PROJECT INFORMATION
L--r wrigni Projecty Summary Job: Date: Dec 03,2021 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For: LOWER RESIDENCE LOT 1069 NETTLES ISLAND, JENSEN BEACH, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23863 Btuh Structure 16017 Btuh Ducts 4512 Btuh Ducts 6359 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28375 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmenf sensible load 21258 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2925 Btuh Ducts 1716 Btuh Central vent (0 cfm) 0 Btuh Heating Coolingg (none) Area (ft2) 1672 1672 Equipment latent load 4641 Btuh Volume (ft3) 13824 13824 Air changes/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 25899 Btuh Equiv.AVF (cfm) 88 46 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR40311-1 AHRI ref Coil TEM6AOC36H31++TDR AHRI ref 7567544 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 8.0 kW Sensible cooling 20580 Btuh Heating output 27328 Btuh Latent cooling 8820 Btuh Temperature rise 25 °F Total cooling 29400 Btuh Actual air flow 980 cfm Actual air flow 980 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. )Oft—ord- W riigI 2021-Dec-03 15:32:15 _ Right-SuiteO Universal 2021 21.0.02 RSU08101 Page 1 E:\Documnets\Wrightsoft HVAC\LOWER RESIDENCE.rup Calc=MJ8 Front Door faces: S IL : W I Nyl l Right-J®Worksheet Job: Entire House Date: Dec 03,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name Entire House LIVING/DINING RM 2 Exposed wall 229.0 ft 49.0 ft 3 Room height 8.3 ft 8.0 ft heat/cool 4 Room dimensions 1.0 x 296.5 ft 5 Room area 1671.5 ft2 296.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AB-0fcs 0.183 n 5.12 3.18 400 239 1224 761 200 95 485 302 2 glazing,clr low-e 0.650 n 18.20 13.26 15 0 273 199 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 13.26 41 0 743 541 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 9.50 45 0 819 427 45 0 819 427 11 2 glazing,clr low-e 0.650 n 18.20 9.50 60 0 1097 573 60 0 1097 573 13AB-Ofcs 0.183 e 5.12 3.18 608 534 2736 1700 88 68 348 217 2 glazing,clr low-e 0.650 a 18.20 33.77 6 0 109 203 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 8 0 146 270 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 12 0 218 405 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 20 0 366 679 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 28.23 8 0 146 226 0 0 0 0 2 alazina,clr low-e 0.650 a 18.20 18.64 20 0 364 373 20 0 364 373 W 13AB-Ofcs 0.183 s 5.12 3.18 352 319 1635 1016 0 0 0 0 I�; CGCII 2 glazing,clr low-e 0.650 s 18.20 14.99 6 6 109 90 0 0 0 0 2 glazing,clr low-e 0.650 s 18.20 14.99 12 12 218 180 0 0 0 0 2 glazing,clr low-e 0.650 s 18.20 14.99 15 15 273 225 0 0 0 0 VI✓ 13AB-Ofcs 0.183 w 5.12 3.18 610 573 2936 1824 104 85 436 271 I;; GCGII 2 glazing,clr low-e 0.650 w 18.20 20.97 12 0 218 252 0 0 0 0 2 glazing,clr low-e 0.650 w 18.20 18.64 6 0 109 112 0 0 0 0 2 alazina,clr low-e 0.650 w 18.20 18.64 19 0 349 357 19 0 349 357 Cr 16X19-0md 0.408 1.59 1.37 983 983 1559 1345 99 99 158 136 F 22A-tl)h 1.358 38.02 0.00 952 145 5522 0 297 49 1863 0 6 c)AED excursion 0 -37 Envelope loss/gain 21169 11758 5920 2618 12 a) Infiltration 2694 760 536 151 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 3500 0 Subtotal(lines 6 to 13) 23863 16017 6456 2770 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 23863 16017 6456 2770 15 Duct loads 19% 40% 4512 6359 19% 40% 1221 1100 Total room load 28375 22377 7677 3869 Air required(cfm) 980 980 265 169 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Dec-0315:32:15 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 1 '� E:\Documnets\Wrightsoft HVAC\LOWER RESIDENCE.rup Calc=MJ8 Front Door faces: S IL : W I Nyl l Right-J®Worksheet Job: Entire House Date: Dec 03,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name KITCHEN OFFICE 2 Exposed wall 10.0 ft 23.