Loading...
HomeMy WebLinkAboutSECTION & DETAILSGONG. OR MASONRY 2x4 P.T. BUCK SET IN SEALANT FASTEN W/ I/4" DIA. x 2-5/4" MI TAPCON5 4" FROM 000 � • o CORNERS 412" 0/0 MAX ° o DOOR TRIM DOORFRAME FASTEN TO BUCK W/ (2) #10 GALV. x 2-1/2" 5GREW5 0 2'-0" 0/0 DOOR TRIM PERIMETER SEALANT STUCCO FINISH HEAD/JAMB DETAIL (DOOR) STUCCO FINISH PERIMETER SEALANT GONG. OR MASONRY Ixb P.T. BUCK SET IN SEALANT AND NAILED W/1-1/2" CASE HARDENED Q° COIL NAILS AT 12" O/C. ° 000 ° • ° MAX. DRYWALL BOARD CAULKING DOOR FRAME FASTEN THRU BUCK W/ (2) 1/4" T.G x 1-5/4" MIN EMBED 5"/13" O/C JAMB/HEAD DETAIL (S.O.D.) '700R THRESHOLD SET N BED OF CAULK 8 =A5TENED TO SILL W/ 'a x 1 1/2" 5CREW5 0 18" 0/C 'ERIMETER SEALANT 'LOOR COVERING :ONO. FLOOR SLAB 'ERIMETER SEALANT .iTUGGO FIN15H SILL DETAIL (DOOR) DOOR FRAME FASTEN TO BUCK W/(2) 3/I6"x 2-1/2" TAPGON 5CREW5 ® 2'-0" O/C FLOOR COVERING I o ° O O .00° °• GROUT BED CONCRETE SLAB SILL DF-TAIL ALUMINUM FRAME SECURE FRAME TO SILL WITH SILICONE CAULKING o Oo• ll Q° o O Qo 0 PRECAST OR POURED SILL W/ 1 #5 BAR PERIMETER SEALANT SILL DETAIL (WINDOW) PRE -ENO TRUSSES \_ALL EXTERIOR GEILINO MATERIAL TO BE HY-RIB LATHE AND STUCCO FASTENERS AT 24" O.G., EITHER -3/4" MIN EMBEDMENT ROOFING NAILS WITH /&" SHANK AND 3/8" HEADS OR STAPLES WITH 1-3/4" MIN EMBEDMENT LEG5 $ 1/Ib" (Ib GAGE) EXT. PORCH CLO OET. #1 EXTERIOR GMU WALL WATERPROOF I NO COATING ON WINDOW SILL, JAM55 AND HEAD, SET P.T. WOOD BUCK OVER APPLY AROUND O GMU WATERPROOFING IN CORNER AND URETHANE SEALANT, FASTEN EXTEND 8" ALL PER PRODUCT APPROVALS. AROUND THE FACE OF THE WALL. O3 APPLY LIQUID WATERPROOFING SEAL EDGE MEMBRANE OVER THE TOP AND OF P.T. WOOD EXTERIOR FACE OF BUCK AND SILL. BUCK TO MASONRY NUMBERS REPRESENT INSTALLATION SEQUENCE 0 ALL EXTERIOR WALL INSTALL WINDOW OR DOOR, FASTEN PER PRODUCT FENESTRATION FLASHING TO APPROVAL AND SEAL WINDOW OR DOOR FRAME TO MEET FBG R703.4 P.T. WOOD BUCK AND MASONRY CMU OPENING WATER PROOFING N.T.S. (2) #/0 5.M5. TOP f BOTTOM ® EACH STUD FINISHED CEILING - SEE OTYP. WALL SECTION CONT. 25 GAUGE METAL TRACKS TOP $ BOTTOM W/ (1) #10 5M5 Is 24" O/C 2X4 57UD5 ® 16" 0/G 1/2" TYPE 60P5UM WALLBOARD O4 APPLIED VERTICALLY $ ATTACHED W I " LONG BUGLE HEAD 5GREW5 TO EACH 510E ® 12" O/G GONT. 25 GAUGE METAL TRACKS TOP $ BOTTOM W/P.T. 2X4 BOT PL. GONG. FLOOR SLAB 1/4" 3-1/2" TAPGON; a 24" O.G. OR HILT/ PINS .145" DIA x I" L6. ® I6" O/G W/ I " WA5HER5 TYPICAL INTERIOR PARTITION SCALE: 3/4" = 1'-0" (2) #/0 5.M.5. TOP d