SPECIFICATION NOTES
ETERS: L POLY ROOF CARPORT
HIS CARPORT STRUCTURE MEETS THE FLORIDA BUILDING CODE FOR A HEIGHT 8'-0-,150 MPH, EXP. 'C'
WIND SPEED. THE TABLES BELOW ARE BASED ON SIMULTANEOUS LOADING AS DEFINED IN THE FLORIDA
BUILDING CODE (FBC), CHAPTERS 16 AND 20, AND OTHER REFERENCES SUCH AS ALUMINUM ASSOCIATION
OF FLORIDA (AAF) "GUIDELINES TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS". STRUCTURAL
VALUES FOR EXTRUDED ALLOY 6005T5 ARE TAKEN FROM THE ALUMINUM DESIGN MANUAL, 2015 EDITION.
TABLE 1 MAIN ROOF MEMBER SCHEDULE
MEMBER
IMARKIMANF.1
WEIGHT
ATERIA
THICKNESS
I LENGTH DESIGN BASIS
#
I SKIN
I POLY r SKIN
FT.
FL. PROD. APPR.
POLY ROOF PANEL # 1
I PRP1
I ELITE
I 1
I ALUM
1 3"
1 0.024
1 11'-0"
FL7561-R3, DWG.
OR =
FL-1001, 3-20-15
TABLE 2 MAIN MEMBER SCHEDULE
MEMBER --- Tm-A-g-KT
SIZE
I MATERIAL
I TYPE
I THICKNESS
LENGTH DESIGN BASIS
b x t
ALLOY
W
F
FT.
COLUMN # 1
COLUMN # 2
CARRIER BEAM # 1
ROOF BEAM # 1
KNEE BRACE # 1
Cl
3x3-12
ALUM
TUBE
0.125
0.125
8'-0"
1 CALCULATION
C2
3x3-12
ALUM
TUBE
0.125
0.125
8'-6"
CALCULATION
CBI
2x5
ALUM
SMB
0.050
0.116
8'-0"
CALCULATION
RBI.
2x4H
ALUM
HOLLOW
0.050
0:050
10'-0"
CALCULATION
KB1
2x3-7
ALUM
HOLLOW
0.070
0.070
2'-10" .
CALCULATION
ADDITIONAL SITE SPECIFIC INFORMATION NOTE: • AVERAGE
THIS POLY ROOF CARPORT IS LOCATED IN A RESIDENTIAL COMMUNITY NORTH OF SE WALTON ROAD AND EAST OF
U.S. ROUTE I IN PORT ST. LUCIE. THE CARPORT HAS MANY OPEN AREAS AROUND IT. THE ENCLOSURE IS ABOUT
1500 FEET WEST OF THE SAVANNAS PRESERVE STATE PARK. PER THE EXPOSURE CATEGORIES LISTED IN SECTION
1609.4.3 OF THE FLORIDA BUILDING CODE THIS ENCLOSURE SHALL CONSERVATIVELY BE CALLED AN EXPOSURE 'C'.
ACCORDING TO THE COMPUTER PROGRAM "WINDSPEED BY LOCATION", A PRODUCT OF 'APPLIED TECHNOLOGY
COUNCIL' THE DESIGN WIND LOAD REQUIREMENTS FOR A RISK CATEGORY 1 ENCLOSURE IN THIS LOCATION IS
DICTATED BY A WIND SPEED OF 148 MPH. HENCE, THE DESIGN PARAMETERS BEING USED HERE ARE 150 MPH WIND
LOAD, EXPOSURE 'C', RISK CATEGORY I.
THE NEW POLY ROOF CARPORT IS BEING INSTALLED BECAUSE THE EXISTING CARPORT, WHICH WAS BUILT IN THE
1990S, WAS DAMAGED DURING A RECENT HURRICANE IRMA THIS SEPTEMBER. THE FRONT IS 8'-0- HIGH AND THE
REAR IS 8'-6" HIGH; WITH A RUN OF 10.0 FEET GIVES A SLOPE OF ABOUT 0.60 INCHES PER FOOT. THE POLY ROOF
CARPORT IS BEING BUILT ON AN EXISTING NOMINAL 4" SLAB THAT IS IN GOOD CONDITION. THIS FOUNDATION IS
ACCEPTABLE FOR THIS SCREEN ENCLOSURE. THE DESIGN DRAWING IS SHOWN ON SHEET 2. THE POLY ROOF
CONNECTION DRAWINGS ARE SHOWN ON SHEETS 3.