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 12.0 x 10.0 ft 12.0 x 11.0 ft 5 Room area 120.0 ft2 132.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AB-OFcs 0.183 n 5.12 3.18 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 13.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 13.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 9.50 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.650 n 18.20 9.50 0 0 0 0 0 0 0 0 13AB-Ofcs 0.183 e 5.12 3.18 80 80 410 255 88 76 389 242 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 12 0 218 405 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 28.23 0 0 0 0 0 0 0 0 2 alazina,clr low-e 0.650 a 18.20 18.64 0 0 0 0 0 0 0 0 W 13A zing, 0.183 s 5.20 3.99 0 0 0 0 96 81 415 258 I�; CGCII 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 15 15 273 225 VI✓ 13A zing, 0.183 w 5.20 3.97 0 0 0 0 0 0 0 0 I;; GCGII 2 glazing,clr low-e 0.650 w 18.20 20.97 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 w 18.20 18.64 0 0 0 0 0 0 0 0 2 alazina,clr low-e 0.650 w 18.20 18.64 0 0 0 0 0 0 0 0 Cr 16X19-0md 0.408 1.59 1.37 0 0 0 0 0 0 0 0 F 22A-tl)h 1.358 38.02 0.00 120 10 380 0 132 23 875 0 6 c)AED excursion -32 -20 Envelope loss/gain 790 223 2170 1110 12 a) Infiltration 109 31 252 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2150 350 Subtotal(lines 6 to 13) 900 2403 2422 1531 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 900 2403 2422 1531 15 Duct loads 19% 40% 170 954 19% 40% 458 608 Total room load T1070 3358 2880 2138 Air required(cfm) 37 11471 99 94 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Dec-0315:32:15 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 2 '� E:\Documnets\Wrightsoft HVAC\LOWER RESIDENCE.rup Calc=MJ8 Front Door faces: S IL : W I Nyl l Right-J®Worksheet Job: Entire House Date: Dec 03,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name ENTRY BATH 2 Exposed wall 0 ft 10.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 104.0 ft 1.0 x 65.0 ft 5 Room area 104.0 ft2 65.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AB-Ofcs 0.183 n 5.12 3.18 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 13.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 13.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 9.50 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.650 n 18.20 9.50 0 0 0 0 0 0 0 0 13AB-Ofcs 0.183 e 5.12 3.18 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 28.23 0 0 0 0 0 0 0 0 2 alazina,clr low-e 0.650 a 18.20 18.64 0 0 0 0 0 0 0 0 W 13A zing, 0.183 s 5.20 3.99 0 0 0 0 0 0 0 0 I�; CGCII 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 VI✓ 13A zing, 0.183 w 5.20 3.97 0 0 0 0 80 80 410 256 I;; GCGII 2 glazing,clr low-e 0.650 w 18.20 20.97 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 w 18.20 18.64 0 0 0 0 0 0 0 0 2 alazina,clr low-e 0.650 w 18.20 18.64 0 0 0 0 0 0 0 0 Cr 16X19-0md 0.408 1.59 1.37 0 0 0 0 0 0 0 0 F 22A-tl)h 1.358 38.02 0.00 104 0 0 0 65 10 380 0 6 c)AED excursion 0 4 Envelope loss/gain 0 0 792 252 12 