HomeMy WebLinkAboutCOVER SHEETGENERAL NOTES
THESE PLANS WERE PREPARED U51NO THE FLORIDA BUILDING CODE 2020 EDITION\
2. CONSTRUCTION SHALL FOLLOW THE FLORIDA BUILDING CODE AS ADAPTED BY Tri j
COUNTY AND ALL APPLICABLE AMENDMENTS.
3. BUILDER SHALL COORDINATE ALL THE WORK OF ALL TRADES.
4. BUILDER SHALL REVIEW DRAWINGS IN THEIR ENTIRETY BEFORE STARTING WORK. TH
BUILDER SHALL ACCEPT FULL RE5PON5ABILITY FOR ANY ERRORS OR OMISSIONS NOT
REPORTED IMMEDIATELY IN WRITING TO THE ARCHITECT. BACKGHARGE5 WILL NOT B�
ACCEPTED. DO NOT 50ALE DRAWINGS.
5. SUBMIT MINIMUM THREE (5) COPIES OF SHOP DRAWING5 AS REQUIRED BELOW.
6. BUILDER 15 RESPONSIBLE FOR ADEQUATE BRACING OF STRUCTURAL OR
NON-STRUCTURAL MEMBERS DURING CONSTRUCTION.
7. ALL CONSTRUCTION IN BROWARD AND DARE COUNTIES SHALL COMPLY WITH THE
HIGH VELOCITY HURRICANE ZONE (HVHZ) 5ECTION5 OF THE F.B.G. \
SITE PLAN NOTES
R1
I. THE ARCHITECTURAL 51TE PLAN, IF PROVIDED IN THESE DOCUMENTS 15 FOR GENERAL
LOCATION OF THE HOUSE, POOL, DRIVEWAYS AND 51TE FEATURES ONLY. THE G.G. OR
OWNER SHALL PROVIDE A PRELIMINARY LOT FIT PERFORMED BY A LIGENGED
BEAM SCHEDULE NOTES
SURVEYOR AT 50 PEGENT COMPLETION OF PROJECT. THE SURVEYOR IS RESPONSIBLE
FOR VERIFYING BUILDING LOT FIT, LOT COVERAGE, EASEMENT LOCATIONS, SET BACKS,
AND ALL 51TE DIMENSIONS PRIOR TO PERMIT AND CONSTRUCTION. IF ANY CONFLICTS
OCCUR BETWEEN THE ARCHITECTURAL 51TE PLAN AND SURVEYORS LAYOUT THE GENERAL
I. SCHEDULED HOOPS AND STIRRUPS SHALL BE PLACED AT EACH END (E.E.) OF BEAM OR
CONTRACTOR AND ARCHITECT SHALL BE NOTIFIED IN WRITING PRIOR TO PERMITTING
THROUGHOUT (T.0) BEAM AS INDICATED ON BEAM SCHEDULE. STIRRUPS SHALL BE TYPE
AND CONSTRUCTION. NO WORK SHALL BE PERFORMED UNTIL THE GENERAL CONTRACTOR
5-6 AND HOOPS SHALL BE TYPE T-2 TYPICAL CR51 BAR BENDS UNLE55 OTHERWISE
RESOLVES THESE CONFLICTS.
NOTED.
CONCRETE NOTES
2. ALL BEAM (MARK "B") TOP BARS SHALL BE CONTINUOUS UNLE55 OTHERWISE NOTED
3. ALL TIE BEAMS (MARK "TB") REINFORCING SHALL BE CONTINUOUS THROUGH TIE -
I. CONCRETE SHALL CONFORM TO A5TM Cq4/C 14M-15A, SHALL HAVE A MAXIMUM
BEAMS ONLY. ALL SPLICES TO BE A MINIMUM OF 45 BAR DIAMETERS.
WATER/GEMENT RATIO OF 0.65 AND SHALL HAVE 5000 P51 COMPRESSIVE 5TRENGTH IN
25 DAYS ( UNLE55 NOTED OTHERWISE) ALL CONCRETE WORK SHALL BE IN ACCORDANCE
4. BUNDLE ALL STRUCTURAL BEAM TOP BAR5 IN PAIRS OVER 5UPPORT5 WITH TOP BAR5
WITH AGI 50-14 AND TM5 402-2016. ALL CONCRETE MASONRY WORK SHALL BE IN
FROM ADJACENT BEAMS. (UNO).
ACCORDANCE WITH TM5 403-2017.
5. DROP BOTTOM OF TIE BEAMS A5 REQUIRED AT WINDOW 8 DOOR HEADS (25" MAX.)
2. MINIMUM CONCRETE COVER OVER REINFORCING SHALL BE: 5LAB5 ON VAPOR
ADD 245 BOTTOM IF DROP EXCEEDS 5".
BARRIER - 5/4" BEAMS AND COLUMNS - 1 1/2" FORMED CONCRETE BELOW GRADE-2"
UNFORMED CONCRETE BELOW GRADE-3"
6. TIE BEAM SCHEDULE DEPTHS ARE MINIMUM AND MAY BE INCREASED 5" TO FIT BLOCK
WORK.
3. REINFORCING STEEL: GRADE 60 (FY=60.000) A5TM A615/A 615M-150e1.
7. ALL ADDED LOGITUDINAL BEAM REINFORCING SHALL EXTEND b" MINIMUM INTO
4. DETAIL OF CONCRETE REINFORCEMENT SHALL BE IN ACCORDANCE WITH "THE MANUAL
SUPPORT UNLE55 OTHERWISE NOTED.
OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION" AS PUBLISHED
BY THE CONCRETE REINFORCING STEEL INSTITUTE UNLE55 NOTED OTHERWISE.
