HomeMy WebLinkAboutEVALUATION REPORT ADHESIVES POLYSETS
�1 TRINITY I ERD
EVALUATION REPORT
ICP Adhesives and Sealants, Inc.
12505 NW 44th Street
Coral.Springs, FL 33065
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization 119503
353 CHRISTIAN STREET, UNIT 13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report 02768.03.06-R7
FL6332-R7
Date of Issuance: 08/08/2008
Revision 7: 06/16/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with
the 5th Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: ICP Adhesives Polyset® AH-160
LABELING:. Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words. "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request,, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 06/16/2016. This does not serve as an electronically signed
document. Signed, sealed hardcoples have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest
in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity] ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
�d®� allg
QOTRINITYIERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roof Tile Adhesives
Compliance Statement: ICP Adhesives Polyset° AH-160, as produced by ICP Adhesives and Sealants, Inc., has
demonstrated compliance with the Florida Building Code through testing in accordance with the Standards set forth
herein. Compliance is subject to the Installation Requirements and Limitations /Conditions of Use set forth herein.
2. STANDARDS:
Sections
Property
Standard
Year
1505.1
External Fire Classification
ASTM E108
2007
1711.2.1
Wind
SSTD 11
1997
3. REFERENCES:
Kniitf
Examination
Reference
Date
ERD (TST 6049)
SSTD 11
P39740.02.12
02/20/2012
ERD (TST 6049)
SSTD 11
P39740.11.13-R1
01/02/2015
ICC-ES (EVL2396)
2012 IBC Compliance
ESR-1709
12/01/2014
ITS (TST 1585)
ASTM E108
101646522SAT-001_Rev. 1
12/23/2014
Miami -Dade (CER 1592)
HVHZ compliance
16-0315.01
04/07/2016
PRI (TST 5878)
SSTD 11
ECM-001-02-01
09/21/2001
FRI (TST5878)
SSTD 11
PFI-006-02-01
05/09/2005
PRI (TST 5878)
SSTD 11
PFI-006-02-02
05/09/2005
PRI (TST 5878)
TAS 101
PFI-007-02-01
10/11/2005
PRI (TST 5878)
SSTD 11
PFI-008-02-04
02/21/2006
PRI (TST 5878)
SSTD it r
PFI-009-02-03
02/21/2006
PRI (TST 5878)
SSTD 11
TGRI-001-02-03
10/30/2006
PRI (TST 5878)
SSTD 11
TGRI-001-02-03
10/30/2006
PRI (TST5878)
SSTD 11
PFPI-010-02-01
12/07/2006
PRI (TST 5878)
SSTD 11
PFPI-011-02-01
12/07/2006
PRI (TST-5878)
SSTD 11
PFPI-012-02-01
12/07/2006
PRI(TSf5878)
SSTD 11
PFPI-013-02-01
12/07/2006
PRI (TST5878)
SSTD 11
PFPI-014-02-01
12/07/2006
PRI (TST 5878)
TAS 101
ECM-003-02-01
06/13/2008
PRI (TST 5878)
TAS 101
ECM-004-02-01
06/13/2008
PRI (TST 5878)
TAS 101
ECM-005-02-01
06/13/2008
PRI (TST 5878)
TAS 101
ECM-006-02-01
06/13/2008
PRI (TST 5878)
TAS 101
ECM-007-02-01
06/13/2008
PRI (TST 5878)
TAS 101
ECM-008-02-01
06/13/2008
UL LLC (QUA 9625)
Quality Assurance
Service Confirmation
Exp. 06/05/2018
4. PRODUCT DESCRIPTION:
4.1 ICP Adhesives Polyset® AH-160 is a two -component expanding polyurethane roof tile adhesive that is mixed
and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are
available.in refillable tanks or disposable cylinders (ICP Adhesives ProPack® 30 & 100).
