Loading...
HomeMy WebLinkAboutEVALUATION REPORT - CONCRETE ROOF TILESQ0TP,uN1TYJERD EVALUATION REPORT EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 17=0 �p �c- /�, Entegra Roof Tile, LLC Evaluation Report E39310.11.11-1-R3 N 1 EGIQ 1 1289 NE 9th Avenue FL7804-119 F: O O 1= T 1 L E Okeechobee, FL 34972 Date of Issuance: 11/02/2011 Revision 3: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule '61G20-3 and the applicable rules and regulations governing the use,of construction. materials in the State of Florida. -The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code' and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code (HVHZ) sections noted herein. DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions) LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the. user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 04/18/2016. This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. t'• , rTRINITY I ERD ROOFING SYSTEM EVALUATION: 1. SCOPE: ` Product Category: Roofing i Sub -Category: Roofing Tiles I Compliance Statement: Entegra Concretes Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance -is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pro e 1523.6.5.2 Physical Properties 1523.6.5.2 Wind Driven Rain 1523.6.5.2.2 Static Uplift Resistance 1523.6.5.2.3 Static Uplift Resistance 1523.6.5.2.3 Static Uplift Resistance 3. REFERENCES: Enti Examination ERD (TST6049) TAS 101 ATL (TST3782) Physical Properties ATL (TST3782) Physical Properties ATL (TST3782) Physical Properties ATL (TST3782) Physical Properties I ATL (TST 3782) Physical Properties I ATL (TST 3782) Physical Properties ATL (TST 3782) Physical Properties I ATL (TST 3782) Physical Properties ATL (TST 3782) Physical Properties Miami -Dade (CER1592) HVHZ Compliance Miami -Dade (CER1592) HVHZ Compliance C Miami -Dade (CER1592) HVHZ Compliance Miami -Dade (CER1592) HVHZ Compliance Miami -Dade (CER1592) HVHZ Compliance Tile Roof Institute TA5100, TAS 101, 102, 102(A) PRI (QUA9110) Quality Assurance Exterior Research and Design, I.I.C. Certificate o/Authorization #9503 Standard TAS 112 TAS 100 TAS 101 TAS 102 TAS 102(A) Reference P39740.02.12 RT0624.05-14 RT0624.04-14 RT1210.02-15 RT1210.03-15 RT1103.01-15 RT1103.02-15 RT1103.03-15 RT1103.04-15 RT1103.05-15 14-0416.12 15-0721.04 16-0112.06 16-0112.07 16-0112.08 Membership Confirmation Inspection Report Year 1995 1995 1995 1995 1995 Date 02/21/2012 07/03/2014 07/07/2014 12/17/2015 12/17/2015 11/07/2015 11/07/2015 11/07/2015 11/07/2015 11/07/2015 11/27/2014 11/05/2015 02/25/2016 02/25/2016 02/25/2016 Current 11/04/2015 Evaluation Report E39310.11.11-1-R3 FL7804-R9 Revision 3: 04/18/2016 Page 2 of 9 TRINITY I ERD 4. PRODUCT DESCRIPTION: 4.1 BERMUDA FLAT, PLANTATION FLAT and HORIZON FLAT are TAS 112, Type 3a (flat -profile) concrete roof tiles. i- 16' � T4' I 10, r 16' � T- 2' 10' r 16�? Bermuda Flat Plantation Flat r, 13" '17-U4" � . Horizon Flat Exterior Research and Design, I.I.C. Certificate of Authorization #9503 Evaluation Report E39330.11.11-1-R3 FL7804-R9 Revision 3: 04/18/2016 Page 3 of 9 4.2 BELLA HIGH "S" are TI 4.3 ESTATE "S" and HACIE Exterior Research and Design, I.I.C. Certificate of Authorization #9503 INITY I ERD es. Evaluation Report E39310.11.11-1-R3 FL7804-R9 Revision 3: 04/18/2016 Page 4 of 9 I 5. i TRINITY I ERD 4.4 GALENA SPANISH "S" and REGAL are TAS 112, Type 2a (non -interlocking, high -profile) concrete roof tiles. 17" Galena Spanish "S" Regal 10" LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is. for use in FBC HVHZ jurisdictions or other jurisdictions adopting FBC HVHZ requirements. 5.3 Fire classification is not part of this evaluation; refer to FBC Section 1516 or current Approved Roofing Materials Directory for fire rating of this product. 5.4 Reference is made to FBC Section 1512.4.2.4 regarding field testing of completed tile roof installations. 