5. REFER TO CONCRETE NOTES FOR INFORMATION ON CONCRETE AND STEEL
SPECIFICATIONS.
5. ADEQUATE VERTICAL AND HORIZONTAL SHORING SHALL BE PROVIDED TO SAFELY
SUPPORT ALL LOADS DURING CONSTRUCTION.
q. ONE -QUARTER OF MAXIMUM BOTTOM REINFORCING STEEL AREA OF EITHER ADJACENT
BEAM SHALL EXTEND THRU SUPPORT AND LAP WITH A GLA55 "A" TENSION LAP SPLICE
6. DOWEL5 COLUMN AND WALL REINFORCING TO FOOTING WITH SAME 51ZE AND NUMBER
ON EITHER 5IDE OF SUPPORT.
OF DOWELS AS VERTICAL BAR5 ABOVE.
10. MARK "G" IN REINFORCING COLUMN BETWEEN TWO BEAMS INDICATES THAT
7. REINFORCING STEEL SHALL BE LAPPED 45 BAR DIA. MIN. WHERE SPLICED AND SHALL
REINFORCING SHALL BE CONTINUOUS THRU THESE TWO BEAMS.
BE WIRED TOGETHER. PROVIDE CORNER BAR5 SAME 51ZE AND NUMBER AS HORIZ. BEAM
REINFORCING AT EACH FACE. LAP 45 BAR DIA. MIN.
5. PLACING DRAWINGS ON BAR L15T5 SHALL CONFORM TO ACI'S "MANUAL OF STANDARD
PRACTICE FOR DETAILING REINFORCED CONCRETE CONSTRUCTION AS PUBLISHED BY THE
CONCRETE REINFORCING STEEL INSTITUTE UNLE55 NOTED OTHERWISE.
ABBREVIATIONS
ABV
ABOVE
EXT.
EXTERIOR
M.G.
MEDICINE CABINET
5M5
SHEET METAL 50REW5
AFF
ABOVE FINISHED FLOOR
F.B.G.
FLORIDA BUILDING CODE
M.R.H.
MEAN ROOF HEIGHT
5T.
STIRRUPS
AHU
AIR HANDLER UNIT
F.R.
FIRE RATED
M.T.
METAL THRESHOLD
5TL.
STEEL
B.F.
BI FOLD
FIR
FRENCH DOOR
MAX.
MAXIMUM
5W
5WITGH
B.P.
BI PA55
FIN.
FINISHED
MFR.
MANUFACTURER
5.W.O.T.
5HEARWALL OVERTURNING FORGE
BLK.
BLOCK
FL.
FLOOR
MICRO.
MICROWAVE
TEMP.
TEMPERED
BLW.
BELOW
G.T.
GIRDER TRU55
MIN.
MINIMUM
T.B.
THROUGH BOLT
BRG.
BEARING
GA.
GAUGE
M.O.
MASONRY OPENING
T.O.
THROUGH OUT
BTM.
BOTTOM
GALV.
GALVANIZED
MONO.
MONOLITHIC
T.O.B.B.
TOP OF MA50NRY BOND BEAM
GLG.
CEILING
GFI
GROUND FAULT INTERRUPT
MTL.
METAL
T.O.PL.
TOP OF WOOD PLATE
GMU
CONCRETE MA50NRY UNITS
GL.
GLA55
O.H.D.
OVER HEAD DOOR
T.O.T.B.
TOP OF TIE BEAM
COL.
COLUMN
GWB
GYPSUM WALLBOARD
0/0
ON CENTER
TYP.
TYPICAL
GONG.
CONCRETE
GYP. BD.
GYPSUM WALLBOARD
P.L.F.
POUNDS PER LINEAR FOOT
U.N.O.
UNLE55 NOTED OTHERWISE
05MT.
CASEMENT
HOT.
HEIGHT
P.5.F.
POUNDS PER SQUARE FOOT
UL
UNDERWRITERS LABORATORIES
DBL.
DOUBLE
HP5.
HOOP5
P.5.1.
POUNDS PER SQUARE INCH
V.I.F.
VERIFY IN FIELD
DIA.
DIAMETER
HR
HOUR
P.T.
PRE55URE TREATED
W.A.
WEDGE ANCHORS
D15P.
DISPOSAL
H5
HORIZONTAL SLIDING
PART'N.
PARTITION
W/
WITH
DP
DESIGN PRE55URE
HVHZ
HIGH VELOCITY HURRICANE ZONE
PKT.
POCKET
WG
WATER CLOSET
DR.
DOOR
INS.
INSULATION
PLYWD.
PLYWOOD
AD.
WOOD
DW
D15H WA5HER
INT.
INTERIOR
R.O.
ROUGH OPENING
E.E.
EACH END
LO.
LONG
S.G.
50LID GORE
ELEC.
ELECTRICAL
LIN.
LINEN
5.O.D.
5LIDINO GLA55 DOOR
ELEV.
ELEVATION
LT.
LIGHT
5F
SQUARE FOOT
E.5.
EACH SIDE
L.T.
LAUNDRY TUB
5H
SINGLE HUNG
ASONRY NOTES
I. ONGRETE UNITS TO BE ASTM G 10-14. A5TM GRADES NI OR NII. PROVIDE PRECAST
NTEL5 A5 NECESSARY. (f'm = 1500 P51)
2. MORTAR TYPE M PER A5TM G 270-14a.
. CONCRETE FILL
A CELLS LINTEL5 AND BOND BEAMS WHERE SPECIFIED SHALL BE FILLED W/ 5000 P51
EA GRAVEL CONCRETE.
