Evolution Controller Exercise can be set to weekly or monthly oarrn GENERAC° 16/20/22 kW specifications Generator Model 0007035.0, 6007036.0, 0007038-0, (1007039-0 G007042-0, G007043.0 G007037.0 (16 kW) (20 kW) (22 kW)er Rated Maximum Continuous PowCapacity (LP) 16,000 Watts" 20,000 Walls' 22.000 Rated Maximum Continuous Power Capacity (NG) 16,000 Watts" 18,000 Walls" 19,500 Rated Voltage I 240 240 240 Rated Maximum Continuous Load Curren( — 240 Volts (LP/NG) 66.6/66.6 83.3/75 91.6/81.3 Total Harmonic Distortion Less, than 5% Less than 5% Less than 5% Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp Phase , 1 1 Number of Rotor Poles Rated AC Frequency 60 Hz 60 Hz 6OHz Power Factor 1.0 1.0 1.0 Battery Requirement (not included) 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit Weight (lb/kg) 406/186 448/203 466/211 Dimensions (L x W x H) in/mrit 48 x 25 x 29/1218 x 638 x 732 Sound output in dB(A) at 23 f . (7 m) with generator operating at normal load— 66 66 67 Sound output In dB(A) at 23!ft (7 m) with generator in Quiet -Test'" low -speed exercise mode'" 58 58 58 Exercise duration 5 min 5 min 5 min Engine Type of Engine GENERAC G-Force 1000 Series Number of Cylinders i 2 2 2 Displacement 999 cc 999 cc 999 cc Cylinder Block Aluminum w/ Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/ Magneto Solid-state w/ Magneto Solid -stale w/ Magneto Governor System Electronic Electronic Electronic Compression Ratio 9.5:1 9.5:1 9.5:1 Stager 12 Vdo 12 Vdc 12 Vdc Oil Capacity Including Mild. Approx 1.9 gV1.8 L Approx 1.9 gV1.8 L Approx. 1.9 gU1.8 L Operating rpm 3,600 3,600 3,600 Fuel Consumption Natural Gas fta/hr (ms/hr) 1/2 Load 218 (6.17) 204 (5.78) 216 (6.12) Full Load Liquid Propane fta/hr (gal/hr) [Vhr] 309 (8.75) 301 (8.52) 310 (8:78) 1/2 Load 91.6 (2.52) [9.53] 86 (2.37) [8,99] 93.2 (2.56) [9.70] Full Load Note: Fuel pipe must be sized for full load. Required fuel pressure to generator 106.8 (2.94).[11.11] 129.6 (3.56) [13.481 140 (3.87) [14.651 fuel Inlet at all load ranges - 3.5-7, water column (7-13 minmercury) for natural gas, 10-12'water column (19-22 mm mercury) for LP gas. For Btu content, multiply ((3/hr x 2500 (LP) or fl3/hr x 1000 (NG). For Meoatoule content, multiply m3Rtr x 93.15 (LP) or m3/hr x 37.26 (NG) Controls ' 2-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. Mode BultonsAuto i Automatic Stag on Utility failure, 7 day exerciser. Manual ith Staff wstarter control, unit stays on. If utility faits, transfer to load takes place, Off Stops unit. Power is removed. Control and chargerstill operate. Ready to Run/Maintenance Messages Standard Engine Run Hours Indication' i Standard Programmable slag delay between 2-1500 seconds Standard (programmable by dealer only) Utility Voltage Loss/Return to Uhlily Adjustable (Brownout Selling) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error Warning Standard RurVAlarrn/Maintenance Log's ! 50 Events Each Engine Stag Sequence Cyclic cranking: 16 sec on, 7 rest (20 sec maximum duration). Stager Lock -out i ; . Stager cannons -engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Faull/Missing AC Warning Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulaliof wilh�OverandUnderVoltageProtection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem'Pro(eclibn Standard Automatic Low oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed (@ 72iHz)/rpinSense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Faultnncorrect Wiring Protection Standard Common External Fault Capability Field Upgradabte Firmware - Standard ;f, l , "Sound levels -n�,.-T°^'"�'-. � Standard are taken from the wont of the genecrtor. Sound levels taken from other sides orthe generator may behigher, depending on installadan parameters. flaring deONlions-Standby. Applirablefor supplying emergency power forthe duradon 01theetNllHPower Outage .Nooverload apabllltyisavallablefor this mfing.(Ail ratIngsInaccordanwwith BS5614,IS03046and 01N6271).•MannumNlovoltamps and anentamsubject toand limited bysuch factors as fuel Bh✓megaloule contenunbienitemperalwe,algtuds, engine powerand condldon, etc. Mapmum power decreases about 3.5 percealfor each 1,000 feet(304.6 meters) above sea level; and alsowill decrease about i percent for each 6 `C (10 `F) above 16 °C (60 °F). t � ti. GENERAL" 16/20/22 W switch options Limited Circuits Switch Features • 16 circuits, breakers not Included. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load.100% equipment rated, both inductive and resistive. • 2 pole, 250 VAC contactors. a 30 millisecond transfer time. • Dual coil design. ® Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. o NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. ® Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions Height Width Depth H1 H2 Wt W2 In 26.75 30.1 10.5 13.5 6.91 mm 679.4 764:3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 2/0-#14 210-#14 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). v Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resis- tive, • 2 pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 120/240, to Open Transition Service Rated Height Ht H2 Width Wt W2 Depth In 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 Model G007036.0 (16kW) No. of Poles 2 Current Rating (Amps) 100 Voltage Rating (VAC) 120/240.10 Utility Voltage Monitor (Fixed), -Pick-up 80% -Dfopoui 65% Return to Ulllily' approx.15 sec Exercises bi-weekly for 5 minuies'1 Standard UL Listed Standard Total Circuits Available 16 Tandem Breaker Capabilities 8 spaces Circuit Breaker Protected Available RMS Symmetrical 10,000 Fault Current @ 250 Volts *Function of Evolution Controller Exercise can be set to weekly or monthly oErm Model 0007037.0 (16 kM/G007039.0 (20 kW)/ 6007043-0 (22 I(W) No, of Poles 2 Current Rating (Amps) 200 Voltage Rating (VAC) 120/240.10 UIIIityVoltage Monitor (Fixed), -Pickup 80% -Dropout 65% Return to Utility' approx.13 sec Exercises bi-weekly for 5 minutes* Standard UL Listed Standard Enclosure Type NEMANL 3R Circuit Breaker Protected 22,000 Lug Range 250 MCM - #6 *Function of Evolution Controller Exercise can be set to weekly or monthly OEPTTI GENERAC 16/20/22 kW available accessories Model.# , Product Description Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- G006463.4 Mobile Link'" cess to an internet connection from a PC or with any smart device. You will even be notified via a -mall or text message when a change in the generator's status occurs. Available in the U.S. only. 0005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet battery for cell use with all air-cooled standby product (excluding PowerPact®). G007101-0 ;Battery Pad Warmer The pad warmer rests under the battery. Recommended for use If the temperature regularly falls below 0°F. (Not necessary for use with AGM -style batteries), G007102-0 Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 0°F. G007103-0 Breather Warmer The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007027.0 - Bisque (Standard on 22 It" sleek, contoured appearance as well as offering protection from rodents and Insects by covering the lifting holes located In the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from G005703-0 - Bisque Paint Kit future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. G006873-0 Smart Management Module Smart Management Modules are used In conjunction with the Automatic Transfer Switch to increase its (50 Amps) power management capabilities. It provides additional power management flexibility notfound in any other power management system. dimensions & PCs Dimensions shown are approximate. Refer to Installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES, rFrraroevIEw FRONTVIEW }ni,rritr,:t :� Model UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378 G007038-0 696471070385 G007039-0 69647107.0392 G007042-0 696471070422 G007043-0 696471070439 N RAC� Generac Power Systems, Inc. S45 W29290 HWY. 59, Waukesha, WI 53189 o generae.com ©2016 Generac Power systems, Inc' All'righls reserved. All specifications are subject to change wllhout notice, Part No. 10000000194-010/24/16 Smart Management Modules (SMM) GENERAC 0 r GENERIC° ACCESSORIES Model G006873-0 C M� DS LISTED DEUMPTION Generac's Smart Power Management System is designed to optimize the performance of a standby generator. The system can consist of up to 8 individual Smart Management Modules (SMM). Unlike other load management systems that depend on another control device, the SMM modules are actually self - aware and operate autonomously. Frequency is the true measure of generator engine performance and does not need to factor in increased ambient temperatures, elevation changes or generator fuel type. The modules monitor the frequency (Hz) of the power being produced by Generac's standby generators and if It falls below a certain threshold, the module will automatically follow a power management algorithm to ensure that the generator is not overloaded. The modules can be set to a load priority between 1-8 or be set in a lock out only mode for loads that just simply do not need to run in an outage, therefore reducing the necessary size of the generator for a more cost effective solution. SNM SPECIFICATIONS Power Supply Source.........,.