THE HOST STRUCTURE IS A MODULAR HOME SO 4TH WALL CONSTRUCTION FOR COMPOSITE ROOFS WILL BE USED.
THEREFORE, THE COLUMNS, BRACING AND CONNECTIONS SHOWN ON SHEET 2 ARE THE SAME IN THE BACK AS IN THE
FRONT EXCEPT THAT THE BACK IS 6 INCHES HIGHER. THERE SHALL BE NO STRUCTURAL ATTACHMENT BETWEEN
THE POLY ROOF CARPORT AND THE MOBILE HOME BUT IT IS ACCEPTABLE TO INSTALL FLASHING TO KEEP THE
RAIN OUT. THE CARRIER BEAM TO COLUMN CONNECTION CAN BE MADE WITH 7" LONG CHANNELS AND FOURTEEN
(14) #12 SMS, SEVEN (7) BETWEEN EACH CHANNEL AND COLUMN AND SEVEN (7) BETWEEN EACH CHANNEL AND EDGE
OR MID BEAM, SIMILAR TO KNEE BRACE CONNECTIONS ON SHEET 2. ALSO, SEE OPTIONAL CONNECTION DRAWINGS
BETWEEN COLUMNS AND CARRIER BEAMS BELOW.
OPTIONAL CARRIER BEAM TO COLUMN CONNECTION
BOLTED CONNECTION-' OPTION # 1 I BOLTED CONNECTION - OPTION # 2
THE ROOF BEAM CAN BE CONNECTED
TO THE COLUMN WITH TWO 1/2" SS
NUTS., BOLTS AND SS WASHERS.
2" WIDE CARRIER BEAM
(CB) OR EDGE BEAM (EB)
THE ROOF BEAM CAN BE CONNECTED TO THE COLUMN
WITH TWO 1/2" SS NUTS, BOLTS AND SS WASHERS.
2" WIDE CARRIER BEAM
(CBI OR EDGE BEAM (EB)
PLAN VIEW - CORNER COLUMN ` PLAN VIEW - MIDDLE COLUMN
THIS DESIGN COMPLIES WITH THE GUIDELINES DEFINED IN CHAPTERS 16 & 20 OF THE FLORIDA BUILDING CODE (FBC), 5TH
EDITION (2014) BUILDING, USING THE ALLOWABLE STRESS DESIGN PRESSURES LISTED IN TABLE 2002.4 AND TABLE 2002.4A.
THE AAF STANDARDS OF THE "GUIDELINES TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS" FOR TABLE 1 ARE APPLIED.
A DESIGN BASICS: THIS POLY ROOF CARPORT IS A RISK CATEGORY I STRUCTURE. HEIGHT 8'-0", 150 MPH, EXP. 'C'
B THE BUILDING CLASSIFICATION RISK CATEGORIES ARE FROM FBC, TABLE 1604.5 AND AREA LOCATION WIND SPEED PER
FBC, FIGURE 1609C.. BUILDING CLASSIFICATION PER TABLE 27.2-1, ASCE 7-10.
C DESIGN PRESSURE: FOR SOLID ROOF @ 30.96 PSF PER TABLE 2002.4.
D MAXIMUM HEIGHT: HEIGHTS HIGHER THAN LISTED ABOVE REQUIRE SITE -SPECIFIC DESIGN BY THE ENGINEER OF RECORD.
E ALLOWABLE DEFLECTION: L 160 MINIMUM, AS SPECIFIED IN TABLE #1604.3 OF FBC.
F CONTINUOUS LOAD PATH IS PROVIDED WITHIN THE CALCULATIONS USING ALLOWABLE STRESS DESIGN PRESSURES.
