HomeMy WebLinkAboutROBERT HOLLIDAY -FLOOR PLAN - 2402 NW SIXT STREET OCALA, 5407533j "
IIG" I 10avz"
3/
3
G'- 0" X G'-S'
S.G.D.
18"J—
32'- 0"
PIERS UNDER COLUMNS IN ADDITION To
PIERS AT G'-0" ON CENTER THIS 51DE OF ADD -A-ROOM TO BE CONNECTED IN ADDITION TO THErEQUIREtJENT6
PERMIT, THERE MAY BE ADDITIONAL PiL'
TO EXISTING SINGLE FAMILY DWELLING. 8 14' 5" X 9' - O" X 80" �"PPLICABLETOTHIS PROPERTY THAT
OPENING 24'- 1 1" 2 7'- G" MAY BE FOUND IN THE PUBLIC RECORDS OF
W. H . OPENING THIS COUNTY.
ACCESS
_ — — — — — — — — — — — — — — — 25" X 34" OPEN I NG — — % 1 TICE
3/4' X I " GANGLAM OR MICROLAM RIDGE BEAM
CONTINUOUS ON TRUSS
FAMILYROOM
2-30X 54
32_ 0"
21'-
3
JUNCTION BOX
MAY VARY IN — — — — — — — — — — — — — — — — — — --
LOCATION — W.P, I J�---- — — — — — — — — — — — — S 2 ---
I N
2
— �2 \�
NOTE:
ENERGY CODE COMPLIANCE SHALL BE BASED
ON THE ENTIRE BUILDING, INCLUDING ADDITION,
IN ACCORDANCE WITH SECTION 501.1 (h) OF
THE FLORIDA ENERGY EFFICIENCY CODE FOR
BUILDING CONSTRUCTION. IT SHALL BE THE
RESPONSIBILITY OF THE OWNER TO DEMONSTRATE
TO THE BUILDING DEPT. ENERGY COMPLIANCE
24
20"
14"
116"
14'
20"
24
2'-6" IG'-6" FROM END OF DUCT TO AIR 29'- G"
SUPPLY
3' G" 28 1/4"
"-�
13'• 6" 19% 0"
28'- 0"
3 6' Ti
GXIO GX 10
;+I
6X 10
5"X 15"X 27%0" CLASS I FIBERGLASS DUCT
BOARD 10" AIR SUPPLY DROPOUT
H.V. A.C. PLAN
3 2'- 0"
NOTE DUCT MAY BE RELOCATED IN FLOOR,
REGISTERS MAY VARY IN LOCATION
In
NOTE: - -n--.
IF THE ADD -A-ROOM MODULAR DOES NOT HAVE A NOT TO BE OCCUPIED
SWINGING SIDE HINGE TYPE DOOR, THEN THEAAPPROVAL
MAIN EGRESS DOOR MUST BE A SIDE SWINGING PFFORE
TYPE DOOR AND LOCATED IN EXISTING DWELLING. iv-HULDING DEPART ENT
THE MEANS OF EGRESS TO ROUTE FROM THE; r e'ENDiTIaNs
ADD -ON -ROOM TO THE MAIN EGRESS DOOR
MUST BE IN ACCORDANCE WITH THE LIMITATIONS
AND REQUIREMENTS OF CHAPTER II OF THE
STANDARD BUILDING CODE AND 15 SUBJECT TO 7
LOCAL JURISDICTION APPROVAL ��o /i �.
ST LUCIE Cc
BUILDING DIVISION
REVIEWED
FOR C L..I
FLOOR PLAN NOTE THIS FLOOR PLAN MAY BE BUILT
IN A FLIPPED CONFIGURATION
_t I' �; A"'D PERIL�I7'
BE KEP F ,� j(, s R
i- -CTIt� N
C
SYMBOLS
Wall Mount Ou tlet
Duplex Outlet
TV Outlet
J[]
Junction Box
Ceiling Outlet
5
Swi tc h
CI
Phone Jack
APPROVAL
I-4790 Plan No
Approved E,y KENNET-H A. GODFREY
nnodul�[,.Iq
8 i!dor;: Plans Examiner
C-:rtiticate NIO. 003
ELECTRICAL SCHEDULE
Circ
Description
Bkr Amp
Wire Ga
Volts
I
Gen Light
15
14
115
2
Gen Light
15
14
115
ELECTRICAL PLAN
NOTE: FEEDER WIRES IN JUNCTION BOX TO BE FIELD
CONNECTED TO POWER SOURCE FROM EXISTING
APPROVED STRUCTURE OR SEPARATE INDIVIDUAL
SOURCE PER LOCAL CODES
SWITCHES MAY BE RELOCATED (AS SHOWN)
BUT MUST COMPLY WITH N.E.C.