• .............. Supported Voltages ............................................ 240 VAC (from Line input) Contactor Coil Voltage ..................... :.............,,... Coil VA Inrush . ............. 240 VAC CoilVA Sealed..,..•,,,.,•,•..................•..........,•,,.,.........................,..................,........,.••..,......,.........•...•....,........•........,.............,........,.....,.......................,..,.•..,........,...,..........240 VAC Pales ....... 30 ResistiveAmps..............................:.........................................................•,..••.,•...,,,,.........,•.•.......,.......,,....,........,,............,....................•............,..,........,..,,..,. 6.5 ......•.•. F/L Inductive Amps...............•.,,.....,.•................,....,,..,.,....•., Locked Rotor Amps.,•.........................................................,.........,..,. 50 UI 50........, 40 EnclosureRating..................................•....•.•.............,............ : ....V......,•.....,,.,..•.,,,.,•,..•...,•,.,,..,.......,..,..............,,...............................240@240V ............... Yes ................................................ .... ................................................. NEMA 3R GENERs! C GENERAC° Smart Management Modules (SMM) Dimensions and UPC Model G005873.0 Height (fn/mm) H1 H2 6.17/158.8 2.36/60 Width (iNmm) W1 W2 7.06/179.4 4.72/120 Depth (in/mm) 3.7/94 Weight (Ibs/kilos) 2.06/0.94 Shipping Weight (lbs/kilos) 2.44/1.11 UPC Code 696471068733 SWIM Controls (located behind the coiner of the module) I LED ON = LOAD CONNECTED PRIORITY LOCKOUT LED FLASH 1S = LOAD SHED 6 LOAD ON LED FLASH 3S = 30 MIN LOCKOUT A GENERATOR 3 �--- LED FLASH GS = GEN LOAD LOCKOUT LED OFF = NO MODULE POWER ® ® 0 O o LOCKOUT TEST DISABLED Priority Dial (A) — Sets rrodule priority. Lockout Switch (B) — Prevents load from operating when system is operating under generator power. Test Billion (C) — Disables contactor output for a specified lime. LED (D) — Provides module status with easy viewing through the external viewing window located in the upper rtghl,comer of.lhe module, Generac Power Systems, Inc. 645 W29290 HWY. 59, Waukesha, WI 53189 o generac.com GEI�ERACD ®2016 Generac Power systems, Inc All rights reserved. All specifications are subject to change wlthoul nollce. Bulletin OL1500-C 03/10/16 Site Selection and Preparation sects®n .31'- Site Selection and Preparation Site Selection I Orr 5 ft (1.52 m) r � i © a- 3 ft (0.91 m) 7777 5ft(1.52m) r aft (0.91 m) 3 ft d (0.91 m) OO B F Figure 3-9. Installation Clearances ID Description Comments A Top of generator — B Front and end clearance Minimum clear distances cannot include shrubs, bushes, or trees. C Rear clearance 18 in (45.7 cm) minimum clearance per NFPA testing, labeling, and listing, unless state or local codes dictate otherwise. D Windows and openings No operable windows, doors, or openings in the wall are permitted within 5 ft (1.52 m) from any point of the generator. E Existing wall One -hour fire rated walls allow closer placement of the generator set. Confirm before Installation. F Removable fence Removable fence panels for servicing cannot be placed less than 3 ft (0.91 m) in front of the generator. G Overhead clearance 5 ft (1.52 m) minimum distance from any structure, overhang, or projections from the wall. DO NOT install under wooden decks or structures unless this distance is maintained. Installation Guidelines For 60 Hz Air -Cooled Generators 11 Site Selection and Preparation Install the generator set, in its protective enclosure, outdoors where adequate cooling and ventilatingair is —The generator must be installed on a level sur- always available (Figure 3.1). Consider these factors: face. The generator must be level within a 0.5 in ° The installation of the (13 mm) all around. generator must comply — The generator is typically placed on pea gravel, strictly with ICC IFGC, NFPA 37, NFPA 54, NFPA compacted soil, crushed stone, or a concrete 58, and NFPA 70 standards. o Install the unit where air inlet and outlet openings pad. Check local