B. THE MIX DESIGN SHALL BE APPROVED BY THE ENGINEER.
ALL CONCRETE SHALL BE OF A FLUID CON515TENCY WITH A SLUMP OF q"-11" MAX., WHICH
M AN5 THAT THE CON515TENCY SHALL BE AS FLUID AS POSSIBLE FOR POURING WITHOUT
5 OREGATION OF THE CONSTITUENT PARTS.
D. THE USE OF ADMIXTURES SHALL NOT BE PERMITTED WITHOUT WRITTEN CONSENT OF THE
EN INEER.
REINFORCING:
RTIGAL:
A A5TM A615/A 615M-15ae1. PER REINFORCING SECTION (GRADE II
B WHEN A FOUNDATION DOWEL DOES NOT LINE UP WITH A VERTICAL GORE, IT SHALL NOT
E SLOPED MORE THAN ONE HORIZONTAL IN SIX VERTICAL ALIGNMENT, EVEN THOUGH IT 15
IN AN ADJACENT CELL TO THE VERTICAL WALL REINFORCING.
VERTICAL REINFORCING STEEL SHALL HAVE A MINIMUM CLEARANCE OF ONE-HALF INCH
OM THE MASONRY.
D VERTICAL REINFORCING SHALL BE AS LOCATED ON THE PLAN AND AS INDICATED IN
E COLUMN SCHEDULE.
E. RTIGAL REINFORCING EACH 5IDE OF ANY OPENING, IF REQUIRED, SHALL BE
G NTINUOUS TO THE TIE BEAM. PRECAST LINTELS SHALL HAVE OPENINGS TO ALLOW
INFORCINO BAR5 TO CONTINUE UNINTERRUPTED.
HORIZONTAL:
A. HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SCHEDULED IN THE BEAM
SCHEDULE.
B. HORIZONTAL JOINT REINFORCEMENT SHALL CONSIST OF AT LEAST q GAGE LADDER
TYPE REINFORCEMENT SPACED NOT MORE THEN Ib" 0/0 VERT. REINFORCEMENT SHALL
AL50 BE PROVIDED AT THE BOTTOM AND TOP OF ALL OPENIN05 AND EXTEND NOT LE55
THEN 24" BEYOND THE OPENING. PROVIDE 5" MIN EMBEDMENT INTO CONCRETE COLUMNS
AND BEAMS AND FULL DEPTH LAPS AT ALL MASONRY "L" AND "T" INTERSECTIONS.
5. GENERAL:
A. STRUCTURAL DESIGN 15 IN ACCORDANCE WITH 7.M.5. 402-I6, BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY ON BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES.
B. CONSTRUCTION SHALL BE IN ACCORDANCE WITH T.M.5. 602-I6, SPECIFICATIONS FOR
MASONRY STRUCTURES AND THE COMMENTARY ON SPECIFICATIONS FOR MASONRY
STRUCTURES.
G. IN HVHZ AREAS THE BUILDER SHALL EMPLOY A SPECIAL INSPECTOR APPROVED BY THE
BUILDING OFFIGAL TO ENSURE COMPLIANCE WITH THE APPROVED 5TRU07URAL PLANS IN
ACCORDANCE WITH SECTION 2122.2.4 F.B.G.
6. VERTICAL CELLS FOR MASONRY TO BE GROUTED SHALL HAVE VERTICAL ALIGNMENT
SUFFICIENT TO MAINTAIN A CLEAR, UNOBSTRUCTED CONT. CELL.
7. GLEANOUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF GROUTED CELLS AT
EACH LIFT OVER 4'-0" HIGH. GLEANOUT5 SHALL BE SEALED AFTER GLEANING AND
INSPECTION, AND BEFORE GROUTING.
STEEL NOTES
I. STRUCTURAL STEEL SHALL CONFORM TO THE AI50 "SPECIFICATION FOR THE DESIGN,
FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" . MATERIALS SHALL
CONFORM TO THE APPLICABLE A5TM SPECIFICATION AS FOLLOWS: W SHAPES - Agg2/A
gglM-06a, OTHER SHAPES - A56/A 36M-14, PLATES A36/A 36M-14, BOLTS - A 307-14
TUBULAR - ASTM A500/A50OM-13 GRADE B (46 K51)
2. WELDED CONSTRUCTION SHALL CONFORM TO THE AMERIGAN WELDING 50CIETY
"STRUCTURAL WELDING CODE". ELECTRODES FOR FIELD AND SHOP WELDS SHALL BE
A.W.5. A5.1 E70XX.
PLAN NOTES
I. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED
FOR REIN51"ECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN
SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRICAL PANEL.
2. PROVIDE 3" STEEL P05T OR BOLLARD OR TIRE BUMPER IN FRONT OF ALL EQUIPMENT
(HVAG, EHW, WASHER/DRYER) LOCATED IN THE GARAGE AT FLOOR LEVEL PER F.B.G.
MECHANICAL CODE.
3. PROVIDE Ix2 P.T. FIRE5TOP VERTICALLY AT THE CEILING AND FLOOR LEVELS.
HORIZONTALLY AT INTERVALS NOT EXCEEDING 10'-0", AND ALL OTHER LOCATIONS PER
F.B.G. SECTION R302.11.
4. ALL GLAZING WITHIN 24" OF EITHER 51DE OF THE DOOR PLANE IN A CLOSED POSITION
AND ON A WALL PERPENDICULAR TO THE PLANE OF THE DOOR ON THE HINGE 5IDE OF THE
DOOR (45" IN HVHZ) SHALL BE TEMPERED. ALL WINDOW5 OR 55LA55 ENCLOSURES AT OR
WITHIN 36" OF TUBS AND 5HOWER5 WITH SILLS LE55 THAN 60" ABOVE FLOOR SHALL BE
TEMPERED. ALL 6LA55 IN SIDELIGHTS, SLIDING GLA55 DOORS AND FRENCH DOOR5
SHALL BE TEMPERED.
