HomeMy WebLinkAboutProduct Approval Roofing Underlaymentsi
d _ �
4--'-'d.
•....-ta, ...� ::-n .«+.. �' .M- D@.�+�ItOtti A}i'Dll,[,08R . 8�f�bi�t3.I�KS` _t,
is Product Approval
r USEW Public User
Product Approval Menu > Product or Application
Search > Application List > Application"Detail
.• ` a � "
FL #
FL9.777-R9
g
AUG 0 ;1 2911
Application Type
Revision
QE�'.J-ham
Code Version
2014
SL LLICic
Application Status
Approved
Comments
Archived �Q
ST. LUCrE CO M. LJILDC Dii ISIO
REVIEWED FOR COWL ME
Product Manufacturer Owens tornftVIE`r'�rEu` BjY
Address/Phone/Email One Owens.IIg Parkway �(�
Toledo,. OHS �*D PF� RiUST BE KEPT ON JOB
greg.) eele, �,Q QgkC.1O�i WILL BE MADE.
greg.keeler o, e
Authorized Signature, Greg keeler
greg.keeler@owenscorning.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
THESE PLANS AND ALL PROPOSED WORK
Address/Phone/Email
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS, THAT
MAY BE NECESSARY IN ORDER TO
Category
Roofing
COMPLY WITH ALL APPLICABLE CODES.
Subcategory
Underlayments
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed F
Professional Engineer
-= Evaluation Report -
Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
CONCEALED FASTENERS OR ATTACHMENTS
Evaluation Report
Florida. License
PE-74021.
ARE THE RESPONSIBILITY OF THE
Quality Assurance Entity
UL LLC
CONTRACTOR OF RECORD
Quality Assurance Contract Expiration Date
12/31/20' 0
Validated By
Locke Bowden
✓.. Validation Checklist
- Hardcopy Received
Certificate of independence
FL9777 R9 COI OCR14002
6a FBC 2014 Evaluation Report W athe
Non-HVHZ FINAL.odf
Referenced Standard and Year (of Standard)
Standard
Year
ASTM 'D i.970
2009
ASTM D 226
20,06
ASTM G,155
FILE
2005
®
UL'1897
12004
Equivalence of Product Standards
I �
Certified By
Sections from the Code
Product. Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summa :of Products
Method 1 Option D
04/12/2017
04/12/2017
04/13/2017
06/13/2017
FL #
Model, Number or Name
Description
9777.1
Weatherlock G
Weatherproofing Underlayment
Limits of Use.
Installation Instructions
Approved for use in HVHZ:. No
FL9777 R9 II OCR14002 6a FBC 2014 Evaluation Reoor
Approved for use outside HVHZ: Yes
Weatherlock Non-HVHZ FINAL.bdf
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A.
Created by Independent Third Party: Yes
` Other: See evaluation report for limits of use.
Evaluation Reports-
FL9777 R9 AE OCR14002.6a FBC 2014 Eval� iatinn R_o_nn
Weatherlock Non-HVHZ FINAL.odf
Created by Independent Third Party: Yes
9777.2
Weatherlock G (High Tear)
Weatherproofing Underlayment
Limits of Use.
Installation instructions
Approved for use in HVHZ:: No
Approved for use outside. HVHZ: Yes
FL9777 R9 If OCR14002.6a FBC 2014 Evaluation Repo
Weatherlock -Non-HVHZ FINAL.Ddf
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation. report for limits of use.
.Evaluation Reports
FL9777 R9 AE OCR14002.6a FBC 2014 Evaluation Repn
Weatherlock Non-HVHZ 'FINAL.DdF
l
Created by Independent Third Party: Yes
9777.3
Weatherlock MAT
Waterproofing Underlayment
Limits of Use.
Installation Instructions
Approved for use in HVHZ: Yes
.Approved for use outside-HVHZ: No
FL9777 R9 I1 OCRI4002,6b FB'C 2014 Evaluation Repor
Weatherlock HVHZ.pdf
Impact Resistant: N/A
Verified By:. Zachary. R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
' Other: See evaluation report for limits of use.