codes to see what type is required. If a concrete pad is required, will not become obstructed by leaves, grass, snow, all appli- cable codes should be followed. etc. If prevailing winds will cause blowing or drifting, consider using a Windbreak to protect the Installation Guidelines for Stationary unit. Air -Cooled Generators • Install the generator on high ground where water levels will not rise and endanger NFPA 37 is the The National Fire Protection it. This unit should not operate in or be subjected to standing water, Association's standard for the installation and use of stationary combustion engines. Its ° Allow sufficient room on all sides of the generator for maintenance and servicing. This requirements limit the spacing of an enclosed generator set from a structure or wall (Figure 3-1). unit must be installed in accordance with any local, state, or national codes for minimum distances NFPA 37, Section 4.1.4, Engines Located Outdoors: Engines, from other structures. and their weatherproof housings if provided, that are installed outdoors shall be located ° Clearance from the ends and front of the generator at least 5 ft (1.52 m) from openings in walls and at least 5 ft (1.52 m) must be 3 ft (0.91 m). This includes shrubs, bushes, and trees. Clearance from the back of the from structures having combustible walls. A minimum separation shall not be required where the following generator must be a minimum of 18 in (457 mm). conditions exist: Clearance at the top should be a minimum of 5 ft (1.52 1 • The adjacent wall of the structure has a fire m) from any structure, overhang, or projections from the wall. resistance rating of at least one hour. ° DO NOT install under wooden decks or structures 2. The weatherproof enclosure is constructed of noncombustible materials and it has been unless there is at least 5 ft (1.52 m) of clearance above the demonstrated that a fire within the enclosure will ignite generator. ° Install the unit where rain gutter down spouts, not combustible materials outside the enclosure. roof run-off, landscape irrigation, water sprinklers, or sump pump discharge does flood Annex A — Explanatory Material not the unit or spray the enclosure, including any air inlet or outlet A4.1.4 (2) Means of demonstrating compliance are by openings. means of full scale fire test or by calculation procedures. ° Install the unit where services will not be affected Because of, the limited spaces that are frequently or obstructed, including concealed, underground, available for installation, it has become apparent that or covered services such as electrical, fuel; phone, exception (2) would be beneficial for many residential air conditioning, or irrigation. This could affect and commercial installations. With that in mind, the warranty coverage. ° Where manufacturer contracted with an independent testing laboratory to run full scale fire tests strong g g prevailing winds blow from one direction, face the generator air inlet to assure that the enclosure will not ignite combustible materials outside openings to the prevailing winds. the enclosure. ° Install the generator as close as possible to the fuel NOTE: Southwest Research Institute testing approves supply to reduce the length of piping. REMEMBER THAT LAWS OR CODES MAY REGULATE 18 in (457 mm) installation minimum from structure (Figure 3.1, C). Southwest Research Institute is THE DISTANCE AND LOCATION. In the absence of a nationally recognized third party testing and listing local codes regarding placement or clearance, agency. we recommend following these guidelines: The criteria was to determine the worst case fire scenario — Install the generator as close as possible to the within the generator and to determine the ignitability of transfer switch. REMEMBER THAT LAWS OR items outside the engine enclosure at various distances. CODES MAY REGULATE THE DISTANCE AND The enclosure is constructed of non-combustible LOCATION. T materials, and the results and conclusions from the "independent testing lab indicated that any fire within the 12 Installation Guidelines For 60 Hz Air -Cooled Generators Site Selection and Preparation generator I e - -sure would not pose any ignition risk to nearby combustibles or structures, with or without fire service personnel response. seRf D M Eof of 44..14 of11F0 37 LIS7ED BY: Wdlwast Research - 6hsStute See Ahht *, Tama NOTE 1 (30 CHAR. "' io—, ® NOTE 2 l30 CHAR pap,Q .....