HomeMy WebLinkAboutREVISED ENERGY EFFICIENCY CODE FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: LOWER RESIDENCE Builder Name:
Street: LOT 1069 NETTLES ISLAND Permit Office: ST LUCIE COUNTY
City,State,Zip: JENSEN BEACH,FL, Permit Number:
Owner: Jurisdiction: ST LUCIE COUNTY
Design Location: FL,Fort Pierce County. St.Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 10. Wall Types(1890.0 sgft.) Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Polystyrene Bead Aggr6R=5.0 1890.00 ft2
b.NIA R= ft2
3. Number of units,if multiple family 1 G.NIA R= ft2
4, Number of Bedrooms 2 d.N/A R= ft2
11.Ceiling Types (1672.0 sgft.) Insulation Area
5. Is this a worst case? No a.Roof Deck(Unvented) R=19.0 1672.00 ft2
6. Conditioned floor area above grade(ft2) 1672 b.NIA R= ft2
Conditioned floor area below grade(ft2) 0 c.NIA R= ft2
7. Windows(299.2 sgft.) Description Area 12.Ducts R ft2
a.Sup:Attic,Ret:Attic,AK AHU CLST 6 140
a. U-Factor: Sgl,U=0.65 299.17 ft2
SHGC: SHGC=0.25
b. U-Factor: NIA ft2 13.Cooling systems kStulhr Efficiency
SHGC: a.Central Unit 29.4 SEER:16.00
c. U-Factor: NIA ft2
SHGC:
Area Weighted Average Overhang Depth: 3.367 ft. 14.Heating systems kl3tulhr Efficiency
Area Weighted Average SHGC: 0.25p a Electric Strip Heat 27,0 COP:1.00
8, Skylights Area
c. U-Factor:(AVG) N!A ft2 15.Hot water systems
SHGC(AVG): NIA a.Electric Tankless Cap: 1 gallons
9. Floor Types (1672.0 sgft.) Insulation Area EF:0.990
a.Raised Floor R-30.0 884,00 ft2 b. Conservation features
b.Slab-On-Grade Edge Insulation R=0.0 788.00 ft2 None
c.NIA R= ft2 16.Credits None
Glass/Floor Area: 0.179 Total Proposed Modified Loads: 52.71 P p QS
Total Baseline Loads: 61.55 r1>`7ti7
I hereby certify that the plans and specifications covered by Review of the plans and t 1E S7,g�,
this calculation are in compliance with the Florida Energy specifications covered by this ��0
Code. calculation indicates compliance '��,
C�� with the Florida Energy Code_
PREPARED BY: Before construction is completed o
DATE: 1-20-90 this building will be inspected for
compliance with Section 553.908 °
hereby certify that this building, as designed, is in compliance Florida Statutes. ,
with the Florida Energy bode' W�`
OWNERIAGENT: f 'f � Y BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402A.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(111402.4.1.2).
- Proposed On of 0.080 exceeds the performance method default limit of 0.08 and therefore does not require duct testing. R405
.2.3
1/20/2022 1:09 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: LOWER RESIDENCE Bedrooms: 2 Address Type: Street Address
Building Type: User Conditioned Area: 1672 Lot#
Owner Name: Total Stories: 2 Block/Subdivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Rotate Angle: 0 Street: LOT 1069 NETTLES IS
Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St,Lucie
Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City,State,Zip: JENSEN BEACH,
Family Type: Detached
FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
/ Design Temp Int Design Temp Heating Design Daily Temp
1/ Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 1672 13376
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 LIVING/DINING RIM 297 2376 No 0 1 Yes Yes Yes
2 KITCHEN 120 960 Yes 0 1 Yes Yes Yes
3 OFFICE 132 1056 No 0 1 Yes Yes Yes
4 ENTRY 104 832 No 0 1 No Yes Yes
5 BATH 65 520 No 0 1 Yes Yes Yes
6 STAIR STORAGE 16 128 No 0 1 Yes Yes Yes
7 FOYER 54 432 No 0 1 Yes Yes Yes
8 STAIRS UP 57 456 No 0 1 Yes Yes Yes
9 WIC 2 42 336 No 0 1 Yes Yes Yes
10 BEDROOM 2 132 1056 No 0 1 1 Yes Yes Yes
11 WID AREA 67 536 No 0 1 No Yes Yes
