HVAC Load Calculations
for
Ken Cooper
6740 N. Hwy. A1A
Fort Pierce, FL. 34949
Prepared By:
Mike Thornton
Smith Services, Inc.
1306 29th Street
Vero Beach, FL. 32960
(772)770-3300
Tuesday, November 28, 2017
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
�ecciaLHVAG Loads �, _ d , tuzea:
1 vero,beacn�rru �3Z5bu
Project Report
Project Title:
Designed By:
Project Date:
Client Name:
Client Address:
Client City:
Company Name:
Company Representative
Company Address:
Company City:
Company Phone:
Cooper
Smith Services, Inc.
Friday, September 01, 2017
Ken Cooper
6740 N. Hwy. A1A
Fort Pierce, FL. 34949
Smith Services, Inc.
Mike Thornton
1306 29th Street
Vero Beach, FL. 32960
(772) 770-3300
Design'. Data-,,,,"
Reference City: Fort Pierce, Florida
Building Orientation: Front door faces West
Daily Temperature Range: Medium
Latitude: 27 Degrees
Elevation: 25 ft.
Altitude Factor: 0.999
Outdoor
Outdoor
Outdoor
Indoor
Indoor
Grains
Dry Bulb
Wet Bulb
Rel.Hum
Rel.Hum
Dry Bulb
Difference
Winter: 42
39.4
n/a
n/a
70
n/a
Summer: 90
78
59%
50%
75
61
Check Fi ores, �.x
Total Building Supply CFM: 2,358 CFM Per Square ft.: 0.708
Square ft. of Room Area: 3,333 Square ft. Per Ton: 574
Volume (ft'): 36,510
Total Heating Required Including Ventilation Air:
43,120
Btuh
43.120
MBH
Total Sensible Gain:
52,283
Btuh
92
%
Total Latent Gain:
4,449
Btuh
8
%
Total Cooling Required Including Ventilation Air:
56,732
Btuh
4.73
Tons (Based On Sensible + Latent)
5.81
Tons (Based On 75% Sensible
Capacity)
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhvac Residmm ential & Light Coercial HVAC Loads
Smith Heating & A/C
Elite Software Development, Inc.
Cooper,
VeroBeacki; FL 329fi0 a� -:-.
' Fa e 3;
Miscellaneous Report
System 1 System 1 OutdoorOutdoor :Outdoor Indoor 9, N Indoor Grams"
Iri ut ,,,,,Data,-,,' Bulb z. s °ReI:Hu'm , ° Rel,Hunp- D r :Bulb Difference,
. .
Winter: 42 39.4
80% n/a 70 n/a
Summer: 90 78
59% 50% 75 61.09
System 2 System 2 Qutdoor; ;Outdoor' Outdoor Iridoorj,' 9 Indoor Grains"
In' ut Data; �ti.,..;� ,� , �° �D r,Bulb-_�. .. UUet Bulb a..:, .ReLHurn„ - :° ReLHum ` �. OrF,Bulb, :- .Difference
Winter: 42 39.4
80% n/a 70 n/a
Summer: 90 78
59% 50% 75 61.09
Main Trunk
Runouts
Calculate: Yes
Yes
Use Schedule: Yes
Yes
Roughness Factor: 0.00300
0.01000
Pressure Drop: 0.0800 in.wg./100 ft.
0.0800 in.wg./100 ft.
Minimum Velocity: 650 ft./min
450 ft./min
Maximum Velocity: 900 ft./min
750 ft./min
Minimum Height: 0 in.
0 in.
Maximum Height: 0 in.
0 in.
0utsidewAi"Data : let"
Winter
Summer
Infiltration Specified: 0.100 AC/hr
0.100 AC/hr
61 CFM
61 CFM
Infiltration Actual: 0.100 AC/hr
0.100 AC/hr
Above Grade Volume: X 36,510 Cu.ft.
X 36,510 Cu.ft.
3,651 Cu.ft./hr
3,651 Cu.ft./hr
X 0.0167
X 0.0167
Total Building Infiltration: 61 CFM
61 CFM
Total Building Ventilation: 0 CFM
0 CFM
---System 1---
Infiltration & Ventilation Sensible Gain Multiplier: 16.49
= (1.10 X 0.999 X 15.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: 41.50
= (0.68 X 0.999 X 61.09 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier: 30.77
= (1.10 X 0.999 X 28.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.100 AC/hr (32 CFM)
Summer Infiltration Specified: 0.100 AC/hr (32 CFM)
---System 2---
Infiltration & Ventilation Sensible Gain Multiplier: 16.49
= (1.10 X 0.999 X 15.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: 41.50
= (0.68 X 0.999 X 61.09 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier: 30.77
= (1.10 X 0.999 X 28.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.100 AC/hr (29 CFM)
Summer Infiltration Specified: 0.100 AC/hr (29 CFM)
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
RhvBc Residential & Light Commercial HVAC Loads*Elite
Smith Heatirig & AIC '
Software Development, Inc
Vero Beach,: FL 32960i
Page 4N
Load Preview Report
Net
Rec
ft.'
Sen
Lat
Net
Sen
Sys
Htg
ysi
Sys Act
Duct
Scope
Ton
Ton
/Ton
Area
Gain
Gain
Gain
Loss
CFM
CFM
CFM
Size
Building
4.73 5.81
574 3,333
52,283
4,449
56,732
43,120
561 2,358,
2,358
System 1
2.53 3.10
510 1,581
27,899
2,437
30,336
21,100
274 C^T1,249i 1,249
18
Return Duct
451
0
451
0
Zone 1
1,581
27,448
2,437
29,885
21,100
274'j, 1249
1,249
1-Foyer
315
4,357
279
4,636
4,398
57 ` 198:.
198
7.7
2-Family Room
480
6,428
291
6,719
7,060
92 ! °292 j 292
8,8
3-Dining Room
240
8,011
277
8,288
5,673
74' 364 364
9,9
4-Ktchen
252
6,356
1,008
7,364
2,400,
31.3 . •289,
289
8,8
5-Guest Bedroom
196
1,955
521
2,476
1,191
15� 86!i
89
7
6-Guest Closet
35
262
61
323
286
' 4 ;, 121
12
3
7-Guest Bath
63
80
0.
80
92
1 4;i
4
2
System 2
220, 2.71
647 1,752
24,384
2,012
26,396
22,020
286'?. 1,109
1,109
17
Zone 1 - Clg.: 50%, Htg : 48%
596
12,473
1,104
13,577
10,643 '
138 P' w 567
567
8-Master Bedroom
400
10,620 •
814
11,434,
7,930,
103 i 4831
483
10,10
9-Master Bath
196
1,853
290;
2,143,
2,713
35, 84
84,
6
Zone 2 - CIg.: 50%, Htg.: 52%
1,156
12,656
908
13,564
11,377
148 576
576
10-Master Hall/Closet
140
386
0
386
638
8 j „ 1 W
18
4
11-West Bedroom
196
1,447
145
1,592'
2,198
29 66j'
66
6
12-West Bath
64
553
83
636
816
11 i ° ° 25;i
25
4
13-West Closet
48
52
0
52
70
1 ' ` .. 2;i
2
2
14-East Bedroom 2
325
5,014
335
5,349
3,678
48 1- 228'
228
7,7
15-Hall
60
166
0
166
273
4 `^ , ` �`8'
8
Not TMDD:
1-4
16-East Bedroom 3
224
4,765
345
5,110
3,253
42 ; n 217`
217
9
17-Bedroom 3 Closet
36
99
0
99
164
21 5'
5
2
18-Bedroom 3 Bath
63
174
0
174
287
4 i 81i
8
3
Sum of room airflows may be greater than system airflow because
system has multiple zones.