a) Infiltration 0 0 110 31 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 0 0 902 283 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 360 113 14 Subtotal 0 0 1262 396 15 Duct loads 19% 40% 0 0 19% 40% 239 157 Total room load 0 0 1501 553 Air required(cfm) 0 0 52 24 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Dec-0315:32:15 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 3 '� E:\Documnets\Wrightsoft HVAC\LOWER RESIDENCE.rup Calc=MJ8 Front Door faces: S IL : W I Nyl l Right-J®Worksheet Job: Entire House Date: Dec 03,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name STAIR STORAGE FOYER 2 Exposed wall 4.0 ft 14.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 4.0 x 4.0 ft 6.0 x 9.0 ft 5 Room area 16.0 ft2 54.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AB-0fcs 0.183 n 5.12 3.18 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 13.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 13.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 9.50 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.650 n 18.20 9.50 0 0 0 0 0 0 0 0 13AB-Ofcs 0.183 e 5.12 3.18 0 0 0 0 64 38 194 121 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 6 0 109 203 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 20 0 366 679 2 glazing,clr low-e 0.650 a 18.20 28.23 0 0 0 0 0 0 0 0 2 alazina,clr low-e 0.650 a 18.20 18.64 0 0 0 0 0 0 0 0 W 13A zing, 0.183 s 5.20 3.99 0 0 0 0 48 42 109 134 90 I�; CGCII 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 6 6 109 90 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 VI✓ 13A zing, 0.183 w 5.20 3.97 32 32 164 100 0 0 0 0 I;; GCGII 2 glazing,clr low-e 0.650 w 18.20 20.97 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 w 18.20 18.64 0 0 0 0 0 0 0 0 2 alazina,clr low-e 0.650 w 18.20 18.64 0 0 0 0 0 0 0 0 Cr 16X19-0md 0.408 1.59 1.37 0 0 0 0 0 0 0 0 F 22A-tl)h 1.358 38.02 0.00 16 4 152 0 54 14 532 0 6 c)AED excursion -2 -20 Envelope loss/gain 316 100 1526 1206 12 a) Infiltration 44 12 153 43 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 400 Subtotal(lines 6 to 13) 360 113 1679 1649 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -360 -113 0 0 14 Subtotal 0 0 1679 1649 15 Duct loads 19% 40% 0 0 19% 40% 318 655 Total room load 0 0 1997 2304 Air required(cfm) 01 0 69 101 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Dec-0315:32:15 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 4 '� E:\Documnets\Wrightsoft HVAC\LOWER RESIDENCE.rup Calc=MJ8 Front Door faces: S IL : W I Nyl l Right-J®Worksheet Job: Entire House Date: Dec 03,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name STAIRS UP WIC 2 2 Exposed wall 17.0 ft 7.0 ft 3 Room height 16.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 56.5 ft 7.0 x 6.0 ft 5 Room area 56.5 ft2 42.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AB-0fcs 0.183 n 5.12 3.18 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 13.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 13.