HomeMy WebLinkAboutSECTION & DETAILSGONG. OR MASONRY
2x4 P.T. BUCK SET IN
SEALANT FASTEN
W/ I/4" DIA. x 2-5/4" MI
TAPCON5 4" FROM
000 � • o CORNERS 412" 0/0 MAX
° o DOOR TRIM
DOORFRAME
FASTEN TO BUCK W/
(2) #10 GALV. x 2-1/2"
5GREW5 0 2'-0" 0/0
DOOR TRIM
PERIMETER SEALANT
STUCCO FINISH
HEAD/JAMB DETAIL (DOOR)
STUCCO FINISH
PERIMETER SEALANT
GONG. OR MASONRY
Ixb P.T. BUCK SET IN
SEALANT AND NAILED
W/1-1/2" CASE HARDENED
Q° COIL NAILS AT 12" O/C.
° 000 ° • ° MAX.
DRYWALL BOARD
CAULKING
DOOR FRAME FASTEN
THRU BUCK W/ (2) 1/4" T.G
x 1-5/4" MIN EMBED
5"/13" O/C
JAMB/HEAD DETAIL (S.O.D.)
'700R THRESHOLD SET
N BED OF CAULK 8
=A5TENED TO SILL W/
'a x 1 1/2" 5CREW5
0 18" 0/C
'ERIMETER SEALANT
'LOOR COVERING
:ONO. FLOOR SLAB
'ERIMETER SEALANT
.iTUGGO FIN15H
SILL DETAIL (DOOR)
DOOR FRAME FASTEN
TO BUCK W/(2) 3/I6"x
2-1/2" TAPGON
5CREW5 ® 2'-0" O/C
FLOOR COVERING I
o ° O O
.00° °•
GROUT BED
CONCRETE SLAB
SILL DF-TAIL
ALUMINUM FRAME
SECURE FRAME TO SILL
WITH SILICONE
CAULKING
o Oo• ll Q° o O Qo
0
PRECAST OR POURED
SILL W/ 1 #5 BAR
PERIMETER SEALANT
SILL DETAIL (WINDOW)
PRE -ENO TRUSSES
\_ALL EXTERIOR GEILINO MATERIAL
TO BE HY-RIB LATHE AND STUCCO
FASTENERS AT 24" O.G., EITHER
-3/4" MIN EMBEDMENT ROOFING
NAILS WITH /&" SHANK AND 3/8"
HEADS OR STAPLES WITH 1-3/4"
MIN EMBEDMENT LEG5 $ 1/Ib" (Ib
GAGE)
EXT. PORCH CLO OET. #1
EXTERIOR
GMU WALL
WATERPROOF I NO
COATING ON
WINDOW SILL,
JAM55 AND HEAD,
SET P.T. WOOD BUCK OVER
APPLY AROUND
O GMU WATERPROOFING IN
CORNER AND
URETHANE SEALANT, FASTEN
EXTEND 8" ALL
PER PRODUCT APPROVALS.
AROUND THE FACE
OF THE WALL.
O3 APPLY LIQUID WATERPROOFING
SEAL EDGE
MEMBRANE OVER THE TOP AND
OF P.T. WOOD
EXTERIOR FACE OF BUCK AND SILL.
BUCK TO
MASONRY
NUMBERS REPRESENT
INSTALLATION SEQUENCE
0
ALL EXTERIOR WALL
INSTALL WINDOW OR DOOR, FASTEN PER PRODUCT
FENESTRATION FLASHING TO
APPROVAL AND SEAL WINDOW OR DOOR FRAME TO
MEET FBG R703.4
P.T. WOOD BUCK AND MASONRY
CMU OPENING WATER
PROOFING
N.T.S.
(2) #/0 5.M5. TOP f BOTTOM
® EACH STUD
FINISHED CEILING - SEE
OTYP. WALL SECTION
CONT. 25 GAUGE METAL TRACKS
TOP $ BOTTOM W/ (1) #10 5M5 Is 24" O/C
2X4 57UD5 ® 16" 0/G
1/2" TYPE 60P5UM WALLBOARD
O4 APPLIED VERTICALLY $ ATTACHED W
I " LONG BUGLE HEAD 5GREW5
TO EACH 510E ® 12" O/G
GONT. 25 GAUGE METAL TRACKS
TOP $ BOTTOM W/P.T. 2X4 BOT PL.
GONG. FLOOR SLAB
1/4" 3-1/2" TAPGON; a 24" O.G. OR
HILT/ PINS .145" DIA x I" L6.