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhvac Residential& Light Commercial HVAC Loads
Elite Software Development, Inc.
Smith Heafing & A/C
Cooper,
M
Veach;�,FL�32960
Duct Size Preview
Room or
Source
Minimum
Maximum
Rough.
Design
SP
Duct
Duct
I
Htg
Clg
Act.
Duct
Duct Name
Velocity
Velocity
Factor
L/100
Loss
Velocity
Length
Flow
Flow
Flow
Size
System 1
Supply Runouts
Zone 1
0
0
0.01
0.08
0.02303 '
387.5
10
7
1-Foyer (SR-140, SR-150)
TMDD
0
0
0.01
0.08
0.00802 :
387.5
10
57 198•
- :.,
198
i
7
2-Family Room (SR-160,
TMDD
0
0
0.01
0.08
0.00641
428.2
8
92
292
8
SR-170)
0
0
0.01
0.08
0.00641
428.2
8
.i 292
. �w�`r
8
3-Dining Room (SR-100,
TMDD
0
0
0.01
0.08
0.02609
452.9
8
j
74 3fi4'� 3.9
9
SR-1 10)
0
0
0.01
. 0.08
0.02609
452.9
g
=
0
0
0.01
0.08
0.02466
427. 3
` 8
8
4-Kitchen (SR-120, SR-130)
TMDD
0
0.08.
0.02466
427.3,
8
31 289'
�;
289
8
0
0.01
5-Guest Bedroom (SR-180)
TMDD
0
0
0.01
0.08
0.008
378.6,
10
15a 89
7
6-Guest Closet (SR-190)
TMDD
0
0
0.01
0.08
0.00641
221.8
8
4
12•
3
7-Guest Bath (SR-200)
TMDD
0
0
0.01
0.08
0.00639
163.9
8
1 ,a _A
4
2
Other Ducts In System 1
Supply Main Trunk (ST-100)
TMDD
0
0
0.01
0.08
0.32161
737.5
16
276-1;249,�
1,249
18
STA 10
TMDD
0
0
0.01
0.08
0.03578
627.3
1
106 ",654
j 654
14
ST-120
TMDD
0
0
0,01
0.08
0.04052
462.6
25
58 '1,98��
198
9
ST-130
TMDD
0
0
0.01
0.08
0.03915
552.7
15
112
397
11
ST-140
TMDD
0
0
0.01
0.08
0.03301
510.4
10
32 ,:°;29t);
290
10
ST-150
TMDD
0
0
0.01
0.08
0.02507
393.2
12
20 c `"105
105
7
RT-100
TMDD
0
0
0.003
0.08
0.04751
831.4
10
`1
1,249 1249f 1,249
17
RRA00
TMDD
0
0
0.003
0.08
0.01773
831.4
1
1249 '° 249I
1,249
17
System 2
Supply Runouts
Zone 1
8-Master Bedroom (SR-230,
TMDD
0
0
0.01
0.08
0.0064
487. 3
8
103 �° 4$3'�
483
10
SR-240)
0
0
0.01
0.08
0.0064
487.3
8
„w ,
10
9-Master Bath (SR-220)
TMDD
0
0
0.01
0.08
0.00641
371.1
8
35
84
6
Zone 2
10-Master Hall/Closet (SR-2 10)
TMDD
0
0
0.01
0.08
0.00801
247.3
10
8 ' 18'
18
4
11-West Bedroom (SR-300)
TMDD
0
0
0.01
0.08
0.0048
348.5
6
29 6Ei
66
6
12-West Bath (SR-320)
TMDD
0
0
0.01
0.08
0.00799
269.7
10
11 .,s:25
25
4
13-West Closet (SR-310)
TMDD
0
0
0.01
0.08
0.00479 ,
134.9
6
1
2
2
14-East Bedroom 2 (SR-280,
TMDD
0
0
0.01
0.08
0.00639
401.3
8
��`
48 228
228
7
SR-290)
0
0
0.01
0.08
0.00639
401.3
8
7
15-Hall
Built -In
450
750
0.01
0.08
86.5
4 '._ .- 8,
8
1-4
16-East Bedroom 3 (SR-250)
TMDD
0
0
0.01
0.08
0,0064
473.8
8
42 217)
217
9
17-Bedroom 3 Closet (SR-260)
TMDD
0
0
0.01
0.08
0.0048
174.5
6
2 , "•.r' S
5
2
18-Bedroom 3 Bath (SR-270)
TMDD
0
0
0.01
0.08
0.00479
198.3
6
4
I 8
3
Other Ducts In System 2
Supply Main Trunk (ST-160)
TMDD
0
0
0.01
0.08
0.0032
714.5
4
284 1;1,02
1,102
17
ST-170
TMDD
0
0
0.01
0.08
0.04
602.4
50
147 ?w+558
558
13
STA80
TMDD
0
0
0.01
0.08
0.00799
580.8
10
104
484
12
ST-190
TMDD
0
0
0.01
0.08
0.02046
600.4
10
137 m 551:
551
13
ST-200
TM DD
0
0
0.01
0.08
0.0343
523.5
10
89 321
11
ST-210
TMDD
0
0
0.01
0.08
0.0301
479.8
, 10
48 - ._ 228
( 228
9
ST-220
TMDD
0
0
0.01
0.08
0.03447
380.8
' 25
41 93
7
ST-230
TMDD
0
0
0.01
0.08
0.01713
226.5'
15
6,°.1'3)
13
3
RT-110
TMDD
0
0
0.01
0.08
0.0032
715.3
4
1,108 5'; 1',1.08
( 1,108
17
RR-1 10
TMDD
0
0
0.01
0.08
0.01199
504.2
15
277 271<<
277
10
RT-120
TMDD
0
0
0.0003
0.08
0.02253
901.6
25
831
831
13
RR-120
TMDD
0
0
0.01
0.08
0.00478
507.9
6
277 5277
277
10
RR-130
TMDD
0
0
0.01
0.08
0.00957
507.9
12
277,277
277
10
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
RhVac Residential & Light Commercial HVAC Loads ¢
Smith Heating & A/G_
Elite Software Development, Inc.
Cooper6
_►
Duct Size Preview
cont'd)
Room or
Source
Minimum
Maximum
Rough.
Design
SP
Duct
Duct
Htg
Clg
Act.
Duct
Duct Name
Velocity
Velocity
Factor
L/100
Lass
Velocity
Length
Flow
Flow
Flow
Size
RR-140
TMDD 0 0 0.01 0.08
0.00957 507.9
12 277 ;; 277,
1 277
10
Summary
System 1
Heating Flow:
274
Design Friction Rate:
0.08
TEL Return:
81.5
Cooling Flow:
1249
Total Cumulative SP Loss:
0.48
TEL Supply:
156.2
Fan ESP:
0.48
Device SP Loss:
0.29
TEL Total:
237.7
Fan SP Available:
0.19
Return Loss Added to Supply:
0.065
System 2
Heating Flow:
286
Design Friction Rate:
0.081
TEL Return:
41
Cooling Flow:
1109
Total Cumulative SP Loss:
0.136
TEL Supply:
125.6
Fan ESP:
0.136
Device SP Loss:
0
TEL Total:
166.6
Fan SP Available:
0.136
Return Loss Added to Supply: 0.035
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhvac Residential-& Light Commercial HVAC Loads Ehte Software Development, Inc.