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 9.50 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.650 n 18.20 9.50 0 0 0 0 0 0 0 0 13AB-Ofcs 0.183 e 5.12 3.18 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 28.23 0 0 0 0 0 0 0 0 2 alazina,clr low-e 0.650 a 18.20 18.64 0 0 0 0 0 0 0 0 W 13AB-Ofcs 0.183 s 5.12 3.18 64 64 328 204 56 56 287 178 I�; CGCII 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 VI✓ 13AB-Ofcs 0.183 w 5.12 3.18 209 191 977 607 0 0 0 0 I;; GCGII 2 glazing,clr low-e 0.650 w 18.20 20.97 12 0 218 252 0 0 0 0 2 glazing,clr low-e 0.650 w 18.20 18.64 6 0 109 112 0 0 0 0 2 alazina,clr low-e 0.650 w 18.20 18.64 0 0 0 0 0 0 0 0 Cr 16X19-0md 0.408 1.59 1.37 57 57 90 77 42 42 67 57 F 22A-tl)h 1.358 38.02 0.00 57 17 646 0 6 1 38 0 6 c)AED excursion 191 -3 Envelope loss/gain 2368 1443 392 232 12 a) Infiltration 373 105 77 22 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2741 1548 468 254 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 63 39 0 0 14 Subtotal 2805 1587 468 254 15 Duct loads 19% 40% 530 630 19% 40% 89 101 Total room load 3335 2217 557 355 Air required(cfm) 1151 971 19 16 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Dec-0315:32:15 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 5 '� E:\Documnets\Wrightsoft HVAC\LOWER RESIDENCE.rup Calc=MJ8 Front Door faces: S IL : W I Nyl l Right-J®Worksheet Job: Entire House Date: Dec 03,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 W/DARER 2 Exposed wall 23.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 11.0 x 12.0 ft 1.0 x 67.0 ft 5 Room area 132.0 ft2 67.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AB-0fcs 0.183 n 5.12 3.18 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 13.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 13.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 9.50 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.650 n 18.20 9.50 0 0 0 0 0 0 0 0 13AB-Ofcs 0.183 e 5.12 3.18 96 88 451 280 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 8 0 146 270 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 28.23 0 0 0 0 0 0 0 0 2 glazina,clr low-e 0.650 a 18.20 18.64 0 0 0 0 0 0 0 0 W 13A zing, 0.183 s 5.20 3.99 88 76 389 242 0 0 0 0 I�; CGCII 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 s 18.20 14.99 12 12 218 180 0 0 0 0 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 VI✓ 13A zing, 0.183 w 5.20 3.97 0 0 0 0 0 0 0 0 I;; GCGII 2 glazing,clr low-e 0.650 w 18.20 20.97 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 w 18.20 18.64 0 0 0 0 0 0 0 0 2 glazinq,clr low-e 0.650 w 18.20 18.64 0 0 0 0 0 0 0 0 Cr 16X19-0md 0.408 1.59 1.37 132 132 209 181 67 67 106 92 F 22A-tl)h 1.358 38.02 0.00 88 15 583 0 4 0 0 0 6 c)AED excursion -20 -1 Envelope loss/gain 1997 1133 106 90 12 a) Infiltration 252 71 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 300 0 Subtotal(lines 6 to 13) 2248 1504 106 90 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 111 68 14 Subtotal 2248 1504 217 158 15 Duct loads 19% 40% 425 597 19% 40% 41 63 Total room load 2673 2101 258 221 Air required(cfm) 92 921 9 10 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Dec-0315:32:15 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 6 '� E:\Documnets\Wrightsoft HVAC\LOWER RESIDENCE.rup Calc=MJ8 Front Door faces: S IL : W I Nyl l Right-J®Worksheet Job: Entire House Date: Dec 03,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name HALL AHU CLST 2 Exposed wall 7.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 82.5 ft 3.0 x 4.0 ft 5 Room area 82.5 ft2 12.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AB-0fcs 0.183 n 5.12 3.18 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 13.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 13.