Evaluation Reports
IFL9777
f
�R9 AE OCR1400 :6b FRG' 2014 Evaluation Repc
Weatherlock HVHZ.pdf
Created by Independent Third Party: Yes -
9777.4-
Weatherlock MAT,
i .Waterproofing Underlayment
Limits of Use
Installation Instructions
Approved for..use in HVHZ: No
Approved for use. outside HVHZ: Yes
FL977 R9 II OCA14002 6a FBC 2014 Evaluation Repor
Weatherlock Non-HVHZ FINAL.odf
Impact Resistant: N/A
Design Pressure: N/A
Verified By: Zachary R. Priest 74021
'Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluatlon Reports
F197T7 R9 AE OCR14002.6a FRr 2014 Evaluation Repo
Weatherlock Non-HVHZ FINAL.pdf
•
Created by Independent Third Party: Yes
9777-5;
�WeatherLock, Metal
Weatherproofing Underlayment
Limits of. Use
Approved for use in HVHZ: No
Approved for use outside. HVHZ: Yes .
Impact Resistant: N/A
:Installation Instructions
FL9777 R9 Ih OCR14002 6a FBC 2014 Evaluation Reoor
Weatherlock Non-HVHZ FINAL.pdf
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Other: See evaluation report for limits of use.
Created :by Independent Third Party: Yes
Evaluation Reports
171-97`d7 129 AE OCR14002.6a FBC 2014 Evaluation Rep
'
Weatherlock Non-HVHZ FINAL.pdf
Created by Independent Third Party: Yes
9777,6
Weatherl-ock Metal
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
FL9777 R9 11 OCR14002.6b FBC 2014 Evaluation Reoor
Weatherlock HVHZ.adf
Impact Resistant: N/A
Verified By.; Zachary R. Priest PE-74021
Design.Pressure: N/A
Created bV IndependentThird.Party: Yes
Other: See evaluation, report for limits of use.
Evaluation Reports
FL9777- R9 AE 0014002 6b FBC 2014Evaluation Rep
Weathercock HVHZ.pdf.
9777.7 �eatherLock Specialty Tile & Metal
Created by Independent Third,Party: Yes
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777 R9 :Ii OCRI4002.6a FBC 2014 Evaluation Repo
Vlleatherlock Non-HVHZ FINAL Ddf;
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R:, Priest74021
Design Pressure: +0/-105
Other-: See evaluation report for limits of use.
Created by Independent Third Party -:Yes
Evaluation Reports
FL9777 R9 AE OCR14002 6a FBC 2014 Evaluation Repo
Weathercock Non-HVHZ FINAL.pdf
Created by Independent'Third Party, Yes
BacFc IGextl
Contact Us :: 2601 Blair Stone Road: Tallahassee Fl.32399.Phone: 850-4874824
The State of Florida is an AA/EEO employer. Coovriaht 2007-2013-State of Florida.:: Privacy Statement -.: Accessibility Statement,: fiefund Statement
i
Under Florida law, email addresses are public-records.'If you.do not want your a -mall address released in response to a public -records request, do not send ele
mail to, this entity. Instead, contact the office by phone or by traditional, mail, If you have any, questions, please contact 850.497.1395. 'Pursuant to Secti
4S5.275(1),_Florida Statutes, effective October 1, 2012i licensees licensed under Chapter AtS, F.S. must provide the Department with -an email address if the,
one. The emalls provtded may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply F
address, please provide the Department with.an emalf address which can be made'available to the public. To determine](you are a Ilcensee.under.Chapter 45.
please click her-L.
Product Approval Accepto
Credit Card
Safe
7
.Certificate of Authorization No. 29824
CREEK
17520 Edinburgh Drive
Tampa, FL.33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE. W" EDITION
Manufacturer:
OWENS CORNING ROOFING AND ASPHALT LLC Issued April 12, 20'17
1 Owens Corning; Parkway
Toledo, OH 43657
(800) 438-7465
www.owenscorning.com
Manufacturing Location:
Brentwood, NH
Houston, TX
Quality Assurance:
UL LLC (QUA9625)
SCOPE
Category:
Roofing
Subcategory.:
Underlayments
Code Sections:
1504.3.1,1507:2.4, 1507.2.8, 1507.2.9.2; 1507.13; 1507.4.5, 1507.4.5:2, 1507.5.3;
1507.5.3.2, 1507.7.3', 1507.7.3.2
Properties:
Physical properties
REFERENCES
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST6049)
NEI-039.-02-01
ASTM D 1970
2009
PRI Construction Materials Technologies (TST6049)
NEI-042-02r01REV2
ASTM 1T1970
2009
PRI Construction Materials Technologies (TST6049)
NEI-045-02-01
TAS 103
1995
PRI Construction,,Materials'Technologies (TST6049)
NEI-045-02-01
ASTM G 155
2005a
PRI ,Construction Materials Technologies (TST6049)
NEI-053=02-01
TAS 103,
1995
PRI Construction Materials Technologies (TST6049)
NEI-053-02-01
ASTM G`155
2005a
PRI Construction Materials Technologies' .049) ,
NEt-093-02-02
ASTM D 1976
2009
PRI Construction Materials Technologies,(fST6049) '
OCF-213=02-01
ASTM D 1623
2009
PRI Construction Materials Technoiogies•(LST6049).
