HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGFlorida Building Code Online: Page 1 of 2
r r
r
Application Type
Revision
THESE PLANS AND ALI. PRCP(!SM WORK
Code Version
2014
ARIE SUBJECTTO ANY COMEC 61�sNS
Application Status
AApproved
Approved
'-REQUIR—ED BY F ELD INVECTOrfv THAT
Comments
. 104 Y B4 NECESSARY IN, ORDER TO
Archived
u
COPAPL� WITH ALL APPL.I'0ABLE CODES.
Product Manufacturer
Address/Phone/Email
Dynamic Metals
3201 SE Dominica Terace
CONCEALED FASTENERS OR ATTACHMENTS
Stuart, FL 34997
(772) 872-8030
ARE THE RESPONSIBILITY OF THE
Juan@dynamicmetal.net
CONTRACTOR OF RECORD
Authorized Signature Juan Martinez
Juan@dynamicmetai.net
M2�o
Technical Representative ST. LUCIE COUNTY
Address/Phone/Email BUILDING DIVISION
REVIEWED
Quality Assurance Representative FOR COMP C
Address/Phone/Email REVIEWED BY
DATE
Category Roofing PLANS AN E IT
MUST BE KE T O JOB OR
Subcategory Metal Roofing NO INSPECTION L BE MADE
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
® Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Thomas D. Sullivan
the Evaluation Report
Florida License PE-55358
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/06/2026
Validated By Joseph A Reed, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
FL21082 R1 COI FL21082 RO COI Letter of Independence
-Suilivan.odf
Standard Year
UL 580 2006
Method 1 Option D
http://www.floridabuilding.org/prlpr_app_dtl. aspx?param=wGEVXQwtDgsB ocg02%2b... 12/20/2017
} Florida Building Code Online -
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Page 2 of 2
04/13/2017
04/21/2017 FILE
-.<
04/21/2017
06/13/2017
FL # Model, Number or Name
21082.1 Dynamic Metals 1" Nailstrip
Aluminum
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-168.5
Other: Fasteners at 6" OC and 6" from ends.
Description
1" Nail strip, .032 Aluminum, non-structural roof panel
Installation Instructions
FL21082_RS II Dy.nmic M2k15_i, inrh..Nailstri,p Aluminum
ri,Ddf
Verified By: Thomas D. Sullivan 55358
Created by Independent Third Party: Yes
Evaluation Reports
FL21082 R1 AE FL21082.1 Eval Report 1.0 32,pdf
Created by Independent Third Party: Yes
21082.2
Dynamic Metals 1.5" Mech Seam
1.5" Mechanical Seam, 24 gauge Galvalume coated steel,
24ga Galvalume
non-structural, roof panel
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL21082 RS II Dynamic Metals 1.5 Mech Seam 24 ga
Steel r1.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Thomas D. Sullivan 55358
Design Pressure: +NA/-198.5
Created by Independent Third Party: Yes
Other: Field Install Uplift DP: 16"OC, 4"ends, equals 168.5
Evaluation Reports
psf (includes FS=2) Corner Install Uplift DP: 8"OC, 4"ends,
Ft-21082 Rl AE FL21.082.2 Eval Report 1..5 24 meth
seam:,iZrif
equals 198.5 psf (includes FS=2)
Created by Independent Third Party: Yes
21082.3 Dynamic Metals 1.5" Mech Seam
Aluminum
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-213.5
Other: Field Install Uplift DP: 16"OC, 4" ends, equals
131psf (includes FS=2) Corner Install Uplift DP: 8"OC, 4"
ends, equals 213.5 psf (includes FS=2)
2.1082.4 D namc Metals 5U Gri: p 6 ga
Steel
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-206
Other: Field Installation Uplift DP: 16" OC, 4" ends, equals
101 psf (includes FS=2) Corner Installation Uplift DP: 8" OC,
4" ends, equals 206 psf (includes FS=2)
1.5" Mechanical Seam, .032 Aluminum, non-structural
Installation Instructions
FI..21.082 R1 .I.I Dynamic Metals 1..5 Mech Seam Aluminum
rl__pdf
Verified By: Thomas D. Sullivan 55358
Created by Independent Third Party: Yes
Evaluation Reports
FL21082 R1 AE FL21082.3 Eval Report 1.5 32 meth
seam.Ddf
Created by Independent Third Party: Yes
�SV Crimp, 26 ga Steel, Galvalume, non-structural
(Installation Instructions
FL21082 R1 II FL21082.4FL21082 II FL21082.4 Drawinci 5v 26.odf26 d
Verified By: Thomas D. Sullivan 55358
Created by Independent Third Party: Yes
Evaluation Reports
FL21082 R1 AE FL21082A Eval Report 5v 26.odf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601_Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
I supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here ,
Product Approval Accepts:
Credit Card
i
Safe
http://www.floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgsB ocg02%2b... 12/20/2017
JB&B Engineering Consultants, LLCO mg, �?
