HomeMy WebLinkAboutEVALUATION REPORT ASPHALT ROOF SHINGLESQOTRINITYIERD
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
N0V282op
t E-wi1TI;dG
5t. Lucie OountY, FL
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report 037940.02.12-R7
FL10674-1112
Date of Issuance: 02/06/2012
Revision 7: 04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 04/18/2016. This does not serve as an electronically signed
document. Signed, sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest,in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingle
Compliance Statement: Owens Corning Asp
compliance with the following sections of tF
through testing in accordance with the folloi
and Limitations / Conditions of Use set forth
2. STANDARDS:
i
r^ 1
QOTRINITYIERD
salt Roof Shingles, as produced by Owens Corning, have demonstrated
e Florida Building Code and Florida Building Code, Residential Volume
sing Standards. Compliance is subject to the Installation Requirements
ierein.
Section
Property
I
Standard
Year
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2009
1507.2.7.1, R905.2.6.1
Wind Resistances
ASTM D3161
2009
1507.2.7.1, R905.2.6.1
Wind Resistance,
ASTM D7158
2008
3. REFERENCES:
Entity
Examination I
Reference
Date
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-112453
05/16/2012
UL LLC (TST9628)
Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
11CA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wined Resistance
4786093137
02/01/2014
UL LLC (TST9628)
Wind Resistance
4786126532
02/10/2014
UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TST9628)
Physical Properties
Classification letter
10/02/2015
Miami -Dade (CER1592)
FBC HVHZ Compliance
Various NOAs
Various
UL LLC (QUA9625)
Quality Controll
Service Confirmation, R2453
Exp. 08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme' are fiberglass reinforced, 3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,) 4-tab asphalt roof shingles.
4.1.3 Devonshire'"" are fiberglass reinforced, 5-tab asphalt roof shingles.
4.1.4 Duration®, TruDefinitioe Duratiol., Duration Premium Cool, TruDefinition' Duration® Designer Color
Collection, TruDefinition' 0akridge , Oakridge' and WeatherGuard® HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Berkshire® Hip & Ridge Shingles, High Ridge, WeatherGuard HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidgeTm Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Starter Strip Shingle, Starter Strip Pilus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any projection which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for u
5.3 Fire Classification is not part of thi
for fire ratings of this product.
in the HVHZ.
Evaluation Report; refer to current Approved Roofing Materials Directory
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-117
Certificate of Authorization #9503 FL10674-1112
Revision 7: 04/18/2016
Page 2 of 8
QOTRINITYIERD
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to Vasd = 150 mph (V,,it = 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip. Shingle and Starter Strip Plus noted herein are Classified
in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are
acceptable for use in all wind zones up to Vasd = 150 mph (Vult = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations. Contact
the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
➢ Berkshire shingles require minimum five (5) nails per shingle.
➢ WeatherGuardm HP shingles require minimum six (6) nails per shingle.
Devonshire'" shingles require minimum six (6) nails per shingle.
Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing — Starter Strip Shingle and Starter Strip Plus:
Fekundedayment Deck Sdkdhered
Weeterlock9
undedaymant
' Drip edge
Drip—
edge .
' Nags located
2"-3' hom eave
InetslfitstStarterStripPlus Selina edalon eae
with V removed positioned along cave
Starter pPlus overhangseaves and ralm1/4"-3/4"
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R7
Certificate of Authorization #9503 F1.10674-1112
Revision 7: 04/18/2016
Page 3 of 8
6.2.6 Minimum Nailing - Classic® & Suprem;e:
Normal Mansard.or
Wind Areas High-Wiftnd
Area pan vihrtos norrnaies Areas'
t IAI t 107.1
t�•
to EYpasun
t:rposicl6n
6.2.7 Minimum Nailing - Berkshire®:
M
Standard Fastening Pattern
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
TTRINITYERD
Normal Mansard or Ar"'par&
1NindAeaas High,INlnd duvanesy
Area Ostei wentos norinates Araas' viontos faros
6 6/8',Exposun:
Expoaieldn
Sealant strip
La tba doseNador
�t• 8Yt• 8Ih• 8w, 8w
r
Sealaritstiip
La tha de selkdor
-►.a :ate-►
to S ,
Mai sard or Steep Slope Fastening Pattern
6-Nail Fastening Pattern
1°
Evaluation Report 037940.02.12-117
F1.10674-1112
Revision 7: 04/18/2016
Page 4 of 8
6.2.8 Minimum Nailing — Devonshire TM:
1" 7" 8" 8" 8" 7" 1"
N.