2 MATERIALS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD):
A ALL EXTRUSION MATERIALS SHALL BE ALUMINUM ALLOY # 6005T5 OR # 6061176; ALLOY # 6063176 IS NOT ACCEPTABLE.
B FASTENERS: ALUMINUM ALLOYS #2024-T4 & #7075-176, DOUBLE CAD -PLATED STEEL, HOT -DIPPED GALVANIZED STEEL OR
300-SERIES STAINLESS STEEL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE FOR SEPARATION OF
DISSIMILAR MATERIALS AS DEFINED IN THE FBC. HE/SHE MAY IMPLEMENT ANY OF THE MEANS LISTED IN THESE SECTIONS.
ALTERNATIVES MUST BE REVIEWED AND APPROVED IN WRITING BY THE ENGINEER 0ffi.t5I f M8 OnTTACHNIEN T S
INSTALLATIONS UTILIZING THE SUBJECT METHODS. lr ' ��11�+ T� r,CCP E
C SCREEN CLOTH: SHALL BE VINYL -COATED, WOVEN -FIBERGLASS, MAXIMUM DENSITY OIA9X 14, 98 /o`i`�i>7="N`NIIIVIINUM: -
OTHER SCREEN DENSITY REQUIRE ADDITIONAL ENGINEERING CONSIDERATION. CONTRACTOR OF RECORD
D ANY CONNECTION USED, THAT IS NOT SHOWN ON THESE SHEETS, MUST MEET ALL FBC AND AAF GUIDELINES.
E MATERIAL UPGRADES (STRONGER AND/OR HIGHER GRADE MATERIALS) CAN BE SUBSTITUTED AT ANY TIME.
F A 2x2 OR A 2x3 SNAP MEMBER CAN ALWAYS REPLACE A 2x2 OR A 2x3 HOLLOW MEMBER, RESPECTIVELY.
G WHEREVER SCREENING OR KICKPLATES ABUTS THE HOUSE OR CONCRETE THE MEMBER USED TO SUPPORT THAT
SCREENING OR KICKPLATE WILL BE A 1" x 2" x 0.046" O.B. OR STRONGER ALUMINUM MEMME PLANS.AND ALL PROPOSED WORK
HALL DOOR JAMS (DJ) SHALL BE 2" x 2" x 0.046" ALUMINUM MEMBERS OR STRONGER. ARE SUBJECT TO ANY CORRECTIONS
IT IS ALWAYS ACCEPTABLE TO ADD OR RELOCATE A SCREEN DOOR AS LONG AS THE CO M69 e9� TO THAT
COMPLY WITH ALL APPLICABLE CODES.
3 ALL HOUSE FASCIA DETAILS, BOLTING OR SCREW SELECTIONS, BEAM SPLICE DETAILS, DIAGONAL "K" BRACING DETAILS,
COLUMN TO BEAM DETAILS, STRUCTURAL GUTTER DETAILS, WALL AND FASCIA DETAILS, CORNER ANCHOR DETAILS,
ROOF BRACING DETAILS, EAVE BRACING DETAILS, ETC., IF NOT EXPLICITLY OUTLINED ON THIS SPECIFICATION, SHALL BE
IN ACCORDANCE WITH -WE LATEST FBC EDITION, INCLUDING THE AAF. ALL INTERNAL CONNECTIONS SHALL MEET THE
FBC (AAF) AND THERE INSTALLATION ARE THE RESPONSIBILITY OF THE CONTRACTOR.
4 WHERE APPLICABLE, THE LOCATION OF ALL "K" BRACING, WIND BRACING, EAVE RAILS AND CHAIR RAILS, ALONG WITH
ANY DESIGN ABNORMALITY, ARE SHOWN AND/OR LISTED ON SHEET 2, THE "SITE SPECIFIC DRAWING".