5203. Silver Charm Terrace `� p_�'=
. � I
Wesley Chapel, FL.33544 DEC 0 1 2017
Phone: 813-545-1323
Email: TSullivanengcD-gmaii.com
Florida Certificate of -Authorization #3090Y:..,_..
Product Evaluation. Report'(111)
Dynamic 5V Crimp 26 Ga. Galvalume
Non-HVHZ
1.0 Product Manufacturer: Dynamic Metals, LLCCOPY
3201 'SE Dominica Terrace _
Stuart, FL 34997
2.0 Code edition: Florida Building Code 5th edition (2014)-Building Volume Non-HVHZ
Sections 1504.3.2 and 1504.7
3.0 Evaluation Method: Engineering Evaluation (method 1D) in accordance with 61G20-3.005 F.A.C.
4.0 Product Category: Roofing
4.1 Product Sub -Category: Metal Roofing
6.0 Product Description:
5.1 General Description: Dynamic 5v crimp 26 gage Galvalume non-structural. roof deck
5.2 Min Fy=50 ksi steel conforming: and Florida Building Code 5t.h edition (2014) section 1507.4.3.
Paint finish optional
5.3 Panel Thickness: 26 Gage (0.0217") minimum coated thickness
5,4 Corrosion Resistance to comply with Florida Building Code 5th edition, section 1607.4.3
5.5 Width: 24" maximum coverage
5.6 Rib Height: 3/8" major rib height @ 12" o.c.
6.0 Panel Fastener: #10 x 1.1/2" WoodZac Hilo HWH fasteners with bond washer at the overlaps and
each panels center rib or equi..Corrosion resistance per Florida Building Code 5th edition (2014),
sections 1506.6 and 1507.4.4
6.1 Substrate Description: 1layer of 30# organic felt paper.or other underlayment compliant with FBC
chapter 1.5 over minimum 7/1.6" OSB (or 15/32" 47ply APA plywood), over 2x SYP rafters spaced no more
than 24" o.c. Substrate must meet all applicable requirements and be designed with the Florida Building
Code 51h edition (2014)
6.2 Design Uplift Pressures:
6.1 Field Installation 202.0 psf/2=101.0 psf (Fasteners spaced 16" o.c.)
6.2 Corner Installation 412.0 psf/2=206.0 psf (Fasteners spaced 8" o.c.)
7.0 Code Testing Performance Requirements:
7.1 UL 580-06-Test for Uplift Resistance of Roof Assemblies
7.2 UL 1897-04-Uplift Test for Roof Covering Systems
8.0 Performance Test Results Summary:
8.1 Architectural Testing; Inc. West Palm Beach, FL (TST 1527), Report #G1195.02-450-44-R1
8.1.1 Signed/Sealed by Joseph A. Reed, P.E. on March 17th, 2017
8.1-.2 UL580-06/ UL 1897-04 Field Installation (-202.0 psf)
8.1.3 UL580-061 UL 1897-04 Corner Installation (-412.0 psf)
JB&B Engineering Consultants, LLC
5203 Silver Charm Terrace
Wesley Chapel, FL 33544
Phone: 813-545-1.323
Email: TSullivanengCc_cmail.com
Florida Certificate.of Authorization #30903
9.0 Installation Instructions:
9.1 Per manufacturer's installation instructions and fastening patterns described herein
10.0 Design Procedure: Based on the dimensions of the structure, appropriate wind. loads are
determined using Chapter 16 of the Florida Building Code'2014 for roof cladding wind loads. These
component wind loads for roof cladding are compared to the allowable design pressure's listed herein.