Smith Heating & A/C ,. Cooper
Vero Beach, -FL 32960 Page 7
Tabular Manual D Ductsize Grid - System 1
-'Ducts
Room
Zones
Flow
Diam
Wid
Hei
Vel
System 1 -System 1
_
0 Ej>Suppiy
8 F& ST-100
0 Q� ST-110
1
1
1249
.......
654
17.6
13.8
13.6
10.7
19.3
- -
15.1
738
----
627
�jSR-100
Dining Room
1
182
8.6
6.7
9.4
453
,SR-110
Dining Room
1
182
8.6
6.7
9.4
453
El Q� ST-140
1
290
10.2
7.9
11.2
510
--*SR-120
Kitchen
1
145
7.9
6.1
8.6
427
SR-130
0 � ST-120
Kitchen
1
1
145
198
7.9
8.9
6.1
6.9
8.6
9.7
427
463
- -- S SR-140
Foyer -
1
99 -
6.8
5.3
7.5
388
S SR-150
Foyer
1
99
6.8
5.3
7.5
388
El � ST-130
1�
397
11.5
8.9
12.5
553
SR-160
Family Room
1
146
7.9
6.1
8.6428
_ Y '*SR-170
Family Room
1
146�
7.9wW
6.1
8.6
428
El � ST-150
- ---
SR-180
--.._._........................................................................................
Guest Bedroom
1
1
105
89
7
_........ ..............
6.6
5.4 17.6
........__.............._._.
5.1
7.2
393
377
-_-- SR-190
Guest Closet
1
12
3.2
2.4
3.4
1222
SSR-200
Guest Bath
1
4
2.1
1.7
2.3
164
�_ i'� Return_
El RT-100
1249
16.6
12.9
18.1
831
RR-100
1249
116.6
112.9
18.1
831
C-] System3 -System 3
tem --------.__.._._.
(- - --;Return
--.....--._._.._.__...._.._
................................__..._...................._._.._._._..--...
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhv'ac Residential & Light Commercial HVAC Loads t Elite Software Development, Inc.
Smith Heating & A/C -
Cooper_
�
-Pa e 8
Tabular Manual D Ductsize Grid - System 2
Ducts
Room
FeedsFlow
Zones
Diam
Wid
Hei
Vel
System 2 - System 2
El Supply
El � ST-160
_...,-._.-.-.. _ -------------
S Q� ST-170
--...... _...... .......__............ ........---
1,2 ..... _.........
1,2
1102
......... ............. .
1558
16.8
--- --
13
. 13
110.1
18.4
114.2
714
602
SR-210
Master Hall/Closet
2
18
3.7
2.9
4
247
SR-220
_ .._..... _...-_.._...... --....._._..-...__... - --- -
B Z� ST-180
Master Bath
--- ....... ......
1
.... _._.....-
1
84
484
6.4
12.4
5
9.6
7
13.5
371
581
SR-230
Master Bedroom
1
242
9.5
7.4
10.4
487
SSR-240
Master Bedroom
1
242
9.5
7.4
10.4
487
l] � ST-190
2
551
13-
10.1
14.2
600
SR-250 _
East Bedroom 3m
2 .__--
217
9.2
7.2
10
14741
B ST-200
2
321
10.6
8.2
11.6
524
B ST-210
SR-280
SR-290
R ST-220
jEast Bedroom 2
!East Bedroom 2
2
2
2
2
228
114
114
93
9.3
7.2
7.2
6.7
7.2
5.6
5.6
5.2
10.2
7.9
7.9
7.3
480
401
401
381
SSR-300
West Bedroom
2
66
5.9
4.6
6.4
348
SR-310
West Closet
2
2
1.6 -1.3
1.8
135
_ SR-320
West Bath
2
25
4.1
3.2
4.5
270
l] Qj ST-230
2
13
3.2-
2.5
3.5
226
_ SR-260
Bedroom 3 Closet
2
5
2.3
1.8
2.5
174
SR-270
Bed room 3 Bath
2
8
2.7
2.1
3
198
- El !Return
E3 FART-11C
1108
16.9
13.1
18.4
715
RR-1 10
�-
277
10
7.8
11
504
RT-120
831
13
10.1
14.2
902
RR-120
j
277 .10
7.8
10.9
508
y S RR-130
277
10
7.8
10.9
508
S RR-140
277
10
7.8
10.9
508
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Smith Heating & A/C _ Cooper
W_Pa e 9
Tabular Manual D Ductsize Data - Duct System.
I - Supply
---Duct,Name, etc. .. .,
Type _ Roughness
�1
i
Diameter �aVelocity••
SPL.Duct
;Upstream" ,Temperature
Width
i.
Loss/100 SPL.Fit
Shape Length
Height
Fit. Eq. Len SPL.Tot
Sizing `CFM,
Area
SP.Avail SPL.Cumul
---Duct Name: ST-100, Fitting: 1-A, Effective Length: 39.5
Trunk 0.01
17.6
738
0.013
Up: Fan 60
13.6
0.080
0.019
Rnd 16.0
19.3
23.5
0.322
Exact 1,249
73.8
0.093
0.387
---Duct Name: ST-110, Fitting: 11-A, Effective Length: 44.7
Trunk 0.01
13.8
627
0.001
Up: ST-100 60
10.7
0.080
0.035
Rnd 1.0
15.1
43.7
0.036
Exact 654
3.6
0.058
0.423
---Duct Name: ST-120, Fitting: 11-A, Effective Length: 50.7
Trunk 0.01
8.9
463
0.020
Up: ST-100 60
6.9
0.080
0.021
Rnd 25.0
9.7
25.7
0.041
Exact 198
58
0.053
0.427
---Duct Name: ST-130, Fitting: 11-A, Effective Length: 48.9
Trunk 0.01
11.5
553
.0.012
Up: ST-100 60
8.9
0.080
0.027
Rnd 15.0
12.5
33.9
0.039
Exact 397
45.1
0.054
0.426
---Duct Name: SR-100, Supplies: Dining Room, Fitting: 11-A, Effective Length: 32.6
Runout 0.01
8.6
453
0.006
Up: ST-110 60
6.7
0.080
0.020
Rnd 8.0
9.4
24.6
0.026
Exact 182
18
0.032
0.449
---Duct Name: SR-110, Supplies: Dining Room, Fitting: 11-A, Effective Length: 32.6
Runout 0.01
8.6
453
0.006
Up: ST-110 60
6.7
0.080
0.020
Rnd 8.0
9.4
24.6
0.026
Exact 182
18
0.032
0.449
---Duct Name: ST-140, Fitting: 11-A, Effective Length: 41.2
Trunk 0.01
10.2
510
0.008
Up: ST-110 60
7.9
0.080
0.025
Rnd 10.0
11.2
31.2
0.033
Exact 290
.26.7
0.025
0.456
---Duct Name: SR-120, Supplies: Kitchen, Fitting: 11-A, Effective
Length: 30.8
Runout 0.01
7.9
427
0.006
Up: ST-140 60
6.1
0.080
0.018
Rnd 8.0
8.6
22.8
0.025
Exact 145
16.5
0.000
0.480
---Duct Name: SR-130, Supplies: Kitchen, Fitting: 11-A, Effective
Length: 30.8
Runout 0.01
7.9
427
0.006
Up: ST-140 60
6.1
0.080
0.018
Rnd 8.0
8.6
22.8
0.025
Exact 145
16.5
0.000
0.480
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhvac - Residential & Light Commercial HVAC Loads
Smith Heating & A/C
Elite Software Development, Inc.
cooper.
_ _
Vero i-each, FL 32960 _ _. , _.-..,.
