Loading...
HomeMy WebLinkAboutREVISION'w t"ILE COP'Y' 6 OFFICE USE ONLY: q DATE FILED: �V _ _ PERMIT # REVISION FEE: A RECEIPT# PLANNING & DEVELOPMENT SERVICES ]BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE. FORT PIERCE, FL 34982-5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIO PROJECT INFORMATION LOCATION/SITE ADDRESS: --7 903- �cr--ryi OyJ L :✓ram--c � � Z--� L] JAN 2 2 2018 Wsie County, Pe rmjtting DETAILED DESCRIPTIOIR OF PROJECT REVISIONS: CA-?ATJ?bL-0 '19(�6N -T-6 2--clzo CONTRACTOR INFOR VIATION: STATE ofFL REGA'ERT. h: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: I� CITY: S'-�li-- k } TATE: f�L PHONE (DAYTIME): ��Z, 2 " — OWNER/BUILDER INFO*TCAATION: NAME: ADDRESS: CITY: PHONE (DAYTIME: ARCHITECT/ENGINFER f '4FORMATION: NAME: ADDRESS: �i S CITY: C "L4-M� STATE: PHONE (DAYTIME): SLCCC: 9123109 Revised 06/.30/17 - I ST. LUCIE CO CERT. #: I ZIP: glgl "y FAX:��j!% FAX: REVISION 1. DESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS: 1. THE 2014 FLORIDA BUILDING CODE, 5TH EDITION SPECIFICALLY - CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CHAPTER 23 WOOD. 2. ASCE 7-10. & SEI7 3. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 4. ACI318 CONCRETE REFRENCE MANUAL. 5. PCI PRECAST & PRESTRESSED CONCRETE. 6. AA ASM 35 & AA ADM 1 WIND LOADS: 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: B 3. SCREENED ROOF ENCLOSURE FBC 2014 CH. 20 TABLE 2002.4 CONCRETE & FOUNDATION DESIGN: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE.: A. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: I. PORTLAND CEMENT TYPE 1 - ASTM C 150 II. AGGREGATES LARGE AGGREGATE 3/4" MAX. - ASTM C 33 III. AIR ENTRAINING +/- 1 % - ASTM C 260 IV. WATER REDUCING AGENT - ASTM C 494 V. CLEAN POTABLE WATER VI. OTHER ADMIXTURES NOT PERMITTED B. METAL ACCESSORIES SHALL,CONFORM TO: I. REINFORCING BARS - ASTM A615, GRADE 60. II. WELDED WIRE FABRIC - ASTM A185 C. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. D. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. E. MOIST CURE OR POLYETHYLENE CURING PERMITTED. F. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE FOR TERMITES IN COMPLIANCE WITH THE FBC. EXCEPTION: AN, INSPECTION IS NOT REQUIRED FOR DRIVEWAY SLABS,PATIO SLABS, WALKS, ETC. WHICH ARE CONSIDERED NON -HABITABLE SPACES G. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. ' ` 2. IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION. 3. WHEN APPLICABLE FOR ATTACHING NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS. 4. WHEN INSTALLING 4" CONCRETE SLAB -ADD ADJACENT TO EXISTING-DOWELL INTO EXISTING CONCRETE 48" O/C W/8" #5 REBARS- DRILL 3/4" HOLE 4" EMBEDMENT- EPDXY W/ NON -SHRINKING "SIMPSON EPDXY TIE" (OR EQUAL). 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHER WISE NOTED. ALUMINUM SPECIFICATIONS: FIL 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLES OTHERWISE SPECIFIED. ; 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED '� RECEIVED #12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. K 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANE JAN 2 2 2018 (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.02pl�INCHES.-v, s . Lucie County, Permitting 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN�'�'; IAIIKTM SPEEDS EXCEED 75 MPH BE PER FBC.' y { 6. 20/20 SC " -Q UNLESS FASTNER SPECIFICATIONS: 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, AND FASTENERS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1/4"X3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1 "X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1/4"X2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14X2-3/4" WOOD SCREW AT 24 O.C. AND 6 FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10X1-1/2" SMS OR TEK SCREW AT 24 O.C. AND 6 FROM ENDS D. WHERE 1'X2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS: 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. MISCELLANEOUS: 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4101.