5 ALL STRUCTURES ERECTED ON CONCRETE SLABS AND / OR FOOTERS SHALL BE CALCULATED TO ASSURE THERE IS
SUFFICIENT HOLD DOWN CAPABILITY TO MEET THE REQUIREMENTS OF A THE ENCLOSURE.
f
6 THE AVERAGE SPACING' BETWEEN BEAMS IS SHOWN ON THE "SITE SPECIFIC DRAWING". THE ACTUAL SPACING BETWEEN
ANY TWO BEAMS MUST BE THE LISTED SPACING, +/- 2". THE OVERALL AVERAGE SPACING MUST BE EQUAL TO THE
AVERAGE SPACING SHOWN ON THE "SITE SPECIFIC DRAWING". ALL SPACING MUST NEVER BE GREATER THAN 8.0' O.C.
7 IN LIEU OF "SITE SPECIFIC ENGINEERING" AN EXISTING SLAB SHALL MEET THE FOLLOWING REQUIREMENTS:
A THE SLAB MUST BE IN GOOD CONDITION, 4" OR GREATER THICKNESS, CONSTRUCTED WITH REBAR, WIRE OR FIBER MESH.
B ALL HOLD DOWN FASTENERS MUST BE NO MORE THAN 24" ON CENTER WITH MINIMUM ENGAGEMENT OF 2".
8 ALL NEW SLABS, WITH OR WITHOUT FOOTERS, SHALL MEET THE FOLLOWING REQUIREMENTS AS A MINIMUM:
A SOIL MUST BE WELL COMPACTED AND TREATED FOR TERMITES PER COUNTY REQUIREMENTS,
B 4" NOMINAL PATIO SLAB, REQUIRES A VAPOR BARRIER IF THE SLAB ABUTS LIVING QUARTERS,
C 4" NOMINAL PATIO SLAB WITH CONCRETE @ 3000 PSI (MIN.) WITH FIBER MESH OR REBAR AND WIRE,
D SHALL BE SECURED TO EXISTING CONCRETE WITH #5 REBAR EVERY 24" O.C. TO AVOID SETTLEMENT, IF APPLICABLE.
9 ALL NEW PERIMETER FOOTERS SHALL MEET THE FOLLOWING REQUIREMENTS AS A MINIMUM:
A SOIL MUST BE WELL COMPACTED AND TREATED FOR TERMITES PER COUNTY REQUIREMENTS,
B CONCRETE @ 3000 PSI (MIN.) WITH ONE #5 REBAR FOR 8" x 8" AND TWO #5 REBAR FOR LARGER FOOTERS.
10 . ALL NEW PERIMETER FOOTER POURED.WITH A SLAB SHALL MEET THE FOLLOWING CONDITIONS:
A PERIMETER FOOTER AND THE SLAB SHALL BE MONOLITHICALLY POURED,
B ALL REQUIREMENTS OF ITEMS 8 AND 9 ABOVE.
11 ALUMINUM IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PROTECTED WITH AN ALKALI RESISTANT COATING.
12 THIS DRAWING COVERS ONLY THE ITEMS LISTED IN THE TITLE BOX. ANY OTHER TASK, SUCH AS ELECTRICAL,
PLUMBING, ETC, SHALL BE BY OTHERS AND SHALL BE COVERED BY A SEPARATE DESIGN DOCUMENT.
DWG. # RVC-2017-107, REV. 0
November 22, 2017
SHEET 1 OF 3
GENERIC DESIGN DATA
R V CONSTRUCTION
3318 COLUMBRINA CIRCLE
PORT ST. LUCIE, FL 34952
OFFICE (772) 380-8253
LICENSE # CRC 1330965
• . LOCATION:
NAME:
CONSTANZO RESIDENCE
ADDRESS:
8513 LIDFLOWER COURT
CITY/STATE:
PORT ST. LUCIE, FL 34952
COUNTY:
ST. LUCIE
02
(?I (- "?
COUNTY 21JlLDriC'VMS3Q1�
D FOR COMM NC
D BY
FOR BUILDING PERMITS & ONLY WHEN IT
HAS THE ENGINEER OF RECORD'S RAISED
SEAL. COPIES ARE NOT DEEMED VALID.