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 9.50 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.650 n 18.20 9.50 0 0 0 0 0 0 0 0 13AB-Ofcs 0.183 e 5.12 3.18 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 28.23 0 0 0 0 0 0 0 0 2 glazina,clr low-e 0.650 a 18.20 18.64 0 0 0 0 0 0 0 0 W 13A zing, 0.183 s 5.20 3.99 0 0 0 0 0 0 0 0 I�; CGCII 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 VI✓ 13A zing, 0.183 w 5.20 3.97 57 57 290 180 0 0 0 0 I;; GCGII 2 glazing,clr low-e 0.650 w 18.20 20.97 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 w 18.20 18.64 0 0 0 0 0 0 0 0 2 glazinq,clr low-e 0.650 w 18.20 18.64 0 0 0 0 0 0 0 0 Cr 16X19-0md 0.408 1.59 1.37 83 83 131 113 12 12 19 16 F 22A-tl)h 1.358 38.02 0.00 3 0 10 0 0 0 0 0 6 c)AED excursion -4 0 Envelope loss/gain 431 289 19 16 12 a) Infiltration 77 22 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 508 311 19 16 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -508 -311 -19 -16 14 Subtotal 0 0 0 0 15 Duct loads 19% 40% 0 0 19% 40% 0 0 Total room load 0 0 0 0 Air required(cfm) 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Dec-0315:32:15 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 7 '� E:\Documnets\Wrightsoft HVAC\LOWER RESIDENCE.rup Calc=MJ8 Front Door faces: S IL : W I Nyl l Right-J®Worksheet Job: Entire House Date: Dec 03,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name MASTER BEDROOM M WIC 2 Exposed wall 32.0 ft 23.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 268.0 ft 1.0 x 104.0 ft 5 Room area 268.0 ft2 104.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AB-0fcs 0.183 n 5.12 3.18 144 88 452 281 56 56 287 178 2 glazing,clr low-e 0.650 n 18.20 13.26 15 0 273 199 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 13.26 41 0 743 541 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 9.50 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.650 n 18.20 9.50 0 0 0 0 0 0 0 0 13AB-Ofcs 0.183 e 5.12 3.18 112 104 533 331 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 a 18.20 28.23 8 0 146 226 0 0 0 0 2 glazina,clr low-e 0.650 a 18.20 18.64 0 0 0 0 0 0 0 0 W 13A zing, 0.183 s 5.20 3.99 0 0 0 0 0 0 0 0 I�; CGCII 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 VI✓ 13AB-Ofcs 0.183 w 5.12 3.18 0 0 0 0 128 128 657 408 I;; GCGII 2 glazing,clr low-e 0.650 w 18.20 20.97 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 w 18.20 18.64 0 0 0 0 0 0 0 0 2 glazinq,clr low-e 0.650 w 18.20 18.64 0 0 0 0 0 0 0 0 Cr 16X19-0md 0.408 1.59 1.37 268 268 425 367 104 104 165 142 F 22A-tl)h 1.358 38.02 0.00 0 0 0 0 7 2 62 0 6 c)AED excursion -31 -11 Envelope loss/gain 2571 1913 1171 718 12 a) Infiltration 350 99 252 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 300 0 Subtotal(lines 6 to 13) 2921 2312 1423 789 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 106 68 95 58 14 Subtotal 3027 2380 1518 848 15 Duct loads 19% 40% 572 945 19% 40% 287 337 Total room load 3600 3325 1805 1184 Air required(cfm) 1241 146 62 52 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Dec-0315:32:15 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 8 '� E:\Documnets\Wrightsoft HVAC\LOWER RESIDENCE.rup Calc=MJ8 Front Door faces: S IL : W I Nyl l Right-J®Worksheet Job: Entire House Date: Dec 03,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BATH 2 2 Exposed wall 10.0 ft 3 Room height 8.0 ft heat/cool 4 Room dimensions 12.0 x 10.0 ft 5 Room area 120.