5. EGRESS WINDOWS SHALL BE OPERABLE FROM THE IN51DE WITHOUT THE USE OF TOOLS.
EORE55 WINDOWS SHALL HAVE A MINIMAL NET OPENING OF 24" HIGH, 20" WIDE, AND MIN.
NET AREA OF 5.7 S.F. FOR 2nd FLOOR WINDOWS AND 5.0 S.F. FOR Ist FLOOR WINDOW5.
THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" ABOVE THE FLOOR, LATCH
AT 54" A.F.F. MAX. IN HVHZ AREAS WHERE THERE 15 MORE THAN A 4'-0" DROP, THE SILL
SHALL BE NO LE55 THAN 56" A.F.F. OR PROVIDE AN APPROVED 5AFEGUARD.
6. ALL BATHROOM FLOORS SHALL BE OF APPROVED IMPERVIOUS MATERIALS.
5. IN HVHZ AREAS PROVIDE HURRICANE 5HUTTER5 A5 PER F.B.G. SECTION 24-15 UNLE55
THE EXTERIOR WALL COMPONENTS OF THE ENCLOSED BUILDING HAS SPECIFIC PRODUCT
APPROVAL TO PRESERVE THE ENCLOSED BUILDING ENVELOPE AGAIN5T IMPACT LOADS
A5 SET FORTH IN CHAPTER Ib.
q. PICKETS AT STAIRS, LANDIN05 d BALCONIES SHALL BE SPACED TO PREVENT
PA55AGE OF A 4" DIAMETER SPHERE.
10. PROVIDE A MINIMUM OF 4" CLEAR ALL AROUND AIR HANDLER UNITS.
11. IN ZERO LOT LINE HOMES: DRYER VENTS, EXHAUST FANS $ KITCHEN HOODS SHALL NOT
VENT THROUGH THE 5IDE WALL AND MUST MAINTAIN A 10'-0" SETBACK.
FRAMING NOTES
I. THE TRU55 AND FLOOR SYSTEM LAYOUT SHOWN ON THI5 SHEET 15 SCHEMATIC IN
NATURE. HOWEVER, THE SUPPORTING SUPERSTRUCTURE HAS BEEN DESIGNED UNDER THE
ASSUMPTION THAT THE FRAMING 50HEME 5HOWN WILL OL05ELY PARALLEL FINAL TRU55
AND FLOOR SYSTEM DESIGNERS LAYOUT.
2. THI5 FRAMING 50HEME (DIRECTION OF TRU55E5 AND SLABS, MAJOR G.T. BEARING
POINTS, ETC) CAN BE MODIFIED ONLY AFTER OBTAINING PERMISSION FROM THE PRIME
PROFESSIONAL OF RECORD WHO MUST REVIEW PROPOSED CHANGES AND AUTHORIZE
STRUCTURAL REV1510N5 ACCORDINGLY.
3. FINAL 5IGNED AND SEALED ENGINEERED TRU55 AND FLOOR SYSTEM DESIGN MUST BE
SUBMITTED TO THI5 OFFICE FOR REVIEW. TRU55 AND FLOOR SYSTEM DE5I6NER5 MUST
PROVIDE ALL TRU55 CONNECTIONS AS PART OF THE DESIGN.
4. TRU55 AND FLOOR SYSTEM MANUFACTURER SHALL SUBMIT THREE (5) COPIES OF SHOP
DRAWIN65 AND ENGINEERING CALCULATIONS 5IGNED AND SEALED BY A FLORIDA
REGISTERED ENGINEER, OF THEIR DESIGN FOR REVIEW INCLUDING TWO (2) COPIES FOR
ARCHITECT/ ENGINEERS REVIEW PRIOR TO FABRICATION. REVIEW OF SHOP DRAWINGS IS
A COURTESY BY THE ARCHITECT/ ENGINEER AND IN NO WAY RELIEVES THE
MANUFACTURER OF H15 RESPONSIBILITY TO PROVIDE A LAYOUT THAT FULLY
INTEGRATE5 WITH THE ARCHITECT/ ENGINNER5 SUPERSTRUCTURE. IF THERE 15 ANY
CONFLICT OR ADDITIONAL STRUCTURE NEEDED, THE TRU55 AND FLOOR SYSTEM
COMPANY SHALL NOTIFY THE ARCHITECT/ ENGINEER IN WRITING OF THE SPECIFIC
AREAS OF CONCERN.
5. TRUSSES TO BE DESIGNED TO CARRY LOAD5 OF ATTIC AHU AND MISC. EQUIPMENT.
COORDINATE LOCATIONS WITH BUILDER PRIOR TO FABRICATION AND INDICATE ON
TRU55 DRAWIN657HE BUILDER SHALL BE RESPONSIBLE FOR THE COMPLETE
COORDINATION BETWEEN THE TRU55 DESIGN AND AIR CONDITIONING DESIGN
REQUIREMENTS.
6. ARCHITECT NOR ENGINEER ACCEPTS ANY RESPONSIBILITY FOR STRUCTURAL BEAMS,
COLUMNS, AND FOOTINGS UNTIL REVIEW OF APPROVED TRU55 AND FLOOR SYSTEM
DRAWIN65, 5IGNED AND SEALED BY A FLORIDA RE6I5TERED ENGINEER.
