HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFING10/31/2017 Florida Building Code Online
FLORIDA 00PARTMONT OF
Business ► Professional Regulation
I
r
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Slats & Facts I Publications I FBC Staff I BCIS Site Map Links I Search I
Product Approval
a
dbor
USER. Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
OFFICE OF THE
FL #
FL11651-R2SECfilftAR�
Application Type
Code Version
Application StFsILECOA
evi 'on
2 4
rovedIY
R:
NOV V 2 O ? 0 9 7
V O G
........................
Comments
Archived
Ci
Product Manufacturer
Gulf Coast Supply & Manufacturing, LLC.
Address/Phone/Email
4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352)498-0778
flvalidation@yahoo.com
Authorized Signature
Ray Bowen
flvalidation@yahoo.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
C�i Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Daniel S. Kuhn
the Evaluation Report
Florida License PE-75519
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/12/2024
Validated By Locke Bowden
U Validation Checklist - Hardcopy Received
Certificate of Independence FL11651 R2 COI Cert of Ind Kuhn Eng.odf
FL11651 R2 COI Letter of Name change odf
Referenced Standard and Year (of Standard) Standard
Year
FM 4471
1992
TAS 100
1995
TAS 110
2000
TAS 125
2003
UL 1897
2004
UL 580
2006
Equivalence of Product Standards
Certified By
https:/Ifloddabuilding.orgtpr/pr app 00.aspx?param=wGEVXQwtDgsQFc5K%2f rrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d%3d 1/5
10/31/2017 Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
07/01/2015
Date Validated
07/10/2015
Date Pending FBC Approval
07/18/2015
Date Approved
08/18/2015
Date Revised
10/10/2017
Summary of Products
Go to Page u 0
(0 40 Pagel/20 ail
FL #
Model, Number or Name
Description
11651.1
0.032" Aluminum 5V Crimp
0.032" 5 V Crimp Aluminum Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 1 R2 0325vCrimo 15-
Approved for use outside HVHZ: Yes
32Plvwood NonHVHZ.odf
Impact Resistant: N/A
FL11651 R2 II 14FL11651 1 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-108.5PSF
Other: -108.5 psf @ 12" o.c. Install per manufacturers
Created by Independent Third Party: Yes
details. Not for use in HVHZ Zones.
Evaluation Reports
FL11651 R2 AE 14FL11651 1 R2 0325vCrimo 15-
32Plywood NonHVHZ.pdf
Created by Independent Third Party: Yes
11651.2
0.032" Aluminum Gulf Lok
0.032" Aluminum Gulf Lok 16" Wide Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 2 R2 032GulfLok 16 15-
32Plvwood NonHVHZ.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 2 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-116.OPSF
Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0
Created by Independent Third Party: Yes
psf @ 5 3/16" o.c. fastener spacing. Install per
Evaluation Reports
manufacturers details. Not for use in HVHZ Zones.
FL11651 R2 AE 14FL116SI 2 R2 032GulfLok 16 15-
32Plywood NonHVHZ.pdf
Created by Independent Third Party: Yes
11651.3
1" 24ga. Gulf Snap
1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 2 R2 Metal Roof Panel Detail.adf
FL11651 R2 II 14FL11651 3 R2 1 24GulfSnao 17 15-
Approved for use outside HVHZ: Yes
32Plywood HVHZ..odf
Impact Resistant: N/A
Design Pressure: +N/A/--131.OPS
Verified By: Dan Kuhn, P.E. 75519
Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6" ox.
Created by Independent Third Party: Yes
clip spacing. Install per manufacturers details. For use in
Evaluation Reports
HVHZ Zones.
FL11651 R2 AE 14FL11651 3 R2 1 24GulfSnap 17 15-
32Plvwood HVHZ..pdf
Created by Independent Third Party: Yes
11651.4
1" 24ga. VersaLoc
1" Versal-oc 24ga 16.5" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 4 R2 24VersaLoc SR 16.5 15-
32Plvwood HVHZ..odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FE11651 4 R2 Metal Roof Panel Detail-Rdf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-138.5PSF
Other: -71 psf @ 24" o.c. clip spacing. -138.5 psf @ 6" o.c.
Created by Independent Third Party: Yes
clip spacing. Install per manufacturers details. For use in
Evaluation Reports
HVHZ Zones.