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AB-OFcs 0.183 n 5.12 3.18 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 13.26 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 13.26 0 0 0 0 2 glazing,clr low-e 0.650 n 18.20 9.50 0 0 0 0 11 2 glazing,clr low-e 0.650 n 18.20 9.50 0 0 0 0 13AB-Ofcs 0.183 e 5.12 3.18 80 80 410 255 2 glazing,clr low-e 0.650 e 18.20 33.77 0 0 0 0 2 glazing,clr low-e 0.650 e 18.20 33.77 0 0 0 0 2 glazing,clr low-e 0.650 e 18.20 33.77 0 0 0 0 2 glazing,clr low-e 0.650 e 18.20 33.77 0 0 0 0 2 glazing,clr low-e 0.650 e 18.20 28.23 0 0 0 0 2 glazinq,clr low-e 0.650 e 18.20 18.64 0 0 0 0 W 13AB-Ofcs 0.183 s 5.12 3.18 0 0 0 0 �--G 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 i� CCI 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 2 glazing,clr low-e 0.650 s 18.20 14.99 0 0 0 0 2 glazing, 0.650 w 5.20 3.97 0 0 0 0 2 glazing,clr low-e 0.650 w 18.20 20.97 0 0 0 0 2 glazing,clr low-e 0.650 w 18.20 18.64 0 0 0 0 2 glazinq,clr low-e 0.650 w 18.20 18.64 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 120 120 190 164 F 22A-tr)h 1.358 38.02 0.00 0 0 0 0 6 c)AED excursion -6 Envelope loss/gain 600 413 12 a) Infiltration 109 31 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 710 444 Less external load 0 0 Less transfer 0 0 Redistribution 151 94 14 Subtotal 860 538 15 Duct loads 19% 40% 163 214 Total room load 1023 752 Air required(cfm) 1 1 351 33 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Dec-0315:32:15 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 9 '� E:\Documnets\Wrightsoft HVAC\LOWER RESIDENCE.rup Calc=MJ8 Front Door faces: S L-7 wrignI Duct System Summary Job: Date: Dec 03,2021 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For: LOWER RESIDENCE LOT 1069 NETTLES ISLAND, JENSEN BEACH, FL Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply/ return available pressure 0.500/ 0.500 in H2O 0.500/0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 980 cfm 980 cfm Total effective length (TEL) 172 ft Supply Branch DetailTable Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln (ft) Ln (ft) Trunk BATH h 1501 52 24 1.000 5.0 Ox0 VIFx 15.1 150.0 st5 BATH 2 h 1023 35 33 1.000 5.0 Ox 0 VIFx 15.8 115.0 st3 BEDROOM 2 h 2673 92 92 1.000 7.0 Ox0 VIFx 15.8 115.0 st3 FOYER c 2304 69 101 1.000 7.0 Ox0 VIFx 22.0 150.0 st4 KITCHEN c 3358 37 147 1.000 8.0 Ox0 VIFx 13.4 150.0 st5 LIVING/DINING RM h 7677 265 169 1.000 8.0 Ox0 VIFx 13.4 150.0 st5 M WIC h 1805 62 52 1.000 6.0 Ox 0 VIFx 8.5 115.0 st 1 MASTER BEDROOM c 3325 124 146 1.000 8.0 Ox0 VIFx 7.9 115.0 st1 OFFICE h 2880 99 94 1.000 7.0 Ox0 VIFx 19.3 150.0 st4 STAIRS UP h 3335 115 97 1.000 7.0 Ox0 VIFx 22.8 115.0 st3 W/DAREA c 221 9 10 1.000 4.0 Ox0 VIFx 14.9 115.0 st3 WIC 2 h 557 19 16 1.000 4.0 Ox0 VIFx 18.1 115.0 st3 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 522 535 1.000 682 12.0 0 x 0 VinlFlx st1 Peak AVF 187 197 1.000 566 8.0 0 x 0 VinlFlx st3 Peak AVF 271 247 1.000 613 9.0 0 x 0 VinlFlx st4 Peak AVF 168 195 1.000 557 8.0 0 x 0 VinlFlx st2 st5 Peak AVF 354 341 1.000 649 10.0 0 x 0 VinlFlx st2 - --30ft- 1•F wrigl 2021-Dec-03 15:32:18 Right-SuiteO Universal 2021 21.0.02 RSU08101 Page 1 �L u E:\Documnets\Wrightsoft HVAC\LOWER RESIDENCE.rup Calc=MJ8 Front Door faces: S TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox0 980 980 0 0 0 0 Ox 0 VIFx — --311ft--'1•F wrigl 2021-Dec-03 15:32:18 Right-SuiteO Universal 2021 21.0.02 RSU08101 Page 2 �L u E:\Documnets\Wrightsoft HVAC\LOWER RESIDENCE.rup Calc=MJ8 Front Door faces: S This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.