_. _. W_
._._
Tabular Manual D Ductsize Data - Duct System 1 - Supply
cont`d)
Duct Name, etc
I`
SPL.Ducf
9 Diameter;
Velocity
p Width
Uystream .,' F - Temuerature�
p
d
Loss/100
SPL.Fit
Shape 'Length Height
;
io"
�Fit.Eq.Len
SPL.Tot
Sizih CFM ., Area
€.
SP.Avail SPL'Cumul
---Duct Name: SR-140, Supplies: Foyer, Fitting: 11-A, Effective Length: 28.7
Runout 0.01 6.8
388
0.008
Up: ST-120 60 5.3
0.080
0.015
Rnd 10.0 7.5
18.7
0.023
Exact 99 17.9
0.030
0.450
---Duct Name: SR-150, Supplies: Foyer, Effective Length: 10.0
Runout 0.01 6.8
388
0.008
Up: ST-120 60 5.3
0.080
0.000
Rnd 10.0 7.5
0.0
0.008
Exact 99 17.9
0.045
0.435
---Duct Name: SR-160, Supplies: Family Room, Effective Length: 8.0
Runout 0.01 7.9
428
0.006
Up: ST-130 60 6.1
0.080
0.000
Rnd 8.0 8.6
0.0
0.006
Exact 146 16.6
0.048
0,432
---Duct Name: SR-170, Supplies: Family Room, Effective Length: 8.0
Runout 0.01 7.9
428
0.006
Up: ST-130 60 6.1
0.080
0.000
Rnd 8.0 8.6
0.0
0.006
Exact 146 16.6
0.048
0.432
---Duct Name: ST-150, Fitting: 11-A, Effective Length: 31.3
Trunk 0.01 7
393
0.010
Up: ST-130 60 5.4
0.080
0.015
Rnd 12.0 7.6
19.3
0.025
Exact 105 22
0.029
0.451
---Duct Name: SR-180, Supplies: Guest Bedroom, Effective Length: 10.0
Runout 0.01 6.6
377
0.008
Up: ST-150 60 5.1
0.080
0.000
Rnd 10.0 7.2
0.0
0.008
Exact 89 17.2
0.021
0.459
---Duct Name: SR-190, Supplies: Guest Closet, Effective Length: 8.0
Runout 0.01 3.2
222
0.006
Up: ST-150 60 2.4
0.080
0.000
Rnd 8.0 3.4
0.0
0.006
Exact 12 6.6
0.023
0.457
---Duct Name: SR-200, Supplies: Guest Bath, Effective Length: 8.0
Runout 0.01 2.1
164
0.006
Up: ST-150 60 1.7
0.080
0.000
Rnd 8.0 2.3
0.0
0.006
Exact 4 4.4
0.023
0.457
Report Units: Pressure: in.wg, Duct lengths: feet, Duct sizes: inch, Airflow: CFM, Velocity: ft./min, Temperature: F
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhv'ac Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
_Smith Heating & A/C_.
Tabular Manual D Ductsize Data - Duct System 1 - Supply (cont'd)
---Duct Name; etc •'
°� .
Type Roughness
Diameter `' Velocity SPL.Duct
Upstream. Temperature
Width la Loss/100 SPL.Fit.
Shape Length
Heightµ Fit.Eq:Len 'SPL.Tot
Sizin CFM.�
Areai�a�' SP,Avail , ; SPL.Cumul
Notes: Static pressure available values for return ducts are at the entrance of the duct. For supply, they are at the exit.
The cumulative static pressure loss value for a return trunk is with respect to the entry point of the return runout upstream
with the highest static pressure available. Total and cumulative
static pressure loss values for the supply main trunk
include any device pressure losses entered, and the cumulative
may also include the total static pressure loss of the return
side.
Surnrhary.,..
.
Number of active trunks:
6
Number of active runouts:
11
Total runout outlet airflow:
1,249
Main trunk airflow:
1,249
Largest trunk diameter:
17.6 ST-100
Largest runout diameter:
8.6 SR-100
Smallest trunk diameter:
7 ST-150
Smallest runout diameter:
2.1 SR-200
Supply fan external static pressure:
0.480
Supply fan device pressure losses:
0.290
Supply fan static pressure available:
0.190
Runout maximum cumulative static pressure loss:
0.480 SR-120
Return loss added to supply:
0.065
Total effective length of return ( ft.):
81.5 RR-100
Total effective length of supply ( ft.):
156.2 SR-120
Overall total effective length ( ft.):
237.7 RR-100 to SR-120
Design overall friction rate per 100 ft.:
0.080 (Available SP x 100 / TEL)
System duct surface area (Scenario 1):
395.4 (Linked to duct load)
Total system duct surface area:
395.4
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhvac Residential & Light Commercial HVAC Loads
Smith Heating &A/C
Elite Software Development, Inc.
Vero Beach, FL 32960
-
Pa a 12
Tabular Manual D Ductsize Data - Duct System 2 - Supply
-Duct Name; etc.
Type Roughness
Diameter,
Velocity
SPL.Duct
:Upstream Temperature
= ° Width a "'
Loss/100
SPL.Fit'
o°
Shape >;„ �E Length
;Height �'
Fit.Eq,Len
SPL.Tot
Sizin .� CFM�:,
.,- Area:,-`.SP.Avail,
$PL:Cumul
---Duct Name: ST-160, Supplies Zones: 1, 2 (3% Diversity), Effective Length: 4.0
Trunk 0.01
16.8
715
0.003
Up: Fan 60
13
0.080
0.000
Rnd 4.0
18.4
0.0
0.003
Exact 1,102
17.6
0.097
0.038
---Duct Name: ST-170, Supplies Zones: 1, 2 (5% Diversity),
Effective Length: 50.0
Trunk 0.01
13
602
0.040
Up: ST-160 60
10.1
0.080
0.000
Rnd 50.0
14.2
0.0
0.040
Exact 558
170.6
0.057
0.078
---Duct Name: STA80, Supplies Zone: 1, Effective
Length: 10.0
Trunk 0.01
12.4
581
0.008
Up: ST-170 60
9.6
0.080
0.000
Rnd 10.0
13.5
0.0
0.008
Exact 484
32.4
0.049
0.086
---Duct Name: SR-210, Supplies: Master Hall/Closet (in Zone 2), Effective Length: 10.0
Runout 0.01
3.7
247
0.008
Up: ST-170 60
2.9
0.080
0.000
Rnd 10.0
4
0.0
0.008
Exact 18
9.6
0.049
0.087
---Duct Name: SR-220, Supplies: Master Bath (in Zone 1), Effective Length: 8.0
Runout 0.01
6.4
371
0.006
Up: ST-170 60
5
0.080
0.000
Rnd 8.0
7
0.0
0.006
Exact 84
13.5
0.051
0.085
---Duct Name: SR-230, Supplies: Master Bedroom
(in Zone 1), Effective Length:
8.0
Runout 0.01
9.5
487
0.006
Up: ST-180 60
7.4
0.080
0.000
Rnd 8.0
10.4
0.0
0.006
Exact 242
20
0.043
0.093
---Duct Name: SR-240, Supplies: Master Bedroom
(in Zone 1), Effective Length:
8.0
Runout 0.01
9.5
487
0.006
Up: ST-180 60
7.4
0.080
0.000
Rnd 8.0
10.4
0.0
0.006
Exact 242
20
0.043
0.093
---Duct Name: ST-190, Supplies Zone: 2, Fitting: 1-A, Effective Length: 25.6
Trunk 0.01
13
600
0.008
Up: ST-160 60
10.1
0.080
0.012
Rnd 10.0
14.2
15.6
0.020
Exact 551
34
0.077
0.059
---Duct Name: ST-200, Supplies Zone: 2, Fitting: 11-A, Effective Length: 42.9
Trunk 0.01
10.6
524
0.008
Up: ST-190 60
8.2
0.080
0.026
Rnd 10.0
11.6
32.9
0.034
Exact 321
27.8
0.042
0.093
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Smith Heating & A/C__,
Page 13
Tabular Manual D Ductsize Data - Duct System
2 - Supply
cont'd) .
