HomeMy WebLinkAboutEVALUATION REPORTTRlI�IITY I ER® EVALUATION REPORT ICP Adhesives and Sealants, Inc. 12505 NW 44th Street Coral Springs, FL 33065 EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT 13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report 02768.03.06-R7 FL6332-R7 Date of Issuance: 08/.08/2008 Revision 7: 06/16/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: ICP Adhesives Polyset® AH-160 LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nleminen, P.E, on 06/16/2016. This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC, d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRIM Y 1 ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roof Tile Adhesives s Compliance Statement: ICP Adhesives Polysetm AH-160, as produced by ICP Adhesives and Sealants, Inc., has demonstrated compliance with the Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is subject to the InstallationRequirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Sections Property Standard Year 1505.1 External Fire Classification ASTM E108 2007 1711.2.1 Wind SSTD 11 1997 3. REFERENCES: Entity Examination Reference Date ERD (TST 6049) SSTD 11 P39740.02.12 02/20/2012 ERD (TST 6049) SSTD 11 P39740.11.13-R1 01/02/2015 ICC-ES (EVL2396) 2012 IBC Compliance ESR-1709 12/01/2014 ITS (TST 1585) ASTM E108 101646522SAT-001_Rev.1 12/23/2014 Miami -Dade (CER 1592) HVHZ compliance 16-0315.01 04/07/2016 PRI (TST 5878) SSTD 11 ECM-001-02-01 09/21/2001 PRI (TST 5878) SSTD 11 PFI-006-02-01 05/09/2005 PRI (TST 5878) SSTD 11 PFI-006-02-02 05/09/2005 PRI (TST 5878) TAS 101 PFI-007-02-01 10/11/2005 PRI (TST 5878) SSTD 11 PFI-008-02-04 02/21/2006 PRI (TST 5878) SSTD 11 PFI-009-02-03 02/21/2006 PRI (TST 5878) SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) SSTD 11 PFPI-010-02-01 12/07/2006 PRI (TST 5878) SSTD 11 PFPI-011-02-01 12/07/2006 PRI (TST 5878) SSTD 11 PFPI-012-02-01 12/07/2006 PRI (TST 5878) SSTD 11 PFPI-013-02-01 12/07/2006 PRI (TST 5878) SSTD 11 PFPI-014-02-01 12/07/2006 PRI (TST 5878) TAS 101 ECM-003-02-01 06/13/2008 PRI (TST 5878) TAS 10,1 ECM-004-02-01 06/13/2008 PRI (TST 5878) TAS 101 ECM-005-02-01 06/13/2008 PRI (TST 5878) TA5 101 ECM-006-02-01 06/13/2008 PRI (TST 5878) TAS 101 ECM-007-02-01 06/13/2008 PRI (TST 5878) TAS 101 ECM-008-02-01 06/13/2008 UL LLC (QUA 9625) Quality Assurance Service Confirmation Exp. 06/05/2018 4. PRODUCT DESCRIPTION: I, 4.1 ICP Adhesives Polyset® AH-160 is a two -component expanding polyurethane roof the adhesive that is mixed and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. -The components are available in refillable tanks or disposable cylinders (ICP Adhesives ProPack® 30 & 100). + 5. LIMITATIONS: , 5.1 This is a building code evaluation. Neither Trinity I ERD nor+Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. i Exterior Research and Design, I.I.C. 11 Evaluation Report 02768.03.06-R7 Certificate of Authorization #9503 FL6332-117 4i Revision 7t 06/16/2016 ` I Page 2 of 9 J TRINITY I ERD 5.3 Concrete and clay tiles, having a current Florida Statewide Product Approval or approved on a local -level by the AHJ, adhered using ICP Adhesives Polyset® AH-160, maintain their respective roof fire classifications. Refer to FBC 1505.2, Exception 2. 5.4 ICP Adhesives Polyset® AH-160 can be used with flat, low and high profile tiles or any rigid, discontinuous roof assembly having a current Florida Statewide Product Approval or approved on a local -level by the AHJ. 5.5 Minimum underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide Product Approval or approved on a local -level by the AHJ for use with ICP Adhesives Polyset° AH-160. 5.6 Field tiles using ICP Adhesives Polyset® AH-160 are limited to projects having an Aerodynamic Uplift Moment (Ma), determined in accordance with FBC 1609.5.3 or Tables 2A and 2B of FRSA/TRI April 2012 (04-12), not greater than the following Allowable Overturning Moment values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 1 F.IELD•TILES:IN ICP ADHE51VEs'POLYSET®AH=160.. ALLOWABLE.OVERTURNING'MOMENT _PERFQRMANccDATA 210 MARGINOFSAFErY;-WEADYAPPLED FORINDEPENDEM 01NG&6 CDNTlW USPADDY) PIACEMFNr' • 4T0$MARGINOF, SAFE7YAlAFADYAPPIIE�'FOR'INiEflDEPFNDENT.