7. ALL INTERIOR LOAD BEARING PARTITIONS TO BE CONSTRUCTED WITH CLIPS, TOP AND
BOTTOM EACH STUD.
PROPOSED RESIDENCE
NETTLES ISLAND
ST LUCIE COUNTY, FLORIDA
ELECTRICAL SYMBOLS LEGEND PLAN / ELEVATION SYMBOLS LEGEND ���jj��
ROPPED SOFFIT
DUPLEX RECEPTACLE/ ARC CIS SINGLE RECEPTACLE r HVAG � PADDLE FAN W/ cM CARBON MONOXIDE/
�/111/720E HDEIGHT AS NOTED
FAULT INTERRUPT a 12" A.F.F. i DEDICATED Q THERMOSTAT OR NO/ LIGHT SM. DETECTOR COMBO
( Uc DUPLEX REGEPAIGLE GFI SINGLE RECEPTACLE n INTERCOM FLOURESGENT cM GERBO�RMONOXIDE # DETAILSALE O DOOR LABEL 000# MAX. TRUSS GONNEGTOR ARCHED OPENING SEE
11 UNDER COUNTER DEDICATED GFI `T' AT 60 A.F.F. LIGHT FIXTURE TO-0 PLAN OR ELEV.
DUPLEX RECEPTACLE AT 51NOLE RECEPTACLE SECURITY FLOURE50ENT sD SMOKE
c 5" ABV. COUNTER D DEDICATED UNDERGOUNTER KEYPAD LIGHT FIXTURE DETECTOR O N WINDOW LABEL
DUPLEX RECEPTACLE 5WITGH 4 GARAGE PUSH INCANDESCENT LIGHT SPEAKER # DETAIL GROUT FILLED CELL SEE
GFI GROUND FAULT INTERRUPT SINGLE POLE BUTTON FIXTURE GEILING MOUNTED IN GLG. UwG. SCALE NORTH ARROW FOUNDATION PLAN
c DUPLEX RECEPTACLE AT 5" ABV. 5WITGH DOOR BELL INCANDESCENT LIGHT HR
GFI COUNTER GROUND FAULT INTERRUPT T3 THREE WAY vP FIXTURE- VAPOR PROOF HOME RUN G# COLUMN LABEL
� DOOR CHIME BREAK LINE POURED CONCRETE
® DUPLEX RECEPTACLE 5WITGH INTERIOR INCANDESCENT LIGHT V VOLUME # SECTION COLUMN
G.V. CENTRAL VACUUM FIXTURE WALL
TOP REC. SWITCHED T4 FOUR WAY MOUNTED SCALE CONTROL FOOTING LABEL
DWG. F#
wP DUPLEX RECEPTACLE WATERPROOF 5WITGH RECEPTACLE O
GFI GROUND FAULT INTERRUPT TD DIMMER ® HI HAT- RECESSED �� GAS DROP
NON -BEARING FRAME
TION CONSTRUCTION
DUPLEX RECEPTACLE 5" ABV. GV CENTRAL VACUUM a SHEARWALL LABEL FRAME OR BELU IN
c TELEPHONE OUTLET ® HI HAT- RECESSED L V LOW VOLTAGE # SECTION - - - - ABOVE OR BELOW
RWP/GFI COUNTER WATERPROOF GFI V AT 12" A.F.F. VAPOR PROOF PANEL
SECURITY DWG. 50ALE
QUADRUPLEX LIGHTS RECESSED 5WITGH CONSTRUCTION
RECEPTACLEFRAME
TELEPHONE OUTLET ELEV. BEAM HEIGHT
REGEPTAGLE Y FLUSH IN FLOOR EYEBALL DISCONNECT $-# BEAM LABEL ELEV. CHANGE
LED LIGHT
DUPLEX RECEPTACLE ELECTRICAL o 2' 4' 8
� FLUSH IN FLOOR DEDICATED EXHAUST
DATA LINE F B FAN BOX FAN ® BREAKER PANEL
scA�e: va° = r-o° # REVISION MASONRY CONSTRUCTION
TELEVISION JACK JUNCTION BOX/ GLG. EXHAUST FAN
® 220 V. RECEPTACLE �O'-O" FIN. FL. 5LAB FLOOR ELEVATION
AT 12" A.F.F. � F.P.BL. METER 8 GRAPHIC SCALE TYPICAL
4 PREWIRED Ed MOUNTED LOW VOLT. F L /LIGHT COMBO DISC.
CONTINUED
5. STRUCTURAL WOOD AND TIMBER FRAMING SHALL CONFORM TO THE "TIMBER
CONSTRUCTION MANUAL" AS PUBLISHED BY THE AMERIGAN INSTITUTE OF TIMBER
CONSTRUCTION.
q. ALL WOOD IN CONTACT WITH MA50NRY OR CONCRETE SHALL BE PRESSURE TREATED.
PROVIDE AN APPROVED MOISTURE VAPOR BARRIER BETWEEN THE CONCRETE OR OTHER
GEMENTITOU5 MATERIALS AND THE WOOD AS PER CODE.
10. BUILDER SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE BRACING AND
BRIDGING USED DURING ERECTION OF TRUSSES AND STRUCTURAL SLABS TO PREVENT
COLLAPSE OR DAMAGE.
11. HEADERS FOR FRAMED OPENINGS GREATER THAN II MUST BE ENGINEERED AND
STAMPED BY THE TRU55 MANUFACTURER. (UNLESS NOTED OTHERWISE)
12. ALL HEADERS OVER DOORS AND WINDOWS TO BE (2) OR (3) 2XI2'5 UNLE55
OTHERWISE NOTED. (FOR WOOD FRAME CONSTRUCTION DEPENDING ON ALL WALL
THICKNESS).