12 HALL 83 664 No 0 1 Yes Yes Yes
13 AHU CLST 12 96 No 0 1 No Yes Yes
14 MASTER BEDROO 268 2144 No 0 1 1 Yes Yes Yes
15 M WIC 104 832 No 0 1 Yes Yes Yes
16 BATH 2 119 952 No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulation LIVINGIDINING R 49 ft 297 ft2 ---- 1 0 0
2 Slab-On-Grade Edge Insulation KITCHEN loft 120 ft2 --_- 1 0 0
1/20/2022 1-09 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
3 Slab-On-Grade Edge Insulation OFFICE 23 ft 132 ft2 ____ 1 0 0
4 Slab-On-Grade Edge Insulation ENTRY 1 ft 104 ftz _ _ 1 0 0
5 Slab-On-Grade Edge Insulation BATH 10 ft 65 ft2 ____ 1 0 0
6Slab-On-Grade Edge Insulation STAIR STORAGE 4 ft 16 ft2 1 0 0
7 Slab-On-Grade Edge Insulation FOYER 14 ft 54 ft' ___ 1 0 0
8Raised Floor STAIRS UP ____ ____ 57 ft2 30 1 0 0
9 Raised Floor WIC 2 ____ ____ 42 W 30 1 0 0
IORaised Floor BEDROOM 2 ____ ___ 132 ft2 30 1 0 0
11Raised Floor WID AREA ____ 67 ft2 30 1 0 0
12Raised Floor HALL ____ ____ 83 ft2 30 1 0 0
13Raised Floor AHU CLST ____ 12 ft2 30 1 0 0
14Raised Floor MASTER BEDRO 268 ft2 30 1 0 0
15Raised Floor M WIG ____ ____ 104 ft2 30 1 0 0
16Raised Floor BATH 2 ____ ___ 119 ft2 30 1 0 0
ROOF
/ Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
1/ # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Hip Metal 1811 ft2 0 ft2 Light N 0A No 0.9 No 19 22.62
/ ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic LInvented 0 1672 W N N
1/20/2022 1:09 PM FnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Unvented) LIVINGIDINING R 0 Blown 297 ft2 0.1 Wood
2 Under Attic(Unvented) KITCHEN 0 Blown 120 ft2 0.1 Wood
3 Under Attic(Unvented) OFFICE 0 Blown 132 ft2 0.1 Wood
4 Under Attic(Unvented) ENTRY 0 Blown 104 ft2 0.1 Wood
5 Under Attic(Unvented) BATH 0 Blown 65 ft2 0.1 Wood
6 Under Attic(Unvented) STAIR STORAGE 0 Blown 16 ft2 0.1 Wood
7 Under Attic(Unvented) FOYER 0 Blown 54ft2 0.1 Wood
8 Under Attic(Unvented) STAIRS UP 0 Blown 57ft2 0.1 Wood
9 Under Attic(U nvented) WIC 0 Blown 42ft2 0.1 Wood
10 Under Attic(Unvented) BEDROOM 2 0 Blown 132 ft2 0.1 Wood
11 Under Attic(U nvented) WID AREA 0 Blown 67ft2 0.1 Wood
12 Under Attic(Unvented) HALL 0 Blown 83 ft2 0.1 Wood
13 Under Attic(Unvented) AHU CLST 0 Blown 12 ft2 0.1 Wood
14 Under Attic(Unvented) MASTER BEDRO 0 Blown 268 ft2 0.1 Wood
15 Under Attic(Unvented) M WIC 0 Blown 104 ft2 0.1 Wood
16 Under Attic(Unvented) BATH 2 0 Blown 119 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
0
1 N Exterior Concrete Bieck-PolystybWtNG/DININ 5 25 0 8 0 200.0 ft2 0 0 0.1 0
2 E Exterior Concrete Block-PolystydVtNGIDININ 5 11 0 8 0 88.0 ft2 0 0 0.1 0
3 W Exterior Concrete Block-Polystyt VtNGIDININ 5 13 0 8 0 104.0 ft2 0 0 0.1 0
4 E Exterior Concrete Block-PolystyreKkTCH EN 5 10 0 8 0 80.0 ft2 0 0 0.1 0
_ 5 E Exterior Concrete Block-PolystyreridFFICE 5 11 0 8 0 88.0 ft2 0 0 0.1 0
6 S Exterior Concrete Block-PolystyrerOFFICE 5 12 0 8 0 96.0 ft' 0 0 0.1 0
7 W Exterior Concrete Block-Polystyrend3ATH 5 10 1 8 0 80.7 ft2 0 0 0.1 0
8 W Exterior Concrete Block-Polysty&TiAIR STOR 5 4 0 8 0 32.0 ft2 0 0 0.1 0
9 E Exterior Concrete Block-PolystyrenEOYER 5 8 0 8 0 64.0 ft2 0 0 0.1 0
10 S Exterior Concrete Block-PolystyrenEOYER 5 6 0 8 0 48.0 ft2 0 0 0.1 0
11 S Exterior Concrete Block-Polystyr8TsAIRS UP 5 4 0 8 0 32.0 ft2 0 0 0.1 0
12 W Exterior Concrete Block-Polystyr&aAIRS UP 5 13 0 8 0 104.0 ft2 0 0 0.1 0
13 S Exterior Concrete Block-PolystyrenAN IC 2 5 7 0 8 0 56.0 ft2 0 0 0.1 0
14 E Exterior Concrete Block-PolystyftfiPROOM 2 5 12 0 8 0 96.0 ft2 0 0 0.1 0
15 S Exterior Concrete Block-Polystyi615ROOM 2 5 11 0 8 0 88.0 ft2 0 0 0.1 0
16 W Exterior Concrete Block-PolystyrentHALL 5 7 1 8 0 56.7 ft2 0 0 0.1 0
