HomeMy WebLinkAboutWIND SPEED & EXPOSURECONTRACTOR: Master Craft Alumin ' DESIGN CRITERIA; Applicable Codes, Regulations, and Standards 1. The 5th Edition (2014) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association, Inc. Washington, D.C., 2010 Edition and the Guide to Aluminum Construction in high wind areas, 2010. 3. ASCE 7-10. Wind Loads' 1. Building Occupancy Category, Paragraph 1604.5 and Table 1604.5: Risk Category 1. 2. Basic Wind Speed, Figure 1609C, State of Florida Debris Region & Basic Wind Speed, Paragraph 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed: VuLT =150 MPH, VASD =116 MPH 3. Exposure Category, Paragraph 1609.4.3: Exposure B 4. Building Category for Aluminum Structures, Paragraph 2002.6: Building Category 1- Screen Room: Non -Habitable, Unconditionel Scope of Work: Screen room and carport only. Does not include analysis of remaining existing structure. Roof Type 1. Roof Type: MONOSLOPE 2. Roof Material: 3" x 48" x 0.024" composite panel Elite 2000,1.0 density foam, Florida Product Approval Number FL 7561-R3. Foundation Design Existing concrete. No additional concrete footing or slab is required to resist the loads imposed by the proposed construction if the existing slab is a minimum 4" thick with an 8" x 8" thickened slab edge and in sound condition, free from structural cracking, spallin% or other deterioration. Specifications The following specifications are applicable to this project: 1. All work shall be in accordance with the Sth Edition (2014) Florida Building Code, and any other applicable local codes and regulations. 2. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization of Suncoast Aluminum Engineering, LLC. 3. Screen Material: Design based on 18/14 or 20/20 Better View. Any other material must be approved. 4. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plated to ASTM B633, or coated stainless steel series "300", or uncoated stainless steel series "400". 5. All Self Mating Beam Sections are to be stitched with either # 14 screws 6" from ends and 24" center to center or #12 screws 6" from ends and 12" center to center. 6. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components: i. Portland Cement Type 1,- ASTM C 150 ii. Aggregates - Large Aggregate 3/4" max - ASTM C 33 iii. Air entraining +/- 1 % - ASTM C 260 iv.Water reducing agent - ASTM C 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: i. Reinforcing Bars - ASTM A615, grade 60 ii. Welded wire fabric - ASTM A185 c. Concrete slump at discharge chute not less than 3" or more than 5". Water added after batching is not permitted. d. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 7. All flashing and weatherproofing shall be provided by the contractor. 8. Door location shall be determined by contractor in the field. 9. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. WIND SPEED AND E3- ' ' .;URE HAVE BEEN DETERMINED iG THE ADVANCED TECHNOLOGY COUNCIL'S WEBSITE AND GOOGLE EARTH. 7'-0" " = i l Im =0'w 0 P Y� � �; O o O p 0. p'. J0.5 C. UJIy••••....••�'o KAU R \\ ® N P/// 1, 1 �LSEAL\ A-3 8'-9" 8'-9 8'-9" 2X6SMB 4TH WALL 0 3'X48'XO.024' 1.0 DENSITY FOAM COMPOSITE PANEL S-3 A-3 2X6SMB EDGE BEAM pp `' ly 4 ,cf i7 -ALI.P R.Cnnr, r��ty ��L•�e't t: 1f^r� 7 , 1 , r.�^ ' �pp:.��.if N�•a.• �i4, ('1�1�-:IIIY'�::ii'��yT!' j,tt,li�52 �C,,.'•1""�;S�L�".lrli�•'liv { t_IN Cf1-nnr, A4! I /1�.P rye,. a tom.. r��.reic vp1Gv. 12'-9" T END BEAM MISER �J2X3 11, 111 070PEI BEAM BEAM 7'-1 7'-1 � LL 28'-0" - 15'-0"- :A S-4 3'X48'XO.024" A-3 / COMPOSITE PANEL CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE n n o 0 0 0 0 o C 0 0 X 0 0X M 1� X X e 2X3 2X3 1 X30.B. 1 X30.B. B-1 B A-2 A-2 8'-9" 7'-1 4" 7'-1 4' t'ONIRA,,ffOR OF I OORD ST. LUC'E COieINTY BUILDING DIVISION REVIEWED FOR COMPLIANCE REVIEWED BY DATE p PLANS AND PERMIT MUST BE KEPT ON JO OR NO INSPECTION WILL BE MADE In 0 [3CCLa ui 0UJ n n U- ~ O CH o � CG am �m W d= �M W �z pz �z Qz =� 0U Z W I- ii cc LL 0 0 Z , J � = J � J Z z o Q W -. JT8 O W w m lro ln�� U ZIbQVV Z V' 'n3^C Z I to W , ul-"LL t71 Ln LLJ tY X 0 H Q ww XU O-1 W U) m rn ZItLLM a n�ma. GD DATE DRAWN 11/09/17 SHEET NO: A-1 ` ' ALUMINUM MEMBERS DIMENS;> ll HOLLOW SECTIONS '• 2 x 2: 2" x 2" x 0.046" ��` .•••• •. 2x3: 2"x3"x0.050" '�' 2x4: 2"x4"x0.050" ��� 2 x 5: 2" x 5" x 0.050" SECTIONS OPEN BACK �-- WV I I Q O z_ Ix2: 1"x2"x0.040" __ ( N _ 1 x3: 1"x3"x0.045" co` SNAP SECTIONS I I CHAIR RAIL MEMBER I I i �0 ` � �\ •:( 2 x 2 Snap: 2" x 2" x 0.045" 2 3 Snap: 2" 3" 0.050" I I , , . x x x 2 x 4 Snap: 2" x 4" x 0.045" 3X3X0.070I dR t P� SELF MATING (SMB) I $MINA i 2 x 4 SMB: 2" x 4" x 0.044" x 0.100" 2" x 2" x 1 /8" ANGLE W/ 2 x 5 SMB: 2" x 5" x 0.050" x 0.100" I I (4) #10 x 5/8" EACH SIDE I ❑ 2x6SMB:2"x6"x0.050"x0.120' I I 3 x UPRIGHT 2 x 7 SMB: 2" x 7" x 0.05T' x 0.120" I I 1"x 3" OB W/ 1/4"CONCRETE I I I I 2" x x x ALUM ANGLE EACHH SIDE OFF UPRIGHT O Lu W 2 x 8 SMB: 2" x 8" x 0.072" x 0.124" SCREW ANCHOR 6" FROM I I WI 3/8" DIA. x 3" CONCRETE U a C 2 x 9 SMB: 2" x 9" x 0.072" x 0.124" 2 x 10 SMB: 2" x 10" x 0.092" x 0.398" UPRIGHT & AT 24" O.C. I I (MIN. 2 3/4" EMBED.) ANCHORS ON EACH SIDE (3) #12 x 3/4" SMS SCREWS I I LLI cc MINIMUM FASTENER EDGE DISTANCE: 1/2" TH Y4J.J�,,.n j s0 LL Ii o pC S`^� MINIMUM FASTENER SPACING: 3/4" — — .. — — — ° $1 FBjEC ; To ANY 1. � �'t i�� ���ry�! ! 3A W Q W w W a m J CONCRETE SCREW ANCHOR: "-> LAKE f {eL: vl:fl:...0 By S i:., D it, �1*'���' Z a � W SIMPSON TITEN HD OR EQUIVALENT ° ° e° b '` E l�: �rl' e1r:=�-•y a resit •a:H:. `) BF It�t:L•` :3�f`E`:) I�" if1 9 N �z Qz SHEET METAL SCREWS (SMS): ° Z = - O ITW / BUILDEX OR EQUIVALENT •a J ) t �'�ilI mi i�J! i l t6� !P'jl ��'�S� ! �� r• 4:i:� ( w uJ w LL i C G C CHAIR RAIL T- UMFGHT DETAIL B 3" x 3" POST TO DECK CONNECTION DETAILS A_2 SCALE: NTS Z , SCALE: NTS A-2 J PM 1 pl. n Pv z$Q I.