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in anyway, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for
permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-R7
Certificate of Authorization #9503 F1.6332-1117
Revision 7: 06/16/2016
Page 2 of 9
QOTRINITYIERD
5.3 Concrete and clay tiles, having a current Florida Statewide Product Approval or approved on a local -level by
the AHJ, adhered using ICP Adhesives Polyset® AH-160, maintain their respective roof fire classifications.
Refer to FBC 1505.2, Exception 2.
5.4 ICP Adhesives Polyset® AH-160 can be used with flat, low and high profile tiles or any rigid, discontinuous roof
assembly having a current Florida Statewide Product Approval or approved on a local -level by the AHJ.
5.5 Minimum underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide
Product Approval or approved on a local -level by the AHJ for use with ICP Adhesives Polyset® AH-160.
5.6 Field .tiles using ICP Adhesives Polyset® AH-160 are limited to projects having an Aerodynamic Uplift Moment
(Ma), determined in accordance with FBC 1609.5.3 or Tables 2A and 2B of FRSA/TRI April 2012 (04-12), not
greater than the following Allowable Overturning Moment values. Refer to Section 10 and ICP Adhesives and
Sealants, Inc. published installation instructions for Adhesive Paddy Placement.details.
TABLE 1: HELD TILES IN ICP ADHEsIvEs POLysETO AH-160
ALLOWABLE OVERTURNING MOMENT PERFORMANCE DATA
2TO1 MARGIN OFSAFETY.ALREADYAPPUED FDA INDEPENDENT (SINGLE, PA CONTINUOUS PADDY) PLACEMENT
4 Tot MARGINOFSAFETYALREADYAPPUED FOR INTERDEPENDENT (TWO PADDY) PLACEMENT
Tile
Adhesive Paddy Placement
Allowable
Overturning
Type
Profile
Moment (ft-lbf)
Independent; Single Paddy, Medium (2x7-inch, ^30 gram)
60
Clay
Flat
Independent; Single Paddy, Large (WO -inch, -45 gram)
112
Concrete
Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch at tile overlap)
54
Independent; Single Paddy, Medium (2x7-inch, -30 gram)
39
Clay
Low/
Independent; Single Paddy, Large (WO -inch, -54 gram)
67
te
Concrete
Medium
Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at tile overlap)
58
Clay
High
Independent; Single Paddy, Large (WO -inch, -45 gram)
134
Independent; Single Paddy, Medium (2x7-inch, -30 gram)
65
Concrete Clay
High
Independent; Single Paddy, Large (WO -inch, -63 gram)
109
Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at tile overlap)
40
Clay
Barrel
2x10-inch x -35 gram for pans; 2 @ WO -Inch x -17 gram for cap
147
Concrete
Barrel
2x10-inch x -3. 5 gram for pans; 2 @ WO -inch x ^17 gram for cap
107
Clay
Cap atop 2z
Independent: Continuous Paddy (^34 gram/ft)
135
stringer
Concrete
Cap atop 2x
t d Inde enen:,ContinuousPaddy
a
py (" 34 gram/ft)
116
stringer
ClayCap
atop 2x
Interdependent:
105
stringer
Head: One (1) H10 x 2%" screw; Overlap: 1 x 6 inch ("10.5 gram)
Concrete
Cap atop 2x
Interdependent:
76
stringer
Head: One (1) N10 x 2#" screw; Overlap: 1 x 6 inch (-10.5 gram)
5.6.1 Data in Table 1 relates to installation over a '30/90' underlayment system, as detailed in the FRSA/TRI April
2012 (04-12). Alternate underlayment systems include those having a current Florida Statewide Product
Approval and/or approved on a local -level by the AHJ specifically for use with ICP Adhesives Polyset° AH-160.
5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with
ICP Adhesives Polyset® AH-160 shall be tested in accordance with SSTD 11 or TAS 101. For the
interdependent two -paddy method, an additional 2-to-1 margin above that specified in SSTD 11 or TAS 101
shall be applied in determining the'allowable overturning moment'.
