Loading...
HomeMy WebLinkAboutGENERATORINCLUDES: • True Power" Electrical Technology • Two Line LCD Multilingual Digital Evolution'" Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. • Electronic Governor • System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector Standby Power Rating Models G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-1, G007042-1 (Aluminum - Bisque) - 22 kW 60 Hz • Direct -To -Dirt Composite Mounting Pad` • Natural Gas or LP Gas Operation c@us. QUIET-_ " • 5 Year Limited Warranty Note: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL certified in • Capability to be installed within 18" (457 mm) the USA only. of a building* *Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O success in providing the most reliable generators possible. Generac's G-force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 %. SINGLE SOURCE SERVICE RESPONSE from Generads extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are J PROTOTYPE TESTED J NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. w GENERAC .st'•3ss ,�y-� •c®r *©� Mobil` ' I— PROMISE W Link �r�KEP Gp �gAflP�`- "uuur rn I*e usn ui�u evmearc one ram(ve nerts. t GENERACO 16/20/22 kW features and benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinderwalls and plasma cooly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth outputwaveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 311 Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution'" Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator'from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key. locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. Installation System • 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. 0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. GENERAL' 16 20/22 kW specifications Generator G007035-0, G007036.0, 0007038-0, G007036-0 G007042-1, G007043-1 Model G007037-0 (16 kW) (20 kW) (22 kW) °' 16 000 Watts* 20,000 Watts' 22,000 Rated Maximum Continuous Power Capacity (LP) , ,; - _ Rated Maximum Continuous Power Capacity (NG)�16,000 Watts* 18,000 Watts* 19,500 a--�--p-.-a�_ Aated Voltage . • `�- _ _ �240 ° ` _ 40 240. L4 Rated Maximum Continuous Load Current - 240 Volts (LP/NG) 66.6/66.6 83.3/75 91.6/81.3 Total Harmonic Distortion, ' « Mess than,5% Less than 5°Io Less than 5% Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp Phase Number of Rotor Poles 2 2 .2 ated,ACFrequency'� T 4 Hz 60 Hz ry 60Hr Power Factor 1.0 1.0 1.0 Battery Requirement (not Included�TT _ - '° 12 Volts, Group 6-fF640 CCA M nlmumorGroup 35AGM 630 GCA Minimum Unit Weight (Ib/kg) 406/186 448/203 466/211 •—.���] a '.` `48 05x 29/1218 x638 x732 , - Sound output in d8(A) at 23 ft (7 m) with generator operating at normal load" 66 66 67 Sound output m d8(A) al 23 h (7 m).wi)h generatorm Oujet-Test glow-speed�exetcise mode ' 58r n 58 T r .: - •• = 58 _ -, Exercise duration 5 min 5 min 5 min Engine Type of Engine GENERAC G-Force 1000 Series Number of Cyfinders u �999 Displacement 9 cc 999 cc� cc tt���-- Aluminum w/,Cast'Iron Sleeve _ CylinderBlock'ttt _ �. Valve Arrangement Overhead Valve Overhead Valve Overhead Valve lgnitjon System _ t� t x Solid state w/ Magneto> - Solid-statew/ Magneto _77Solid-state w/ Magneto A .' Governor SystemF Electronic Electronic Electronic rc- ompesston Ratio fi �' 9 51 " 51 Starter 12 VdcJ 12 Vdc 12 Vdc iacityincludingfiltei pl:9 qUt 8 L . _t . ApproX.1:9 gV1.8'L }' ° • Approx, l.9 gV1.8 Oil Ca Approx Operating rpm 3,600 3,600 3,600 Fuel Consumption Natural Gas ;ft3lhr (m3/h) 1/2 Load,, , 218 (6 1.7)` 204 (5 78) 228 (8.46) Full Load 8 309 (8.75)301 (8 52) 327 (9.26) LlgwdPropane ft3/hr,(gal/hr)[I/h�J"� 1/2 Lozri (2 52) [9.53] 86 (2.37) [8.991� '. 92 R53) [9 57] Full Load •° 106 8 (2 94) [11 11] 129:6 (3 56 [13�48] ,• 1 2-(3.90) [14 771 Note. Fuel pipe must be sized for full load Required fuel pressure to generator fuel inlet at all load ra s - 3.5-7" water column (7 13 m mercury) for natural gas,10-12" water column (19-22 mm mercury) for LP gas. For Btu content, multiply fts/hr x 2500 (LP) or ft3/hr 0 000 (NG). For Megajoule content, multi m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG) Controls 2-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. Manual Start with starter control, unit stays on. If utility fails, transfer to load takes place. �1if„ ` ,; �'� � � ��� Stops`unit.;Power-)sremoved.Controlandcharge[•still operate. ; Ready to Run/Maintenance Messages Standard EngineRun Hourslndication '.=77Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Utility Voltage LosslReturn to Utility -Adjustable (Brownout Setting_ .From 140 i71 V/190 216 V Future Set Capable Exerciser/Exercise Set Error Warning Standard Eu:n/Alarm/Maintenance Logs� „ ; 50 Events ach Engine Start Sequence Cyclic cranking:16 sec on, 7 rest (90 sec maximum duration). Starter Lock -out,' � _ —Starter cannot re-engage until 5 sec afterengine has stopped.. - Smart Battery Charger �CfiargerFaulVMissingAC.MRng: • �` Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard �qutomatip=VoltageRegulat(on;wjthOverand UnderVoltage Rroteotion .