.- Duct,Name, etc.':,
Type
Roughness,,,, - .
Diameter,
, Velocity - SPL.Duct
Upstream "
Temperature ,.
,Width ii
Loss/100 SPL.Fit
,
Shape ---'.
Length'
_
Height;3
Fit.Eq.Len SPL.Tot
Sizing ,•
CFM ,~,,�` ,. ' _
,, mArea ��
SP.Avail ° SPL.Cumul,
---Duct Name: ST-210, Supplies Zone: 2, Fitting: 11-A, Effective Length: 37.6
Trunk 0.01 9.3
480
0.008
Up: ST-200 60 7.2
0.080
0.022
Rnd 10.0 10.2
27.6
0.030
Exact 228 24.4
0.012
0.123
---Duct Name: ST-220, Supplies Zone: 2, Fitting: 11-A, Effective Length: 43.1
Trunk 0.01 6.7
381
0.020
Up: ST-200 60 5.2
0.080
0.015
Rnd 25.0 7.3
18.1
0.034
Exact 93 43.8
0.008
0.128
---Duct Name: SR-250, Supplies: East Bedroom 3 (in Zone 2), Effective Length: 8.0
Runout 0.01 9.2
474
0.006
Up: ST-190 60 7.2
0.080
0.000
Rnd 8.0 10
0.0
0.006
Exact 217 19.2
0.070
0.065
---Duct Name: ST-230, Supplies Zone: 2, Fitting: 11-A, Effective Length: 21.4
Trunk 0.01 3.2
227
0.012
Up: ST-190 60 2.5
0.080
0.005
Rnd 15.0 3.5
6.4
0.017
Exact 13 12.7
0.060
0.076
---Duct Name: SR-260, Supplies: Bedroom 3 Closet (in Zone 2), Effective Length: 6.0
Runout 0.01 2.3
175
0.005
Up: ST-230 60 1.8
0.080
0.000
Rnd 6.0 2.5
0.0
0.005
Exact 5 3.6
0.055
0.081
---Duct Name: SR-270, Supplies: Bedroom 3 Bath (in Zone.2), Effective Length: 6.0
Runout 0.01 2.7
198
0.005
Up: ST-230 60 2.1
0.080
0.000
Rnd 6.0 3
0.0
0.005
Exact 8 4.3
0.055
0.081
---Duct Name: SR-280, Supplies: East Bedroom 2 (in Zone 2), Effective Length: 8.0
Runout 0.01 7.2
401
0.006
Up: ST-210 60 5.6
0.080
0.000
Rnd 8.0 7.9
0.0
0.006
Exact 114 15.1
0.006
0.130
---Duct Name: SR-290, Supplies: East Bedroom 2 (in Zone 2), Effective Length: 8.0
Runout 0.01 7.2
401
0.006
Up: ST-210 60 5.6
0.080
0.000
Rnd 8.0 7.9
0.0
0.006
Exact 114 15.1
0.006
0.130
---Duct Name: SR-300, Supplies: West Bedroom (in Zone 2), Effective Length: 6.0
Runout 0.01 5.9
349
0.005
Up: ST-220 60 4.6
0.080
0.000
Rnd 6.0 6.4
0.0
0.005
Exact 66 9.3
0.003
0.133
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Smith Heating & A/C Cooper.
_ _ _ _. _. _ ._w,.
Vero Beach, FL 32960
_- m.
_. ._ ... _.- _ _ _ -, Pa e:14
Tabular Manual D Ductsize Data - Duct System 2 - Supply cont'd)
Type Roughness
Diamueter j `°, Velocity SPL.Duct
Upstream,- , Temperature
Width �j Loss/100 SPL.Fit,
Shape Lengfh.`.
` Height, ' °. F.it.Eq.Len SPL.Tot`
Sizing CFM '
�.�Area i, SP.Avail SPL.Curnul
---Duct Name: SR-310, Supplies: West Closet (in Zone 2), Effective Length: 6.0
Runout 0.01
1.6 135 0.005
Up: ST-220 60
1.3 0.080 0.000
Rnd 6.0
1.8 0.0 0.005
Exact 2
2.6 0.003 0.133
---Duct Name: SR-320, Supplies: West Bath (in Zone
2), Effective Length: 10.0
Runout 0.01
4.1 270 0.008
Up: ST-220 60
3.2 0.080 0.000
Rnd 10.0
4.5 0.0 0.008
Exact 25
10.8 0.000 0.136
Report Units: Pressure: in.wg, Duct lengths: feet, Duct sizes: inch, Airflow: CFM, Velocity: ft./min, Temperature: F
Notes: Static pressure available values for return ducts are
at the entrance of the duct. For supply, they are at the exit.
The cumulative static pressure loss value for a return trunk
is with respect to the entry point of the return runout upstream
with the highest static pressure available. Total and cumulative static pressure loss values for the supply main trunk
include any device pressure losses entered, and the cumulative may also include the total static pressure loss of the return
side.
Summary
Number of active trunks:
8
Number of active runouts:
12
Total runout outlet airflow:
1,137
Main trunk airflow:
1,102
Largest trunk diameter:
16.8 ST-160
Largest runout diameter:
9.5 SR-230
Smallest trunk diameter:
3.2 ST-230
Smallest runout diameter:
1.6 SR-310
Supply fan external static pressure:
0.136
Supply fan device pressure losses:
0.000
Supply fan static pressure available:
0.136
Runout maximum cumulative static pressure loss:
0,136 SR-320
Return loss added to supply:
0.035
Total effective length of return ( ft.):
41.0 RR-130
Total effective length of supply ( ft.):
125.6 SR-320
Overall total effective length ( ft.):
166.6 RR-130 to SR-320
Design overall friction rate per 100 ft.:
0.081 (Available SP x 100 / TEL)
System duct surface area (Scenario 1):
506.2 (Not linked to duct load)
Total system duct surface area:
506.2
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhvac Residential. & Light Commercial HVAC Loads
Heating & A/C
Elite Software. Development, Inc.
!Smith
Vero Beacb,.FL 32960 °�
Pa a 15
Tabular Manual D Ductsize Data - Duct System 9 - Return
- Duct Name, etc.'';_
_
Type, Roughness_ Dla'meter"
Velocity,,,SPL:Duct
'Upstream.-.,. - Terperature--. : 'Width,V
Loss/100 SPL.Fit
Shape �- Length ;,i > ' , Height 11
`Fit.Eq.Len SPL.Tot
Sizin CFM Area li
SP.Avail SPL.Cumul
---Duct Name: RT-100, Fittings: 6-F, 5-K, Effective Length: 59.3
Trunk 0.003 16.6
831 0.008
Up: Fan 60 12.9
0.080 0.040
Rnd 10.0 18.1
49.3 0.048
Exact 1,249 43.4
-0.018 0.065
---Duct Name: RR-100, Fitting: 6-H, Effective Length: 22.1
Runout 0.003 16.6
831 0.001
Up: RT-100 60 12.9
0.080 0.017
Rnd 1.0 18.1
21.1 0.018
Exact 1,249 4.3
0.000 0.018
Report Units: Pressure: in.wg, Duct lengths: feet, Duct sizes: inch, Airflow: CFM, Velocity: ft./min, Temperature: F
Notes: Static pressure available values for return ducts are at the entrance of the duct.