5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in accordance with TAS 112, Appendix 'A'. Such testing shall be submitted to Trinity I ERD for review. 5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment products shall hold Florida Statewide Product Approval or Local Approval for. use in tile roof assemblies in HVHZ jurisdictions. 5J Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements. 5.8 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. Exterior Research and Design, I.I.C. Certificate of Authorization #9503 Evaluation Report E39310.11.11-1-113 FL7804-119 Revision 3: 04/18/2016 Page 5 of 9 6. �l TRINITY I ERD INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of RAS 118, RAS 119 or RAS 120, as applicable. 6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in accordance with RAS 127-11 usinle the data outlined herein. TABLE 1: AERODYNAMIC MULTIPLIERS-%L (FT3) Tile Batten Application Direct -Deck Application Bermuda Flat 0.189 0.205 Plantation Flat 0.267 0.289 Horizon Flat 0.305 0.330 Bella High "S" ` 0.349 0.378 Estate "S" 0.267 0.289 Hacienda I 0.267 0.289 Galena Spanish "S" N/A 0.235 Regal 0.287 0.311 TABLE 2: RESTORING MOMENT DUE TO GRAviTY - Mr (FT-LBF) Roof Slope (0) Tile 2:12<0<3:12 3:12<6<4:121 4:12<0<5:12 5:22<0<6:12 6:12<0<7:12 0>7:12 Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Bermuda Flat 5.22 6.43 5.17 6,37 5.09 6.27 4.98 6.15 4.86 6.00 4.72 5.83 Plantation Flat 7.22 7.91 6.85 7.79 I 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Horizon 1.60 8.32 7.52 8.241 7.41 8.12 7.26 7.95 7.09 7.76 6.89 7.55 Bella High "S" 6.19 6.89 6.11 6.80 1 . 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13 Estate "S" 6.14 6.84 5.91 6.74 j 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14 Hacienda 5.92 6.80 5.92 6.80 5.82 6.69 5.70 6.55 5.56 6.39 5.41 6.22 Galena Spanish "S" N/A 6.20 N/A 6.13 N/A 6.03 N/A 5.89 N/A 5.74 N/A 5.57 Regal 7.77 8.34 7.77 8.34 I 7.65 8.20 7.49 8.03 7.30 7.83 7.10 7.61 0 Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report E39310.11.11-1-R3 FL7804-R9 Revision 3: 04/18/2016 Page 6 of 9 J TRINITY ERD TABLE 3B-2: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT- MF (FT-LBF) LOW PROFILE TILES, MORTAR & ADHESIVE -SET SYSTEMS - Tile Application Adhesive Size (inch) Weight (g) Mf (ft-Ibf) To Substrate To Tile To Substrate To Tile Estate "S" or Hacienda Inter- Dependent TILE BOND'"` 1 x 6• 1 x 6 -11 -11 43.8 Touch'n Seal'" StormBond 1.25 x 10 0.75 x 10 -8.4 -5.1 41.8 ICP Adhesives Polyset RTA-1; cross -bond "5" long oblong -4.5 across head �6 ^5 44.0 ICP Adhesives Polyset AH-160 4 x 4 2 x 4 1 -16 1 -8 1 49.9 Independent ICP Adhesives Polyset AH-160 2 x 7 N/A -30 N/A 36.5 2 x 10 N/A -54 N/A 60.4 Mortar Per RA5 120 and Product Approval of Mortar Mfgr 20.6 TABLE 3C-1: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT - MF (FT-LBF) HIGH PROFILE TILES, MECHANICALLY ATTACHED SYSTEMS Tile Fastener Direct -Deck (min. 15/32" plywood) Direct -Deck (min.19/32" plywood) Battens Type # Size Shank Clip Nail One (1) lod Smooth or Screw N/A 5.1 6.8 2.8 Nail Two (2) 10d Smooth or Screw N/A 6.9 9.2 7.3 Nail One (1) 10d Smooth or Screw Field 23.1 23.1 19.0 Nail One (1) 10d Smooth or Screw Eave 29.3 29.3 24.0 "S", Nail Two (2) 10d Smooth or Screw Field 27.6 27.6 38.6 Bella High Galena- Spanish "S" Regal Nail Two (2) 10d Smooth or Screw Eave 38.1 38.1 41.8 or Nail Two (2) 10d Ring N/A 28.6 41.2 19.4 Nail' Two (2)' 10d' Ring' N/A 33.11 48.1' 50.91 Screw One (1) #8 N/A N/A 20.7 20.7 18.1 Screw Two (2) #8 N/A N/A 43.2 43.2 29.8 'Installation with a 4-inch tile headlap and fasteners located min. 2'/:-inch from head of tile. TABLE 3C-2; ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT- MF (FT-LBF) HIGH PROFILE TILES, MORTAR & ADHESIVE -SET SYSTEMS Tile Application Adhesive Size (inch) Weight (g) Mf (ft-Ibf) To Substrate