Loading...
HomeMy WebLinkAboutProduct Approval CasementFlorida Building Code Online CBCIS Home ( Log In User Registration Hot Topics I Submit Surcharge Stats & Facts Publications y FBC Staff BCIS Site Map Links i Search a .) Product Approval USER: P'. it. User db Product Approval Menu > Product or Application Search > Application List > Application Detail i' "l��" FL # FL13999-R7 Application Type Editorial Change ' Code Version 2014 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory 0 JELD-WEN 3737 Lakeport Blvd Klamath Falls, OR 97601 (800)535-3936 fbcl@jeld-wen.com Kaede McLaughlin fbcl@jeld-wen.com JELD-WEN Corporate Customer Service 3737 Lakeport Blvd. Klamath Fails, OR 97601 (800) 535-3936 customerserviceagents@jeld-wen.com Windows Casement Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute Referenced Standard and Year (of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Date Submitted Method 1 Option A 06/22/2017 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQ3Zsw6e 108... 8/10/2017 tt Florida Building Code Online Page 2 of 3 Date Validated Date Pending FBC Approval Date Approved Date Revised 07/24/2017 07/25/2017 07/27/2017 FL # Model, Number or Name Description 13999.1 Premium Atlantic Vinyl Casement (8700) 36" x 72" Insulated Glass (3/16 in - 3/16 out Annealed) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55/-65 Other: Miami -Dade NOAs: Quanex Building Products, Inc PVC (12-1017.02 and 13-0425.15). Certification Agency Certificate FL13999 R7 C CAC NI011746.01-R2.odf Quality Assurance Contract Expiration Date 12/31/2025 Installation Instructions FL13999 R7 II FL13999 R4 II DP55- 65 36x72 Installation Instructions.pdf Verified By: Hermes. Norero, PE 73778 Created by Independent Third Party: Yes Evaluation Reports FL13999 R7 AE FL13999 R4 AE PER2690.odF Created by Independent Third Party: Yes 13999.2 Premium Atlantic Vinyl Casement (8700) 36" x 62" Insulated Glass (1/8 in - 1/8 out Annealed) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55/-60 Other: Miami -Dade NOAs: Quanex Building Products, Inc PVC (12-1017.02 and 13-0425.15). Certification Agency Certificate FL13999 R7 C CAC NI011663-RI.odf Quality Assurance Contract Expiration Date 07/31/2025 Installation Instructions FL13999 R7 II DP55- 60 36x62 Installation Instructions.odf Verified By: Hermes Norero, PE 73778 Created by Independent Third Party: Yes Evaluation Reports FL13999 R7 AE PER3099.odf Created by Independent Third Party: Yes 13999.3 Premium Atlantic Vinyl Casement (8700) 36" x 72" Insulated Glass (5/16 SGP Lam in - 1/8 Annealed out) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-60 Other: These windows do not meet small missile impact wind-borne requirements as required by FBC, section 2411.3,3.7 when the exterior lite is annealed. These windows meet small missile impact wind-borne protection requirements as required by FBC, section 2411.3.3.7 when the exterior lite is tempered. Miami -Dade NOAs: Quanex Building Products, Inc PVC (12-1017.02 and 13-0425.15), Dupont SentryGlas Interlayer(11-0624.02). 13999.4 1 Premium Atlantic Vinyl Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: These windows do not meet small missile impact wind-borne requirements as required by FBC, section 2411.3.3.7 when the exterior lite is annealed. These windows meet small missile impact wind-borne protection requirements as required by FBC, section 2411.3.3.7 when the exterior lite is tempered. Miami -Dade. NOAs: Quanex Building Products, Inc PVC (12-1017.02 and 13-0425.15), Dupont PVB Interlayer (13-0129.27), Dupont SentryGlas Interlayer (11-0624.02). 