THIS DOCUMENT IS THE PROPERTY OF
R. A. DUNLEA, P.E. AND SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN CONSENT OF
R. A. DUNLEA.
R. A DUNLEA, P.E.
1513 CERVANTES PLACE
THE VILLAGES, FLORIDA 32159
(772) 285-6444, (352) 750-6207
bobdunlea(ab-centurviink.net
FLORIDA P.E. Lic. No. 42835
_"'ITE SPECIFIC DRAWING -�
MOBILE HOME MOBILE HOME
NOTE: THE LEFT 12" OF THE POLY ROOF WILL BE
ON TOP OF THE SHED WALL. THE POLY ROOF
WILL BE SECURED TO THE TOP OF THE SHED
WALL WITH LAGS AS SHOWN ON ITEM 9, SHEET 3.
THERE SHALL BE NO STRUCTURAL ATTACHMENT
BETWEEN THE POLY ROOF CARPORT AND THE
MOBILE HOME BUT IT IS ACCEPTABLE TO INSTALL
FLASHING TO KEEP THE RAIN OUT.
3" -1 LB. POLY ROOF W/ 0.024" SKIN
CB1
NOTE: TO STABILIZE THE POLY ROOF BEAMS, RBI,'
HAVE BEEN PUT IN PLACE TO ALLOW FOR KNEE
BRACES TO BE INSTALLED BETWEEN THE ROOF
AND THE COLUMNS, AS SHOWN ABOVE IN THE
RIGHT SIDE ELEVATION VIEW. THE KNEE BRACES
SHOWN HERE SHALL ALSO BE INSTALLED IN THE
MIDDLE SECTION. THERE ARE A TOTAL OF EIGHT
(8) KNEE BRACES. THE KNEE BRACES SHALL BE
ATTACHED TO THE COLUMNS AND THE ROOF
BEAMS WITH CHANNELS, AS SHOWN ON SHEET 4.
RBI
RB 1-> ■ <-2x4H
3" -1 LB. POLY ROOF W/ 0.024" SKIN
12" OVERHANG ON FRONT & RIGHT SIDES
16'-0"
PLAN VIEW
1 II 11
3" 7'-7.5" 311 7'-7.5" 3"
FRONT ELEVATION VIEW
(BACK VIEW IS SAME AS FRONT EXCEPT 6" TALLER)
I 8'-6"
10'-0"
8'-0"
RIGHT SIDE ELEVATION VIEW
(SAME BRACES AT THE CENTER OF THE CARPORT)
KNEE BRACE DETAIL
Qp BEAMAR tER f'ER B 2 � HM
<-COLUMN PER TABLE 1 CHANNEL
tI TOTAL FOUR 2x3X0.070, BACK END
�s
s z sms MITERED Wl 1l8"
24" U-CLIP, (6) #12 SMS
INTO COLUMN / CARRY
BEAM, (3) #12 SMS
INTO EACH SIDE OF
KNEE BRACE (TYP.)
■
CHANNEL
NOTE: KNEE BRACES SHALL BE 2x3x0.07 MEMBERS AND SHALL BE 2'-10"
LONG. EACH END SHALL BE CUT ON A 460 ANGLE. THIS ALLOWS FOR
EACH END TO BE 2'-0" FROM THE CORNER.
NOTE: THE KNEE BRACES (KB) WILL BE ATTACHED TO THE COLUMNS AND
CARRIER BEAMS USING A 2"x2.257x2"x0.125" THICK CHANNEL AS SEEN ABOVE.
THERE WILL BE SIX (6) #12 SMS BETWEEN THE COLUMN AND THE CHANNEL
AND BETWEEN THE CARRIER BEAM AND THE CHANNEL AND BETWEEN THE
BRACE AND THE CHANNEL, 3 ON EACH SIDE, AT EACH END OF THE KNEE
BRACE. A TOTAL OF TWENTY-FOUR (24) SCREWS FOR EACH KNEE BRACE.