OCF-237-02-01
UL 1897
2004
PRI Constriction MaterialsTechnologies (TST5878)
OCF-252-02-01
ASTM D 4798
2001
PRI Construction Materials Technologies (TST6049)
OCF-252-02-01
ASTM D 1970
2009
PRI Construction Materials Technologies (TST5878)
OCF-253-02-02
ASTM D 1970
2009
PRI Constructfort.Materials Technologies (TST6049)
OCF272,02-01
TAS 103
1995
PRI Construction Materials Technologies (TST6049)
OCF-29fr02-02
ICC-ES AC 188'
2012
ICC-ES AC 48
2012
PRI.Construction Materials Technologies (,5T6049)
OCF-297-02=01.1
ASTM D 1970
2009
'Determined to be equivalent to ASTM D 226-06i Type I and.11
t
FL9777-R9 Page 1 of 4
This evaluation -report 1s provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, I;LC of.any product changes or quality assurance changes throughout the duration for which this report is valid..
This evaluation report does not express nor -Imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed. herein,
CREEK
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
OWENS CORNING -ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barriers
WeatherLock@-G
WeatherLock@: G is an ASTM. D 1970 self-adhesive underlayment constructed. from SBS
(Brentwood, NH)
modified asphalt, a fiberglass- mat reinforcement and surfaced with granules. The
product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x.66.7-ft.
WeatherLock@ 'G is permitted to be. used with .mechanically fastened asphalt shingles,
wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
WeatherLock® Mat
WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood,. NH or
SBS modified asphaltwith a fiberglass mat reinforcement. The product is supplied in 1-
Houston, TX)
sq. rolls with nominal dimensions of 3-ft x 33:3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLock@ Mat is permitted, to be used with mechanically fastened asphalt shingles,
wood shakes or shingles, and slate. roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
WeatherLock® Metal
WeatherLock® Metal is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood' NH)
SBS modified asphalt with a ,fiberglass, mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. rolls with nominal dimensions of 3=ft x 66.7-ft.
WeatherLockO Metal' is permitted -to be::used with mechanically 'fastened asphalt
shingles, metal roof.panels or shingles,. wood shakes or shingles, and slate roofing as
prescribed 'in the FBC. Exposure on the roof deck shall be limited to a maximum 90
days.
WeatherLock@
WeatherLock® Specialty Tile' &. Metal is an ASTM D 1970 self-adhesive underlayment
Specialty Tile &.Metal
constructed from SBS, rhodified, asphalt and surfaced with a, non -woven polyester. fabric.
(Brentwood,.NH)
The product is.supplied in 2.14 sq. rolls,with nominal dimensions_of 36ft x 71.3-ft.
WeatherLock® Specialty Tile &Metal is permitted to. be used with mechanically fastened
asphalt shingles, clay or concrete tile; metal. roof panels or shingles, wood -shakes or
shingles,,and. slate roofing as prescribed in,the FBC.. WeatherLock@SpecialtyTile &
Metal is permitted to be used with adhered clay.or concrete the roofing using either 3MTM
2-Component Foam Roof Tile Adhesive AH-160 (3M Company) or TILE BONDTM Roof
Tile. Adhesive. (The Dow Chemical. Company,), Exposure -on the roof.deck shall be -limited'
to a. maximum 90 days.
The maximum roof slope shall be-6:1.2•when ,used. with clay or concrete file installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
WeatherLock@ G (High
1(VgatherLock0 G (High Tear) is a: self -adhered, ,underlayment used as an alternative to
Tear)
ASTM IJ 226, Type I or -Type II roofing felt and AS D 1910 self -adhering polymer
(Houston, 7X) .
modified bitumen underlayment. The underlayment is composed of SBS modified,
asphalt with, a fiberglass mat, interpal reinforcement and is -surfaced with granules.:The
product is supplied. with a norninal thickness. of 50 mils in 1:.95-s4 rolls with nominal
dimensions of 34 x 654
WeatherLocke G (High Tear)' is,permitted,to be:use�d'with mechanically fastened asphalt
shingles, metal roofing; slate shingles, wood shingles and wood, shakes as prescribed in
the.FBC. Exposure on the roof deck shall be' limited to a maximum 30 days.