(TWO PADDY�PIACEMENr ,f. ' Tile Adhesive Paddy Placement Allowable overturning Type Profile Moment (ft-lbf) Independent; Single Paddy, Medium (2x7-inch, -30 gram) 60 Clay Flat Independent; Single Paddy, Large (2x10-inch, —45 gram) 112 Concrete Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch at tile overlap) 54 Independent; Single Paddy, Medium (2x7-inch, "30 gram) 39 Clay Low/ Independent; Single Paddy, Large (2x10-inch, —54 gram) 67 Concrete te Medium Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at tile overlap) 58 Clay High Independent; Single Paddy, Large (WO -inch, -45 gram) 134 Independent; Independent; Single Paddy, Medium (2x7-inch, "30 gram) 65 Clay or High Independent; Single Paddy, Large (WO -inch, -63 gram) 109 Concrete Interdependent; Two Paddy (4x4-inch'on underlayment, 2x4-Inch at tile overlap) 40 Clay Barrel 2x10-inch x -35 gram for pans; 2 @ WO -inch x -17 gram for cap 147 Concrete Barrel 2x10-inch x -35 gram for pans; 2 @ WO -inch x "17 gram for cap 107 Clay Cap atop 2x Independent: Continuous Paddy (^34 gram/ft) 135 stringer Concrete Cap atop 2x Independent: Continuous Paddy (-34 gram/ft) 116 stringer Clay Cap atop 2x Interdependent: 105 stringer Head: One (1) #10 x 2%:" screw; Overlap: 1 x 6 inch (-10.5 gram) Concrete Cap atop 2x Interdependent: 76 stringer Head: One (1) #10 x 2%" screw; Overlap: 1 x 6 inch (-10.5 gram) 5.6.1 Data in Table 1 relates to installation over a '30/90' underlayment system, as detailed in the FRSA/TRI April 2012 (04-12). Alternate underlayment systems include those having a current Florida Statewide Product Approval and/or approved on a local -level by the AHJ specifically for use with ICP Adhesives Polyset° AH-160. 5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with ICP Adhesives Polyset® AH-160 shall be tested in accordance with SSTD 11 or TAS 101. For the interdependent two -paddy method, an additional 2-to-1 margin above that specified in SSTD 11 or TAS 101 shall be applied in determining the 'allowable overturning moment'. Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-R7 Certificate oJAuthoritation #9503 F1.6332-117 Revision 7: 06/16/2016 Page 3 of 9 ! TRINITY I ERD 5.7 Hip and ridge tiles using ICP AdhesiveslPolysetO AH-160 are limited to projects having hip/ridge design pressure requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. ! t HIP -&RIDGE TILES-IN;ICR ADHESIVES POLYSEi� AH-160 ALLOwABLELIPbFT RESISTANCE PERF0 MANCE:DATA { ' 2,To 1 MAR GIN OF SAFETY-ALREA6 APPLIEDFOR-INDEP£NDENTq (CON TIN UOIISPAD DY)PIgCEMENT 4 T0'1{MARGIN:OF. SAFETYALREADYAPPLIED FORJNTERDEPENDENT P.LACENIENT , l Allowable Tile Substrate Attachment Method Design Pressure (Psf) Clay 2x PT ridge board 1 Independent: Continuous Paddy (-34 gram/ft) 116 Concrete 2x PT ridge board I Independent: Continuous Paddy (— 34 gram/ft) 107 Clay 2x PT ridge board Interdependent: Head: One (1)' #10 x 2'/:" screw; 90 Overlap: 1 x 6 inch (-10.5 gram) Concrete 2x PT ridge board Interdependent: Head: One (1) #10 x 2%" screw; 56 i Overlap: 1 x 6 inch (-10.5 gram) Clay or Hip & Ridge Channel Metal (FL5374): Concrete galvanized only i Independent: Continuous Paddy p y (^ 34 gram/ft) 169 Clay or Trim Lock'" (FL5374): aluminum, � Concrete galvanized, Galvalume® or stainless steel Independent; Continuous Paddy p y ("'34 gram/ft) 173 Clay or Trim Lock'm Plus (FL537© ): aluminum, Concrete galvanized, Galva lume or stainless steel Independent: Continuous Paddy (� 34 gram/ft) 178 Clay Top Notch (FL8095) Independent: Continuous Paddy 32 gram/ft) 125 Concrete Top Notch (FL8095) Independent: Continuous Paddy 32 gram/ft) 146 6. INSTALLATION: 6.1 ICP Adhesives Polyset° AH-160 and the tile�roof assembly shall be installed in accordance with FRSA/TRI April 2012 (04-12) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the limitations outlined in Section 5, 6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04-12). Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. 