TWO (2) 318" BOLTS CAN BE USED FOR EACH SIX SCREW CONNECTION. j
POLY ROOF CARPORT
DWG. 9 RVC-2017-107, REV. 0
November 22, 2017
SHEET 2 OF 3
SITE DESIGN DRAWING
HEIGHT 8'-0", 150 MPH, EXP.'C'
R V CONSTRUCTION
3318 COLUMBRINA CIRCLE
PORT ST. LUCIE, FL 34952
OFFICE (772) 380-8253
LICENSE # CRC 1330965
LOCATION:
NAME:
CONSTANZO RESIDENCE
ADDRESS:
8513 LIDFLOWER COURT
CITYISTATE:
PORT ST. LUCIE FL 34952
COUNTY:
ST. LUCIE
THIS REVISION CORRECTS THE WIDTH
OF THE CONCRETE SLAB AND THE
WIDTH OF THE POLY ROOF, AND ALSO
CORRECTS THE EDGE OF THE SLAB AT
THE LOWER LEFT CORNER OF THIS
SHEET. A NOTE IS ADDED TO CONFIRM
THE DISTANCE BETWEEN THE BUCKET
CONNECTION AND THE EDGE OF THE
SLAB. SEE SHADED AND CIRCLED
CORRECTIONS. ONLY THIS SHEET IS
AFFECTED BY THESE CHANGES.
DRAWINGS NOT TO SCALE
R. A DUNLEA, P.E.
1513 CERVANTES PLACE
THE VILLAGES, FLORIDA 32159
(772) 285-6444, (352) 750-6207
bobdunlea(ab-centurviink.net
FLORIDA P.E. Lic. No. 42835
£ I1 1EE'TfQl11 T4 STRUCTURE
311f0D OR :CON.C'RETE
SEE GENERAL' P1Cu -c=� G 'flR sIMii ATiGM
BOLT 3@ 1o, O.C:. & E Nns-,az! SOUND.
ARE FASCU�• LS'eu I �A Y FAS FFJRED -O .
srF :►Nr7li. t i l ' X`3?: LAG TAN•. CElT
AaS lC RAFTE1 -RS ENSUKt., 2:`i llnp rgvc I nnl,.,l,
PRE=DRIL, HQ1=TD�A1/O� SPLITING
CONCRETE .
Fn
OR FELLED
MASONIC&
OR 7R S.S. R 4}�EZj
5Y4�'nxrl'n/� L3 pEEMBED .-
IAPC ON IV' l
& 4%.. FARM'
ENDS BALMAX @16^
G-ELASr&NG -
SEALED , O,
WALL. YP)
EL•* i-E
I EP-13
2'NONIINALSTRUCTURAL— `cult
FACIA MINIMUM EP-23
EMBED
a14AV SMS @ 7- O.C- (a) PER 4' PANEL TOP &/ °NUIF�:ItS 'E �'�`9L 4% FROM
BOTfOP4 ADD (Z) SMS 2' 4' FROM EACH TAPCONS, 2� �4jf' FROM BUDS,
ENCLOSURE ENO TOP B. BOTTOM. HEAVY
14' MAX O.C. TO HOLLOW BLACK
ADHE'SCVE CAULK TOP & BOTTOM CONTINUOUS
ENCLOSURE T O CONCRETE 13'
AivC i-`iOrN� DET.IL
*SEE GENERAL NOTE t10 FOR A
COLL14N• PE-R TAf34ZS OR 3' x3'x3--'gib' ANGLE VM i (2) V/i Xs A' EMBED.
SEA ED. SITE SPECIFIC TAPCONS w/ W MIN. WASHER DIAMETER. TO
DRAWINGSICALCULATIONS SLAB, 2%- APART & 3- FROM SLAB EDGE & (fi)
014 SMS TQ CQLUNN, %' FROM ANGLE EDC,I=S;
ONE EAGki SIDE OF CDLIIMN
, 1 O
Jl n O
,O
pil ly NG CONS1J1$ & FOOTING. SEE SITE SPECIFIC
DETAtjlD AODTTIGIAL FOOTING ENGMEERING SHEET
:SAVE 13EAM CONNeCTION @ WALL
SEE C:NERAL NO -II= 31 D FOR LIMB T10
EPS POLY (USED AS RBQURIED WHEN
CONNECTING TO WALL)
1/4 7HRUSOLTTHROUGH
2"s3`A- ANGLE TO ROOT,
o n g"y3 • ANGLE FASTENED TO INSIDE @
_ - BOTTOM OF CARRY BEAM W/ (2)
L7- THRUAOL7S SIDE, (5) 414 SM9 Bar-f
-i E S IO BEAM PEED FASTENED TO CBS WALL W/ (2) �ii X3 /s'
EMBED TAPCONS OR TO WOOD (MIN -2X,
_. _ SPEL�FIC _rNT' RtfY BY OTHERS) WITH (3)r14xl%'
E
IhIC-
5i
ONS
Sria9?-
iIC,N
r Tf?. -1
IJSE.