OCR14002.6a
FL977,7{k9 Page 2 of 4
This evaluation report is provided for State of'Flonda product approval; under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes_or quality assurance changes thioughout the -duration for which this report is valid.
This evaluation report does not express nor imply warranty,, installation, recommended use, or other product attributes•that are not
specifically addressed. herein.
s
t ;
C R E E OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing. ice & Water Barriers
TECHNICAL SERVICES, LLC
PRODUCT APPLICATION
Min. Roof Slope: 2:12 or in accordance in with the FBC
Application: All underlayments shall be installed in accordance with the FBC.
Deck substrates s all be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the underlayment shallbe. unrolled and
allowed to relax for a minimum of 3-5 minutes.
The undedayment shall be installed with the release backer removed and pressed firmly
into place'to ensure complete contact with the deck. The undedayment shall be installed
with the roll length parallel to the eave, starting at the eave, and with minimum 3" sid'e.
laps and minimum 6" end laps staggered min'. 64from preceding course. Additionally,. if
-applying. WeatherLock® Specialty Tile & Metal, end laps shall be. primed with ASTM D
41 primer or sealed. with asphalt roof :cement a minimum of 3-4 inches across the width
of the lap.
It is permissible to back nail the undedayment 12-inches on -center as needed, (nails shall
be .installed perpendicular to deck, with the nail heads flush to the. top surface ' of the
undedayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed
when'installed on roof slopes greater than 3:.12. ,
Min. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application -temperature.
WIND RESISTANCE
The Maximum 'Design Pressures shown below were, calculated using a 2:1 'margin of safety per FBC Section,1504.9.
Underlayment Svstem No.1 — WeatherLock:Soecialty Tile & •Metal Oniv `
Roof Deck: Min: '15/32=lnch-CDX plywood; attached.to wood, supports spaced a maximum 24" o.c.
Undedayment:: WeatherLock® Specialty Tile & ' Metaf shall be applied in accordance with
manufacturer's installation instructions.Xo; the fastened deck and. backnailed along the
selvage with.minimum 129a:, I 'l/4-in5h;lva ganized . ring shank roofing nails through
optionally primed, 329a. x 1 5i8-inch 0 tin caps spaced •12" o:c.. The applied
underlaymenf shall, be rolled with a minimum?. 7i516`steel roller immediately following
application.
Maximum Design -1.05 psf
.Pressure:
OCR14002.6a 171-9777-R9 Page 3 of 4
This evaluation. report is provided for State of Florida product approval, under Rule 61G20-G. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes orquality, assurance changes throughout the duration for which this.report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
- CREEK
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS
i !
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock(&Self-Sealing Ice & Water Barriers
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the -scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for newor existing construction.
5) The space under the deck area shall be properly ventilafed in accordance with the'FBC requirements.
6) All side lap seams -shall be installed to shed water from the: deck.
7) The underlayment, may be used: as described. in other current FBC product approval documents.
8) Design wind load pressures shall. be determined for components and cladding in accordance with FBC
1609..
9) The roof deck shall be designed by others in accordance with FBCrequirements to resist thedesign wind
load pressures for components and cladding.
10) Maximum Design 'Pressures for a given undedayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) .All products listed'in this report shall be. manufactured undera quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products: evaluated herein by Zachary. R. Priest, P.E. have -demonstrated compliance with the, Florida Building
Code 5th Edition (2014) as evidenced in the referenced documents submitted by the named manufacturer.
�� RY R.
�'' 2017.04.12
4 *; No 74021 :* 151546
0 STATE OF 4U Z '04f00
f.
` 4S
G O R t O P "' , Zachary R. Priest, P.E.
on No. 74
bNA� , OrganFlorida ationNo�ANE9641021:
CERTIFICATION OF INDEPENDENCE
i . I . , ,
CREEK Technical Services,.LLC does not have,, nor will it.acquire, a financial interest in any company manufacturing or distributing
products undeothis evaluation. !
CREEK Technical Services, t,LC is not owned, operated, orcontrolled by -any company manufacturing or distributing products under
.this evaluation. { 1 • i '
Zachary R. Priest, P.E. does not have,, nor will acquire, a financial interest In -any company manufacturing or distributing products
undenthis evaluation.
Zachary R. Priest, P.E. does not'have, nor will acquire, a financial, interest in any other entity involved in the approval process of the
product. i
END OF REPORT
OCR14002.6a FL9777-R9 I Page 4 of 4
This evaluation report is provided for State of, Florida product approval under Rule 61.G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes orquality assurance changes.throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.