Loading...
HomeMy WebLinkAboutNotice Of Product CertificationNOTICE OF PRODUCT CERTIFICATION w 1f ECEIVED AUG 0 J 2017 CERTIFICATION NO: DATE: CERTIFICATION PROGRAM: COMPANY: CODE: REVISION DATE: NI011567.02-R2 05/23/2013 Structural JELD-WEN 1822-1 01/13/2017 To verify that the "Notice of Product Certification" is valid, please visit www.NAMICertification.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION JELD-WEN "Premium Atlantic Vinyl Single Hung" 3737 Lakeport Boulevard Impact Rated Vinyl Single Hung Window Klamath Falls, OR 97601 (Fin & Flange Installation) Configuration: O/X Glazing: IG-1/8" Annealed Glass/Laminate- 1/8" Annealed Glass/0.090" SentryGlas® Plus Interlayer by DuPont/l/8" Annealed Glass or IG-1/8" Annealed Glass/Laminate-1/8" Annealed Glass/0.090" PVB by DuPont/l/8" Annealed Glass Frame: W-1324mm(52.13") H-1905mm(75") Sash: W-1254mm(49.38") H-946mm(37.25") SPECIFICATION .PRODUCT RATING TAS 201/202/203-94 Design Pressure: +50/-60 psf Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories Report No: NCTL-210-3874-1 Expiration Date: April 30, 2025 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 FRDY CDRIE113 A Ym3MN T� HN YmSPAN4 WBODW WIDTH (52 Ile MAX) TYPICAL ELEVATION WITH FASTENER SPACING o.c. �IN t' YA1I. FRDY Installation Notes: 1. Seal flange/frame to substrate. 2. Use #10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 1/2" into the wood framing. For 2X wood frame substrate (min. S.G. = 0.42). 3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document Date: 2014.09.1916:25:32-04'00' This schedule addresses only the fasteners required to anchor the / window to achieve the rated design pressure up to the size limitations 111—/2' MIEN. EMBEDMENT 9I / �2X WOOD FRAME MIN. DISTANCE FOR EDGE: 3/4" GLAZING DETAIL FRAME SECTION (TYP) VERTICAL SECTION WTE: C"dkW—n WOM Fimge d Wood 0, } MIN. DISTANCE FOR EDGE: 3/4' WOOD FRAME NAIL FIN INSTALLATION MIN. DISTANCE FOR EDGE: 3/4" 2X WOOD i FRAME i 1/4" MAX i SHIM SPACE 11/2" MIN. EMBEDMENT I 1 JAMB SECTION (TYP) HORIZONTAL SECTION NOTE: Coelk bet— Nailing Flmge A Wand Opening. PREMIUM ATLANTIC VINYL SH WINDOW Max Frame DP RATING IMPACT 52 1/8 x 75 +50/-60 YES LARGE MISSILE IMPACT General Notes: 1. The product shown herein is designed, tested -and manufactured to comply with the wind load criteria of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida Building Code (FBC) including HVHZ and the industry requirement for the stated conditions. 2. All glazing shall conform to ASTM E1300. 3. At minimum, glazing is 3mm annealed -11 mm airspace - 3mm annealed - 2mm PVB Intedayer by DuPont - 3mm annealed. 4. Use structural or composite shims where required. noted. It is not intended as a guide to the installation process and does �� �� PRWECT ENGINEER: DATE: not address he sealing consideration that may arise in different wall �� e• �` �� ` ••••• •• " �' �� -- 08/13/2014 Lakeport Blvd conditions. For the complete installation procedure, see the instructions ��; �,� DRAWN BY: SCAIP: Klamath Falls, OR. 976oi JELDVEN th F packaged with the window or go to : ~ 7 D. Vezo NTS Phone: (541) 882-3451 CHECKED BY: J. KED BY: tola TITLE: www.jeld-wen.com/resourcesAnstallafion. _ * * 0: = �: Premium Atlantic Vinyl Impact Single Hung Window APPROVED BY: DISCLAIMER: �J (V This drawing and its contents are confidential and are not to be . O,n '•. C Dp' •' �: ��� P�Rr�P�oE�g U reproduced or copied in whole or in part or used or disclosed to others P.E. N IDENTIFIER No. NCTL210-3874- PLANT NAME AND LOCATION: -FBC CAD DWG. No.: REV: 00 SHEET IOF3 except as authorized by JELD WEN Inc. aea D to 33e n 111 M MAL HERS 1EA• o.C. MAX. TM JAN11 FROM CORNERS --WINDOW N701H (52 I/V MAX.) TYPICAL ELEVATION WITH FASTENER SPACING Installation Notes: 1. Seal flange/frame to substrate. 