MlCEL
I 2 x 3
ENSOfYs
BOX
tGIFiED
ri SEAM
TO 3E
I
1
,
.055,
YP. I
( 2:t3
I
Ri 3c}la
r 2-0'
IEx�FINi .f r LrRLisi ;
A�-ia'•:ALJ Taif�ll M'''boom
•�•--•'3" SOU}.r.•4;
TOP ("IYP 3GTMM)
SEETABLL_Ba OW
Ch
FM 2 x VARY
IJ=P SEN4
F,
ROMDF j'Ai - - ON' —' I Ors
FRONT E LEV„ i O
,r1-Nt�cuS_ = , _ tdiN :coy ray :_ :ER,
SECT! �•--11 V :;i I-83EXR.� NG
COLUMN
CCU LI•--7t 1
(OPT-) a
a
OPTEON 1,USE Y4 LAG BOLTS
W/ 1` MM WASHER OIAMErEP,
1' lMR4. LONGER THAN PANEL.
T1 GCKNESS SPACED PER LAG
SPACING TABU THIS OfFrA51.-
OPTION 2: L4' THRUBOLTS TO
ROOF, 4" FROM ENDS & 17'
O.C. TO 2-x2'X�' ANGLES
(E3i HFSL SIDE IF REQUIRED BY
BUILDING DEPT).
E(P.
LAG =PAGING-
I j4',O.a24'1
TaSI.
l�p 3
I
°rJr
i - G.C.
-' 0.i=-
0 3
11�
PSr
i°• PER
I Pc4
At
_-ia 5
.?ANEL
L pGO C931�3=
O G
1[1' O.C.
1=a C
a
PAS
, ?.4 E8
a�UC4q
lsa c
SMS a.
i1'P. TOP -A EOM
'NL = WALL LOAD
RL= ROOF LOAD
1 ° CARRY BEAM PER TASI ES OR
sEN-ED-SITE SPECIFIC
DRAWINGQCxL CULATIONS
BM OFTIONs: (2)%'THRUBOLTS,
CARRY SEA. M TG COLUMN
NOTCH_aOWHt IN C33fTEt TO FIT
'an.,
CARRY 13501 SNUG
SO T H OPTIONS: 3°Y3'*s' .ANGLE, (Ei)
�14 SMS EA LEI;, r A SIDE OF COUMN
COLUMN PER TABLES OR SEALED
SPECIFICDRAWING/G1L:CULA,TIONS
moms
SECTION. AT SIDE -OF R00-F PANEL
h' LAGS, 4` FROM -NOS & 24' MAX O.G, I° h "
rLONGER THAN PANEL 7HIQJ4�S TO SECURE F=F
TO NON -PRIMARY WALLS ONLY- CAULK ALL Scpu l l
SMS 16, HEADS
7(P. TOP &
BO fq . °
EXFE ROOF
° PANEL
EL2ic°" a 2x2BOX
ENO GIP MIN.
OR �.
11W E1NCc a 2 �2'xya' ANGLE, (3] 114 SZ S EA
LEG, EA SIDE OF SEAM
C
1 1
BEA •SPLICE
OVER COLUMN .
IIJE
(1) is' LAG WLT2.N}'a.
rSEF
5.Cii CARRY BEAM -I%i;
T gLE
(5) �14 SMS EA 1' NON LONGER. THAiR'••••
BELGYICI
DE OF PLATE PPPIEL kffCKNE55
6"Mal 5. 4 self
�14 SMS
® SiGS
,
Z4
O.C.
