FL # FL14645-R2
Application Type Revision
Code Version 2014
Application Status Approved
publications ? FBC Staff i BC[S Site Map 1: Unks ; Search
E C Euit7D
NOV 2 ? 2017
PERMIT-TiNIG
St. Lucie County, FL
Comments
Archived
Product Manufacturer Metal Sales Manufacturing Corporation
Address/Phone/Email 545 South 3rd Street, Suite 200
Louisville, KY 40202
(812) 218-7342
dstermer@metaisales.us.com
Authorized Signature David Stermer
dstermer@metaisales.us.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address]Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
'� Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2020
validated By Yoosef Levi, P.E.
:rj Validation Checklist - Hardcopy Received
Certificate of Independence FL14645 R2 COI Certificatpladeaendence.odf
Referenced Standard and Year (of Standard) Standard Year
FM 4470 1992
TAS 125 2003
UL 1897 1998
UL 1897 2004
UL 580 1994
UL 580 2006
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect �e
FL14645 R2 EouiV TestEauivalentC2010 UL.od
Sections from the Code
http://www.flondabuilding.org/pr/pr app_dtl.aspx?param=wGEvxQwtDgsw8ZVNfe8A7... 4/25/2016
Florida Building Code Qnline
Page 2 of 4
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
03/31/2015
04/14/2015
04/18/2015
05/23/2015
FL # Model, Number or Name Description
14645.1 2.5" Corrugated Min. 26 ga., 21.33" wide coverage through fastened roof
panel over min. 19/32" thick plywood deck.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R2 II EvaluationReportC2010 1 odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-86.0 Evaluation Reports
Other: Uplift load of 82.3 psf at fastener spacing of 36" o.c. FL14645 R2 AE EvaluationReportC2010 i.pdf
and 86.0 psf at fastener spacing of 12" o.c. Created by Independent Third Party: Yes
14645.2
SV-Crimp
Min. 26 ga., 24 wide through fastened roof panel over min.
19132" thick plywood deck with fasteners through panel fiat.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL14645 R2 II EvaluationReoortC2010 2 pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-149.6
Evaluation Reports
Other: Uplift load of 84.5 psf at fastener spacing of 24"
FL14645 R2 AE Eva] uationReportC2010 2.pdf
o.c., 131.3 psf at fastener spacing of 18" o.c. and 149.6 psf
Created by Independent Third Party: Yes
at fastener spacing of 12" o.c.
14645.3 15V-Crimp 119/326 ga., 24P wide through fastened roof panel over min. hick plywood deck with fasteners through panel rib. I
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R2 II EvaluationReportC2010 3xdf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-196.75 Evaluation Reports
Other: Uplift load of 41.6 psf at fastener spacing of 36" FL14645 R2 AE EvaluationReportC2010 3.pdf
o.c., 74.8 psf at fastener spacing of 16" o.c. and 196.75 psf Created by Independent Third Party: Yes
at fastener spacing of 8" o.c.
14645.4 SV-Crimp Min. 26 ga., 24" wide through fastened roof panel over min.
15/32" thick plywood deck or 7/16" thick OSB with fasteners
through panel rib.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R2 II EvaluationReportC2010 4.pdf
Approved for use outside HVHZ: Yes Verified By: Baia Sockalingam PE 62240
Impact Resistant: NIA Created by Independent Third Party: Yes
Design Pressure: +N/A/-172.5 Evaluation Reports
Other: Uplift load of 30.0 psf at fastener spacing of 36" o.c. FL14645 R2 AE Eva, uationReoortC2010 4 odf
and 172.5. psf at fastener spacing of 6" o.c. Created by Independent Third Party: Yes
14645.8 Aluminum Classic Rib Nom. 0.032" thick, 36" wide, aluminum through fastened
roof panel over min. 15/32" thick plywood deck or 7/16"
thick OSB.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R2 II FvaluatlonReportC2010 5.pdf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-120 Evaluation Reports
Other: Uplift load of 30 psf at fastener spacing of 36" o.c. FL14645 R2 AE EvaluationReportC2010 5.pdf
and 120 psf at fastener spacing of 6" o.c. Created by Independent Third Party: Yes
14645.E I Aluminum Vertical Seam I pane o e3 mini 15/32"h thick plywood de k orck, 16" wide, aluminum i7/16' thickng seam OSB.of
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Installation Instructions
FL14645 R2 II EvaluationReportC2010 6.pdf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A7... 4/25/2016
Florida Building Code Online
Page 3 of 4
Design Pressure: +N/A/-97.05
Other: Uplift load of 41.55 psf at clip spacing of 36" ox.,
71.0 psf at clip spacing of 12" o.c. and 97.05 psf at dip
spacing of 12" o.c. with sidelap adhesive.