Exterior Research and Design, LLC., Evaluation Report 02766.03.06-R7
Certificate of Authorfzation ii9503 FL6332-R7
Revision 7: 06/16%2016
Page 3 of 9
S
5.7 Hip and ridge tiles using ICP Adhesives Polyset® AH-160 are limited to projects having hip/ridge design pressure
requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), .not greater than the
following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive
Paddy Placement details.
TABLE 2: HIP & RIDGE TILES'IN ICP ADHESIvEs POLYSET® AH-160
ALLOWABLE.UPLIFT_ RESISTANCE PERFORMANCE: DATA. �
2 01MARGINOFSARTYALREADYAPPIIEDFOR.INDEPENDENT,(CONTINUOUS'PADDY)PLACEMENr
', •. -„ - _ 4T0'IMARGINOFSAFEIYALREADYAPPLIEDFOBINTERDEPENDENT PLACEMENT _ ,
Allowable
Tile
Substrate
Attachment Method
Design Pressure
(Psf)
Clay
2x-PT ridge board
Independent: Continuous Paddy ("'34 gram/ft)
116
Concrete
2x,PT ridge board
Independent: Continuous Paddy 1— 34 gram/ft)
107
Clay
2x PT ridge board
Interdependent: Head: One (1) #10 x 2W screw;
90
Overlap: 1 x,6 inch (-10.5 gram)
Concrete
2x PT ridge board
Interdependent: Head: One (1) #10 x 2%" screw;
56
Overlap: 1 x 6' inch (^'10.5 gram)
Clay or
Hip & Ridge Channel Metal (FL5374):
Independent: Continuous Paddy (^ 34 gram/ft)
169
Concrete
galvanized only
Clay or
Trim Lock'" (FL5374): aluminum,
Independent: Continuous Paddy (^34 gram/ft)
173
Concrete
galvanized, Galvalume® orstainless:&eel
Clay or
Trim Lock m Plus (FL5374): aluminum,
Independent: Continuous Paddy 34 gram/ft)
178
Concrete
galvanized, Galvalume0 or stainless steel
Clay
Top Notch (FL8095)
Independent: Continuous Paddy (^ 32 gram/ft)
125
Concrete
Top Notch (FL8095)
Independent: Continuous Paddy 32 gram/ft)
146
6. INSTALLATION:
6.1 ICP Adhesives PolysetO AH-160 and the the roof assembly shall be installed in accordance with FRSA/TRI April
2012 (04-12) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the limitations
outlined in Section 5.
6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04-12).
Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product
Approval.
6.3 Installation shall be performed by applicators who hold a valid Qualified. Applicator Card presented by ICP
Adhesives and Sealants, Inc.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product..
8. MANUFACTURING PLANTS:
Tomball, TX
9. QUALITY ASSURANCE ENTITY:
UL LLC — QUA9625; (414) 248-6409; Karen.buchmann'@us:uLCom
Exterior Research and Design, LLC. Evaluation Report 02768.03.06-R7
Certfcote oJAuthorization #9503 FL6332-117
Revision 7: 06/16/2016
Page 4 of 9
Q0TRINITYIERD
10. PADDY PLACEMENT DETAILS (FROM ICP ADHESIVES AND SEALANTS, INC. PUBLISHED LITERATURE):
101 Indeaendent, Medium Paddy:
Nail through plastic cement
(when required)� /
Underlayment
0
7m.i 2 tn.
Battens optional °
Eave Course
a Q
10 in
Eave Closure
`Paddy (Beneath Tile)
1
Flat/Low Profile Tile
Nail through plastic cement
(when required)
Paddy (Beneath Tile)
Underlayment
t ,
h
`
Battens optional
10in.
2in.
Eave Closure
Eave Course
Fascia
Medium Profile Tile
Nail through plastic c e
(when required)
Paddy (Beneath Tile)
nderiayment
11
It
r
2 in.
Battens
optional
r Eave Course `'�
�
Fascia
"r
Weephole
loin.
Eave closure
�2in.