MAX 70P
GtR't6.3EAld'
WZE K.%-1 i laCF.��
SIDE OF
.-OIJMN P.ERTA--ILES tit
SECTION AT BEARING
COLUMN ,
- - #12XY4" SMS @
16" TYP- TOP &
BOTTOM
0
c o EPS POLY
0 0 o a ROOF
o' o 0
ELITE TYPE 'Ev % / 12
GUTTER OPTIONAL SLOPE
ADAPTOR
SHOWN
USE Y," LAG BOLTS W/ 1" MIN.
WASHER DIAMETER, 1" MIN. LONGER CARRY Bq,'
ABLES
THAN PANEL THICKNESS SPACED
'1t+/F9'EN.FAS 1TffQN�F�
:aL' EJMINUW ttSE TRl UFA<5TH£tx
('r ; 3147) AT 8.` O.Is. FQR UP•
i a i30 •MPF{•)/Y ND 8PEED
LXPOSURE "D�; ir' O.E. FOR
ABOVE130 MPI- ikjVD UP I O
_1� MPH VONa-SPEED
E,'POSUR-E`D'
CAUUK ALL EXPOSED SCREW
=HEADS & W,4SHERS
- -
....
ROOF-PA-14EL T-b BEAM E
FOR _G0MPOS1i E .ROOFS:
#10 x (t -r 1/2"j6iKS: W/
1-1/4-0 FEPIDER ;.WASHERS
:@-12` L1.4,.-lt }.
PA14EL TrilCKI
- ` @ ROOF BEARING
(SH04YPI) iAPl�.244'GG_
i�lON-NONELEME14T (SIDE
W
FOP. PAN_ ROOFS:
(•3jEACH Ajax 1/2"•L'.ONG S_ftt)_
RER 12'.PATEEr f1374"
-ALE11vfwu Pvi° Pi4I+IliVAS.HER
ffObFPA'NE* L
S0PPORFfNG BEAM
EN'I1� ;DE�'�
3x3 POST-->
BUCKET THICKNESS
NOTE: THE TAPCONS CAN. BE REPLACED
MUST BE 118 MIN
WITH TWO (2)1/2" WEDGE ANCHORS
s
(REDCAP, HILTI, OR EQUAL) WITH 2-1/4-
#14 SMS,
MINIMUM EMBEDDMENT. ALSO, IF BUCKET
3 SMS
3x i1C -
IS BEING ATTACHED TO WOOD USE THE 3/8"
PER SIDE
- 3" WOOD SCREWS, W/ 1-114" WASHERS,
(6 TOTAL)
`
TO SECURE THE BUCKETS. WEDGE ANCHOR
MUST BE EQUAL OR HIGHER STRENGTH.
CONCRETE TWO (2)
3/8" - 3" CONCRETE
--LDT38212-> TAPCONS 2-1/4"
(OR EQUAL) (MIN. EMB.=2-1/4")
2"Min. 3" x 3" BUCKET CONNECTION
POLY ROOF CARPORT
DWG. # RVC-2017-107, REV. 0
November 22, 2017
SHEET 3 OF 3
POLY ROOF CONNECTIONS
HEIGHT 8'-0", 150 MPH, EXP. 'C'
R V CONSTRUCTION
3318 COLUMBRINA CIRCLE
PORT ST. LUCIE, FL 34952
OFFICE (772) 380-8253
LICENSE # CRC 1330965
LOCATION:
NAME:
CONSTANZO RESIDENCE
ADDRESS:
8513 LIDFLOWER COURT
CITY/STATE:
PORT ST. LUCIE FL 34952
COUNTY:
ST. LUCIE
THIS "CIRCLED" CONNECTIONS
ON THIS SHEET ARE BEING
USED FOR THIS PROJECT.
1 2 3
4 5 6
7 8 9
10 11
NOTE: DRAWINGS ARE
NOT TO SCALE
R. A DUNLEA, P.E.
1513 CERVANTES PLACE
THE VILLAGES, FLORIDA 32159
(772) 285-6444, (352) 750-6207
bobdunleaCa)centurvIlnk.net
FLORIDA P.E. Lic. No. 42835
♦eo40 01HON�,O�r,
••••••
)NAL