The design professional shall select the the appropriate: erection details to reference in his drawings for
proper fastener attachment to his/her structure and analyze the. panel fasteners. for pullout and pullover.
Support framing must be in compliance with Florida Building Code 2014 chapter 22 for steel, chapter 23
for wood and chapter 1.6 for structural loading.
11.0 Limits.and Conditions of Use:
11.1 Maximum allowable design pressures listed in this report
11.2 Fire classification has not been considered and is outside the scope of this report
11.3 Panels were not evaluated structurally to resist shear diaphragm, axial, transverse or
racking loads
11.4 Alternate conditions not specifically addressed by this approval shall be designedby a
registered Florida Professional. Engineer or Architect
11.5 The structural adequacy of the substrate bearing the wind loads superimposed by this
product are the responsibility of others
11.6 Underlayment shall comply with the Florida Building Code 5th edition (2014)
11.7 Minimum slope shall comply with the Florida Building Code. 5t" edition (2014, including
section 1507.4.2 and in accordance with the manufacturers recommendations. For
slopes less than 3:12, lap sealant must be used in the panel side laps
12.0 Quality Assurance Entity: The manufacturer has established compliance of'roof panel products in
accordance with the Florida Building Code and Rule 61 G20-3.005(3) for manufacturing under a quality
assurance program audited by an approved quality assurance agency.
13.0 Certificate of Independence: Pursuant to the:requirements of 61G20-3 F.A.C, I hereby, certify that
this Florida Professional Engineer, performing this evaluation, does not have nor will acquire an interest in
any company manufacturing or distributing products for which the report is being'issue& This is also to
certify that this Florida Professional Engineer, does not have,nor will acquire a financial' interest in any
other entity involved in the approval process of this product.
14.0 Certification:. In the professional opinion of this evaluating engineer the aforementioned, product,
meets the requirements of the Florida Building Code 20.14 (5th edition), specifically sections 1,504.3.2 and
1504.7 for us%lgir®n.Ir V, Z, when utilized within the limits of use noted herein.
o!I o. sv<
e
FI
55365 . m COPY
+�,,
10
Thom ag I•v R.fl
FL PE# •°•••° 0
Total Page��NA` ese0�
DYNAMIC .METALS, LLC
9201 SE L'ominica :Terrace
Stuari,. Florida 34997
JB'&B ENGINEERING, LL C
CONSULTING ENGINEERS
5203 SUver Charm Terrace
Wesley, Chapel, FL 33544
Phone (818)545—f328
Email TSullivanerg®gmalLcam,
FL Certiftcate gf.AuthorizaMm #40903
DYINAMIC 5V"; CRIMP26GA
24" PhkiiYittttt Net CoVerage
COPY
Panel Profile
Ncmtlw 12" a:c. Nomiral 17. c-c, j
#10 x 1-1/2'WoodZac Hilo HWH fasteners: with bond washer
_ t —1--lor equal)
ParelOverlap
J�
O1613 _ ti S,`1' or gmates Piyumd. or
-VVlxxl plank
MAXIMUM DESIGN UPLIFT PRESSURE=101.0 PSF
9♦ �� S'D.es a FASTENERS TO :BE SPACED ,16' O.C. . .
P v
EN
or �e • a MAXIMUM DESIGN ,UPLIFT PRESSURE=206(0: PSF
•, C S.. +e m FASTENERS TO'BE..SPACED 8" O:C.
N 55358
T �- + o Client Name: DYNAMIC METALS, LLC
•.� Z
�, •, P e°�Z Project Name: DYNAMIC 5V CRIMP 26 GAGE GALVALUME
p y
THOM q' �o � Fp ,P to tiYt1oI ORIDA BUILDING CODE 5TH ED. (2014) Project -Address: 'FLORIDA PRODUCT APPROVAL
.FL #5�
SEAL ;t JOB NO. 215=1050 DATE: 04-12-2017