Loading...
HomeMy WebLinkAboutLETTER - MATERIAL CERTIFICATIONHERITAGE 11ty 1 .. ING SYSTEMS°o FstabUshed.1979 An NCI Company October 09, 2017 ROBERT SANTOM 15339 TWIN BEECH PKWY PORT SAINT LUCIE, FL 34987 16-B-18275 ROBERT SANTOM 15339 TWIN BEECH PKWY PORT SAINT LUCIE, FL 34987 5.2'-0" x 52'-0" x 16'-0" To Whom It May Concern: This is to certify that materials for the subject structure have been designed in accordance with the order documents., specifically as shown per the attached Engineering Design Criteria Sheet. Aspects of code compliance as related to use or occupancy, such as sprinkler requirements, are not addressed by these documents. These materials, when properly erected on an adequate foundation in accordance with the erection drawings as supplied and using the components as furnished, will meet the attached loading requirements. This certification does not cover field modifications or the design of materials not furnished by Heritage Building Systems. The attached design criteria information is to remain with and form part of this Letter of Certification. The calculations and the metal building they represent are the product of Heritage Building Systems or a division of its affiliate NCI Building Systems. The engineer whose seal appears hereon is employed by either Heritage Building Systems or a division of its affiliate NCI Building Systems and is not the engineer of record for this project. Cordially, Heritage Building Systems Materials for Metal Buildings An NCI Company Aaron K. Batchellor, P.E. Manager of Design IIIitI#J' Jf #. �,.•BATGy��'. J. SWE O • -• lor- *''ss/OMAL E�''t 111111111 /O--I�"I'] 16-B-18275 Page 1 of 2 HERITAOE � ;SLTILD:ING .�SYSTE1ViS�o Estali&hed 197-4 An NCI Company l Building Code ....................... FBC 14 Risk Category ........................ II - Normal Roof Dead Load Superimposed .................... 2.270 psf Collateral ...................... 1.000 psf Roof Live Load .....................:. 20.00 psf (Reducible) Snow Wind area. Ground Snow Load (Pg)........... 0.0000 psf Snow Load Importance Factor (Is) 1.0000 Flat Roof Snow Load (Pf)........ 0.00 psf Snow Exposure Factor (Ce)....... 1.00 Thermal Factor (Ct)............. 1.00 Ultimate Wind Speed ................ 160 mph Nominal Wind Speed (Vasd).......... 124 mph (IBC Section 1609.3.1) Serviceability Wind Speed ......... 87 mph Wind Exposure Category ......... C Internal Pressure Coef (GCpi) 0.18/-0.18 Loads for components not provided by building manufacturer Corner Areas 59.335 psf pressure-79.297 psf-suction Other Areas 59.335 psf pressure-64.363 psf suction These values are the maximum values required based on a 10 sq ft Components with larger areas may have lower wind loads. 16-B-18275 Page 2 of 2