FL11651 R2 AE 14FL11651 4 R2 24VersaLoc SR 16.5 15-
32Plvwood HVHZ..Ddf
Created by Independent Third Party: Yes
11651.5
1" Versal-oc .032" Aluminum
1" Versal-oc .032" Aluminum over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 5 R2 lin 032VersaLoc SR 16 15-
32Plvwood HVHZ..odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 5 R2 Metal Roof Panel Detail..odf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-101.OPSF
Other: -63.3 psf @ 24" o.c. clip spacing. -101.0 psf @ 6"
Created by Independent Third Party: Yes
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f rrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d%3d 2/5
10/31/2017
Florida Building Code Online
o.c. clip spacing. Install per K acturers details. For use
in HVHZ Zones.
11651.6 1 1.5" 24ga. Gulf Snap
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116.OPSF
Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o.c. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install
per manufacturers detals. For use in HVHZ Zones.
Evaluation Reports
FL11651 R2 AE 14FLif,651 5 R2 lin 032VersaLoc SR 16 15-
32Plvwood HVHZ..Ddf
Created by Independent Third Party: Yes
1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 R2 II 14FL11651 6 R2 1.5 24GulfSnao 16 15-
32Plvwood HVHZ..Ddf
FL11651 R2 II 14FL11651 6 R2 Metal Roof Panel Detail..Ddf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 6 R2 1.5 24GulfSnao 16 15-
32Plvwood HVHZ..odf
Created by Independent Third Party: Yes
111651.7 1 1.5" 24ga. Versal-oc 1 1.5" Versal-oc 24ga. 16" wide Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-123.5PSF
Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @
12" o.c. clip spacing. Install per manufacturers details. For
use in HVHZ Zones.
11651.8 12" 24ga. MegaLoc
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. Not for
use in HVHZ Zones.
Installation Instructions
FL11651 R2 II 14FL11651 7 R2 1.5 24VersaLoc 16 15-
32Plywood HVHZ..Ddf
FL11651 R2 II 14FL11651 7 R2 Metal Roof Panel Detail..adf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 7 R2 1.5 24VersaLoc 16 15-
32Plvwood HVHZ..pdf
Created by Independent Third Party: Yes
24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 R2 II 14FL11651 8 R2 24MegaLoc 18 15-
32Plvwood NonHVHZ.Ddf
FL11651 R2 II 14FL11651 8 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 8 R2 24MegaLoc 18 15-
32Plvwood NonHVHZ.odf .
Created by Independent Third Party: Yes
11651.9
24 Ga. Gulf Lok
24 Ga. Gulf Lok 16" Wide over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 9 R2 24GulfLok 16 IS -
32Plvwood NonHVHZ.odf
FL11651 R2 II 14FL11651 9 R2 Metal Roof Panel Detail.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-96.7PSF
Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76
Created by Independent Third Party: Yes
psf @ 5-1/8" o.c. fastener spacing.-121.75 psf @ 5-1/8"
Evaluation Reports
fastener spacing. -161 psf @ 5-1/8" fastener spacing. Install
FL11651 R2 AE 14FL11651 9 R2 24GulfLok 16 15-
32Plvwood NonHVHZ.Ddf
per manufacturers details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.10 124 Ga. Gulf Seam
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-93.5PSF
Other: -93.5 psf @ 18" o.c. Install per manufacturers
details. Not for use in HVHZ Zones.
24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood Purlins
over 15/32" Plywood
Installation Instructions
FL11651 R2 II 14FL11651 10 R2 24GulfSeam 16 1x4 15-
32Plvwood NonHVHZ.odf
FL11651 R2 II 14FL11651 10 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 10 R2 24GulfSeam 16 1x4 IS-
32Plvwood NonHVHZ.odf
Created by Independent Third Party: Yes
11651.11 124 Ga. Gulf Seam 124 Ga. Gulf Plywood Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel over
32"
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @
12" o.c. clip spacing. Install per manufacturers details. Not
for use in HVHZ Zones.