APPROVAL
CHARIOT EAGLE
Lwlifvv
.,%GENCY APPROVAL
0 C A L A ) FLORIDA
Hess prints comply with the
=-iorida Manufactured Building
Ac+ of 1979 Construction Codes
and ad.liere to the following
-riteria:
T I T L E
FLOOR PLAN , ELECT . , DUCT
MODEL
Const. Type _
10 3 2 — 1
occ uparicV _-K.
of t;'' S ----� -
;"Ly — I►5
REV DATE
REV DATE
DATE
SCALE
12 — 28 — 89
1 / 4 „ _ I . _
Pian h9 194.Z.? I1
0„
DRAWN BY
CHECKED BY
Aflow. Fc:or L-.ac. -moo.•,
Approval
Manuf. Gi_-�At2_IOT,�!LE
SPELL
SHEET I OF 2
DRAWING NO
HW
4
4
4
0
a
APPROVED TRUSS AT IG" O.C. DIRECTLY OVER
WALL STUDS OR TOP PLATE MUST BE DOUBLED
k'12" O.C. WHEN WALL STUDS ARE 12" O.C.)
235 lb. FIBERGLASS SHINGLES ON 2 LAYERS OF
15 lb FELT IF ROOF PITCH IS LESS THAN 4 12 ON
7/ IG" ORIENTED STRAND BOARD, RATED SHEATHING —�
EXPOSURE 1, 24/16
ALUMINUM DRIP EDGE CONT. (TYP)
1 1/2" X 30 GA. GALV.
STEEL STRAP AT IG"
O.C. MAX. (TYP)
SEE DRAWING R-3 ;f
2 X 4 OUTSIDE RAIL
CONT
OPTIONAL OVERHANG
(SEE DRAWING R-2 ) --
ALL WINDOWS SIZED TO
MEET REQUIRED GLAZE
AREA AND VENT
(AND EGRESS A5 REQ' D)
VINYL SIDING (TYP)
I X 2 CONT BELT RAIL
(TYPICAL) -
28" II
ELECTRICAL DADO WITH MAX.
WIRE PROTECTOR
2 X 4 BOTTOM PLATE CONT.
METAL BOTTOM PAN OR
SIMPLEX BOARD
MAIN "I" BEAM (TYP.)
8" X IG" X 16" CONC. FTG.
(TYP.) TO BE REINFORCED
PER LOCAL CODE REQUIREMENT
AND MUST BE BELOW FROST
LINE—
—
ATTIC NET VENTILATION REQUIREMENT OF 1/150tn OF ROOF AREA IS
ACCOMPLISHED BY SOFFIT VENTS AT EACH ENDWALL OVERHANG 7
12"
3. 3" R.P.
R-19 CEILING INSULATION (TYP)
1/2" MINERAL FIBERBOARD
SINGLE 2 X4SPF-02 TCP PLAT[, CONT TYP
�-2 - 2 X HEADER W/ 1/2' PLYWOOD
FILLER SIZED PER OPENING
1/8" X 3/4" PUTTY TAPE OR EQUIV.
�4 CONT AROUND ALL WINDOWS AND
DOOR PENETRATIONS
./ �2 X 4 WINDOW SILL
INTERIOR WALL FINISH
TO BE OF CLASS "C"
EXCEPT HALLWAYS TO
BE OF CLASS " B"
PUTTY TAPE , FOAM TAPE ) CAULKING
OR EQUIV. CONT SEAL AROUND ENTIRE
LENGTH AND WIDTH OF UNIT BETWEEN
130TTOM PLATE k FLOOR - TOP PLATE
AND CEILING BOARD AND SIDEWALLS
TO END WALL
PARQUET WOOD FLOORING CARPET OR
ROLL GOODS STANDARD FLOOR COVERING
3/4" PLYWOOD DECKING
18"
R-7 FLOOR INSULATION MIN
TYPICAL 34„
CLASS I FIBERGLASS MAX.