2. Use 3/16" ITW Tapcon or equivalent fasteners through frame with sufficient length to penetrate a minimum of 11/4" into concrete or masonry at each location with a 21/2" min from edge distance. For concrete (min. Pc = 3000psi) or masonry substrate (CMU shall adhere to ASTM C90). 3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. This schedule addresses only the fasteners required to anchor the window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does not address he sealing consideration that may arise in different wall conditions. For the complete installation procedure, see the instructions .; packaged with the window or go to www.jeld-wen.com/resourcesAnstallation. DISCLAIMER: This drawing and its contents are confidential and are not to be reproduced or copied in whole or in part or used or disclosed to others except as authorized by JELD-WEN Inc. see El MM DISTANCE FOR EDGE: 21/7 2 Q4'. MAsomy BLOCK a v 3 11/4' MM EMBEDMENT —1/4' MAX S1OM SPACE zmm zmm 3mm 3mm 6LAZING DETAIL FRAME SECTION (TYP) VERTICAL SECTION SOM SPACE Jr24 IV4MMEMB MENT TMASONRY A BLACK MASONRY INSTALLATION 11/4' MIN. EMBEDMENT 1/4' MAX a 3 SHIM SPACE MIN. DISTANCE V V FOR ED6E: 21/2' Q 'l MASONRY BLOCK 01 JAMB SECTION (TYP) HORIZONTAL SECTION PREMIUM ATLANTIC VINYL SH WINDOW Max Frame I DP RATING IMPACT 52 1/8 x 75 1 +50/-60 1 YES ��-MREWE:2NCE 1/T FOR EDGE: LARGE MISSILE IMPACT General Notes: 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida Building Code (FBC) including HVHZ and the industry requirement for the stated conditions. 2. All glazing shall conform to ASTM El300. 3. At minimum, glazing is 3mm annealed -11 mm airspace - 3mm annealed - 2mm PVB Interlayer by DuPont - 3mm annealed. 4. Use structural or composite shims where required. �tj�`�•••• v �j, PROJECT ENGINEER: r • �'� • - p� D Vezo 7 _ - CHECKED BY; J. Kantola T T fY APPROVED BY: AA . xox�ne�i� . 6 7qq7 1^ P.E. No a IDENTIFIER No. NCTL210-3874- to 338 a DATE` 08/13/2014 jEL]WWEN 3737 Lakeport Blvd 5�,8; Klamath Falls, Blvd NTS I Phone: (541) 882-3451 Premium Atlantic Vinyl Impact Single Hung Window AND LOCATION: I CAD DWG. No.: I REV. 00 I SHEET 20F3 C 14" OR. MAX. 1NRU JAMB WINDOW W811N (82 1/8' MAXI TYPICAL ELEVATION WITH FASTENER SPACING MAX. 4.8' MAX. FROM CORNERS Installation Notes: 1. Seal flange/frame to substrate. 2. For anchoring into metal framing use #8 TEK Self Tapping screws with sufficient length to achieve a minimum embedment of three threads past the frame thickness. Steel substrate min.18ga., fy = 33 ksi. 3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. This schedule addresses only the fasteners required to anchor the window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does not address he sealing consideration that may arise in different wall conditions. For the complete installation procedure, see the instructions packaged with the window or go to www.jeld-wen.com/resources/installation. DISCLAIMER: This drawing and its contents are confidential and are not to be reproduced or copied in whole or in part or used or disclosed to others except as authorized by JELD-WEN Inc. , `Q t 17 A, MIN. DISTANCE FOR EDGE: 1/2° 4j./4" in. embedment f three threads st frame 18 gauge min Steel Stud MAX SPACE zmm 2mm 3mm 3mm BITE GLAZING DETAIL FRAME SECTION (TYP) VERTICAL SECTION WMC e.b. Wn FWq aWm ow—i op— 1/45 MAX SHIM SPACE 18 gauge min Steel Stud of three threads past MIN. DIS DISTANCE FOR EDGE: 1/2° I i I 38 gauge min - Steel Stud I i MIN. DISTANCE C FOR EDGE: 1/2" I Min. embedment of three threads Past frame STEEL INSTALLATION 1/4" MAX SHIM SPACE JAMB SECTION (TYP) HORIZONTAL SECTION PREMIUM ATLANTIC VINYL 5H WINDOW Max Frame DP RATING IMPACT 52 1/8 x 75 +50/-60 1 YE5 LARGE MI55ILE IMPACT General Notes: 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida Building Code (FBC) including HVHZ and the industry requirement for the stated conditions. 