To Tile To Substrate To Tile Bella High "5", Galena 'Spanish "S" or Regal Inter - Dependent TILE BOND" 1 x 6 1 x 10 -11 ^22 48.1 Touch'n Seal'" StormBond 1.25 x 30 0.75 x 8 -8.4 ^3.9 51.6 ICP Adhesives Polyset RTA-1; cross -bond two (2) -6" long oblong -10" across I head -12 each -15 36.2 ICP Adhesives Polyset AH-160 4 x 4 2 x 4 -16 ^ 8 30.1 t Independent , ICP Adhesives Polyset AH-160 2 x 7 N/A -30 N/A 48.5 2 x 10 N/A -'63 N/A 93.5. Mortar Per RA5120 and Product Approval of Mortar Mfgr 24.5 Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R3 Certificate of Authorization 0503 FL7804-R9 Revision 3: 04/18/2016 Page 8 of 9 Q'TRINITYIERD TABLE 3A-1: ATTACHMENT RESISTANCE EXPRESSED ASA MOMENT- MF (FT-LBF) FLAT PROFILE TILES, MECHANICALLY ATTACHED SYSTEMS Tile Fastener Direct -Deck (min.15/32" plywood) Direct -Deck (min.19/32" plywood) Battens e Type # Size Shank Clip p Nail One (1) 10d Smooth or Screw N/A 7.3 9.8 • 4.9 Nail Two (2) 130d Smooth or Screw N/A 14.0 18.8 7.4 Nail One (1) 110d Smooth or Screw Eave 19.0 19.0 22.1 Nail One (1) 10d Smooth or Screw Field 24.3 24.3 24.2 Bermuda Flat, Nail Two (2) lOd Smooth or Screw Eave 31.9 31.9 32.2 Plantation Flat or Nail Two (2) lOd Smooth or Screw Field 35.5 35.5 34.8 Horizon Nail Two (2) i3Od Ring N/A 30.9 38.1 17.2 Nail' Two (2)' 10d' Ring' N/A 50.3' 65.5' 48.3' Screw One (1) #8 N/A N/A 30.8 30.8 18.2 Screw Two (2) #8 N/A N/A 51.7 51.7 24.4 ' Installation with a 4-inch tile headlap and fasteners located min. 2%-inch from head of tile. TABLE 3A-2: ATTACHMENT IRESISTANCE EXPRESSED -AS A MOMENT- MF (FT-LBF) FLAT PROFILE TILES, ADHESIVE -SET SYSTEMS Tile Application 1 Adhesive Size (inch) Weight (g) Mf (ft-lbf) To Substrate To Tile To Substrate To Tile � Bermuda Flat, Plantation Flat or Horizon Inter - Dependent TILE BOND- I 1 x 6 1 x 6 -11 -11 40.6 Touch 'n Seal'" StormBond 1.25 x 10 1.25 x 8 -8.3 -10.2 73.2 ICP Adhesives Polyseti RTA-1; cross -bond . I -5" long oblong -4.5" across head -9 ^'S 51.8 I ICP Adhesives PolysetlAH-160 4 x 4 2 x 4 -16 -8 42.8 Independent ICP Adhesives Polyset �, H-160 2 x 7 N/A -30 N/A 50.9 2 x 10 N/A -45 N/A 91.9 TABLE 3B-1: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT- MF (FT-LBF) I LOW PROFILE TILES; MECHANICALLY ATTACHED SYSTEMS Tile Type # Size Estate "5" or Hacienda Nail One (1).2 10d Nail Two (2) 10d Nail One (1) 2 10d Nail one 30d Nail Two (2) 10d Nail Two (2) 10d Nail Two (2) 10d Nail' Two (2)' iod' Screw one #8 Screw Two (2) #8 ' Installation with a 4-inch tile headlap and 2 For one (1) fastener installations, utilize h Exterior Research and Design, I.I.C. Certificate of Authorization #9503 Direct -Deck (min.15/32" plywood) Direct -Deck (min.19/32" plywood) Shank Clip Smooth or Screw N/A 8.82 11.82 Smooth or Screw N/A 16.4 21.9 Smooth or Screw Eave 19.02 19.02 Smooth or Screw Field 24.3 2 24.3 2 Smooth or Screw Eave 31.9 31.9 Smooth or Screw Field 35.5 35.5 Ring N/A 27.8 37.4 Ring' N/A 43.0' 67.5' N/A N/A 25.82 25.82 N/A N/A 47.1 47.1 mers located min. 2Y.-inch from head of tile. hat is approximately 4%-Inch from the interlocking edge. Battens 4.1 2 7.1 22.12 24.2 2 32.2 34.8 28.8 22.9' 49.1 Evaluation Report E39310.11.11-1-R3 FL7804-R9 Revision 3: 04/18/2016 Page 7 of 9 TRINITY I ERD 7. LABELING: 7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. 1 and/or ENTEURR Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S" and/or H,. n o.n Labeling: Horizon flat, Hacienda, Regal 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Plant Profiles Okeechobee, FL Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S" Ft. Myers, FL Horizon Flat, Hacienda Deerfield Beach, FL Horizon Flat, Hacienda, Regal 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777 - END OF EVALUATION REPORT — Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R3 Certificate of Authorization #9503 FL7804-R9 Revision 3: 04/18/2016 Page 9 of 9