15. DIMENSIONAL LUMBER SHALL BE SOUTHERN PINE. NO. 2 OR BETTER AND SHALL
PROVIDE ALLOWABLE 5TRE55 VALUES OF 1200 P51 IN BENDING FOR A 51NOLE MEMBER
USES. qO P51 IN HORIZONTAL SHEAR AND SHALL HAVE A MODULES ELASTICITY OF Ib00
K51 OR BETTER, AS DETERMINED BY AN APPROVED LUMBER GRADING AGENCY.
14. NON -BEARING INTERIOR PARTITIONS MAY BE CONSTRUCTED OF 25 GAUGE GEE
CHANNEL TYPE STUDS AT 24" 0/G WITH MATCHING TRACKS TOP AND BOTTOM, WITH 1/2"
GYPSUM DRYWALL EACH 5IDE. ATTACH DRYWALL WITH I" LONG BUGLE HEAD DRYWALL
SCREWS AT 12" 0/0 MAX.
15. METAL LATH OVER 5HEATHIN6 SHALL BE 3/5" V-GROVE OR DIMPLED. CEILINGS AND
SOFFITS SHALL BE HIGH RIB TYPE. FASTEN TO 5UB5TATE AT 4" 0/0 A5 FOLLOW5;
CONCRETE: 3/4" LONG 5TUB NAILS W/ 3/6" HEAD. HORIZONTAL AND VERTICAL WOOD
FRAMING MEMBERS W/ NAILS OR STAPLES TO PROVIDE AT LEAST I-5/4" PENETRATION
INTO HORIZONTAL WOOD FRAMING MEMBERS, AND 3/4" PENETRATION INTO VERTICAL
WOOD FRAMING MEMBERS. ON VERTICAL WOOD FRAMING MEMBERS, COMMON NAILS
SHALL BE BENT OVER TO ENGAGE AT LEAST THREE STRANDS OF LATH, OR BE BENT
OVER A RIB WHEN RIB LATH IS INSTALLED. 5HEATHING: 14 GAUGE STAPLES I" LEG, 7/I6"
GROWN METAL MTL. FRAMING: SELF TAPING 50REW5 #12 x I/2" WA5HER HEAD STAPLES
SHALL NOT BE USED FOR 5OFFIT5 OR CEILINGS
I6. WHERE CEMENT PLASTER 15 APPLIED TO LATH OVER FRAME CONSTRUCTION, BONDING
OF THE PLASTER TO THE WATER BARRIER SHALL BE PREVENTED BY PROVIDING A DBL.
LAYER OF WATER BARRIER OR BY INSTALLING A HOUSE WRAP BENEATH THE WATER
BARRIER.
17. PNEUMATIC FASTENERS SYSTEM TO BE HILTI-COIL NAIL PROGRAM. TYPE TO BE GRF
1126 I-1/2" LONG AND .120" DIAMETER U.N.O.
15. WHEN WOOD P05T5 ARE NOT IN A FIRERATED WALL, FIRE RATE 1-05T AS FOLLOWS:
WRAP P05T ON ALL 51DE5 FROM BASE OF P05T TO UNDERSIDE OF BEARING WITH (1)
LAYER OF 5/5" TYPE "X" GYPSUM WALL BOARD. THI5 WILL PROVIDE A ONE HOUR RATING
FOR THE POST.
Iq. TRU55 MANUFACTURER SHALL DESIGN TRUSSES TO COMPLY WITH ALL SUPERIMPOSED
WIND LOAD5 PER F.B.G. 2020.
MECHANICAL NOTES
I. ALL HEATING, AIR CONDITIONING, REFRIGERATION AND VENTILATION EQUIPMENT SHALL
CONFORM TO THE REQUIREMENTS SET FORTH IN THE "FLORIDA BUILDING CODE
MECHANICAL" AND FLORIDA BUILDING CODE ENERGY CONSERVATION .
2. A 4" CLEARANCE 15 TO BE MAINTAINED AROUND ALL AIR HANDLING UNITS.
3. PROVIDE FIRE DAMPERS AT SUPPLY AND RETURNS WHICH PA55 THROUGH RATED
A55EMBLIE5 IF ANY.
4. ALL DWELLING ROOMS MUST HAVE HVAG RETURNS. RETURNS MAY BE DUCTED,
JUMPERS OR TRANSFER GRILLE5.
5. A/C UNITS MAY HAVE GONG. PAD OR OTHER APPROVED MATERIAL EXTENDING ABV.
ADJOINING GRADE OR SHALL BE SUSPENDED A MIN. OF b" ABV. ADJOINING GRADE.
PAD5 SHALL BE A MINIMUM 4'-0"xq'-O" PAD FOR DOUBLE UNIT.
PLUMBING NOTES
I. ALL PLUMBING FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 405,
F.B.G. FLOOR DRAINS TO HAVE TRAP PRIMERS PER F.B.G 10024.
2. ALL PLUMBING FIXTURES SHALL MEET THE REQUIREMENTS OF TABLE 604.5, F.B.G.
3. DISPOSITION OF RAIN WATER SHALL COMPLY WITH F.B.G. PLUMBING CODE CHAPTER 11.
4. ALL PLUMBING PENETRATIONS MUST BE A MINIMUM 10'-0" FROM ROOF JACKS.
5. CONDENSATE DRAINS MUST BE A MINIMUM OF 12" OFF THE BUILDING.
6. 5HOWER COMPARTMENTS AND WALLS ABOVE BATH TU55 WITH 5HOWER HEADS SHALL
BE FINISHED WITH A SMOOTH, NONAB50RBENT SURFACE TO A HEIGHT NOT LE55 THEN
70 INCHES ABOVE THE DRAIN INLET.
7. CAULK OR SEAL FIXTURE/ PLUMBING PENETRATIONS AND ABUTMENTS TO P1551MILAR
MATERIALS. DO NOT USE ALL-PURPOSE JOINT COMPOUND OR PAPER TAPE IN NET
AREAS.