Evaluation Reports
FL14645 R2 AE EvaluationReportC2010 6.pdf
Created by Independent Third Party: Yes
14645.7 Aluminum Vertical Seam Nom. 0.032"thick, 16" wide, aluminum standing seam roof
panel over min. 19/32" thick plywood deck
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-162.0
Other: Uplift load of 41.55 psf at clip spacing of 36" o.c.,
100.2 psf at dip spacing of 12" o.c. and 162.0 psf at clip
spacing of 12" o.c. with support strap.
Installation Instructions
FL14645 R2 11 EvaluationReportC2010 7.odf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL14645 R2 AE FvaluationReportC2010 7.pdf
Created by Independent Third Party: Yes
14645.8
Classic Rib
Min. 26 ga., 36" wide through fastened roof panel .over min.
19/32"thick plywood deck.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL14645 R2 II EvaluationReportC2010 8.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-133.9
Evaluation Reports
Other: Uplift load of 74.8. psf at fastener spacing of 36"
FL14645 R2 AE Eva luationRep_ortC2010 8.pdf
o.c., 92.3 psf at fastener spacing of ZV o.c. and 133.9 psf
Created by Independent Third Party: Yes
at fastener spacing of 18" o.c.
14645.9
Classic Rib
Min. 29 ga., 36" wide through fastened roof panel over min.
7/16" thick OSB deck
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL14645 R2 II EvaluationReportC2010 9.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-135.0
Evaluation Reports
Other: Uplift load of 45 psf at fastener spacing of 24" o.c.
FL14645 R2 AE Eva IuationReoortC2010 9.pdf
and 135 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
14645.10
Classic Rib
Min. 29 ga., 36" wide through fastened roof panel over min.
15/32" thick plywood deck.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL14645 R2 II EvaluationReportC2010 10.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-138.5
Evaluation Reports
Other: Uplift load of 68.4 psf at fastener spacing of 24" o.c.
FL14645 R2 AE EvaluationReportC2010 10.pdf
and 138.5 psf at fastener spacing of 12" o.c.
Created by Independent Third Party: Yes
14645.11
Image II
Min. 26 ga., 16" wide concealed fastened roof panel over
min. 15132" thick plywood deck or 7/16" thick OSB.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL14645 R2 II EvaluationReportC2010 11.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N%A/-86.55
Evaluation Reports
Other: Uplift load of 20.75 psf at fastener spacing of 24"
FL14645 R2 AE EvaluationReportC2010 11.pdf
o.c., 63.50 psf at fastener spacing of 6" o.c. and 86.55 psf
Created by Independent Third Party: Yes
at fastener spacing of 6" o.c. with sidelap adhesive.
14645.12
PBR-Panel or R-Panel
Min. 26 ga., 36" wide through fastened roof panel over min.
15/32" thick plywood deck.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL14645 R2 II EvaluationReportC2010 12.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-131.0
Evaluation Reports
Other: Uplift load of 30.0 psf at fastener spacing of 48" o.c.
FL14645 R2 AE EvaluationReportC2010 12.pdf
and 131.0 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
14645.13
Pro -Panel II
Min. 29 ga., 36" wide through fastened roof panel over min.
15/32" thick plywood deck.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL14645 R2 I1 EvaluationReportC2010 13.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-71.5
Evaluation Reports
Other: Uplift load of 41.6 psf at fastener spacing of 24" o.c.
FL14645 R2 AE EvaluationReportC2010 13.pdf
and 71.5 psF at fastener spacing of 12" o.c.
Created by Independent Third Party: Yes
http://www.floridabuilding.orglprlpr_app_dtl. aspx?param=wGEVXQwtDgsw8ZVNfe8A7... 4/25/2016
Florida Building Code Online Page 4 of 4
Back Nod
Comet Us -.t. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Coovrtoht 2007-2013 State of Florida.:: Privacy StatemeRefund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 4SS, F.S., please dick bML.
Product Approval Accepts:
du
f0MH®
CrediE Vj�
http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A7... 4/25/2016
EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
126 GA. IMAGE 1I PANEL'
FLORIDA BUILDING CODE 5TH EDITION (2014)
FLORIDA PRODUCT APPROVAL
j FL 14645.11-R2
ROOFING
f METAL ROOFING
A
s
Prepared For:
Metal Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville, KY 40202
Telephoner (502) 8554,300
Fax: (502) 8554290
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Installation: Details (1 Page) ,+o`j9Sn me j��14 0
se
SF
NO 62240 ••��
pSTAIE OF
♦>O�% i
N LE o++
poles% `
3 .'3Q .201
Report No. C2010-11
Date: 3.27.15
FL 14645.11 R2
C2010-11
3.27.15
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: Image 11
Panel Description: Max. 16" wide coverage with 1" high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Deck Description: Min. 7/16" thick OSB or min. 15/32" thick Plywood for new and
existing constructions. Designed and installed as per FBC 2014.
Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c.
(Minimum) in the plywood field and edges
New Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1.
Required for new construction and optional for reroofing construction.
Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing
(Optional) construction only.