® I6" O/G W/ I " WA5HER5
TYPICAL INTERIOR PARTITION
SCALE: 3/4" = 1'-0"
(2) #/0 5.M.5. TOP d BOTTOM
® EACH 5TUO
FINISHED CEILING - SEE
TYP. WALL SECTION
Ix4 BLOCKING IS
CABINET LOCATIONS.
FASTEN EA. END TO
STUDS W/ (2) #10
5.M.5. EA. END
2X4 STUD; ® 16" O/G
1/2" TYPE 6YP5UM WALLBOARD
O APPLIED VERTICALLY $ ATTACHED W/
I " LON6 BUGLE HEAD SGREW5
TO EACH 510E ® 12" 0/G
GONT. 25 GAUGE METAL TRACKS
TOP 8 BOTTOM KIF T. 2X4 BOT PL.
GONG. FLOOR SLAB
1/4" 3-1/2" TAPGON5 ® 24" O.G. OR
HILTI PIN5 .145" DIA x I" L6.
® 16" O/G W/ I" WA5HER5
TYPICAL INTERIOR PARTITION
ALONG CABINETRY BACKING
56ALE: 3/4" = I'-O"
ALUMINUM FRAME, FASTEN
TO STRUCTURE THRU BUCK
W/ 3/16" TAPGON 5CREW5
® 12" 0/0. MIN. 1-1/4" EMBED
PERIMETER SEALANT
STUCCO FIN15H
GONG. OR MA50NRY
Ix4 MIN. P.T. BUCK SET IN
4iCOIL
SEALANT AND NAILED
W/1-1/2" CASE HARDENED
NAILS AT 12" 0/0.
MAX.
DRYWALL BOARD
CAULKING
JAMB DETAIL (WINDOW)
Ix4 MIN. P.T. BUCK SET IN
SEALANT AND NAILED I^U
-I/2" CASE HARDENED GOI
NAILS AT 12" 0/0. MAX.
GONG. OR MASONRY
DRYWALL BOARD
CAULKING
r- ALUMINUM FRAME, FASTEN
TO STRUCTURE THRU BUCK
W/ 3/I6" TAPGON 5CREW5
® 12" 0/0. MIN. 1-1/4" EMBED
ERIMETER SEALANT
STUCCO FINISH
HFEAD DF_TA I L (WINDOW)
T
2x WOOD OR PVC
SPACED TO REJECT
BOTTvrI mr,u.
cn
GUARDRAIL DETAIL - TYP
1/4" THK xb"xIT 5% PLATE WELDED TO TOP LEFT AND
TOP RIGHT SIDES OF 5% ANGLE BOX. SECURE W/(2)5/5"
DIA) W.A. ® 8" O.G. INTO EACH PLATE. 4" MIN EMBED TYP
THRU-OUT
Q = _ _ _ _ _ - 1/4" THK x2"x2" 5TL ANGLE
I WELDED INTO BOX SHAPE
_= ADD DIAGONALS -I EACH 51DE
° = = = = I PAINT ALL SURFACES FOR RUST
z o _ I PREVENTION
0
-1
w
Up c
pi,-
�v
w O 1/4" THK 5TL CENTER RIB
1/4" THK 5TL BASE BOLTED TO WALL
W/(5/5" DIA) W.A. 12" O.G. (3 MIN) 51ZE OF
BASE TO BE DETERMINED BY G.G.
3 A/C SUPPORT DETAIL
zW
is
�Iu
>Z
p0
2-1
:;rDz
Q v
m o
W
O�
i2lu
m�
Op
m�
pQ
Oz
uw
F -
JQ
Q w
COMP05 TREAD TYP.
ATTACH W/(3/I6-DIA-0"
�p
LONG GALV.) HEX HD
Q
5CREW5. 2 EACH 510E
_
SEE PLAN FOR RISERS
ci,
2x12 STRINGER
�o
�._
P.T.
\-- PT 2xb FASTENED
W/(2) 1/2" DIA. 0"
ATTACH STRINGER
LONG GALV. LAG
W/(2)1/2" DIA-
5CREW5.
THRUBOLT5 INTO PT.
4x4
DO NOT ATTACH TO
' HOUSE DUE TO FLOG
P.T. 4x4 P0575 -
ZONE CHANGE THRU
THESE STAIRS
LUMBER:
LUMBER USED SHALL BE 5P #2 OR
BETTER. ALL LUMBER EXPOSED TO
WEATHER SHALL BE PRESSURE TREATED
OR RATED FOR EXTERIOR USE.