2. All glazing shall conform to ASTM E1300. 3. At minimum, glazing is 3mm annealed -11 mm airspace - 3mm annealed - 2mm PVB Intedayer by DuPont - 3mm annealed. 4. Use structural or composite shims where required. PROJECT ENGINEER: DATE: 08/3737 Lakeport Blvd -- 13/2014 . DRAWN 8Y: SCALE: JELWWENKJamath Falls, OR. 97601 D. Vezo NTS Phone: (541) 882-3451 J. BY: - I Premium Atlantic Vinyl Impact Single Hung Window AND LOCATION: 00 ��3 OF 3 Fla BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 JELD-WEN, Inc. 398 E. Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Premium Atlantic Vinyl Single Hung - Impact for Florida Product Approval Current Florida Building Code Method: 1— A (Certificate) Category: Windows Sub — Category: Single Hung Product: Premium Atlantic Vinyl Single Hung - Impact Material: PVC Product Dimensions: 52-118" x 75" (OIX) Prepared For: r JELD-WEN,1nc. 3737 Lakeport Blvd. Klamath Falls, OR 97601 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Q-�,.•• " • ••�`���i Date:08/11/2014 �'ZZ : p 7 _ Contents: _ 7k Evaluation Report Pages 1— 4 'b T T x :per-�•• �0 DP•• ��� Digitally signed by Hermes F. Norero, P.& 1 Reason: I am approving this document ''��ON� Date: 2014.09.19 16:31:16 -04 00 Hermes F. Norero, P.E. Florida No. 73778 ral Manufacturer: BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 JELD-WEN, Inc. Product Category: Product Sub -Category: Compliance Method: Product Name: Windows Single Hung State Product Approval Method (1)(a) Premium Atlantic Vinyl Single Hung - Impact 52-1/8" x 75" (O/X) Date: 08/11/2014 Report No: 3091 Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for JELD-WEN, Inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions NCTL210-3874-1-FBC, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing NCTL210-3874-1-FBC require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions NCTL210-3874-1-FBC for size and design pressure. limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 4 BUILDING DROPS Date: 0014 Report Noo:: 3091 A Perfect Solution in Every Drop Certificate of Authorization: 29578 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization #: QUA 1789) Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories NW (FBC Organization # TST9341) Report #: NCTL-210-3874-1, Report Date: 4/18/2013 2. Certification Agency National Accreditation and Management Institute (FBC Organization #: CER 1773) 3. Material Certification Miami Dade RER —Product Control Section NOA E.I. DuPont De Nemours & Co., Inc.: PVB Interlayer 4. Material Certification Miami Dade RER — Product Control Section NOA Quanex Building Products: PVC Extrusions 1. Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 4 • Date: 0o: 30014 BUILDING DROPS Report No: 91 A Perfect Solution in Every Drop Certificate of Authorization: 29578 Through Frame Installation: 1. Approved anchor types and substrates areas follows: A. For concrete (Min. fc = 3000 psi) or masonry substrate (Min. fc = 1500 psi) where one by (1X), non-structural, wood bucking is employed, use (1) 3/16" diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete.or masonry. B. For concrete (Min. fc = 3000 psi) or masonry substrate (Min. fc = 1500 psi) where wood bucking is NOT employed, use (1) 3/16" diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For steel substrate, use (1) #8 Tek Screw type steel frame (min. 18ga.) anchors per location of sufficient length to achieve minimum three threads of penetration beyond steel structure. Nail Fin Installation (Where applicable): A. For wood substrates (Min. S.G. = 0.42) use (1) #10 Wood Screw type installation anchors per location of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. Refer to Installation Instructions (NCTL210-3874-1-FBC) for anchor spacing and more details of the installation requirements. Design Pressure: Design Pressure Positive 50 PSF • Negative 60 PSF Hermes F. Norero, P.E. Florida No. 73778 Page 4 of 4 BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Product Ev.1 " : c.11 i a1 9 Report Of JELD-WEN, Inc. 398 E. Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Premium Atlantic Vinyl Single Hung - Impact fog' Florida Product Approval Current Florida Building Code Method: 1— A (Certificate) Category: Windows Sub — Category: Single Hung Product: Premium Atlantic Vinyl Single Hung - Impact Material: PVC Product Dimensions: 52418"x 75" (OIX) Prepared For: JFLD-WEN, Inc. 3737 Lakeport Bled. Klamath Falls, OR 97601 Prepared by: ```I%J11 i i rrri,,�i Hermes F. Norero, P.E.�.� ES F. Florida Professional Engineer # 73778 Q-� .•• " • �` ��i Date: 08/11/2014 ��;' 7 Contents: Evaluation Report Pages 1— 4 'fl T T CC Digitally signed by Hermes F. Norero, P. IFS ••'•••••••''•• C�N��`� Reason: I am approving this document i"�'S,�N; Date: 2014.09.19 16:31:16-04'00' Hermes F. Norero, P.E. Florida No. 73778 BUILDING DROPS �' A Perfect Solution in Every Drop Certificate of Authorization: 29578 Manufacturer: JELD-WEN, Inc. Product Category: Windows Product Sub -Category: Single Hung Date: 08/11/2014 Report No: 3091 Compliance Method: State Product Approval Method (1)(a) Product Name: Premium Atlantic Vinyl Single Hung - Impact 52-1/8" x 75" (O/X) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for JELD-WEN, Inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions NCTL210-3874-1-FBC, signed and sealed by Hermes F. Norero, P.E. (FL# 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing NCTL210-3874-1-FBC require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions NCTL210-3874-1-FBC for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 4 w r 7 • Date: 0o: 30014 BUILDING DROPS Report No: 91 A Perfect Solution in Every Drop • Certificate of Authorization: 29578 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization #: QUA 1789) Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories NW (FBC Organization # TST9341) Report #: NCTL-210-3874-1, Report Date: 4/18/2013 2. Certification Agency National Accreditation and Management Institute (FBC Organization #: CER 1773) 3. Material Certification Miami Dade RER — Product Control Section NOA E.I. DuPont De Nemours & Co., Inc.: PVB Interlayer 4. Material Certification Miami 'Dade RER — Product Control Section NOA Quanex Building Products: PVC Extrusions Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 4 y BUILDING DROPS Dater 0014 Report Noo:: 3091 A Perfect Solution in Every Drop • Certificate of Authorization: 29578 Through Frame Installation: 1. Approved anchor types and substrates areas follows: A. For concrete (Min. f'c = 3000 psi) or masonry substrate (Min. f'c = 1500 psi) where one by (1X), non-structural, wood bucking is employed, use (1) 3/16" diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. B. For concrete (Min. f'c = 3000 psi) or masonry substrate (Min. f'c = 1500 psi) where wood bucking is NOT employed, use (1) 3/16" diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For steel substrate, use (1) #8 Tek Screw type steel frame (min. 18ga.) anchors per location of sufficient length to achieve minimum three threads of penetration beyond steel structure. Nail Fin Installation (Where applicable): A. For wood substrates (Min. S.G. = 0.42) use (1) #10 Wood Screw type installation anchors per location of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. Refer to Installation Instructions (NCTL210-3874-1-FBC) for anchor spacing and more details of the installation requirements. Design Pressure: Design Pressure Positive 50 PSF Negative 60 PSF Hermes F. Norero, P.E. Florida No. 73778 Page 4 of 4