For supply, they are at the exit.
The cumulative static pressure loss value for a return trunk is with respect to the entry point of the return runout upstream
with the highest static pressure available. Total and cumulative static pressure loss values for the supply main trunk
include any device pressure losses entered, and the cumulative may also include the total static pressure loss of the return
side.
Summa
Number of active trunks: 1
Number of active runouts: 1
Total runout outlet airflow: 1,249
Main trunk airflow: 1,249
Largest trunk diameter: 16.6 RT-100
Largest runout diameter: 16.6 RRA 00
Smallest trunk diameter: 16.6 RT-100
Smallest runout diameter: 16.6 RRA 00
Runout maximum cumulative static pressure loss: 0.018 RR-1 00
Return loss added to supply: 0.065
Total effective length of return ( ft.): 81.5 RR-1 00
System duct surface area (Scenario 1): 47.8
(Linked to duct load)
Total system duct surface area: 47.8
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhvac Residential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Smith Heating & A/C_ . __.
_M
_- =
Cooper.
Vero Beach, nFL .32960 - -.. _ o.� _�__ _ ___._ .
".._. _. _. _ _. _ ..
_��-__ . . _ _._. _ t:. -
- - Pa a 16
Tabular Manual D Ductsize Data - Duct System
2 - Return
--Duct.Name, etc.
.Type° Roughness
Diameter?
Velocity
SPL.Duct
Upstream,,- Temperature',
"1Nidth;'
Loss/100
SPL.Fit
Shape . _ , Length`.:
"�'Height 1i..
Fit. Eq. Len. ; :
SPL:Tot'
Sizin `a r°. °,:= CFM `",,: °
�� °;Area!!
S P.Avail SPL.Cumul
---Duct Name: RT-110, Effective Length: 4.0
Trunk 0.01
16.9
715
0.003
Up: Fan 60
13.1
0.080
0.000
Rnd 4.0
18.4
0.0
0.003
Exact 1,108
17.6
-0.032
0.035
---Duct Name: RR-110, Effective Length: 16.0
Runout 0.01
10
504
0.012
Up: RT-110 60
7.8
0.080
0.000
Rnd 15.0
11
0.0
0.012
Exact 277
39.4
-0.020
0.012
---Duct Name: RT-120, Effective Length: 25.0
Trunk 0.0003
13
902
0.023
Up: RT-110 72
10.1
0.090
0.000
Rnd 25.0
14.2
0.0
0.023
Nearest Inch 831
85.1
-0.010
0.013
---Duct Name: RR-120, Effective Length: 6.0
Runout 0.01
10
508
0.005
Up: RT-120 72
7.8
0.080
0.000
Rnd 6.0
10.9
0.0
0.005
Nearest Inch 277
15.7
-0.005
0.005
---Duct Name: RR-130, Effective Length: 12.0
Runout 0.01
10
508
0.010
Up: RT-120 72
7.8
0.080
0.000
Rnd 12.0
10.9
0.0
0.010
Nearest Inch 277
31.4
0.000
0.010
---Duct Name: RR-140, Effective Length: 12.0
Runout 0.01
10
508
0.010
Up: RT-120 72
7.8
0.080
0.000
Rnd 12.0
10.9
0.0
0.010
Nearest Inch 277
31.4
0.000
0.010
Report Units: Pressure: in.wg, Duct lengths: feet, Duct sizes:
inch, Airflow: CFM, Velocity: ft./min, Temperature: F
Notes: Static pressure available values for return ducts are at the entrance of the duct.
For supply, they are at the exit.
The cumulative static pressure loss value for a return trunk is
with respect to the entry point
of the return runout upstream
with the highest static pressure available. Total and cumulative
static pressure loss values for the supply main trunk
include any device pressure losses entered, and the cumulative
may also include the total static pressure loss of the return
side.
Sumrna
Number of active trunks:
2
Number of active runouts:
4
Total runout outlet airflow:
1,108
Main trunk airflow:
1,108
Largest trunk diameter:
16.9 RT-110
Largest runout diameter:
10 RR-1 10
Smallest trunk diameter:
13 RT-120
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
ii;ro
hvac Residential &Light Commercial HVAC Loads Elite Software Development, Inc.
rCoopBeach, FL �32960 ��.__
--_- "Pae17
Tabular Manual D Ductsize Data - Duct System 2 - Return (cont'd
Summary.,
Smallest runout diameter: 10y RRA20
Runout maximum cumulative static pressure loss: 0.010 RRA30
Return loss added to supply: 0.035
Total effective length of return ( ft.): 41.0 RRA30
System duct surface area (Scenario 1): 220.7 (Not linked to duct load)
Total system duct surface area: 220.7
Notes��,
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Smith Heating & A/C_ _ Cooper
Beach,`FL 3296 ------
_ _ _ .._ ._ .... .... _ ,.: _._.... - Pa a 18
Tabular Manual D Ductsize - Pressure Changes Graph - S stem 1
Pressure Changes Through Route with Highest Static Pressure Loss
0.16
0.14
D
0.12
0.10 E
0.08
3 0.06 F
C
•- w
G
0.02
a
A
0.00
H
-0.02 B
-0.04
-0.06
-0.08
—+— Static Pressure Available
— ♦— Velocity Pressure
—o— Total Pressure Available
Notes: Return side point values are at entrance of duct, while supply side points are at exit. When a return system is
present, an additional return side point named [Fan Entrance] is drawn in the graph to show the static pressure available at
the entrance of the fan. When a supply system is present, and an additional supply side point named [Fan Exit] is drawn
to show the static pressure available at the exit of the fan. Any device pressure losses entered for the supply main trunk
are accounted for between the fan entry and exit points.
PointName °? "•Static,,PressureAvailable •"" TotaloPressureAvailable
A RR-100 0.000 0.044
B RT-100-0.018. 0.026
C [Fan Entrance] -0.065 -0.021
D [Fan Exit] 0.125 0.160
E ST-100 0.093 0.128
F ST-110 0.058 0.083
G ST-140 0.025 0.041
H SR-120 0.000 0.012
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Smith Heating & A/C . _ Cooperil
,Vero Beach, FL,' 32960 _
Tabular Manual D Ductsize - Pressure Changes Graph - System 2
Pressure Changes Through Route with Highest Static Pressure Loss
0.16
0.14
0.12
0.10 E
m 0.08 G
3
c
0.06
0
m H
a` 0.04 /
0.02
0.00
J
-0.02
-0.04 A B D
—•— Static Pressure Available
—O— Velocity Pressure
—�— Total Pressure Available
Point.
mg.o -E
Notes: Return side point values are at entrance of duct, while supply side points are at exit. When a return system is
present, an additional return side point named [Fan Entrance] is drawn in the graph to show the static pressure available at
the entrance of the fan. When a supply system is present, and an additional supply side point named [Fan Exit] is drawn
to show the static pressure available at the exit of the fan. Any device pressure losses entered for the supply main trunk
are accounted for between the fan entry and exit points.
Pointe, h,Name' {. Static :Pressure Available Total Pressure'Available
A RR-130 0.000 0.016
B RT-120 -0.010 0.041
C RT-110 -0.032 0.000
D [Fan Entrance] -0.035 -0.003
E [Fan Exit] 0.100 0.133
F ST-160 0.097 0.130
G ST-190 0.077 0.100
H ST-200 0.042 0.060
1 ST-220 0.008 0.017
J SR-320 0.000 0.005
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhvac Residential &Light Commercial HVAC Loads
Elite Software
Development,
Inc.