� �,r� .,;•t - .�,.,,.,_„_..,._.., Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safe Fused/Fuse Problem Protection g " ° ' " ' `" _Standard.. _ Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrar klOverspe d (@ 72 Hz)/rpm Sense Loss'Shutdown tt 'v Standard High Engine Temperature Shutdown Standard Internal FaulVlncorrecPWirin Protection a •Standard, Common External Fault Capability. _Standard "Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator maybe higher depending on installation parameters. Rating definitions -Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). *Maximum kilovolt amps and current are subject to and limited by such factors as fuel Btu/megaloule temperature, engine condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent far each 6 °C (10 °H above 16 °C (60 "F). content, ambient altitude, powerand GENERAC� �0/22 W. switch options Limited Circuits Switch Features • 16 space, 24 circuit, breakers not included. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load,100%D equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. . • Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from ,Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions Height Width H1 H2 W1 W2 Depth inENE75 30.1 10.5 13.5 6.91 mm764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 210-#14 210-#14 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load, 100% equipment rated, both inductive and resis- tive. • 2-pale, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and capper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 120/240.10 Open Transition Service Rated Height Width Depth Ht H2 W1 W2 in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 .343.0 175.4 Model G007036-0 (16kW) tN°. PoIes Current Rating (Amps) LVoltage Rating (VACj 100 _ 120/240,10 ' Utility Voltage Monitor (Fixed)* -Pick-up -Dropout 80% 65% Return to utility' approx.15 sec j �'� Exercises bi-weekly far 5 minutes't Standard ULListed • Standard _ Total Circuits Available 24 Tandem Breaker Capabilities 8 tandems Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volts 10,000 *Function of Evolution Controller Exercise can be set to weekly or monthly DEPTH Model G007037-0 (16 kW)/G007039-0 (20 kW)/ G007043.0 (22 kW) 40. -of Poles 2. _,_ �a. Current Rating (Amps) 200 Voltage'Rating (VAC) 120/240;,10 Utility Voltage Monitor (Fixed)* -Pick-up -Dropout 80% 65% RetumtoUtility'� approz.l3sec Exercises bi-weekly for 5 minutes' Standard UL Listed . Standard _ Enclosure Type NEMA/UL 3R Circuit Breaker Protected � - . 22,000 _ Lug Range . 250 MCM - #6 *Function of Evolution Controller Exercise can be set to weekly or monthly DEPTH GENERAC i 0/22 kW available. accessories Model # _" Product Description__ � � p constant monitoring of the connected LP fuel tank. Mon- WI-Fi enabled LP fuel level monitor provides the LP tank's fuel level is an important step in making sure your generator is ready to run during an G007005-0 Wi-Fi LP Fuel Level Monitorng f�unexpectedpower failure. Status alerts are available through a free application to notify when your LP tank need of a refill. Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- G006463-4 Mobile Link`" cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or text message when a change in the generator's status occurs. Available in the U.S. only. Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet G005819-0 26R Wet Cell Battery cell battery for use with all air-cooled standby product (excluding PowerPact®). The pad warmer rests under the battery. Recommended 'for use if the temperature regularly falls below 0°F. G007101 0 Battery Pad Warmer (Not necessary for use with AGM -style batteries). Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below G007102 0 Oil Warmer 0°F. Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load G005621 0 Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007027-0 - Bisque Fascia Base Wrap Kit sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting (Standard on 22 k" holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from G005703-0 - Bisque Paint Kit future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. G006873-0 Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its Smart Management Module power management capabilities. It provides additional power management flexibility notfound in any other (50 Amps) power management system. dimensions & PCs Dimensions shown are approximate. Referto installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. LEFT SIDE VIEW I...1f] FROM VIEW Model . UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 606471070378 G007038-0 696471070385 6007039-0 696471070392 G007042-0 696471070422 G007043-0 696471070439 G E N E RACO Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com 02017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. 10000000194-F 5/3117