— En . m 2i W W� m m W R3 LAI �� a Q VI < LLJ Mno z O L) Z ^US p Q N N = z (� in o 1/8" x 2" x 2" EXTRUDED ANGLE 5052 H-32 ALLOY • • (3) #12 x 3/4" SMS � Z O ILL • INTO DJ VI LILI ti u LL 21M MIN CONC ' - I I SLAB FOOTING q ; ° ANCHOR EMBEDMENT' ° e', e SEE PLAN : s 3" x 3" x 0.093" POSTLLJ N I W I I SIDE VIEW ~ p ww I I I 2" x 2" x 3" x 1/8" ALUM ANGLE EACH SIDE OF UPRIGHT 3/8" DIA. CONCRETE N LJJ a) 00 I I W/ 3/8" DIA. x 3" CONCRETE (1) I I UPRIGHT � I I SCREW ANCHORS w U) I I ANCHORS ON EACH SIDE (21/4" CONC. EMBED) PRE -HUNG c Z O I I (3) #14 x 3X' SMS SCREWS DOOR JAMB O0i J a ch CL LL - - DRAWN BY 4� °e a •fit GD DATE DRAWN ° e ° n ' 1" x 3" BASE PLATE ANCHORED TO CONC W/ 1/4" `,• _11 /09/17 CONCRETE SCREW ANCHOR ° q ' • . n e ' REVISION (MIN. 1 1/4" EMBED) 6" MAX EACH SIDE OF POST r a s •.. 'a e4 a Q AND 24" O.C. MAX .® •4,a a B 3" x 3" POST TO DECK CONNECTION DETAILS FRONT VIEW SCALE: NTS A-2 DJ-1 UPRIGHT TO CONCRETE PRE -HUNG SHEET NO: A_2 DOOR LOCATION DETAIL A-2 SCALE:NTS { / (4) #14 x 4 7/8" SMS W/NEOPRENE WASHERSPER�D.'✓x W x 0.062" ALUM ax:•&a�•r 'ti;Y PANELFILL RECEIVING CHANNEL Wr �°+sa':f+< q .,d,CO]IP1 G ` ' • A •, (/ W/ #12 x 3/4" TOP AND r • 1, tit � `> <' % � d Q BOC:� TTOM AS END CAP y / `may < ' f K{d�� h ` � Jr (J LIJ �At `{'��?• x�) y"i;5.��'•a`,4,'.`x,rca •sE§1� .�ar`�:. � O \ Q ' 3" COMPOSITE PANEL (�' r FLASHING � Z (/ Q . • (/) �. •' (/� 2"x3"x0.070"TOP RAIL -NO //�j '7 ` •��•�•�R•Q�`\V\\\ ANGLE REQUIRED 3 ///j \\\ UNLESS SPLICED OR II �I ROOF PANEL ANEL I I It1 I 1 1 ` ' CORNER - ATTACH w/ (4) #10 x 4" LG II +� �+'• ''a ��, s PROFE SIONAL SEAL Wx_UPRIGHT SEE DWG. FOR UPRIGHT SIZE ❑ 2" x 3" TOP RAILw/ ev.u.+'Fs D3, ym �x3 x 4 #10 x 4" SMS irn a 4 + 1w f}, .Y'.w's t,�:>'; INTO POST ryy" i t4°ia�#'1'r.�"1 '??:!i w4" s� :, �"`yy�.;:;.1= �e�rs (4) #14 x 4 71W SMS W/ NEOPRENE FACED EXISTING WASHER EA. PANEL BUILDING I u W LLI LJ d d OC — x„G • `�, r �� :;a * �M' a•r' E's`, _,?."..'. <w' 2"x2"x3"LG a.>^. >rx.,_de_. 2"x2"x3"LG r.t r (3) 3/8" DIA. THRU BOLTS fD: LL IILLLY � $ w co x 1/e" ANGLE x 1/8" ANGLE 2" x 6" SMB 0 Q W w W co J a- g i — 3" x 3" POST LWL! Z y 2 . 2 z 0 z (4) #10 x 314' (4) #10 x 3W I z Q z SMSINTO SMS INTO I I -- Z O u Z d, o SCREW BOSSES SCREW BOSSES W 2=1 O ~ LL w- (2) INTO TOP RAIL I I (2) INTO TOP RAIL I I (2) INTO POST (2) INTO POST — CONNECTION AT CORNER CONNECTION AT SPLICE S—'I COMP. ROOF TO POST 4TH WALL DETAIL A-� SCALE: NTS Z V c J~ S 2 X 3 TOP RAIL CONNECTION TO 3 X UPRIGHT j J A-3 SCALE: NTS .pL'+�+ �.t r /�} i f77,:.L E ri '�� NS .