HANDRAIL
SOUTHERN Y. PINE #1 N
TYPICAL (l��
-7/I6'A-7/I6" PICKET
SOUTHERN Y. PINE #1
SPACED TO REJECT �r
A 4" SPHERE m
(Fb = 1750 psi) TYPICAL 1-
#12x3" WV.
5CREW5 TOP &
BTM. TYP.
ACH
NOTE:
ALUMNINUM OR WOOD RAILING
WITH PICKETS SPACED TO
REJECT A 4" DIA SPHERE 8
PER F.B.G. 2020
AT H /IX
x3"T
LOGHE
5G AGH E
USE
SEE
PLAN
P.T. 2x12 STRINGER
—A GRADE— -
R 5TRIN5ER A6AIN5T
STEM WALL USE 3-1/2"
G (1/4") TAPCON5 ® 12" z
0.0.5TAGGERED
1 °
2 SECTION STAIR
A3 SCALE : 1" = 1'-0"
JI ,DOER FOR
WALL MOUNT
HANDRAI L
DETAIL
1= #12x3" WD
m 5CREW5 TOP 8
mErBTM. ® Ib" 0/0
ONLY ALIES TO
CONNECTION TO (WD FRAMING DOES
WOOD FRAMING NOT APPLY TO STAIRS
COVER ALL CONDITIONS
3 GUARDRAIL DETAIL
J�L2, VTR
I LAUNDRY
LO —
�PS\`��
3N
3N I R PTTIG
UP I
2" VTR �3N
J1L
I
I INK ENT
CN 3N I
-A
NN ^
3„ �N N
SNWR
BATH KITCHEN
3
NAILS 0.12 DIA. SHANK 315" DIA
HEAD 1-1/2" LONG ® 6" O.G. 3N
(WHITE)
QUAD PANEL ALUMNINYL
VENTED SOFFIT "AMC"
J-CHANNEL 0,0155 THK ALUM
W/T-NAIL ® 12" O.G. TO CBS 8 IS GA 3
1/4" 55 STAPLE W/ 7/8" MIN EMBEDMT "
® 24" O.G. TO PT 2X2 BATTEN. (MIN)
A3 SOFFIT ATTACHMENT DETAIL �Pc �"
OPTIONAL
To�AER PLUMBING RISER DIAGRAM
Sc� NOT TO SCALE
-I Q
#120" NO. N
SCREWS TOP 8 `r
BTM. TYP.
m �
m !
CONNECTION TO
WOOD 57AIR5
CONCRETE LINTEL
SEE BEAM SCHEDULE
PT 2X2 MIN CONTIN BATTEN
W/3/I6" X 1-1/4" EMBEDMT
TAPCON5 ® 24" O.G.
VTR
z JIL
RE5/D PLR
FLOOD HT.
NOTE:
RISERS ARE MAX 7-3/4"
TREADS ARE 10" MIN. DEPTH
G.G. TO VERIFY ALL FINAL
HEIGHTS IN THE FIELD BEFORE
CONSTRUCTION.
ATTACH 5TRIN5ER TO
NEW PT 4x4 W/(2)I/2"
DIA THRUBOLT5 INTO
PT. 4x4
HAND COMPACT 501L
AROUND P05T - TYP.
I" STANDING MTL SEAM ROOFING OVER PEEL 8
PRE -ENO. WOOD ROOF TRUSS'S
STICK MEMBRANE ROOFING OVER Iq/32" EXT GRADE
024" O/C TYPICAL W/APPROVED
COX PLYWD. FASTEN MTL ROOF PER MANUFAGT.
GALV. 7RU55 ANCHORS SEE 12
SPECIFICATIONS FOR F.B.G. 2020
FRAMING AND BRACING PLAN SEE ELEV
(SEE DIAPHRAGM 50HEDULE FOR NAILING PATTERN
R-Iq 5UGRA5EAL 5PRA
FOAM INSULATION (SEE
RAIN GUTTER - TYP ALL AROUND
ENERGY GALII
(NOT TO EXCEED PROP. LINE)
1
°
PER V3 REG5 I$ CODES.
I/2" (MIN) SAG RESIST. GYPSUM
°
CONTIN. GALV. MTL DRIP OVER 2x6 WOOD
BOARD APPLIED TO UNDERSIDE OF
I°
FASCIA SECURED TO TRU55 ENDS.
TRUSSES
USE VINYL COVERED FASCIA.
I
NAILS 0.12 DIA. SHANK 3/5" DIA HEAD 1-1/2"
FIRE STOP
d
LONG ® b" O.G. (WHITE)
TYPICAL BOND BEAM. REFER TO
J
FLOOR PLAN FOR BEAM SCHEDULE.