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. RESPONSIBILITIES: 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. o u 6 o a w : Q y° 0 ? 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND INSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. LEGEND: (ALL MAY NOT APPLY SCR = SCREEN KP = KICK PLATE PW = PICTURE WINDOW X = HORIZ. SLIDING WINDOW O = HORIZ. STATIONARY WINDOW DH = DOUBLE HUNG WINDOW SH= SINGLE HUNG WINDOW SIP = SOLID INSULATED PANEL CT = CABLE TIE SG = SUPER GUTTER CS = CLEAR SPAN KB = KNEE BRACE ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2"x2"x0.044" 2 x 3: 2"x3"x0.044" 2 x 4: 2"x4"4.044" 2 x 5: 2"x5"x0.050" OPEN BACK SECTIONS 1 x 2: 1 "x2"4.044" 1 x 3: 1 "x3"0.044" SNAP SECTIONS 2 x 2 SNAP: 2"x2"4.050" 2 x 3 SNAP: 2"x3"x0.050" 2 x 4 SNAP: 2"x4"0.045" SELF MATING (SMB) 2 x 4 SMB: 2"x4"0.044"x0.100" 2 x 5 SMB: 2"x5"x0.050"xq.100" 2 x 6 SMB: 2"x6"x0.050"x0.120" 2 x 7 SMB: 2"x7"x0.0574.120" 2 x 8 SMB: 2"x8"x0.072"x0.124" 2 x 9 SMB: 2"x9"x0.082"x0.124" 2 x 10 SMB: 2"x10"0.092"x0.398" NOTE: AS INDICATED ABOVE ALL MEMBER PROFILES ARE INDICATED IN INCHES. �1 he C.) fir tee05Oto� Cirt-t`c� a- 0 CD �� L-'.! C Lm uj� Cn im Wi t- IM rr� CL CO rc U7rJ. W < L0 CJ cc c� �o zN \f -- 0>_WJ t� In �: a. �5zz>0 rt�is 1 �Q¢V -' � Lr \ (m U. Lu �u \ w wa is p Ir 0 map aW Zm gm M~ O J m M o F- co Zz p 0 -WOO W_0OCm W .J O - Z ~ W C M T7 w Q _j ,4 C1 Q 2 O "t 0 LL 2 Z) Z_ 2 .J Q 2 U w m co Z w w o U) a w w 0 Ix a N 00 I- C) w U U N O C+7 ti d0ESIGN DATE: 11/17/2017 1 REVISION 1: 12/15/2017 PAGE VISION 2: 1/18/2018 SCALE: NTS 8" FOOTER IT HOUSE I O NEW 4" CONCRETE SLAB 3000 PSI W/ FIBERMESH o DOOR; �r PAD � 4'-0" 1X2 0 c%) 2X2 O X X co N X N 2X4 SMB 0 2X2 DJ ! 111XZ zo toli ROOF RISE --------------- ------------- I a � a I � I W I 3 I X CHAJR RAIL ROOF RISE PROFILE 16'-0" CONC. PLAN NTS 4,Iz Grade 8" 3000 PSI FIBERMESH W(1) #5 REBAR CONT. FOOTING PIN NOTE: CONCRETE FOOTING INTERSECTING EXISTING FOOTING DOWELL INTO EXISTING CONCRETE45 REBAR (2) 6" EBEDDMENT-DRILL 3/4" HOLE 6" DEPTH -EMBED EXISTING SLAB NMSIMPSON EPDXY -TIE" OR EQUAL -PROVIDE 6" AVAILABLE FOR LAP ONTO NEW REBARS SLAB PIN NOTE: 4" CONCRETE SLAB -ADD ADJACENT TO EXISTING- DOWELL INTO EXISTING CONCRETE 48" O/C W/8" #5 REBARS- DRILL 3/4" HOLE 4" EMBEDMENT - EPDXY W/ NON -SHRINKING "SIMPSON EPDXY ------------- TIE" (OR EQUAL). 7 Lu Jr3 co .......... //////III I 11111\00 2X3X.050 DIAG. BRACE TYP. I I HOST 36" O/H -- - STRUC. GUTTER ------ ----- ----------------- I - I I 2X2 . /2X2 I I I I 2X2 I I I °0 °0 FASCIA MOUNT X co X U) °O N co Z N N N N N I I I 2X2 ) 3" x .032"x1LB INSULATED' ROOF 1 3105-M14 Y4'!-1' SLOPE (FAIN.) FL756,1-R3 I I I I 2X2 2X2 I 2X2 I 45'-0" 0 N 2X4X.044 -----------------i-----------------T-----------------i----------------- I I I I I I I I\ I co co 1 X2 (TYP.) ca 0 (� co U) U) U) U) U) U) c o 00 N N N N N 2X3 (TYP.) N N N 4 "' o N 1X2 (TYP.) �8'-0"— 8'-0" T T-6" T 7'-6" I- T-6" --;- T-6" T-6" T 7'-6" -{ r 61'-0" !�I 1X2 2X2 DJ 2X2 DJ 0 b� 2X5 SMB N N N O x N X 2X5 SMB 0 a� /1X2 K-BRACE=2X3X.050 TYP U d- o r m 00 J 0 F-- M M ZZp O V WJOao� WTI; Ln� W W Q wm_ � Qo 2 1 � 0 Z J 2 Q W m Z W W Z w w m ca 8 o N 0 w U U N 0 cM ti O I— W w CL W QY J J Z LL O QU Z ~_ J 0 a cl) a Ocn� W bra DESIGN DATE: 11/17/2017 REVISION 1: 12115/2017 PAGE: REVISION 2: 1/18/2018 SCALE: NTS 2