Installation Instructions
FL11651 R2 II 14FL11651 it R2 24GulfSeam 18 IS-
32Plywood NonHVHZ.odf
FL11651 R2 II 14FL11651 11 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 11 R2 24GulfSeam 18 IS-
32Plywood NonHVHZ.odf
Created by Independent Third Party: Yes
https://floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgsQFr5K%2ffrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d%3d 3/5
10/31/2017
Florida Building Code Online
11651.12 126 Ga. 5V Crimp
26 Ga. 5V Crimp Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-156.5PSF
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf
@ 6" o.c. fastener spacing. Install per manufacturers
details. For use in HVHZ Zones.
Installation Instructions
FL11651 R2 II 14FL11651 12 R2 265vCrimo 15-
32Plvwood HVHZ.odf
FL11651 R2 II 14FL11651 12 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 12 R2 265vCrimo 15-
32Piywood HVHZ.pd
Created by Independent Third Party: Yes
11651.13
26 Ga. 5V Crimp
26 Ga. 5V Crimp over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 13 R2 265vCrimo 11-
Approved for use outside HVHZ: Yes
32Plvwood NonHVHZ.Ddf
Impact Resistant: N/A
FL11651 R2 II 14FL11651 13 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-131.PSF
Other: -94.25 psf @ 16" o.c. fastener pattern. -131.0 psf
Created by Independent Third Party: Yes
@ 16" o.c. fastener pattern. Install per manufacturers
Evaluation Reports
details. Not for use in HVHZ Zones.
FL11651 R2 AE 14FL11651 13 R2 265vCrimo 15-
32Plvwood NonHVHZ.odf
Created by Independent Third Party: Yes
11651.14 126 Ga. 5V Crimp
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-156.5PSF
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf
@ 6" o.c. fastener spacing. Install per manufacturers
details. For use in HVHZ Zones.
26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32"
Plywood
Installation Instructions
FL11651 R2 II 14FL11651 14 R2 265vCrimo Ix4 15-
32Plvwood NonHVHZ.pdf
FL11651 R2 II 14FL11651 14 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 14 R2 265vCrimo 1x4 15-
32Plywood NonHVHZ.pdf
Created by Independent Third Party: Yes
111651.15 126 Ga. Gulf Lok 126 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-161.OPSF
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
psf @ 5 3/16" spacing. -161.0 psf @ 5 3/16" o.c. fastener
spacing. Install per manufacturers details. For use in HVHZ
Zones.
11651.16 126 Ga. Gulf Lok
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-63.5PSF
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
psf @ 5 3/16" fastener spacing. -161 psf @ 5 3/16" fastener
spacing. Install per manufacturers details. Not for use in
HVHZ Zones.
11651.17 126 Ga. GulfPBR
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-154.7PSF
Other: -59.25 psf @ 24" o.c. fastener pattern. -154.75 psf
@ 12" o.c. fastener pattern. Install per manufacturer
details. Not for use in HVHZ
11651.18 126 Ga. GulfPBR
Installation Instructions
FL11651 R2 II 14FL11651 15 R2 26GulfLok 16 15-
32Plvwood HVHZ.odf
FL11651 R2 II 14FL11651 15 R2 Metal Roof Panel Detail.oddf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 15 R2 26GulfLok 16 15-
32Plywood HVHZ.pdf
Created by Independent Third Party: Yes
26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 R2 II 14FL11651 16 R2 26GulfLok 16 15-
32Plvwood NonHVHZ.pdf
FL11651 R2 II 14FL11651 16 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 16 R2 26GulfLok 16 15-
32Plvwood NonHVHZ.odf
Created by Independent Third Party: Yes
26 Ga. Gulf PBR Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 R2 II 17 R2 26GulfPBR 15-32Plvwood NonHVHZ.Pdf
FL11651 R2 II 17 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 17 R2 26GulfPBR 15-
32Plvwood NonHVHZ.odf
Created by Independent Third Party: Yes
26 Ga. GulfPBR Roof Panel over 1x4 Wood Purlins over 15/32"
Plywood
Limits of Use
Installation Instructions
hftps://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f rrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d%3d 4/5
10/31/2017
Florida Building Code Online
Approved for use in HVHZ
FL11651 R2 II 14FL. l 18 R2 26GulfPBR 1x4 15-
Approved for use outside - _ !: Yes
32Plvwood HVHZ.pdf
Impact Resistant: N/A
FL11651 R2 II 18 R2 Metal Roof Panel Detail.Ddf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-151.7PSF
Other: -100.5 psf @ 24" D.C. fastener spacing.-151.75 psf
Created by Independent Third Party: Yes
@ 12" fastener spacing. Install per manufacturer's details.