darta
5.5/8' exposure Sealant location
Exposid6n de 5 -6/8 ping Ubiced6n del sellador
r -
QOTRINITYIER'D
Nails
,• r e r
IS u•
sw en•
Ten t" Spots of Asphalt Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration°, TruDefinition® Duration, Duration° Premium Cool & TruDefinition Duration
Designer Color Collection:
"an Fastening Patter
. sunNaszDrutemnynavAeni
►W%Ty",
1" tr 't2a • f
stia=
aam.
i
Standard Fastenina Pattern
Exterior Research and Design, LLC.
Certificate ofAuthoriration #9503
63iatl Fastening Pattern.
S,eatLiil®tmLeN,p aka W15h
r tr• tr
evr
san^
Mansard or Steep Slope Fastening Pattern
6-Nail Fastening Pattern
Evaluation Report 037940.02.12-117
FL10674-1112
Revision 7: 04/18/2016
Page 5 of 8
6.2.1 Minimum Nailing —TruDefinitione0akridge", Oakridge®:
I
Standard Fastening Pattern
12-
SuregaN fashming am w1ifth
I Pau P Spab OWP—W Rook* C*W&M
Maksard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing — WeatherGuardjlHP- -
QI KINITYIERD
6-Nail Fastening Pattern
I
Onalie"We'Aw.
t1m Mir nqM&hPkffl lima
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R7
Certificate of Authorization #9503 F1.10674-1112
Revision 7:04/18/2016
1 Page 6 of 8
w
QOTRINITYIERD
6.3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuardo HP Hip and Ridge Shingles and
ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four
(4) nails per shingle. Installation of DuraRidgeTm Hip & Ridge Shingles shall comply with the manufacturer's
current published instructions, using two (2) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand -sealing for wind
warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge:
#Jgo.. Q:
� :Aewil�rmnd
.;Direction
�Nads` ,. A •
ExPoWe
I I
,p, �• I 'I I I
e-
6.3.4 Minimum Nailing—WeatherGuard® HP Hip and Ridge:
Fig. C,Hip &Ridge :Shingle Fastening
TOPYL-W
Nalb Naps
r.•-
r, 2^
V. E1lposare
'y1
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7
Certificate of Authorization #9503 FL30674-1112
Revision 7: 04/18/2016
Page 7 of 8
6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles:
PrevaRing
Wind Direction selhM Strip
A--' 8° Exposure
With
QOTRINITYIERD
Standard �17°•
Pstenin
atter g --��
ICY
12° 1 Se�llllt
6° Eapos t
I
6.3.6 Minimum Nailing — DuraRidgeTm Hip & Ridge Shingles:
Note: The drawings below pertain to (minimum, as -tested attachment requirements. Refer to Owens Corning
published installation instructions for, their minimum requirements.
i7=ico do m djvmt
Wranddndd 41mm pndordd
MIR
&_kl�
7. LABELING:
7.1 Labeling shall be in accordance m
herein.
7.2 Asphalt shingle wrappers shall indi
Table 1507.2.7.1 / R905.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Au&
this'product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for informat
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC— QUA9,625 ; (414) 248-6409; karen.b
Top Vlew
� ge�r[or u
Ct
Ctau
j° • OmnsConing 9umW a O
� I
I
�le>±
U I
I
iz
the requirements the Accredited Quality Assurance Agency noted
compliance with one of the required classifications detailed in FBC
Having Jurisdiction in order to properly evaluate the installation of
n on which plants produce products covered by Florida Rule 9N-3 QA
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R7
Certificate of Authorization #9503 F1.10674-1112
Revision 7: 04/18/2016
Page 8 of 8