5. ALL SHOWER HEADS SHALL BE EQUIPPED W/ ANTI -SCALDING PROTECTION PER CODE.
ELECTRICAL NOTES
I. CONTRACTOR SHALL VERIFY WITH F.P.&L. THE LOCATION OF SERVICE AND SHALL
LOCATE METER B PANELS AS REQUIRED.
2. ALL WIRE SHALL BE THHN COPPER. UNLE55 NOTED OTHERWISE.
3. WHERE REQUIRED BY OTHER CODES, SERVICE AND FEEDER CONDUCTORS SHALL BE
COPPER OF EQUAL AMPAGITY.
4. ALL BRANCH CIRCUITS IN RACEWAY OR NON METALLIC SHEATHED GABLE.
5. COORDINATE RACEWAY INSTALLATIONS WITH OTHER TRADES PRIOR TO
CONSTRUCTION.
6. VERIFY ALL CONDUCTORS AND BREAKERS WITH EQUIPMENT MANUFACTURER
SPECIFICATIONS.
7. PROVIDE DISCONNECT SWITCH OF 51ZE AS REQUIRED BY LOAD AND UNITS.
5. PROVIDE NON-FU5IBLE GENERAL DUTY SAFETY 5WITGHE5 AT A/G EQUIP. AND AT
PUMPS NOT VISIBLE FROM CIRCUIT BREAKER PANEL AND AS PER MANUFACTURER.
RECOMMENDATIONS.
q. PROVIDE GFGI PROTECTION FOR ALL BATHROOM, GARAGE, EXTERIOR, KITCHEN,
LAUNDRY AND NET BAR OUTLETS PER NEC 210.5(A).
10. ELECTRICAL FIXTURES, TRIM AND APPLIANCES SHALL BE UL APPROVED AND A5
SELECTED BY OWNER.
11. PROVIDE PRE -WIRED TELEPHONE, T.V. OUTLETS OUTLETS A5 5HOWN ON PLAN.
12. ALL OL05ET LIGHTING SHALL COMPLY WITH NEC SEC. 410.5.
15. THE BRANCH CIRCUITS CONTAINING SMOKE DETECTORS SHALL HAVE ARC -FAULT
PROTECTION PER NEC SEC. 210.12 SMOKE DETECTORS SHALL BE CONNECTED TO
ARC, -FAULT CIRCUITS AHEAD OF SWITCH AND HAVE SELF CONTAINED BATTER BACK-UP.
DETECTORS SHALL BE TANDEM WIRED 50 ALL DETECTORS SOUND SIMULTANEOUSLY.
14. PRE -WIRE FOR GARAGE DOOR OPENER SENSOR.
15. PROVIDE ARC -FAULT CIRCUIT INTERRUPTER PROTECTION IN DWELLING UNIT LIVING,
DINING, FAMILY ROOMS, DENS/ LIBRARIES, BEDROOMS, 5UNROOM5, GL05ET5, HALLWAYS,
KITCHEN AND LAUNDRY ROOMS OR SIM. ROOMS PER NEC 210.12.
16. SMOKE DETECTORS:
III REQUIRED ON ALL HVAG UNITS WITH 2O01 GFM OR MORE.
16.2. CEILING AREA: 110 V. SMOKE ALARMS SHALL BE INSTALLED NOT LE55 THAN 3 FEET
HORIZONTALLY FROM THE DOOR OR OPENING OF A BATHROOM THAT CONTAINS A
BATHTUB OR SHOWER UNLE55 THI5 WOULD PREVENT PLACEMENT OF A SMOKE ALARM
REQUIRED BY SECTION R314.3.
III NEAR COOKING APPLIANCES. SMOKE ALARMS SHALL NOT BE INSTALLED IN THE
FOLLOWING LOCATIONS UNLE55 THI5 WOULD PREVENT PLACEMENT OF A SMOKE
ALARM IN A LOCATION REQUIRED BY SECTION R314.3.
- IONIZATION SMOKE ALARMS NOT BE INSTALLED LE55 THAN 20 FEET HORIZ. FROM
A PERMANENTLY INSTALLED COOKING APPLIANCE.
- IONIZATION SMOKE ALARMS WITH AN ALARM-51LENCIN6 5WITGH SHALL NOT BE
INSTALLED LE55 THAN 10 FEET HORIZ. FROM A PERMANENTLY INSTALLED COOKING
APPLIANCE.
- PHOTOELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LE55 THAN 6 FEET
HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE.
17. CARBON MONOXIDE ALARM TO BE INSTALLED WITHIN 10' OF A ROOM USED FOR
SLEEPING PURPOSES WHEN THE BUILDING HAS A F0551L BURNING HEATER OR APPLIANCE,
A FIREPLACE, OR AN ATTACHED GARAGE. PRIMARY POWER SHALL COME FROM THE
BUILDING WIRING WHEN SUCH WIRING 15 SERVED BY THE LOCAL POWER UTILITY. SUCH
ALARMS SHALL HAVE BATTERY BACKUP. IF USED, A COMBINATION SMOKE/ CARBON
MONOXIDE ALARM SHALL BE L15TED OR LABELED BY A NATIONALLY RECOGNIZED
TESTING LABORATORY.