BOTTOM ® EACH 5TUO FINISHED CEILING - SEE TYP. WALL SECTION Ix4 BLOCKING IS CABINET LOCATIONS. FASTEN EA. END TO STUDS W/ (2) #10 5.M.5. EA. END 2X4 STUD; ® 16" O/G 1/2" TYPE 6YP5UM WALLBOARD O APPLIED VERTICALLY $ ATTACHED W/ I " LON6 BUGLE HEAD SGREW5 TO EACH 510E ® 12" 0/G GONT. 25 GAUGE METAL TRACKS TOP 8 BOTTOM KIF T. 2X4 BOT PL. GONG. FLOOR SLAB 1/4" 3-1/2" TAPGON5 ® 24" O.G. OR HILTI PIN5 .145" DIA x I" L6. ® 16" O/G W/ I" WA5HER5 TYPICAL INTERIOR PARTITION ALONG CABINETRY BACKING 56ALE: 3/4" = I'-O" ALUMINUM FRAME, FASTEN TO STRUCTURE THRU BUCK W/ 3/16" TAPGON 5CREW5 ® 12" 0/0. MIN. 1-1/4" EMBED PERIMETER SEALANT STUCCO FIN15H GONG. OR MA50NRY Ix4 MIN. P.T. BUCK SET IN 4iCOIL SEALANT AND NAILED W/1-1/2" CASE HARDENED NAILS AT 12" 0/0. MAX. DRYWALL BOARD CAULKING JAMB DETAIL (WINDOW) Ix4 MIN. P.T. BUCK SET IN SEALANT AND NAILED I^U -I/2" CASE HARDENED GOI NAILS AT 12" 0/0. MAX. GONG. OR MASONRY DRYWALL BOARD CAULKING r- ALUMINUM FRAME, FASTEN TO STRUCTURE THRU BUCK W/ 3/I6" TAPGON 5CREW5 ® 12" 0/0. MIN. 1-1/4" EMBED ERIMETER SEALANT STUCCO FINISH HFEAD DF_TA I L (WINDOW) T 2x WOOD OR PVC SPACED TO REJECT BOTTvrI mr,u. cn GUARDRAIL DETAIL - TYP 1/4" THK xb"xIT 5% PLATE WELDED TO TOP LEFT AND TOP RIGHT SIDES OF 5% ANGLE BOX. SECURE W/(2)5/5" DIA) W.A. ® 8" O.G. INTO EACH PLATE. 4" MIN EMBED TYP THRU-OUT Q = _ _ _ _ _ - 1/4" THK x2"x2" 5TL ANGLE I WELDED INTO BOX SHAPE _= ADD DIAGONALS -I EACH 51DE ° = = = = I PAINT ALL SURFACES FOR RUST z o _ I PREVENTION 0 -1 w Up c pi,- �v w O 1/4" THK 5TL CENTER RIB 1/4" THK 5TL BASE BOLTED TO WALL W/(5/5" DIA) W.A. 12" O.G. (3 MIN) 51ZE OF BASE TO BE DETERMINED BY G.G. 3 A/C SUPPORT DETAIL zW is �Iu >Z p0 2-1 :;rDz Q v m o W O� i2lu m� Op m� pQ Oz uw F - JQ Q w COMP05 TREAD TYP. ATTACH W/(3/I6-DIA-0" �p LONG GALV.) HEX HD Q 5CREW5. 2 EACH 510E _ SEE PLAN FOR RISERS ci, 2x12 STRINGER �o �._ P.T. \-- PT 2xb FASTENED W/(2) 1/2" DIA. 0" ATTACH STRINGER LONG GALV. LAG W/(2)1/2" DIA- 5CREW5. THRUBOLT5 INTO PT. 4x4 DO NOT ATTACH TO ' HOUSE DUE TO FLOG P.T. 4x4 P0575 - ZONE CHANGE THRU THESE STAIRS LUMBER: LUMBER USED SHALL BE 5P #2 OR BETTER. ALL LUMBER EXPOSED TO WEATHER SHALL BE PRESSURE TREATED OR RATED FOR EXTERIOR USE. HANDRAIL SOUTHERN Y. PINE #1 N TYPICAL (l�� -7/I6'A-7/I6" PICKET SOUTHERN Y. PINE #1 SPACED TO REJECT �r A 4" SPHERE m (Fb = 1750 psi) TYPICAL 1- #12x3" WV. 5CREW5 TOP & BTM. TYP. ACH NOTE: ALUMNINUM OR WOOD RAILING WITH PICKETS SPACED TO REJECT A 4" DIA SPHERE 8 PER F.B.G. 