Evaluation Reports
For use in HVHZ Zones
FL11651 R2 AE 14FL11651 18 R2 26GulfPBR 1x4 15-
32Plvwood HVHZ.pdf
Created by Independent Third Party: Yes
11651.19
26 Ga. GulfPBR
26 Ga. GulfPBR over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 19 R2 26GulfPBR 15-
Approved for use outside HVHZ: Yes
32Plvwood HVHZ.pdf
Impact Resistant: N/A
FL11651 R2 II 19 R2 Metal Roof Panel Detail.Ddf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-154.7PSF
Other: -60.5 psf @ 24" D.C. fastener spacing.-154.75 psf
Created by Independent Third Party: Yes
@ 12" D.C. fastener spacing. Install per manufacturer's
Evaluation Reports
details. For use in HVHZ Zones.
FL11651 R2 AE 14FL11651 19 R2 26GulfPBR 15-
32Plvwood HVHZ.Ddf
Created by Independent Third Party: Yes
11651.20
26 Ga. GulfPBR
26 Ga. GulfPBR over 1x4 Wood Purlins over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 20 R2 26GulfPBR 1x4 15-
Approved for use outside HVHZ: Yes
32Plvwood NOnHVHZ.pdf
Impact Resistant: N/A
FL11651 R2 II 20 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-151.7PSF
Other: -94.25 psf @ 24" D.C. fastener spacing.-151.75 psf
Created by Independent Third Party: Yes
@ 12" fastener spacing. Install per manufacturer's details.
Evaluation Reports
Not for use in HVHZ Zones
FL11651 R2 AE 20 R2 26GulfPBR 1x4 15-
32Plvwood NonHVHZ.Ddf
Created by Independent Third Party: Yes
Go to Page = 0
Back Next
0 4) Page 1/ 2 0 0
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
45S.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please dick here .
Product Approval Accepts:
MEM M ® eClik
Credit Card
Safe
hitps://floridabuilding.org/pr/pr app_dg.aspx?param=wGEVXQwtDgsQFc5Kp/`2frrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA°/`3d%3d 5/5
'doll! --de
Product Evaluation Report
GULF COAST SUPPLY & MANUFACTURING, LLC.
26 Ga. 5V Crimp Roof Panel over 15132" Plywood
Florida Product Approval #11651.13 R2
Florida Building Code 2014
Per Rule 61 G20-3
Method: 1 —D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 61G20-3.005(1)(d)
NON HVHZ
Product Manufacturer:
Gulf Coast Supply & Manufacturing, LLC.
14429 SW 2nd Place, Suite G30 %Ol% EL 5101''�
Newberry, FL 32669 , ,
Engineer Evaluator:
Dan Kuhn, P.E. #75519
Florida Evaluation ANE ID: 10743
Validator:
Locke Bowden, P.E. #49704
9450 Alysbury Place
Montgomery, AL 36117
Contents:
Evaluation Report Pages 1 — 5
FL# 11651.13 R2 •1UNE 15, 2015
o,,. • y
No, 7551.9
' STATE of
0R1OP .•����•
''�, �01VA L EN
w�r �en4)
Compliance Statement:
The product as described in this report has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2.
Product Description:
5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, through fastened
roof panel with fasteners in the panel flat over minimum 15A2" plywood decking.
Non Structural application.
Panel Material/Standards:
Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2014 Section 1507.4.3.
Paint Finish Optional
Yield Strength: 80.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2014, Section 1507.4.3.
Panel Dimension(s):
Thickness: 0.018" Minimum
Width: 24" Coverage
Rib Height: 3/s" Major Rib
Panel Fastener:
#9-15x1.5" with sealing washing in the flat of the panel or approved equal,
1A" minimum penetration through plywood.
Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4
Substrate Description:
Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C.
Design of plywood and plywood supports are outside the scope of this evaluation.
Must be designed in accordance w/ Florida Building Code 2014.