Drip edge
High Profile Tile
Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-R7
Certificate of Autho►kation N9503 FL6332-117
Revision 7: 06/16/1016
Page 5 of 9
0
10.2 Independent. Lareae Paddy:
Nail through plastic cement
(when required)
Undedayment ° j
o `
10 in>�#,
optional °
rrso
10 in
Eave Close
Flat/Low Profile Tile
(Beneath Tile)
QOTPJNITYIERD
Nail through plastic cement
(when required)
Paddy (Beneath Tile)
Undedayment>^�
10 in.x
%.
2in.wide
Battensoptional
r
10 in. 2in.
Eave Closure
Eave Course Fascia
Medium Profile Tile
Nail through plasticce n
(when required) Paddy (Beneath Tile)
Underlayment
10in. x
2 in. wide
x
Battens
optional
��
: " T
Eave Course, Fascia
Weephole
10 in. �2 in.
Eave closure
/c Drip edge
High ProfileTlle
Exterior Research and Design, I.I.C. Evaluation Report 02766.03.06-117
Certificate of Authorization p9503 FI.6332-117
Revision 7: 06/16/1016
Page 6 of 9
0
0.3 Interdependent, Two Paddy:
Nail through plastic cement Paddy (between tiles)
(when required)
Battens optional
o Paddy (undertile)
Singlepaddy,
on top of the
tia Z,
4x4in. +,"�,
Singlepaddy \ ,
utuler tilf�
Single paddy
on underlayment 2 x 4 in.
o /
loin
Eave Closure
Flat/Low Pro
Exterior Research and Design, I.I.C.
Certrimte of.Authorfration A9503
'ileTile
QOTRINITYIERD
Nail through plastic cement Single paddy under tile
(when required)
Paddy (between, tiles)
Battens Paddy (under'tile)
(optional
W � t
Single paddy
.��ontop oftile
�
x4in. 2x4m.
Single paddy on °
underlayment
10in. 2in-
Eave Closure
Eave Course Fascia
Medium ProfileTile
Nail through plastic cement -,,Single paddy under tile
(when required)
Paddy (between tiles)
Battens °
optional
�w
Paddy (under tile)
Single paddy �.
o.n underlayment e
4x4 in.
r
Single 2x4in.
paddyon
top of tile ?�
Eave Course
Fascia
Weephole
I O in. in.
E
y fit
Drip edgelosure
High ProfileTile
Evaluation Report02768.03.06-R7
FL6332-R7
Revision 7: 05/16%2016
Page 7 of 9
n
10.4 . Two Piece Barrel (Cap & Pan) Tile:
11 Place enough adhesive to achieve .65.to 70:
In contact with the pan tile.
2) Turn Covers upsidedown. Place adhesivo
92 in, tot inch in from outside edge of cover tile.
. Install cover tile.
Ensure 20 to 25 sq. in. contact aroa on
each aide of 'cover tile.
Unde�layment r '
Gi a
(motar,shown)
Steep pitch applications
(when required)
- - Fascia Board------'-,,,J
Remove top portion of the eave course'cover tile.Abutto second course of
pan tiles. Ensure'eave end of pan and cover tiles are flush at eave line.
Two Piece Barrel - High Profile Tile
10.5 Hip' and Ridne (independent placement):
A bead ofICP Polyset9ARtl60 may be applied above the Md To attach hVridae On, a bead ofiCPPolysetV M-I60 may
the surface on both sides of the luphidge bond or galviaced bs applied do" Ilie c:rM oftha luptsidge booed or gahiniaed
merat franc to provide Lime
Exterior Research and Design, LLC.
Certificate ofAuthod:ation #9503
QOTRINITYIERD
Evaluation Report02768.03.06-R7
FL6332-R7
Revision 7: 06/16/2016'
Page 8 of 9
10.6 Hip and Ridge (interdependent placement):.
- END OF EVALUATION REPORT-
Exterior Research and'Design, LLC.
Certificate oJAutharfzation A9503
QOTRINITYIERD
Evaluation Report02768.03.66-117
FL6332-R7
Revision 7: 06/16%2016
Page 9 of 9
1