13999.5 1 Premium Atlantic Vinyl Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-65 Certification Agency Certificate FL13999.R7 C CRC NI011660-Rl.odf Quality Assurance Contract Expiration Date 07/31/2025 Installation Instructions FL13999 R7 II DP55- 60 36x72 LMI Installation Instructions. odf Verified By: Hermes Norero, PE 73778 Created by Independent Third Party: Yes Evaluation Reports FL13999 R7 AE PER3098.0f Created by Independent Third Party: Yes Casement (8700) 36" x 72" Insulated Glass (5/16 PVB or SGP Lam in - 1/8 Annealed out) Certification Agency Certificate FL13999 R7 C CAC NI011661 01-R1.odf FL13999 R7 C CAC NI011661-Rl.odf Quality Assurance Contract Expiration Date 07/31/2025 Installation Instructions FL13999 R7 II DP- 50 36x72 LMI Installation Instructions.pd Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL13999 R7 AE PER3100.pdf Created by Independent Third Party: Yes Casement (8700) 36" x 72" Insulated Glass (5/16 SGP in - 3/16 Annealed out) Certification Agency Certificate FL13999 R7 C CAC NI011746-R1.Ddf Quality Assurance Contract Expiration Date 12/31/2025 Installation Instructions http://www.floridabuilding.org/pr/pr_app* CJ8... 8/10/2017 Florida Building Code Online a Page 3 of 3 Other: These windows do not meet small missile impact FL13999 R7 II DP55- wind-borne requirements as required by FBC, section 65 36x72 LMI Installation Instructions.Ddf 2411.3.3.7 when the exterior lite is annealed., These Verified By: Hermes Norero 73778 windows meet small missile impact wind-borne protection Created by Independent Third Party: Yes requirements as required by FBC, section 2411.3.3.7 when Evaluation Reports the exterior lite is tempered. Miami -Dade NOAs: Quanex FL13999 R7 AE PER2689.pdf Building Products, Inc PVC (12-1017.02 and 13-0425.15), Created by Independent Third Party: Yes • Dupont SentryGlas Interlayer (11-0624.02). back Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487 1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida. ::.Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public- records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here Product Approval Accepts: Cr6dittard Safe �:mSOG�LLiI� mA'� " http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQ3Zsw6e 1 CJ8... 8/10/2017 NOTICE OF PRODUCT CERTIFICATION C,EI1 D AUG p J 2017 CERTIFICATION NO: DATE: CERTIFICATION PROGRAM: COMPANY: CODE: REVISION DATE: NI011661.01-111 09/06/2013 Structural JELD-WEN 1822-1 06/10/2017 To verify that the "Notice of Product Certification" is valid, please visit www.NAMICertification.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION JELD-WEN "Premium Atlantic Vinyl 3737 Lakeport Boulevard Casement Window (Impact)" Klamath Falls, OR 97601 Vinyl Casement Window w/Fin or Flange Installation Configuration: X Glazing: IG-1/8" Annealed Glass/Laminate-1/8" Annealed Glass/0.090" DuPont SGP Interlayer/l/8" Annealed Glass Frame: W-914mm(36.00") H-1371mm(72.00") Vent: W-876mm(34.50") H-1301mm(70.50") DLO: W-762mm(30.00") H-1282mm(66.00") SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: 2394 Pa (50 psf) Negative Design Pressure: 2394 Pa (50 psf) Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories Report No: NCTL-210-3903-01 Expiration Date: July 31, 2025 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 NOTICE OF PRODUCT CERTIFICATION CERTIFICATION NO: DATE: CERTIFICATION PROGRAM: COMPANY: CODE: REVISION DATE: NI011661-R1 09/06/2013 Structural JELD-WEN 1822-1 06/10/2017 To verify that the "Notice of Product Certification" is valid, please visit www.NAMICertification.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION JELD-WEN "Premium Atlantic Vinyl 3737 Lakeport Boulevard Casement Window (Impact)" Klamath Falls, OR 97601 Vinyl Casement Window w/Fin or Flange Installation Configuration: X Glazing: IG-1/8" Annealed Glass/Laminate-1/8" Annealed Glass/0.090" DuPont PVB Interlayer/l/8" Annealed Glass Frame: W-914mm(36.00") H-1371mm(72.00") Vent: W-876mm(34.50") H-1301mm(70.50") DLO: W-762mm(30.00") H-1282mm(66.00") SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: 2394 Pa (50 psf) Negative Design Pressure: 2394 Pa (50 pst) Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories Report No: NCTL-210-3903-01 Expiration Date: July 31, 2025 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 I I I i I I i I I I I I I i WM W MAMN (36• MAX.) ! V 11 TYPICAL ELEVATION WITH FASTENER SPACING i I, Installation Notes: 1. Seal flange/frame to substrate. 