Loading...
HomeMy WebLinkAboutEvaluation Reporti EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION '26 GA. 5V-CRIMP PANEL' FLORIDA BUILDING CODE 5TH EDITION (2014) FLORIDA PRODUCT APPROVAL FL 14645.2-R2 ROOFING METAL ROOFING shy ai (y �`"• ; Prepared For: etal Sales Manufacturing Corporation 545 South 31 Street, Suite 200 Louisville, KY 40202 Telephone: (502) 855-4300 Fax: (502) 8554290 Prepared By: Bala Sockalingam, PhA, P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (918) 493-3568 This report consists of Evaluation Report (3 Pages including cover) Installation Details (1 Page) Report No. C2010-2 Date: 3.27.15 ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COM REVIEWED BY DATE PLANS AND PE MIT MUST BE KEPT ON JOB OR _NO'INSPECTION WILL BE MADE ,,,�►1111111����, ,..%,,gpCKAC//�� ? ; No 62240 ; �Ar ;cc— �� � OF STATE S 9� 3.30,2Q1� ,F Manufacturer: Product Name: Panel Description: Materials: Deck Description: Deck Attachment: (Minimum) Underlayment: FL 14645.2-R2 C2010-2 3.27.15 Page 2 of 3 �Ivletal`Sal`eskManufacturing CorJ�oration 9 24".wide coverage with (5) 1/2" high ribs Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Min. 19/32" thick plywood for new and existing constructions. Designed and installed as per FBC 2014. 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. in the plywood field and edges Minimum underlayment as per FBC 2014 Section 1507.4.5.1 Slope: 1/2:12 or.greater in accordance with FBC 2014 Section 1507.4.2 yy Rj Ye � • ,i Y�i Design Uplift Pressure: 84.5 psf @ 'fastener spacing of 24" o.c. (Factor of Safety = 2) 131.3 psf @ fastener spacing of 18" o.c. 149.6 psf @ fastener spacing of 12 o.c. id Fastener Pattern: Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". At panel ends 6 fasteners per panel width. (4 located adjacent to ribs and 2 between ribs) At intermediate 4 fasteners per panel width. (4 located adjacent to ribs) Test Standards:. Roof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2014 Section 1-507.4 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design. The maximum support spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2014 Section 1505 and current .. approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. 6��QN:3ISI� 5V-CRIMP MIN. 2X_ WOOD RAFTER/JOIST/ TRUSS AT MAX. 24" O.C. PANEL FASTENER SPACING PER ALLOWABLE PRESSURE TABLE. DEUNES V OR #8 x 2"LONG WOOD SCREWS SPACED ® 6" O.C. IN THE FIELD & AT PLYWOOD EDGES FASTENER PATTERN AT INTERMEDIATE LOCATIONS SEE DETAIL 1 —� _ 24" MIN. 2X_ WOOD RAFTER/JOIST/ TRUSS AT MAX. 24" O.C. #9-16 OR #10-14 WOODSCREWS WITH SELF SEALING WASHER AT MAXIMUM SPACING OF 24".O:C. UNDERLAYMENT DETAIL 1 OR #8 x 2"VLONG WOOD SCREWS SPACED ® 6" O.C. IN THE FIELD & AT PLYWOOD EDGES FASTENER PATTERN AT PANEL ENDS TYPICAL PANEL INSTALLATION X-SECTION 5V-CRIMP MIN 26 GA. PLYWOOD 19/32" THICK (MIN.) .Mr K� ALLOWABLE UPLIFT PRESSURE FASTENER SPACING (IN) PRESSURE (PSF) 24 84.5 18 131.3 12 149.6 GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL. HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.017"). EFFECTIVE COVERING WIDTH OF PANEL = 24". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE,AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH:THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. a IX 0 0 N 0 Lucl LuO :3N 2 N�o w MyLo az o Lo i M Jm 9N 0 O 00 �ul r� Zw a i a CL cm z zp w W 1 OF 1