17 N Exterior Concrete Block-PolystyhWETER BE 5 18 0 8 0 144.0 W 0 0 0.1 0
18 E Exterior Concrete Block-Polystyt&ETER BE 5 14 0 8 0 112.0 ft2 0 0 0.1 0
19 N Exterior Concrete Block-Polystyren6/l WIC 5 7 0 8 0 56.0 ft2 0 0 0.1 0
20 W Exterior Concrete Block-Polystyren6A WIC 5 16 0 8 0 128.0 ft2 0 0 0.1 0
21 E Exterior Concrete Block-PolystyrenBATH 2 5 10 0 8 0 80.0 ft2 0 0 0.1 0
22 W Exterior Concrete Block-PolystyreneHALL 5 7 1 8 0 56.7 ft2 0 0 0.1 0
1/20/2022 1:09 PM EnergyGaugeO USA 7.0.00-RaRes2020 FBC 7th Edition(2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N 1 Metal Low-E Single Yes 0.65 0.25 Y 45.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 1
2 N 1 Metal Low-E Single Yes 0.65 0.25 Y 60.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 1
3 E 2 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 1 ft 0 in 1 ft 4 in Drapeslblinds Exterior 1
4 W 3 Metal Low-E Single Yes 0.65 0.25 Y 19.2 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 1
5 E 5 Metal Low-E Single Yes 0.65 0.25 Y 12.0 ft2 1 ft 0 in 1 ft 4 in None None
6 S 6 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 10 ft 0 in 1 ft 4 in None None
7 E 9 Metal Low-E Single Yes 0.65 0.25 Y 6.0 ft2 10 ft 0 in 1 ft 4 in None None
8 E 9 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 10 ft 0 in 1 ft 4 in None None
9 S 10 Metal Law-E Single Yes 0.65 0.25 Y 6.0 ft2 1 ft 0 in 1 ft 4 in None None
10 W 12 Metal Low-E Single Yes 0.65 0.25 Y 12.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5
11 E 14 Metal Law-E Single Yes 0.65 0.25 Y 8.0 ft2 1 ft 0 in 1 ft 4 in None None
12 S 15 Metal Low-E Single Yes 0.65 0.25 Y 12.0 ft2 1 ft 0 in 1 ft 4 in None None
13 N 17 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 7 ft 0 in 1 ft 4 in Drapes/blinds None
14 N 17 Metal Low-E Single Yes 0.65 0.25 Y 41.0 ft2 7 ft 0 in 1 ft 4 in Drapes/blinds None
15 E 18 Metal Low-E Single Yes 0.65 0.25 Y 8.0 ft2 1 ft 0 in 1 ft 4 in Drapesfblinds None
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50) .000254 1114.7 61.15 114.81 .1191 5
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Strip Heat/ None COP:1 27 kBtulhr 1 sys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Single SEER:16 29.4 kBtulhr 882 cfm 0.8 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric Tankiess STAIR STORAGE9 1 gal 55.1 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
1/20/2022 1:09 PM EnergyGaugeS USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
DUCTS
---supply---- ----Return---- Air CFM 25 CFM25 HVAC#
v # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 140 ft2 Attic 14 ft2 Proposed Qn AHU CLST ---cfm 133.E cfm 0.06 0.50 1 1
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling .tan Feb [[ ]]Mar Apr [ May Jun Jul Auge Oct Nov r Dec
Ventin 7C Jan Feb [X]Mar f Apr [ May Jun Jul 4�Au �Sep �Oct �Nov [X]Dec
Venting Jan Feb [[XX]]Mar [X]Apr [ May Jun Jul ( Aug Se Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(W D) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 Be 80
PM Be 80 80 80 78 78 78 78 78 78 78 78
Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 6B 68 68 68 68 68 68 68 68 68 68 68
Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(B Ibslsq.ft. 0 ft2 0 ft 0.3 DINING RM
Default(B Ibslsq.ft. ft2 ft 0.3 BATH 2
Defaull(8lbs/sq.ft. ft2 ft 0.3 BEDROOM 2
Default(B lbslsq.ft. ft2 ft 0.3 CLST 2
Default(8 lbslsq.ft. ft2 ft 0.3 HALL
Default(B lbs/sq.ft. ft2 ft 0.3 LIVING RM
Default(B Ibslsq.ft. ft2 ft 0 3 KITCHEN
Default(8 Ibslsq.ft. ft2 ft 0.3 M BATH
Default(8 Ibslsq.ft. ft2 ft 0.3 M WIC
Default(8 Ibslsq.ft. ft2 ft 0.3 MASTER BEDROO
Default(8 Ibsls .ft. ft2 ft 0.3 FOYER