2. Use #10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 1/2" into the wood framing. For 2X wood frame substrate (min. S.G. = 0.42). 3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document Date: 2013.10.28 18:42:40-04'00' This schedule addresses only the fasteners required to anchor the J1111 t t r 1111 window to achieve the rated design pressure up to the size limitations ��� "f noted. It is not intended as a guide to the installation process and does not address he sealing consideration that may arise in different wall ��� �Q- •.••' •' �` �i� conditions. For the complete installation procedure, see the instructions Zlo packaged with the window or go to 7 www.jeld-wen.com/resources/installation. NAIL FIN INSTALLATION 11/2�MIN. EMBEDMENT Il-2X WOOD FRAME MIN. DISTANCE FOR EDGE: 3/4" MIN. DISTANCE j FOR EDGE: 3/4" 3 I j 2X WOOD SHIM1 SPACE FRAME i 3 22.0 mm 2.0 mm 3.0 3.0 mm 3.0 mm W OW ORNING995 GLASS BITE: 13.0 mm r1 A-11 wrr.ri FRAME SECTION (T✓P) VERTICAL SECTION NwTE: C�N b•i.-m "•91,3 Fb,y. a w••a oR,uM. -1/4° MAX SHIM SPACE 3 MIN. DISTANCE FOR EDGE: 3/4" 2X WOOD FRAME i l/2" MIN. EMBEDMENT 1/4" MAX SHIM SPACE 11/2" MIN. �0� I EMBEDMENT fl ' JAMB SECTION (TYP) HORIZONTAL SECTION NOTE: fmlk b- — Wliy Flag- % Woad Op -mg. I ' PREMIUM ATLANTIC VINYL CASEMENT I Max Frame DP RATING IMPACT 36 x 72 +/-50 YES General Notes: 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida Building Code(FBC) including HVHZ and the industry requirement for the stated conditions. 2. All glazing shall conform to ASTM E1300. 3. At minimum, glazing is 3mm annealed -13mm airspace - 3mm annealed - 2mm PVB or SGP - 3mm annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind borne debris protection is mandated by local building code. 7. Maximum sizes are buck sizes and do not include fin or flange. PROJECT ENGINEER: DATE: 10/25/2013 3737 Lakeport Blvd DR JELDNENKlamathAwN eY: scaLE: Falls, OR. 97601 D. Vezo NTS Phone: (541) 882-3451 CHECKED BY: TITLE: J. Kantola DISCLAIMER: = -0 T T Ir APPROVED BY: This drawing and its contents are confidential and are not to be % �� ••'•. �P' �� reproduced or copied in whole or in part or used or disclosed to others ��i 0. as authorized y 9 except thd b JELD-WEN Inc. 39a >�yt BUB IDENTIFIER No. ilAnin 9 f�l!"7'I 71 n_71 Premium Atlantic Vinyl Impact Casement Window Nail Fin Installation (36" x 72") REV. oo ISHEET I OF4 II 5' YAX. FROM CORNERS 15' O.C. MAX. TRW i FRAME !I .I II MIN. DISTANCE 2.0 mm 3.0 mm Dow CORNING 995 GLAZING DETAIL FRAME SECTION (TYP) VERTICAL SECTION - - - - 2 WINDOW WIDTH (3e MAX.)-� TYPICAL ELEVATION WITH FASTENER SPACING MIN. DISTANCE FOR EDGE: 3/4" Installation Notes: 1. Seal flange/frame to substrate. 2. Use #10 PH or greater fastener though the frame with sufficient length to penetrate a minimum of 1 1/2" into the wood framing. For 2X wood frame substrate (min. S.G. = 0.42). 3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. This schedule addresses only the fasteners required to anchor the window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does not address he sealing consideration that may arise in different wall conditions. For the complete installation procedure, see the instructions Z packaged with the window or go to www.jeld-wen.com/resources/installation. DISCLAIMER: - -P This drawing and its contents are confidential and are not to be C reproduced or copied in whole or in part or used or disclosed to others 398 except as authorized by JELD-WEN Inc. 93MA GLASS BITE: 13.0 mm 11/2" MIN. EME I I I MIN. DISTAP FOR EDGE: 3 I THROUGH FRAME INSTALLATION JAMB SECTION (TYP) HORIZONTAL SECTION I � I PREMIUM ATLANTIC VINYL CASEMENT Max Frame I DP RATING IMPACT 36 x 72 1 +/-50 1 YES General Notes: 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida Building Code(FBC) including HVHZ and the industry requirement for the stated conditions. 