CORNER BARS MIN LAP 25"
1
® 1 STORY ZERO 510E OF HOUSE
WALL
SECTI0
A�
l:✓ SCALE: 3/4" =
I'-0"
PRE -ENO. WOOD ROOF TRUSSES
024" O/C TYPICAL W/APPROVED
GALV. TRU55 ANCHORS SEE
FRAMING AND BRACING PLAN
R-Iq 5UCRA5EAL SPRAY FOAM -
INSULATION. (SEE ENERGY GALC)
I" STANDING MTL SEAM ROOFING OVER PEEL 8 STICK
12 MEMBRANE ROOFING OVER I11/52" EXT GRADE COX
Q SEE ELEV. PLYWD. FASTEN MTL ROOF PER MANUFAGT.
SPECIFICATIONS FOR 170 MPH WIND PER F.B.G. R 2020.
(SEE DIAPHRAGM SCHEDULE FOR NAILING PATTERN
5/5" (MIN) GYPSUM BOARD APPLIED)
al
TO UNDERSIDE OF TRUSSES
_
L
FIRE STOP
I
TYPICAL TIE BEAM. REFER TO
4
FLOOR PLAN FOR BEAM SCHEDULE.
k
CORNER BARS MIN LAP 25"
1/2" GYPSUM BOARD OVER
°
Ix2 P.T. FURRING ®I6" 0/G
OVER 5/4" THK FOAM BRD
INSULATION. R-5.0 MIN.
R-q GORE FILL FOAM IN
°I
EXTERIOR BLOCK.
I°
5/4" T$O PLYWOOD FLOOR
GLUED $ NAILED OVER
°I
PRE-ENGINEERED FLOOR TRUSSES
I °
® 5PAGING SUPPLIED BY TRU55
MANUF.
FLOOR TRUSSES
SEE 7RU55 MANUF. DRAWIN65 FOR
DEPTH $ 5PAGING
°
I
•�
SEE FRAMING PLANS FOR
ADDITIONAL STRUCTURAL
DETAIL AND INFORMATION
I°
I°
1/2" SAG RESIST. GYP. BRD. APPLIED TO
UNDERSIDE OF TRUSSES-TYP.
(5/8" THK TYPE 'X' GYPSUM BOARD
'Ell
® GARAGE CLG MIN -WHERE REQUIRED)
a°
FIRE STOP
1/2" GYPSUM BOARD OVER Ix2 P.T
°I
FURRING ® 16" 0/C OVER 5/4" THK
FOAM BRD INSULATION. R-5.0 MIN.
7,111.
APPLIED WOOD BASE
FIN. FLOOR TO BE AT OR
°I
ABOVE FLOOD HEIGHT
STRUCTURAL GONG. SLAB ON .6 MIL VAPOR
°
BARRIOR OVER GLEAN, WELL COMPACTED
TERMITE TREATED GLEAN SAND FILL.
14
revisions
no. date
REV #1 1/20/22
BLDG CMT5
designed PAR
drawn
PAR
checked
55
date
11/23/21
scale
1/4" = 1'-0" U.N.O.
job no.
21-0041 . LOW
QLA
QUANTUM ENGINEERING ASSOCIATES INC.
•
Structural Engineering & Cost Segregation
6415 LAKE WORTH ROAD
SUITE 105
GREENACRES, FLORIDA 33463
W W W.OEASSOCIATES.COIA
.N M.'STgMg'�.
-z'P_• °ENg�•9GC% Digitally signed
�. N. 61 edO
by Shawn
;9 �•, Sy E OF ��
Stambaugh
°
This item has been electronically Date:
-gh, E. sealedby5hawn i,,g 2022.01 .27
Baugh, PE ig thedateshown usinga
Digital Signature.
Printed copies of thisdncumentam 15:47:31-05'00'
nsidered signed and sealed and
the signature must be verified — any
electraniccopies
Shawn M. Stambaugh, PE
FL. LIC. 61850 - C.A. 26210
TOP OF BOND BM.
SEE ELEVATIONS
12" CONTIN. GALV. MTL DRIP OVER 2x6 WOOD FA501A
O.A. SECURED TO TRU55 ENDS.
USE VINYL COVERED FASCIA.
NAILS 0.12 DIA. SHANK 315" DIA HEAD 1-1/2" LONG ® 6"
O.G. (WHITE)
SOFFIT: STUCCO OVER DENSE GLA55 GOLD 5ECURRED
TO TRUSSES
5/6" STUCCO FINISH (2 GOATS) OVER
5" GONG. BLOCK W/ (1) #5 BAR VERT.