-- " " NOTE 3 0 cM MA)O_�,o ' N07E 4 (30 CHAR MAX_, NOTE T, (" CHAR "".,,.,y_- . NOTE S 130 CHAR "'^..„`—., NOTE 7 (30 CHARMAX--, WE= aom srst m W Figure 3-2, Southwest Research institute Marking http:I/www, swrl.org/4org/dollrlrellistlabgistprod/dFrector htm Based on this testing and the requirements of NFPA 37, Sec 4.1.4, the guidelines for installation of the generators listed above are changed to 18 in (457 mm) from the back side of the generator to a stationary wall or building (C). For adequate maintenance and airflow, clearance, the area above the generator should be at least 5 ft (1.52 m) with a minimum of 3 ft (0.91 m) at the front and ends Of the enclosure. This includes trees, shrubs, and bushes. Vegetation not in compliance with these clearance parameters could obstruct air flow. In addition, exhaust fumes from the generator could inhibit plant growth. See Figure 3-1 and the installation drawing within the owner's manual for details. I � e Automatic start-up. Disconnect utility power and render unit inoperable before working on unit. Failure to do so will result in death or serious injury. (000191) g's t B . Asphyxiation. Running engines produce carbon monoxide, a colorless, odorless, Poisonous all if not avoided, willresu t in death as. Carbon norxserious injury. (000103) MOTE: If the generator is not set to OFF, it can crank and start as soon as the battery cables are connected. If,the utility power supply is not turned off, sparking can occur at the battery posts and cause an explosion. ,a Site Preparation Locate the mounting area as close as possible to the transfer switch and fuel supply. Leave adequate room around the area for service access (check local code), and place high enough to keep rising water from reaching the generator. Choose an open space that will provide adequate and unobstructed airflow. Place the unit so air vents won't become clogged with leaves, grass, snow, or debris. Verify that exhaust fumes will not enter any building through eaves, windows, _ ventilation fans, or other air intakes (see Site Selection). Select the type of base, such as —but not limited to —compacted soil, gravel, or concrete, as desired or as required by local laws or codes. Verify your local requirements before selecting. Material Sufficient for Level Installation Prepare a rectangular area approximately 5 in (127 mm) deep (A) and approximately 6 in (152 mm) longer and wider (B) than the footprint of the generator. Verify that the surface where the generator will be mounted is compacted, leveled, and will not erode over time. A concrete pad can be poured if desired or required. �i✓ Figure 3-3. Compacted Soil or Gravel Pad NOTE: If a concrete pad is required, follow all applicable federal, state, or local codes. Installation Guidelines For 60 Hz Air -Cooled Generators ". 13 SITE PLAN FOR .. HARBOUR RIDGE, LTD. HARBOUR RIDGE PLAT NO 13. ACCORDI G0T WINE PLATA7HEREOFERECORRDED IN PLAT BOOK 28 - PAGES 3A -3H . ST. LUCIE COUNTY. FLORIDA. :` WET PRAIRIE PEON AREA � RTYARD ELEVATIONS SHOWN THUSLY NOOECOU FINISHED FLOOR !2m 1 REFER TO N. G. V. D. 1929. ADDRESS-, 1515 ,.MORASS NAY PALN CITY. FLORIDA 33490 MOCK. BOOS S ASSOCIATES, INC. tMAMAPR '-40' Ft4Ja N/A ■••�,�.�. Pnpor�d for i990 EIr91NEfJ6 0 SIIRYEYQRS 0 r'.UlIERS105T PALN BEACH, FLOi,10A KUMRI061; LTD. B9-133 �74 3- m6- -� i� ST. L ,CIE COUNTY r� BUILDINO DIVISION .•1' �— REVIEWED FOR COM IA �a� f REVIEWE BY DATE p� PLANS A PERMIT MUST BE KEPT ON JOB OR (A ``) V NO INSPECTION WILL BE MADE CJ� � cam} �: {: Optional Load Calculation Heat Larger Than Air I SF x 3VA Living Only (2) Small appliance ckts @ 1500VA each Refrigerator @ 1500 - 3000 _ -- �+ ® � Refrigerator @ 1500 Freezer @ 1500 Washing Machine @ 1500 Dishwasher @ 1500 — ®� - Disposal @ 1500 - d 0 Mini Sewer @ 1500 _ p D Clothes Dryer @ 5000 Range @ 12000 Water heater @ 4500 Fixed microwave @ 1500 Vacuum @ 1500 _ Trash Compactor @ 1500 Pool Heater @'name plate' _ Spa @ 'name plate' Motors 746VA per HP r� oo Pool Garage Door Opener _ ESQ 1) Total = % 5 &Z '7 1 2) First 10 KVA of general load @ 100% 3) Subtract line 2 from 1 cl�� 4) Multiply line 2 @ 40% 5) Add lines 2 and 4 _ 13 9541. 6) 60/50amp breaker for heat (10000) 7) 40/30amp breaker for heat (5000) - — 8) Total heat- Add lines 6 and 7 9) Multiply line 8 @ .65% _ 6 S)o 10) Add lines 5 and 9 = � 11) Divide line 10 by 240 Summary: Line 10 Is the total KW Line 11 Is the total Amps (Generator Size Needed) (Breaker Size Needed)