Slope: 2:12 or greater in accordance with FBC 2014 Section 1507.4.2
Allowable Uplift Load: 20.75 psf @ fastener spacing of 24" o.c
(Factor of Safety = 2) 63.50 psf @ fastener spacing of 6" ox
86.55 psf @ fastener spacing of 6" o.c with 3/8" bead adhesive in
panel sidelap
Fastener Pattern: 410 pancake head screws along panel seam. Fastener shall be of
sufficient length to penetrate through the deck a minimum of/4".
Sidelap Adhesive: Schnee -Morehead SM7108 Permathane adhesive
Test Standards: Roof assembly tested in accordance with LL580-94 (Rev 98) `Uplift
Resistance of Roof Assemblies' & UL1897-98 `Uplift Tests for Roof
Covering Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2014 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2014 Section 1505 and current
FL 14645.11: R2
C2010-11
3.27.15
Page 3 of 3
approved roofing materials directory or ASTM E108/UL790 report
from an accredited laboratory for fire ratings of this product.
Supporting Documents: UL580AMI 897 Test Reports
Farabaugh Engineering and Testing Inc
Project No. T176-11, Reporting Date 4/26/11
Project No. T26041, Reporting Date 8/15/11
ROOF PANEL
ROOF PANEL
EXISTING SHINGLES NEW UNDERLAYMENT -
SEE DETAIL 1 (OPTIONAL) (REQUIRED ONLY FOR
n \ NEW CONSTRUCTION)
MAX. 16"
J� I `MINIMUM ATTACHMENT:
EXISTING UNDERLAYMENT II /�\YI Bd x 2.5" LONG RING SHANK NAIL
(OPTIONAL) OR #8 x 2' LONG WOOD SCREWS
MIN. 2X_ WOOD RAFTER/JOIST/ SPACED ® 6' O.C. IN THE FIELD &
TRUSS AT MAX. 24" D.C. AT EDGES
FASTENING PATTERN 1
EXISTING SHINGLES NEW UNDERLAYMENT
SEE DETAIL 2 (OPTIONAL)(REQUIRED ONLY FOR ADHESIVE THE
\� \ NEW CONSTRUCTION) PANEL SIDELAP
n 1
PANEL FASTENER
SPACING PER ALLOWABLE
PRESSURE TABLE.
OS8 7/16' THICK (MIN.) OR
PLYWOOD 15/32 THICK (MIN.)
kMIN.
EXISTING UNDERLAYMENT MINIMUM ATTACHMENT: PLYWOOD615/32K HICK)(M N.(OPTIONAL) 8d x 2.5" LONG RING SHANK NAIL 2X_ WOOD RAFTER/JOIST/ OR #8 x 2' LONG WOOD SCREWS
TRUSS AT MAX. 24' O.C. SPACED m 6' O.C. IN THE FIELD &
AT EDGES
FASTENING PATTERN 2
TYPICAL PANEL INSTALLATION X-SECTION
NEW UNDERLAYMENT-
(REQUIRED ONLY FOR
NEW CONSTRUCTION)
EXISTING SHINGLES
(OPTIONAL)
DETAIL 1
EXISTING UNDERLAYMENT —
(OPTIONAL)
NEW UNDERLAYMENT
(REQUIRED ONLY FOR
NEW CONSTRUCTION)
EXISTING SHINGLES
(OPTIONAL)
DETAIL 2
EXISTING UNDERLAYMENT
(OPTIONAL)
#10 PANCAKE SCREW
® MAX. 24' O.C.
MIN 26 GA.
OSB 7/16" THICK (MIN.) OR
PLYWOOD 15/32 THICK (MIN.)
SIDELAP ADHESIVE
NOM. 3/8" BEAD
#10 PANCAKE SCREW
® MAX. 6' O.C.
PANEL SIDELAP ADHESIVE
MIN 26 GA. LOCATION
OSB 7/16" THICK (MIN.) OR
PLYWOOD 15/32" THICK (MIN.)
ALLOWABLE UPLIFT PRESSURE
FASTENING
PATTERN
FASTENER
SPACING
(IN)
ADHESIVE
BEAD SIZE
s
PRESSURE
(PSF)
1
24
NONE
20.75
1
6
NONE
63.50
2
6
3/8"
86.55
• SIDEIAP ADHESME IN THE PANEL SIDBLAP
GENERAL NOTES:
1. ARCHDECTURAL ROOF PANEL HAS BEEN DESIGNED N ACCORDANCE WITH THE
FLORIDA BUILDING CODE (FBC).
2. ROOF PANELS SHALL BE .MIN. 26 CA (t - 0.018'. MAX. EFFECTIVE COVERING
WIDTH OF .PANEL = 1B'.
3, THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
SPECIFIED ON THIS DRAWING.
4. REgUIRED DESIGN IVNO LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
PANE. SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
5. ALL FASTENERS MUST BE IN ACCORDANCE WRH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE. THE CODE SHALL CONTROL
6. RAFTERS/d01STS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
OF
N