Smith Heating & A/G
-_
Cooper:
-_ _ _.:
. _ _ _ , _ .. w ¢
Vero Beach,VFL 32960
_
_.- _.._ r
y,, -
Pa a 20
Total Building Summary Loads
Component
Area
"Sen ii
,,,, :Lat
tiu. S e n
.Total
Descri tion.L .
Quan,i
Lo s �,
Gain „
Gain
Gain,
A3A-Loebr: Glazing -Single -hung, vinyl, Impact, no break,
138
4,132
0
4,788
4,788
outdoor insect screen with 50% coverage, u-value
1.07, SHGC 0.37
A1A-cm-x: Glazing -Fixed Window, 2P, Argon, Vinyl,
87
2,605
0
2,669
2,669
Impact, no break, u-value 1.07, SHGC 0.37
A4-cm-o: Glazing -Sliding glass door, 2P, aluminum, no
544
16,302
0
21,946
21,946
break, u-value 1.07, SHGC 0.37
A1A-SGD: Glazing -Sliding Glass Window, vinyl, Impact,
60
1,798
0
1,430
1,430
no break, u-value 1.07, SHGC 0.37
11 D: Door -Wood - Solid Core
30
328
0
304
304
B12B-1311stucco: Wall -Frame, Custom, 2x4 framed
1829
4,967
0
4,276
4,276
wall/R11 batts with Stucco exterior
1861-8-19o: Roof/Ceiling-Roof Joists Between Roof
3333
4,851
0
3,640
3,640
Deck and Ceiling or Foam Encapsulated Roof Joists,
Spray Foam Insulation, White or Light Color Asphalt
Shingle, Any Wood Shake, Dark or Medium Color
Tile, Slate or Concrete, Light or Unpainted Metal,
Light or Silver Membrane, Light Tar and Gravel, R-19
open cell 1/2 lb. spray foam, 5 inches in 2 x 8 joist
cavity
19A-Ocp: Floor -Over enclosed crawl space, No insulation
2019
6,263
0
3,357
3,357
on exposed walls, sealed or vented space, passive,
no floor insulation, carpet or hardwood
Subtotals for structure:
41,246
0
42,410
42,410
People:
6
1,200
1,380
2,580
Equipment:
722
3,305
4,027
Lighting:
0
0
0
Ductwork:
0
0
4,185
4,185
Infiltration: Winter CFM: 61, Summer CFM: 61
1,874
2,527
1,003
3,530
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
- - - ---- ..... ..... - ..... -- -- -----
Total Building Load Totals:
-- --
--- -
43,120
-- -_
4,449
-
52,283
- -- --
56,732
Check Figures .
Total Building Supply CFM: 2,358
CFM Per Square ft.:
0.708
Square ft. of Room Area: 3,333
Square ft. Per Ton:
574
Volume (ft'): 36,510
BuildingLoads' "
Total Heating Required Including Ventilation Air: 43,120
Btuh
43.120
MBH
Total Sensible Gain: 52,283
Btuh
92
%
Total Latent Gain: 4,449
Btuh
8
%
Total Cooling Required Including Ventilation Air: 56,732
Btuh
4.73
Tons (Based On Sensible +
Latent)
5.81
Tons (Based On 75% Sensible
Capacity)
Notes,
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version
2, and
ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads
according
to the manufacturer's performance data at
your design conditions.
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhvec Residential& Light' Commercial HVAC Loads
Smith Heating & A/C
Elite Software Development,
Inc
Cooper
Vero:Beach, FL 329fi0 w 4'' '"
li ''
r aT
Pa` a°21,
System 9 S stem 1 Summary Loads
<'}
Area Sen j}
Lat
Seri`;i
Totah.
IComponent
,Deicription' u "Quan
°,
Loss fl
Gain;.
Gain ]
Gain
A3A-Loebr: Glazing -Single -hung, vinyl, Impact, no break,
68
2,036
0
2,126
2,126
outdoor insect screen with 50% coverage, u-value
1.07, SHGC 0.37
A1A-cm-x: Glazing -Fixed Window, 2P, Argon, Vinyl,
42
1,258
0
1,595
1,595
Impact, no break, u-value 1.07, SHGC 0.37
A4-cm-o: Glazing -Sliding glass door, 2P, aluminum, no
288
8,630
0
9,314
9,314
break, u-value 1.07, SHGC 0.37
A1A-SGD: Glazing -Sliding Glass Window, vinyl, Impact,
60
1,798
0
1,430
1,430
no break, u-value 1.07, SHGC 0.37
11 D: Door -Wood - Solid Core
30
328
0
304
304
B1 2B-R1 1 stucco: Wali-Frame, Custom, 2x4 framed
1030
2,796
0
2,409
2,409
wall/R11 batts with Stucco exterior
18B1-8-19o: Roof/Ceiling-Roof Joists Between Roof
1581
2,302
0
1,726
1,726
Deck and Ceiling or Foam Encapsulated Roof Joists,
Spray Foam Insulation, White or Light Color Asphalt
Shingle, Any Wood Shake, Dark or Medium Color
Tile, Slate or Concrete, Light or Unpainted Metal,
Light or Silver Membrane, Light Tar and Gravel, R-19
open cell 1/2 lb. spray foam, 5 inches in 2 x 8 joist
cavity
19A-Ocp: Floor -Over enclosed crawl space, No insulation
315
977
0
524
524
on exposed walls, sealed or vented space, passive,
no floor insulation, carpet or hardwood
Subtotals for structure:
20,125
0
19,428
19,428
People:
2
400
460
860
Equipment:
722
3,305
4,027
Lighting:
0
0
0
Ductwork:
0
0
4,185
4,185
Infiltration: Winter CFM: 32, Summer CFM: 32
975
1,315
521
1,836
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
System 1 System 1 Load Totals:
21,100
2,437
27,899
30,336
"Check F ig ures
Supply CFM: 1,249
CFM Per Square ft.:
0.790
Square ft. of Room Area: 1,581
Square ft.
Per Ton:
510
Volume (ft'): 18,990
System, Loads
Total Heating Required Including Ventilation Air: 21,100
Btuh
21.100
MBH
Total Sensible Gain: 27,899
Btuh
92
%
Total Latent Gain: 2,437
Btuh
8
%
Total Cooling Required Including Ventilation Air: 30,336
Btuh
2.53
Tons (Based On Sensible +
Latent)
3.10
Tons (Based On 75% Sensible
Capacity)
1. Notes"
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version
2, and ACCA Manual
D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads
according to the manufacturer's
performance
data at
your design conditions.
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhvac Residential & Light,Commercial, HVAC Loads
Smith Heating & A/C
Elite Software Development, Inc.
Cooper_
_
'Pa a 22
System 2 System 2 Summaq Loads
Component
Areal '
'Zen,
Lat
Sen ii
Total
Descri tion . ' �I , `
Quan
Loss
Gain '
Gain ii.