2. All glazing shall conform to ASTM E1300. 3. At minimum, glazing is 3mm annealed -13mm airspace - 3mm annealed - 2mm PVB or SGP - 3mm annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind borne debris protection is mandated by local building code. 7. Maximum sizes are buck sizes and do not include fin or flange. PRO1ECrENGINEER: DATE: ..•.����i -- 10/25/2013 JEIMPhone:�ITEN 3737 Lakeport Blvd DRAWN BY: SCALE: Klamath Falls, OR. 97601 D. Vezo NTS (541) 882-3451 CHECKED BY: J. Kantola iZ Z APPROVED BY: Rd; �• � 10-3903- Premium Atlantic Vinyl Impact Casement Window Through Frame Installation (36" x 72") 00 IJ 20F4 2.0 mm 3.0 mm DOW CORNING 995 GLAZING DETAIL FRAME SECTION (TYP) VERTICAL SECTION IMIIWW HRDTH (Se MAX.) TYPICAL ELEVATION WITH FASTENER SPACING Installation Notes: 1. Seal flange/frame to substrate. 2. Use 3/16" Tapcon or equivalent fasteners through frame with sufficient length to penetrate a minimum of 1 1/4" into concrete or masonry at each location with a 21/2" min from edge distance. For concrete (min. fc = 3000psi) or masonry substrate (CMU shall adhere to ASTM C90). 3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. This schedule addresses only the fasteners required to anchor the window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does not address he sealing consideration that may arise in different wall conditions. For the complete installation procedure, see the instructions packaged with the window or go to www.jeld-wen.com/resources/installation. DISCLAIMER: This drawing and its contents are confidential and are not to be reproduced or copied in whole or in part or used or disclosed to others except as authorized by JELD-WEN Inc. , `c t C rA,,'��I. GLASS BITE: 13.0 mm 11/4' MIN. MI L DISTANC FOR EDGE: 21A MASONRY INSTALLATION PREMIUM ATLANTIC VINYL CASEMENT Max Frame I OP RATING IMPACT 36 x 72 1 +/-50 1 YES MIN. DISTANCE FOR EDGE: 21/2' General Notes: 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida Building Code(FBC) including HVHZ and the industry requirement for the stated conditions. 2. All glazing shall conform to ASTM El300. 3. At minimum, glazing is 3mm annealed -13mm airspace - 3mm annealed - 2mm PVB or SGP - 3mm annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind borne debris protection is mandated by local building code. 7. Maximum sizes are buck sizes and do not include fin or flange. PROJECrENGINEER: DATE: 10/25/2013 3737 Lakeport Blvd j DRAWN BY: SCALE: JMDVENKfamath Falls, OR. 97601 D. Vezo NTS Phone: (541) 882-3451 7 — * — r ' 40 999 CHECKED BY: J. Kantola TIRE: APPROVED BY: P✓TPV0�4JL IDENTIFIER No. NCTL210-3903- PLANT A-FE Premium Atlantic Vinyl Impact Casement Window Masonry Installation (36" x 72") AND LOCATION: I CAD DWG. No.: I REV. 001 SHEET 3 OF 4 I 398 East Dania Beach Blvd. BUILDING DROPS Suite338 Dania Beach, FL 33004 A Perfect Solution in Every Drop 954.399.8478 PH Certificate of Authorization: 29578 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report Of JELD-WEN, inc. Premium Atlantic Vinyl Casement Window for Florida Product Approval a ! C Current Florida Building Code Method: Category: Sub — Category: Product: Material: Product Dimensions: 1— A (Certification) Windows Casement Casement Window (Impact) PVC 36"x 72" (X) Prepared For: JELD-WEN, inc. 3737 Lakeport Blvd. Klamath Falls, OR. 97601 Prepared by: Hermes F. Norero, P.E. ��� g F. Florida Professional Engineer # 73778 �.%� ���.••• •• ��i� Date: 08/11/2014 ��: •�� • '• :'A� 7 _ Contents: Evaluation Report Pages 1— 4 -n T T x Digitally signed by Hermes F. Norero'o;..;•'••..,,•,,..••' G��'`�� Reason: 2014.09.22 13 51:22 this 04'OOument ��i,Ss';pN; ; �`%% Date Hermes F. Norero, P.E. Florida No. 73778 /( BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Manufacturer: Product Category: Product Sub -Category: Compliance Method: Product Name: JELD-WEN, inc. Windows Casement State Product Approval Method (1)(a) Casement Window 36 x 72" (X) Date: 08/11/2014 Report No: 3100 Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for JELD-WEN, inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions NCTL210-3903-1A-FBC, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the current Florida Building Code and does not require an impact resistant covering. 