2020 AT H /IX x3"T LOGHE 5G AGH E USE SEE PLAN P.T. 2x12 STRINGER —A GRADE— - R 5TRIN5ER A6AIN5T STEM WALL USE 3-1/2" G (1/4") TAPCON5 ® 12" z 0.0.5TAGGERED 1 ° 2 SECTION STAIR A3 SCALE : 1" = 1'-0" JI ,DOER FOR WALL MOUNT HANDRAI L DETAIL 1= #12x3" WD m 5CREW5 TOP 8 mErBTM. ® Ib" 0/0 ONLY ALIES TO CONNECTION TO (WD FRAMING DOES WOOD FRAMING NOT APPLY TO STAIRS COVER ALL CONDITIONS 3 GUARDRAIL DETAIL J�L2, VTR I LAUNDRY LO — �PS\`�� 3N 3N I R PTTIG UP I 2" VTR �3N J1L I I INK ENT CN 3N I -A NN ^ 3„ �N N SNWR BATH KITCHEN 3 NAILS 0.12 DIA. SHANK 315" DIA HEAD 1-1/2" LONG ® 6" O.G. 3N (WHITE) QUAD PANEL ALUMNINYL VENTED SOFFIT "AMC" J-CHANNEL 0,0155 THK ALUM W/T-NAIL ® 12" O.G. TO CBS 8 IS GA 3 1/4" 55 STAPLE W/ 7/8" MIN EMBEDMT " ® 24" O.G. TO PT 2X2 BATTEN. (MIN) A3 SOFFIT ATTACHMENT DETAIL �Pc �" OPTIONAL To�AER PLUMBING RISER DIAGRAM Sc� NOT TO SCALE -I Q #120" NO. N SCREWS TOP 8 `r BTM. TYP. m � m ! CONNECTION TO WOOD 57AIR5 CONCRETE LINTEL SEE BEAM SCHEDULE PT 2X2 MIN CONTIN BATTEN W/3/I6" X 1-1/4" EMBEDMT TAPCON5 ® 24" O.G. VTR z JIL RE5/D PLR FLOOD HT. NOTE: RISERS ARE MAX 7-3/4" TREADS ARE 10" MIN. DEPTH G.G. TO VERIFY ALL FINAL HEIGHTS IN THE FIELD BEFORE CONSTRUCTION. ATTACH 5TRIN5ER TO NEW PT 4x4 W/(2)I/2" DIA THRUBOLT5 INTO PT. 4x4 HAND COMPACT 501L AROUND P05T - TYP. I" STANDING MTL SEAM ROOFING OVER PEEL 8 PRE -ENO. WOOD ROOF TRUSS'S STICK MEMBRANE ROOFING OVER Iq/32" EXT GRADE 024" O/C TYPICAL W/APPROVED COX PLYWD. FASTEN MTL ROOF PER MANUFAGT. GALV. 7RU55 ANCHORS SEE 12 SPECIFICATIONS FOR F.B.G. 2020 FRAMING AND BRACING PLAN SEE ELEV (SEE DIAPHRAGM 50HEDULE FOR NAILING PATTERN R-Iq 5UGRA5EAL 5PRA FOAM INSULATION (SEE RAIN GUTTER - TYP ALL AROUND ENERGY GALII (NOT TO EXCEED PROP. LINE) 1 ° PER V3 REG5 I$ CODES. I/2" (MIN) SAG RESIST. GYPSUM ° CONTIN. GALV. MTL DRIP OVER 2x6 WOOD BOARD APPLIED TO UNDERSIDE OF I° FASCIA SECURED TO TRU55 ENDS. TRUSSES USE VINYL COVERED FASCIA. I NAILS 0.12 DIA. SHANK 3/5" DIA HEAD 1-1/2" FIRE STOP d LONG ® b" O.G. (WHITE) TYPICAL BOND BEAM. REFER TO J FLOOR PLAN FOR BEAM SCHEDULE. CORNER BARS MIN LAP 25" 1 ® 1 STORY ZERO 510E OF HOUSE WALL SECTI0 A� l:✓ SCALE: 3/4" = I'-0" PRE -ENO. WOOD ROOF TRUSSES 024" O/C TYPICAL W/APPROVED GALV. TRU55 ANCHORS SEE FRAMING AND BRACING PLAN R-Iq 5UCRA5EAL SPRAY FOAM - INSULATION. (SEE ENERGY GALC) I" STANDING MTL SEAM ROOFING OVER PEEL 8 STICK 12 MEMBRANE ROOFING OVER I11/52" EXT GRADE COX Q SEE ELEV. PLYWD. FASTEN MTL ROOF PER MANUFAGT. SPECIFICATIONS