UJ
IN GONG. FILLED CELL AS PER PLAN
MIN LAP 30 DIAMETERS
U
Q
Z
W
Z0
Q
Q 0
J
U_
60
LLJ
W Z
2 NO FIN15HEO FLR ELEV
n/
1L..1L�
SEE ELEVATION5
z0
R-Iq IN FLOOR SYSTEMS
� W
5UGREA5EAL SPRAY
FOAM OVER GARAGE
>
0 U
0
J
J
0
CONCRETE BOND BEAM
SEE BEAM 50HEDULE FOR SPECS
project
NOTE:
R702.3.1 MATERIALS. ALL GYPSUM BOARD MATERIALS AND
ACCESSORIES SHALL CONFORM TO A5TM C 36, C 711, C 475,
G 514, G 630, G q31, G qbO, C 1002, G 1047, G 1177, G 1178, G
1278, G 13g5 OR G 13g6 AND SHALL BE INSTALLED IN
ACCORDANCE WITH THE PROVISIONS OF THIS SECTION.
ADHE51VE5 FOR THE INSTALLATION OF GYPSUM BOARD
SHALL CONFORM TO A5TM C 557.
5/8" STUCCO FIN15H (2 GOATS)
OVER 5" GONG. BLOCK W/ (1) #5
BAR VERT. IN GONG. FILLED CELL
AS PER PLAN MIN LAP 30
DIAMETERS
N.A.VO. 6.0 FT.
FIN15HEO FLOOR ® FLOOD
VERIFY W/ 5URVEY INFORM.
Q
I
ALL WALL AND CEILING FINISHES SHALL HAVE A
-III-III-III ° a j°
0�
1
FLAME SPREAD CLASSIFICATION OF NOT GREATER
THEN 200 AS PER FBG R 2020.
°
-III-III-III °
Q
57UCCO STOP A5 REQUIRED
NOTE:
°
III -III -III -III I
9
BY LOCAL BLDG DEPARTMT
INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR
a °
-III-III-III— ° _4J
w0
AND PER F.B.G. 2020 7th
RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN—
— -III
EDIT.
FLOOR -CEILING ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL
=III -III -III —I
w
ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAMEJ
SPREAD INDEX NOT EXCEED 200 WITH AN ACCOMPANYING
501E 0-
GRADE/PAVERS NOTE:
TO
� —
=
—
R702.4.1 GENERAL. CERAMIC TILE SURFACES SHALL BE
SMOKE -DEVELOPED INDEX NOT TO EXCEED 450 WHEN TESTED IN
FOR TEI41 -
=
_ _- INSTALLED IN ACCORDANCE WITH ANSI AI05.1, A105.4,
ACCORDANCE WITH A5TM E 54.
-III-III— — III
—III-III-III-III-III-III=
-III -III -III
-III -III— AI08.5, AI08.6, AIO8.11, AII8.1, AI18.3, AI36.1 AND AI37.1.
NOTE:
-III—
III
-III -III -III
R702.4.2 CEMENT, FIBER -CEMENT AND GLA55 MAT
-III -III
EXPOSED ATTIC INSULATION. ALL EXPOSED INSULATION MATERIALS
-III-III-
1
I'
-I
GYPSUM BACKERS. CEMENT, FIBER -CEMENT OR GLA55
INSTALLED ON ATTIC FLOORS SHALL HAVE A CRITICAL RADIANT
iI 1 I -I I
-I
MAT GYPSUM BACKERS IN COMPLIANCE WITH A5TM G
FLUX NOT LE55 THAN 0.12 WATT PER SQUARE CENTIMETER. EXP05EDIM
1288, G 1325 OR G 1178 AND INSTALLED IN
FOAM PLASTIC INSULATION MATERIALS EXPOSED ON THE
-
ACCORDANCE WITH MANUFACTURERS'
UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL
- -
-1=I I-
RECOMMENDATIONS 514ALL BE USED A5 BAGKER5 FOR
COMPLY WITH SECTION R516
WALL TILE IN TUB AND 5HOWER AREAS AND WALL
PANELS IN SHOWER AREAS.
USE FIBER CEMENT TYPICAL WHERE FIBEROLA55
PREFAB UNITS ARE NOT INSTALLED.
BUILDING WALL SECTION A —A
;GALE: 3/4" = I'-0"
TRU55 COMPANY TO FOLLOW THIS WALL SECTION TO
DE51GN THE OVERHANG CONDITION
J
J
z
_
J
Cn
W
�
U
Z
O
W
—
z
Z
us
z�
L7
0
Lo
Q
W
v
Z
U_
l7
Ul
L11
drawing
SECTIONS &
DETAILS
sheet