15. TAMPER RE515TANT RECEPTACLES ARE REQUIRED IN DWELLING UNITS IN ALL AREAS
SPECIFIED IN NEC 210.52 FOR 125 VOLT, 15 8 20A RECEPTACLES PER NEC 406.11
Iq. INTERSYSTEM BONDING TERMINATION FOR CONNECTING INTERSYSTEM BONDING AND
GROUNDING CONDUCTORS SHALL BE PROVIDED FOR TV, COMMUNICATIONS, RADIO, CAN,
ETC. PER NEC 25OA4. (A) OR (B)
20. PER FBG-E 404.1 LIGHTING EQUIPMENT. A MINIMUM OF 75 PERCENT OF THE
LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE
HIGH -EFFICACY LAMPS.
21. BOXES AT LUMINAIRE OUTLETS: BOXES USED AT LUMINAIRE OR LAMP HOLDERS IN A
CEILING SHALL BE DESIGNED FO THE PURP05E AND SHALL BE REQUIRED TO SUPPORT A
LUMINAIRE WEIGHING A MIN. OF 23KG (50 LB). NEC 314.27A.
22.PROVIDE ADEQUATE CLEARANCE FOR ELECTRICAL EQUIPMENT REQUIRING SERVICE WHILE
ENERGIZED SUCH A5 SERVICE EQUIPMENT, PANEL BOARDS, DISCONNECTS ETC. A5 PER NEC, 110.26
23.ALL GFI SHALL BE INSTALLED IN READILY ACCE551BLE LOCATIONS PER NEC, 210.5.
CODES USED:
- FLORIDA BUILDING CODE 7TH EDITION (2020)
- FLORIDA BUILDING CODE - RE51DENTIAL 7TH EDITION (2020)
- NEC 2011
- A.5.0.E - 7-I6 R 1
DRAWING INDEX
LOAD SCHEDULE
LOCATION LIVE DEAD
TOTAL
6-1
COVER SHEET
GROUND FLOOR 40 60
100
A5-1
51TE PLAN
SECOND FLOOR 40 25
65
A -I
FLOOR 8 SECOND FLOOR PLANS
TOP CHORD 40 20
A-2
ELEVATIONS
BOTTOM CHORD 0 5
BALCONIES 60 25
55
A-3
SECTION 8 PLUMBING R15ER
ROOF 30 25
55
TOP CHORD 30 15
5-1
FOUNDATION PLAN 8 DETAILS
BOTTOM CHORD 0 10
5-2
5ECOND FLOOR d ROOF d LOW ROOF FRAMW PLAN
BTM. CHORD -ATTIC 10 0
NO 5TORA6E (NON -CONCURRENT)
5-2.1
FRAMING DETAILS
BTM. CHORD -ATTIC 20 0
5-3
ROOF BRACING PLANS
5TORA6E (CONCURRENT)
E-I
15T 8 2ND FLOOR ELECTRICAL PLAN
RAIN:
ADOT'L TOP CHORD * 0
INTENSITY 4.5 in/hr
* - N/A
(IF SLOPE > I3:12 OR HIP ROOF OR NO 0155TRUGTION FOR
RAIN WATER DRAINAGE)
WIND:
ULTIMATE WIND SPEED = 170 m.p.h.
NOMINAL WIND SPEED = 152 m.p.h.
RI5K GATAOORY = II
BUILDING DE516N A5 ENCL05ED
INTERNAL PRE55URE COEFFICIENT = +/- 0.15
EXP05URE CATEGORY = D
MEAN ROOF HEIGHT = 22'-10"
ROOF SLOPE 4:12
ROOF DEAD LOAD FOR WIND
DESIGN TAKEN AT 10 p.5.f.
NOTE: THI5 STRUCTURE 15 DE51ONED IN
ACCORDANCE WITH CHAPTER 16 OF THE 2020
FLORIDA BUILDING CODE AND ASCE 7-Ib.
CONSULTANT INFO (OPTIONAL)
THESE PLANS WERE PREPARED
USING THE 2020 FLORIDA
BUILDING CODE, 7TH ED. -
BUILDING AND ASCE 7-16.
revisions
no. date
designed PAR
drawn
PAR
checked
55
date
11/25/21
scale
1/4" = 1'-0" U.N.O.
job no.
21-0041 . LOW
QLA
QUANTUM ENGINEERING ASSOCIATES INC.
•
Structural Engineering & Cost Segregation
6415 LAKE WORTH ROAD
SUITE 105
GREENACRES, FLORIDA 33463
W W W.QEASSOCIATES.COM
•�cn"s'rgMe,,
ENSF•�G'% Digitally signed
�? No 61 6O •'CZ
by Shawn
3% SE of
'��F`•:c(OR�p P': �j�?,. Stambaugh
", m�ONAL�.,° Date:
This item has been electronically
signed E-th, dby Shawn R.g 2022.01.27
Baugh, PE ,g the dateshown usinga
Digital Signature.
Printed copiesofthis documentare 15:48:22-05'00'
nsidered signed and sealed and
the signature must be verified on any
lectronic copies
Shawn M. Stambaugh, PE
FL. LIC. 61850 - C.A. 26210
LU
U
Q
Z
LU
z
Q
Q 0
J ILL.
LU
L Z
1..L
z0
LU
w
oU
o ZD
0
J
J
0�
J Cn
project
U
J
J
Z
J
U]
W
�
U
Z
O
a
W
-
z
Z
us
Z
L7
LL
(A
W
�
iu
v
Z
U_
CQ_ <L-
l7
Ul
W
drawing
COVER SHEET
sheet
G-1