FOR 170 MPH WIND PER F.B.G. R 2020. (SEE DIAPHRAGM SCHEDULE FOR NAILING PATTERN 5/5" (MIN) GYPSUM BOARD APPLIED) al TO UNDERSIDE OF TRUSSES _ L FIRE STOP I TYPICAL TIE BEAM. REFER TO 4 FLOOR PLAN FOR BEAM SCHEDULE. k CORNER BARS MIN LAP 25" 1/2" GYPSUM BOARD OVER ° Ix2 P.T. FURRING ®I6" 0/G OVER 5/4" THK FOAM BRD INSULATION. R-5.0 MIN. R-q GORE FILL FOAM IN °I EXTERIOR BLOCK. I° 5/4" T$O PLYWOOD FLOOR GLUED $ NAILED OVER °I PRE-ENGINEERED FLOOR TRUSSES I ° ® 5PAGING SUPPLIED BY TRU55 MANUF. FLOOR TRUSSES SEE 7RU55 MANUF. DRAWIN65 FOR DEPTH $ 5PAGING ° I •� SEE FRAMING PLANS FOR ADDITIONAL STRUCTURAL DETAIL AND INFORMATION I° I° 1/2" SAG RESIST. GYP. BRD. APPLIED TO UNDERSIDE OF TRUSSES-TYP. (5/8" THK TYPE 'X' GYPSUM BOARD 'Ell ® GARAGE CLG MIN -WHERE REQUIRED) a° FIRE STOP 1/2" GYPSUM BOARD OVER Ix2 P.T °I FURRING ® 16" 0/C OVER 5/4" THK FOAM BRD INSULATION. R-5.0 MIN. 7,111. APPLIED WOOD BASE FIN. FLOOR TO BE AT OR °I ABOVE FLOOD HEIGHT STRUCTURAL GONG. SLAB ON .6 MIL VAPOR ° BARRIOR OVER GLEAN, WELL COMPACTED TERMITE TREATED GLEAN SAND FILL. 14 revisions no. date REV #1 1/20/22 BLDG CMT5 designed PAR drawn PAR checked 55 date 11/23/21 scale 1/4" = 1'-0" U.N.O. job no. 21-0041 . LOW QLA QUANTUM ENGINEERING ASSOCIATES INC. • Structural Engineering & Cost Segregation 6415 LAKE WORTH ROAD SUITE 105 GREENACRES, FLORIDA 33463 W W W.OEASSOCIATES.COIA .N M.'STgMg'�. -z'P_• °ENg�•9GC% Digitally signed �. N. 61 edO by Shawn ;9 �•, Sy E OF �� Stambaugh ° This item has been electronically Date: -gh, E. sealedby5hawn i,,g 2022.01 .27 Baugh, PE ig thedateshown usinga Digital Signature. Printed copies of thisdncumentam 15:47:31-05'00' nsidered signed and sealed and the signature must be verified — any electraniccopies Shawn M. Stambaugh, PE FL. LIC. 61850 - C.A. 26210 TOP OF BOND BM. SEE ELEVATIONS 12" CONTIN. GALV. MTL DRIP OVER 2x6 WOOD FA501A O.A. SECURED TO TRU55 ENDS. USE VINYL COVERED FASCIA. NAILS 0.12 DIA. SHANK 315" DIA HEAD 1-1/2" LONG ® 6" O.G. (WHITE) SOFFIT: STUCCO OVER DENSE GLA55 GOLD 5ECURRED TO TRUSSES 5/6" STUCCO FINISH (2 GOATS) OVER 5" GONG. BLOCK W/ (1) #5 BAR VERT. UJ IN GONG. FILLED CELL AS PER PLAN MIN LAP 30 DIAMETERS U Q Z W Z0 Q Q 0 J U_ 60 LLJ W Z 2 NO FIN15HEO FLR ELEV n/ 1L..1L� SEE ELEVATION5 z0 R-Iq IN FLOOR SYSTEMS � W 5UGREA5EAL SPRAY FOAM OVER GARAGE > 0 U 0 J J 0 CONCRETE BOND BEAM SEE BEAM 50HEDULE FOR SPECS project NOTE: R702.3.1 MATERIALS. ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL CONFORM TO A5TM C 36, C 711, C 475, G 514, G 630, G q31, G qbO, C 1002, G 1047, G 1177, G 1178, G 1278, G 13g5 OR G 13g6 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF THIS SECTION. ADHE51VE5 FOR THE INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO A5TM C 557. 5/8" STUCCO FIN15H (2 GOATS) OVER 5" GONG. BLOCK W/ (1) #5 BAR VERT. IN GONG. FILLED CELL AS PER PLAN MIN LAP 30 DIAMETERS N.A.VO. 6.0 FT. FIN15HEO FLOOR ® FLOOD VERIFY W/ 5URVEY INFORM. Q I ALL WALL AND CEILING FINISHES SHALL HAVE A -III-III-III ° a j° 0� 1 FLAME SPREAD CLASSIFICATION OF NOT GREATER THEN 200 AS PER FBG R 2020. ° -III-III-III ° Q 57UCCO STOP A5 REQUIRED NOTE: ° III -III -III -III I 9 BY LOCAL BLDG DEPARTMT INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR a ° -III-III-III— ° _4J w0 AND PER F.B.G. 2020 7th RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN— — -III EDIT. FLOOR -CEILING ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL =III -III -III —I w ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAMEJ SPREAD INDEX NOT EXCEED 200 WITH AN ACCOMPANYING 501E 0- GRADE/PAVERS NOTE: TO � — = — R702.4.1 GENERAL. CERAMIC TILE SURFACES SHALL BE SMOKE -DEVELOPED INDEX NOT TO EXCEED 450 WHEN TESTED IN FOR TEI41 - = _ _- INSTALLED IN ACCORDANCE WITH ANSI AI05.1, A105.4, ACCORDANCE WITH A5TM E 54. -III-III— — III —III-III-III-III-III-III= -III -III -III -III -III— AI08.5, AI08.6, AIO8.11, AII8.1, AI18.3, AI36.1 AND AI37.1. NOTE: -III— III -III -III -III R702.4.2 CEMENT, FIBER -CEMENT AND GLA55 MAT -III -III EXPOSED ATTIC INSULATION. ALL EXPOSED INSULATION MATERIALS -III-III- 1 I' -I GYPSUM BACKERS. CEMENT, FIBER -CEMENT OR GLA55 INSTALLED ON ATTIC FLOORS SHALL HAVE A CRITICAL RADIANT iI 1 I -I I -I MAT GYPSUM BACKERS IN COMPLIANCE WITH A5TM G FLUX NOT LE55 THAN 0.12 WATT PER SQUARE CENTIMETER. EXP05EDIM 1288, G 1325 OR G 1178 AND INSTALLED IN FOAM PLASTIC INSULATION MATERIALS EXPOSED ON THE - ACCORDANCE WITH MANUFACTURERS' UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL - - -1=I I- RECOMMENDATIONS 514ALL BE USED A5 BAGKER5 FOR COMPLY WITH SECTION R516 WALL TILE IN TUB AND 5HOWER AREAS AND WALL PANELS IN SHOWER AREAS. USE FIBER CEMENT TYPICAL WHERE FIBEROLA55 PREFAB UNITS ARE NOT INSTALLED. BUILDING WALL SECTION A —A ;GALE: 3/4" = I'-0" TRU55 COMPANY TO FOLLOW THIS WALL SECTION TO DE51GN THE OVERHANG CONDITION J J z _ J Cn W � U Z O W — z Z us z� L7 0 Lo Q W v Z U_ l7 Ul L11 drawing SECTIONS & DETAILS sheet A-3