Gain,
A1A-cm-x: Glazing -Fixed Window, 2P, Argon, Vinyl,
45
1,347
0
1,074
1,074
Impact, no break, u-value 1.07, SHGC 0.37
A4-cm-o: Glazing -Sliding glass door, 2P, aluminum, no
256
7,672
0
12,632
12,632
break, u-value 1.07, SHGC 0.37
A3A-Loebr: Glazing -Single -hung, vinyl, Impact, no break,
70
2,096
0
2,662
2,662
outdoor insect screen with 50% coverage, u-value
1.07, SHGC 0.37
B12B-R11stucco: Wall -Frame, Custom, 2x4 framed
799
2,171
0
1,867
1,867
wall/R11 batts with Stucco exterior
18B1-8-190: Roof/Ceiling-Roof Joists Between Roof
1752
2,549
0
1,914
1,914
Deck and Ceiling or Foam Encapsulated Roof Joists,
Spray Foam Insulation, White or Light Color Asphalt
Shingle, Any Wood Shake, Dark or Medium Color
Tile, Slate or Concrete, Light or Unpainted Metal,
Light or Silver Membrane, Light Tar and Gravel, R-19
open cell 1/2 lb. spray foam, 5 inches in 2 x 8 joist
cavity
19A-Ocp: Floor -Over enclosed crawl space, No insulation
1704
5,286
0
2,833
2,833
on exposed walls, sealed or vented space, passive,
no floor insulation, carpet or hardwood
Subtotals for structure:
21,121
0
22,982
22,982
People:
4
800
920
1,720
Equipment:
0
0
0
Lighting:
0
0
0
Ductwork:
0
0
0
0
Infiltration: Winter CFM: 29, Summer CFM: 29
899
1,212
482
1,694
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
System 2 System 2 Load Totals:
22,020
2,012
24,384
26,396
Check Figures
Supply CFM: 1,109
CFM Per
Square ft.:
0.633
Square ft. of Room Area: 1,752
Square ft.
Per Ton:
647
Volume (ft'): 17,520
System yLoads .
Total Heating Required Including Ventilation Air: 22,020
Btuh
22.020
MBH
Total Sensible Gain: 24,384
Btuh
92
%
Total Latent Gain: 2,012
Btuh
8
%
Total Cooling Required Including Ventilation Air: 26,396
Btuh
2.20
Tons (Based On
Sensible + Latent)
2.71
Tons (Based On
75% Sensible
Capacity)
Notes ..
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version
2, and
ACCA Manual
D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads
according
to the manufacturer's
performance data at
your design conditions.
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rh%Ac Residential & Light Commercial HVAC Loads
Elite Software Development, triec:
Pa a 23
System 1 Room Load Summary
..,. ���'
° t
Htg; :Min°;.
t :Run'
�a Run'
Clg
' , Clg `
Min,
Act
Room
Area
Sens Htg., ,
Duct
-Duct
Sens
Lat
Clg
Sys
"No Name �.
SFr =_,
Btuh;.. _CFM,
Size
�„ Vel �:
,,;;. Btuh
;;..Btuh „CFM°.:
CFM,
---Zone 1---
1 Foyer
315
4,398 57
7,7
-
4,357
279
198
198
2 Family Room
480
7,060 92
8,8
-
6,428
291
292
292
3 Dining Room
240
5,673 74
9,9
-
8,011
277
364
364
4 Kitchen
252
2,400 31
8,8
-
6,356
1,008
289
289
5 Guest Bedroom
196
1,191 15
7
-
1,955
521
89
89
6 Guest Closet
35
286 4
3
-
262
61
12
12
7 Guest Bath
63
92 1
2
-
80
0
4
4
Return Duct
0
451
0
System 1 total __
1,581
21,100 274
27,899
2,437
1,249
1,249
System 1 Main Trunk Size:
18 in.
Velocity:
738 ft./min
Loss per 100 ft.:
0.080 in.wg
Duct size results above are from Manual D Ductsize.
Runout duct velocities are not printed with
duct size results from Manual D Ductsize since they can vary within
the room.
See the Manual D Ductsize report for duct velocities and other
data.
Cooling System Summary,
Cooling,
, . Sensible/Latent
Sensible '
,
Latent' .
Total
Tons,
. S if:,
_
Btuh
�.°
Btuh
Btuh
Net Required:
2.53
92% / 8%
27,899
2,437
30,336
Recommended:
3.10
75% / 25%
27,899
9,300
37,198
Equi merit Data •.
e•
Heating System
Cooling
System
Type:
Natural Gas Furnace
Standard Air Conditioner
Model:
Indoor Model:
Brand:
Efficiency:
0 AFUE
0 SEER
Sound:
0
0
Capacity:
0 Btuh
0 Btuh
Sensible Capacity:
n/a
0 Btuh
Latent Capacity:
n/a
0 Btuh
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM
Rhvac Residential & Light Commercial HVAC Loads
Smith Heating & A%C_a�j
Elite Software Development, Inc.
Vero Bea6h,.FL-32960
'
24
System 2 Room Load Summaty
'Htg' Min Run'" Run
Clg'`
" a Clg 'Min Act
° ,Room. . „ ° 'Area. ;�
Sens: : _ '• �Htg,` .' , ` Duct - Duct
Sens
Lat Clg, , Sys
• N Name SF,
Btuh'?° CFM,-' ` ° Size ° Vel
Btuh
Btuh . � `,CFM CFM
---Zone 1---
8 Master Bedroom 400
7,930 103 10,10 -
10,620
814 483 483
9Master Bath 196
2,713 35 6 -
1,853
290 84 84
Zone 1 subtotal 596
_
10,643 — 138
12,473
1,104 567 567
---Zone 2---
10 Master Hall/Closet 140
638 8 4 -
386
0 18 18
11 West Bedroom 196
2,198 29 6 -
1,447
145 66 66
12 West Bath 64
816 11 4 -
553
83 25 25
13 West Closet 48
70 1 2 -
52
0 2 2
14 East Bedroom 2 325
3,678 48 7,7 -
5,014
335 228 228
15 Hall 60
273 4 11-4 87
166
0 8 8
16 East Bedroom 3 224
3,253 42 9 -
4,765
345 217 217
17 Bedroom 3 Closet 36
164 2 2 -
99
0 5 5
18 Bedroom 3 Bath 63
287 4 3 -
174
0 8 8
Zone 2 subtotal 1,156
11,377 148
12,656
908 576 576
System 2 total 1,752
22,020 286
24,384
2,012 1,109 1,109
System 2 Main Trunk Size:
17 in.
Velocity:
715 ft./min
Loss per 100 ft.:
0.080 in.wg
Duct size results above are from Manual D Ductsize except where indicated otherwise.
Runout duct velocities are not printed with duct size results from Manual D Ductsize since they
can vary within the room.
See the Manual D Ductsize report for duct velocities and other data.
Indicates duct sized with Rhvac's built-in
duct sizing rather than with Manual D Ductsize.
Note: Since the system is multizone, the
Peak Fenestration Gain Procedure was used to determine glass sensible gains
at the room and zone levels, so the sums
of the zone sensible gains and airflows for
cooling
shown above are not intended
to equal the totals at the system level.
Room and zone sensible gains and cooling CFM values are for the hour in which
the glass sensible gain for the zone is
at its peak. Sensible gains at the system level are based
on the "Average Load
Procedure + Excursion" method.
Conlin 'S stem Summary _ . `
" ' �° " '
Cooling,
-,`,,,Sensible/Latent• Sensible °'
:Latent°` Total
Tons
Slit Btuh'.'
Btuh `°' Btuh
Net Required: 2.20
92% / 8% 24,384
2,012 26,396
Recommended: 2.71
75% / 25% 24,384
8,128 32,512
E ui merit' Data'
w
Heatinq System
Cooling
System
Type:
Natural Gas Furnace
Standard Air Conditioner
Model:
Indoor Model:
Brand:
Efficiency:
0 AFUE
0 SEER
Sound:
0
0
Capacity:
0 Btuh
0 Btuh
Sensible Capacity:
n/a
0 Btuh
Latent Capacity:
n/a
0 Btuh
C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\Cooper.rh9 Tuesday, November 28, 2017, 10:46 AM