�ili ,) A Pgy P ••^a iPi s 1, 1'Ii=7„ J Q v.yij": Z AIR -- -S i li j g. 'j' „'. t: �l — I— c" - rs •x1: .i•1 Ji+Jlt;j �z�.. N W W]cPcP W �E y p' By �.'i !'s`.''r..'��J ityt"1'�`. �:�•'S` i.jjA; • i r?4� �'1 i:'l t.LLNN m Q W In oe ,mn ,`i z i { nir lE!(.rt.:J�:i2: IN Gir'i_"`F ¢ n n ¢ ,: :LiI��7 ���8 11� .' I H'Ar i I/'� p( c P.i 1"]+...n 6:. Pii �. %stiz tmD n W au. .m., U iW-• LL (4) #14 x 4 7/8" SMS W/ (4) #14 x 4" SMS W/ NEOPRENE FACED FLASHING (4) #14 x 4 7/8" SMS W/ NEOPRENE FACED NEOPRENE FACED WASHER EA PANEL 3" COMPOSITE PANEL WASHER EA. PANEL WASHER EA. PANEL 3" COMPOSITE ROOF PANEL :y Fps' *sLcst 4', q ���a-�r �,,��xrxaa .cam �,:�",��;,ysx°•,'f�„ ;,��,�.�•�,'.' �;:.r 2" x 3" TOP RAIL t s4.s s s• s d 4 #10 4" SMS ay t§ 4 W&i ' P ' ^' r. ,.K. X'>, #:a�� a,°;> �' t5 •'a �•iY ,'/. .,":r''h`t &�yp�D« " •Ls;/i'j+W�'ixJysCC bAa^?!(a 'Y`• .4 4. h�L L'A. v�i.Jf, t•.-.��.. .1. l X' v'r.Ni9. a.T���t'�'�"�'S<xa°r.. '-1a 'r•i. �•v g'� -^ i+Y: � �>��i4'� "Cyr i"d"G`. �fe;�;+i'�'ri,�%$a4Lt�L' ��yy'r-t••."$" , >r+{ w! x ...�.:v`�4�1 bV'.-11T• Oa'S.. I" •✓3�s�*j.t ( ) .Ri•A%}%S'• :jha +K ti-'i �vr`fl..i, S+4a«. x°� '4.✓s �s'`''�n 4 � gy T .�`: ,a'� `,�•,•;.. 4'".`'sY tD:,�R:dt :3�naiPa �' INTO POST S �e„'�".T EP.!S •;a.' t" es s'iae„t {{ ,,rY:.. # +�A b .4 +',Y°' '.C•A.�.w 1. Y r.�q>ya3:"ie sas.�.ta`' �� t«, xa; I ±.„ f,Ya h�,»�i+ i,,^`: ''t;f r•.. � C{x.d �.: i, 1{�-�a� «.+•:lk .;�� sJas b� WT t}.,}•+S'4ei :. � �''s?' ,�:C ,a„as'. �.s<«xe°§ s,�' a._a;. ,�x»w•�`: ..�'` F�'��:sa>'�`°'�"��`-•S}ti.:' � +?•>x''� ':tid' zr �-•'• C^a `...�t�,.:e�"-L'-t`•!�" �r� �.�e#'{,�rFxs`•ix;,mta , :iY ly i�'..+.dbgtt. `�,,.�` i' 8^. +.A:. >i,^"�..:..rx+;-:i' �??•' ;'"is'�: ?+'r',!'. ', -x' — _.._ — — �. "- �% *'Iqa^' •sc.: k+^.:^ :.< a • 2" x 2" x 3" LG W � fY Ill. �:`t`'�''^+:� r '.`tr.�ra'°r`z�•,'��`•:.:. .... ".' x 1/e"ANGLE - ..... ..... .. ....... 0 -- -- -3" COMPOSITE PANEL �' 0 W W_ 2" x 3' x 0.050" s, I EXISTING I 3" x 0.062" ALUM • " (4) #10 x 3/4" Q 0 END BEAM BUILDING RECEIVING CHANNEL SMS INTO 0 J — I W/ #10 x 34' TOP AND I (3) 3/8" DIA. BOTTOM AS END CAP THRU BOLTS SCREW BOSSES • i (2) INTO TOP RAIL = F N W (n 00 1 1/8" x 21/8" x1 1/8" x 0.050" I — — — i (2) INTO POST O M ALUM RECEIVING CHANNEL I 3/4" SMS EACH 2" x 6" SMB qZ M W/ (3) #12 x I I d N (L LLi SIDE OF BEAM & (2) 3/8" DIX THRU BOLTS INTO THE POST I x 0.093" 2" x 6" SMB DRAWN BY 3/8" DIA. THRU BOLT I I I POST 1 ALUM x 2" x 1 VIN1/8" x 6" x CHANNEL ALUM RECEIVING CHANNEL C7D 2" x 6"SMB W/ (5) #14 x 3/4" SMS INTO DATE DRAWN EACH SIDE OF BEAM & (5) 3" x 3" POST — — #14 x 1" SMS INTO CORNER POST 11 /09/17 REVISION S-3 COMPOSITE ROOF TO POST CONNECTION S'4 &2 COMP. ROOF TO CORNER POST 4TH WALL DETAIL /� SCALE: NTS COMPOSITE ROOF TO POST CONNECTION SCALE: NTS SCALE: NTS /°`-3 „_3 A-3 SHEET NO: A-3