5. Site conditions that deviate from the details of drawing NCTL210-3903-1A-FBC require further engineering analysis by a licensed engineer or registered architect. 6. See Installation Instructions NCTL210-3903-1A-FBC for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 4 Y , I BUILDING DROPS A Certificate of Authorization: 29578 Report No: 3100 Perfect Solution in Every Drop Date: 08/11/2014 Certification Agency: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a Certification Agency through National Accreditation & Management Institute (FBC Organization #CER1773). Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS,202-94 • TAS 203-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories (FBC Organization # TST1589) Report #: NCTL-210-3903-01, Report Date: 07/29/2013 2. Certification Agency National Accreditation & Management Institute (FBC Organization #CER1773) 3. Material Certification Miami Dade RER — Product Control Section NOA E.I. DuPont De Nemours & Co., Inc.: SentryGlas Plus Interlayer 4. Material Certification Miami Dade RER — Product Control Section NOA E.I. DuPont De Nemours & Co., Inc.: PVB Interlayer 5. Material Certification _ Miami Dade RER — Product Control Section NOA Quanex Building Products: PVC Extrusions Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 4 BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Installation: 1. Approved anchor types and substrates areas follows: Nailing Fin Installation: Date: 08/11/2014 Report No: 3100 A. For two by (2X) wood frame substrate (Min. S.G. = 0.42), use #10 Wood Screw type wood frame anchors of sufficient length to achieve minimum embedment of 1.50" into wood framing. Through Frame Installation: A. For two by (2X) wood buck substrate (Min. S.G. = 0.42), use #10 Wood Screw type installation anchors of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. B. For concrete (Min. f c = 3000 psi) or masonry (Conforms to ASTM C90) substrate where one by (1X), non-structural, wood bucking is employed, use 3/16" diameter ITW Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For concrete (Min. fc = 3000 psi) or masonry (Conforms to ASTM C90) substrate where wood bucking is NOT employed, use 3/16" diameter ITW Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. D. For steel stud substrate (Min 18 Ga., Fy = 33 ksi), use #10 ITW TEK Screw type steel stud anchors of sufficient length to achieve minimum 3 threads penetration beyond steel structure. Refer to Installation Instructions (NCTL210-3903-1A-FBC) for anchor spacing and more details of the installation requirements. Design Pressure: Design Pressure Rating Positive 50 PSF Negative 50 PSF Hermes F. Norero, P.E. Florida No. 73778 Page 4 of 4 Florida wilding Code Online 40 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=w.. M �r BCIS Home ; Log In { User Registration Hot Topics Submit Surcharge Stats & Facts I Publications I FBe Staff BCIS Site Map f Links 1 Search i • db'or a" °i Product Approval 44 USER: Public User Product Approval Menu > Product or An Dlicahon Search > Anohcation List > Application Detail FL # FL13999-R7 Application Type Editorial Change Code Version 2014 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory JELD-WEN 3737 Lakeport Blvd Klamath Falls, OR 97601 (800) 535-3936 fbcl@jeld-wen,com Kaede McLaughlin fbcl@jeld-wen.com JELD-WEN Corporate Customer Service 3737 Lakeport Blvd. Klamath Falls, OR 97601 (800)535-3936 customerserviceagents@jeld-wen.com Windows Casement Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute Referenced Standard and Year (of Standard) Standard TAS 201 TAS 202 TAS 203 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Year 1994 1994 1994 1 of 3 08/08/2017 11:07 AM