Design Uplift Pressures:
FL# 11651.13 R2 • JUNE 15, 2015
Table "A"
Maximum Total Uplift Design Pressure
94.25 psf
131.0 psf
Fastener Pattern
12"-12"
9.5"-2"-9.5"
Fastener Pattern Spacing
.1.6" .O..C.
16" O.C.
Design Pressure includes a Safety Factor = 2.0.
I 1r7!!W2\W . 0
Code Compliance: The product described herein has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2014, as relates to Rule 61 G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
• UL 580-06 - Test for Uplift Resistance of Roof Assemblies
• UL 1897-04 - Uplift Test for Roof Covering Systems.
Reference Data: 1. UL 580-94 / 1897-98 Uplift Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 117-0053T-05 & 117-0331T-08
2. Certificate of Independence
By Dan Kuhn, P.E. (FL# 75519) @ Kuhn Engineering, LLC
(FBC Organization # ANE ID: 10743)
Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test
standard.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61 G20-3.005(3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including
Section 1507.4.2 and in accordance with Manufacturers recommendations. For
slopes less than 3:12, lap sealant must be used in the panel side laps.
Installation: Install per Manufacturer's recommended details.
Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2.
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear Diaphragm values are outside the scope of this report.
FL# 11651.13 R2 • JUNE 15, 2015
Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must
at a minimum meet those listed for the applicable wind zone. For all roofs outside
the parameters listed on the load table, design wind loads shall be determined
for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10
using allowable stress design. The maximum fastener spacing listed herein shall
not be exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this
product in High Velocity Hurricane Zone.
FL# 11651.13 R2 • JUNE 15, 2015
ENGINEER LOAD TABLE: 26 Ga. 5VCrimp Roof Panel over 15/32" Plywood
Buildings having a Roof Mean Heights 20'-.0".; Roof'Slope: 2-" /12" - 12"/12" `Gable or Hip Roof; Wind Speeds 120-
180mph, Exposure C, Risk Category 11, Enclosed Building, based on Florida Building Code. 2014.
120
130
140
150
160
170
180
WIIND
FASTENER
SUBSTRATE
SPEED
(MIN. 1/4"
Penetration)
(MIN.15/32")
ON CENTER
ON CENTER
ON CENTER
ON CENTER
ON CENTER
ON CENTER
ON CENTER
SPACING
SPACING
SPACING
SPACING
SPACING
SPACING
SPACING
ZONE 1
#9-15x1.5"
Plywood
16" TYPE 1
16" TYPE 1-
16" TYPE 1
16" TYPE 1
16" TYPE 1
16" TYPE 1,
16" TYPES
ZONE 2
#9-15x1.5"
Plywood
16" TYPE 1
16" TYPE 1
16" TYPE 1
16" TYPE 1
16" TYPE 1
16" TYPE 1
16" TYPE 1
ZONE 3
#9-15x1.5"
Plywood
16" TYPE 1
16" TYPE 1
16" TYPE 1
16" TYPE 1
16" TYPE 1
16" TYPE 2
16" TYPE 2
1.) PANEL DESCRIPTION: 5V CRIMP, MIN. 26 GA., GRADE 80, 24"COVERAGE.
2j PANEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER W/ MIN.'/4" PENETRATION.
3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: -94.25 PSF@ 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN, -131.0
PSF @16" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING.
4.) PLYWOOD DECKING: MIN. '%2" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014.
5.) ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS.
6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING
CODE 2014
nip nnn;
LVIYC L ZONE 3—,,
T-
!------ ------------
RIDGE
ZONE1
Note: Dimension (a) is defined as 10% of the minimum width of the building or
—�a 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be
less than either 4% of the minimum width of the building or 3 feet.
ZONE 2 GABLE ROOF
--- ------------------
I I
I I
RIDGE j
+-----
-------------------+ — a
I
ZONE 1
I I
-I-----------------------I-
OZONE 3 —EAVE
FL# 11651.13 R2 • JUNE 15, 2015
TYPE 1 FASTENER PATTERN
(1) #9-15 x 1-1/2" HWH w/Sealing Washer
�-12" 12"
At Panel Lap -::�
TYPE 2 FASTENER PATTERN
(1) #9-15 x 1-1 /2" HWH w/Sealing Washer