6.3 Installation shall be performed�by applicators who hold a valid Qualified Applicator Card presented by ICP Adhesives and Sealants, Inc, 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Tomball, TX 9. QUALITY ASSURANCE ENTITY: UL LLC-QUA9625; (414) 248-6409; Karen.buchmannCcDus.ul.com Exterior Research and Design, I.I.C. Evaluation Report02768:03.06-R7 Certificate of Authorization N9503 FL6332-R7 Revision 7: 66/16/2016 Page 4 of 9 ".:,I� TRINITY i ER® 10. PADDY PLACEMENT DETAILS (FROM ICP ADHESIVES AND SEALANTS, INC. PUBLISHED LITERATURE): 10.1 Independent, Medium Paddy: Nail through plastic cement (when required) Underlayment U Ot- in.�►—fi ��2 in. Batt Optional ° Eave Course U ; 10 in. -_ Eave Closure Paddy (Beneath Tile) Flat/Low Profile Tile Nail through plastic cement (when required) �_- Paddy (Beneath Tile) 71n 2In. Battens optional loin. 21 f Eave Course- / Medium Profile Tile Nall through plastic <e ern (when required) Paddy (Beneath Tile) Underlayment n�7 2 in. Battens optional �'� Eave Course -.._ ,_� � � Fascia Wee hole r P 10 in.. tin. Eaveclosure Drip edge High Profile Tile "-- Eave Closure Fascia Exterior Research and Design, LLC. Evaluation Report 02768.03.06-R7 Certificate of Authorization #9503 FL6332-117 Revision 7: 06/16/2016 Page 5 of 9 L TRINITY I ER® 10,2 Independent. Larne Paddy: Nail through plastic cernent (when required) 1---.Paddy (BeneathTile) Underlayrn nt r 2 in.wide Battens optional 10 in ' Eave Closure Eave Course��l Fascia Flat/Low Profile Tile High Profile Tile Exterior Research and Design, LLC. Certificate of Authorization #9503 Medium Profile Tile Evaluation Report 02768.03.06-R7 FL6332-R7 Revision 7: 06/16/2016 Page 6 of 9 J' TRINIT i1ER® 10.3 Interdependent, Two Paddy: Nail through plastic cement Paddy (between tiles) (when required) Battens optional ° ° Paddy (under tile) (` Single paddy on top i- 4 x On. \ ^ /'��� Single paddy undertilSingle paddy on underlayment �2 x 4 in. `� ' 10in. �. Fascia 2 in. Eave Closure Flat/Low Profile Tile Nail through plastic cement Single paddy under the (when required) Paddy (between tiles) Battens /Paddy (under tile) optional f Sin 9 le add p Y •�- on top of tile\ ` \` �� �4x4in. x4 n. Single paddy on underlayment/_?•._ - 10 in. \ ,— Eave Closure Eave Course .�� Fascia Medium Profile Tile Nall through plastic cermem Single paddy under tile (when required) (/ Paddy (between tiles) Battens o Paddy optional (','' y loader tile) W Singlepaddy L r ,f on underlayment �4x4in. Single 2 x 4 in,�%' paddyon top of tile :•` , ,7 �ff'rj EaveCourse `_�� Fascia * weephole 10 in. ��? in• Eave closure Dripedge Je High Profile Tile Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-R7 Certificate of Authorization #9503 F1.6332-117 Revision 7: 06/16/2016 Page 7 of 9 I TRINITY1 ER® 10.4 Two Piece Barrel (Cap & Pan) Tile: I 1) Place enough adhesive to achieve 6S to 70 sq.In. Steep pitch applications In contact with the pan tile. (when required) 2) Turn covers upside down. Place,dhoslvo 112 in. to 1 Inch In from outside odpe of cover tile. Install cover tile. I Ensure 2010 25 sq. in. coolest area on eoch side of cover tile. i Underiayment t` Eave closure (motarshown) I Weephole Fascia Boardl� Remove top portion of the gave course ever tile. Abut to second course of panties. Ensure eave end opan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile 10.5 _,—ir" I r I it A brad or1C P Poly sr18A]1-Ina may lv applied alxn a the liekl '1 a aucek bipfridga ti1•s, n lvad of ICP Polysrl X;1H• 16U uta}' Wu sm,ace ou both sides of the Wptidge Ward of gahiwwd be sppbed down the center or the lifundge Load or guhvmmi uvtal limn, to Pic%Me fraint. �I i t I I I I Exterior Research and Design, I.I.C. Certificate of Authorization #9503 Evaluation Report02768.03.06-R7 FL6332-R7 Revision 7: 06/16/2016 Page 8 of 9 10.6 Hip and Ridse (interdependent placement): - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Certificate of Authorization #9503 `-J TRINITY1 ERD Evaluation Report 02768.03.06-R7 FL6332-R7 Revision 7: 06/16/2016 Page 9 of 9