1/20/2022 1:09 PM EnergyGaugeO USA 7.0.00-RaRes2020 FBC Ah Edition(2020) Compliant Software Page 6 of 6
2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
a
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: LOWER RESIDENCE Builder Name:
Street: LOT 1069 NETTLES ISLAND Permit Office: ST LUC1E COUNTY
City,State,Zip: JENSEN BEACH,FL, Permit Number:
ca
Owner: Jurisdiction: ST LUCIE COUNTY W
z
Design Location: FL,Fort Pierce
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit
Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the tap of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a
Knee walls shall be sealed. material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows,skylights The space between window/door jambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to
(including maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation shall
and cantilevered floors) be permitted to be in contact with the top side of
sheathing,or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation,insulation
Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls.
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building
be sealed to the finished surface. thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an
plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring,
Showerltub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tuhs shall be
on exterior wall tubs shall separate them from the showers and tubs. insulated.
Electrical/phone box on The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply and return register boots that penetrate building thermal
envelope shall be sealed to the sub-floor,wall covering or ceiling
Concealed W hen required to be sealed,concealed fire sprinklers shall only be sealed
sprinklers in a manner that is recommended by the manufacturer.Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a.In addition,inspection of log walls shall be in accordance with the provisions of[CC-400.
1/20/2022 1:10 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 86
The lower the EnergyPerformance Index, the more efficient the home.
LOT 1069 NETTLES ISLAND, JENSEN BEACH, FL,
1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Polystyrene Bead Aggrda=5.0 1890.00 ft2
b.N/A R= ft2
3. Number of units,if multiple family 1 c.NIA R= ft2
4. Number of Bedrooms 2 d.NIA R= f?
11.Ceiling Type and insulation level Insulation Area
5. Is this a worst case? No a.Roof Deck(Unvented) R=19.0 1672.00 ft2
6. Conditioned floor area(ft2) 1672 b.N/A R= ft2
7. Windows- Description Area c.NIA R= ft2
a. U-Factor: Sgl,U=0.65 299.17 ft2 12.Ducts,location&insulation level R ft2
a.Sup:Attic,Ret:Attic,AH:AHU CLST 6 140
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
SHGC: 13.Cooling systems kBtulhr Efficiency
c. U-Factor. NIA ft2 a.Central Unit 29.4 SEER:16.00
SHGC:
d. U-Factor: NIA ft2 14.Heating systems kBtulhr Efficiency
,SHGC: a.Electric Strip Heat 27.0 COP:1.00
Area Weighted Average Overhang Depth: 3.357 ft.
Area Weighted Average SHGC: 0.250
8. Skylights Description Area 15.Hot water systems Cap:1 gallons
a. U-Factor(AVG): NIA ft2 a.Electric EF:0.99
SHGC(AVG): NIA
b. Conservation features
9. Floor Types Insulation Area None
a.Raised Floor R=30.0 884.00 ft2 Credits(Performance method) None
b.Slab-On-Grade Edge Insulation R=0.0 788.00 ft2
c.NIA R= ft2
1 certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed �v`
based on installed Code compliant features.
r �
Builder Signature: ;<^ 1� Date: :
Address of New Howie: City/F Zip: nor
vvF+
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/20/2022 1:09 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1