DUCT BOARD
o �
n
CROSSMEMBER AT 48" v
O.C. MAX. (TYP) ('12 MIN.
BELFROST
LINE
NOTE-
I,SEE DRAWING NO. FD-I FOR FOUNDATION DETAILS WITH OUTRIGGERS
AND CROSSMEMBERS @ 24"O.C. MAX,
2.SEE DRAWING NO. FD-2 FOR FOUNDATION DETAILS WITH OUTRIGGERS
AND CROSSMEMBERS Q 4B" O.0 MAX.
NOTE
TIRES AND AXLES OMITTED FOR CLARITY
AND SERVE FOR TRANSPORTATION PURPOSES ONLY.
m
NOTE:
ALL DESIGN AND CONSTRUCTION OF ATTACHMENT TO THE
EXISTING STRUCTURE IS BY OTHERS,ON SITE, SUBJECT TO
LOCAL APPROVAL. EXISTING STRUCTURE MUST BE CAPABLE
OR BE MADE CAPABLE OF RECEIVING HORIZONTAL WIND FORCE
IMPOSED ON THE ADD -A -ROOM.
------ALUMINUM DRIP EDGE CONT. (TYPICAL)
3/4" GANGLAM OR GLUE LAMINATED RIDGE BEAM CONT.
1 1/2" X 30 GA. GALV. STEEL STRAPS AT 16" O.C. MAX.
TYPICAL FOR OPEN SPANS SEE STRAP REQUIREMENTS
ON DRAWING NO. R-3
SINGLE 2 X 4 TOP PLATE CONT.
EXTERIOR FINISH TO BE OF VINYL SIDING WHEN
EXPOSED TO THE OUTSIDE AND/OR PANELING WHEN
EXPOSED TO THE INSIDE
'—EXT. WALL SHEATHING TO BE 3/6" MIN. EXPOSURE
I PLYWOOD OR INSULATIVE STRUCTURAL 13.0ARD
(SILVERLINING GRADE RED) NOTE: APPROVED VAPOR BARRIER ON
INSIDE WALL IS REQUIRED WHEN SILVERLINING IS USED
---R - 1 1 WALL INSULATION (TYP)
2 X 4 S.P.F. #2 STUDS e IG" 0. C'. (TYP)
2 X 4 BOTTOM PLATE CONT.
DOUBLE
2 X G FLOOR J015T (R� 2G" O.C. MAX. (TYP)-
ALL BUTT JOINTS SHALL BE LOCATED DIRECTLY OVER PIERS
OUTRIGGER @ 4S" O.C. (TYP)
PT. SHIM FOR LEVELING -(OR EQUIVALENT)
2" I 8"X IG" PT SILL PLATE (TY P )
6" X 8" X IG" CONC. MASONARY UNIT
TYPICAL (SEE FOUNDATION PLAN )
PERIMETER PIER NOT SHOWN —SEE FOUNDATION PLAN FD-2
FOR LOCATIONS AND SPECIFICATIONS
APPROVAL APPROVAL CHARIOT EAGLE
Ir OCALA ) FLORIDA
TITLE
CROSS- SECTION
MODEL
TYPICAL
REV BY
I REV DATE 10- 9-89 REV DATE
�15 DATE SCALE
0 05-31 -89 3/4" = 1'-0"
Ig47-o1 DRAWN BY CHECKED BY
SPELL
SHEET I OF 15 DRAWING ' NO
CS I
2'-0" FROM END
OF "I" BEAM MAX.
O -
THIS FOUNDATION PLAN MAY BE USED
WHEN OUTRIGGERS AND CROSSMEM— '
BEP,S ARE SPACED 2'-0" O.C. MAX
G' -0..
MAX. TYP.
NOTES
I)TIE DOWN STRAPS TO BE WRAPPED AROUND "I" BEAM AND
FASTENED TO STEEL, ANCHORS AT 4'-0" O.C. (ON BOTH "I"
BEAMS)
TIEDOWN STRAPS SHALL BE
1 1/4" X .035" GALV. STEEL
MIN, TYPE I, CLASS B, GRADE
I, OR AN EQUIVALENT STRAP
WITH AN ULTIMATE LOAD
CAPACITY OF 4725 Ib's.—�
10' DIA. X 18" DEEP e
CONCRETE COLLAR
---�- °
e
0
45°
"I" BEAM (TYP)
G'- 0
MAX. TYP.
WOOD SHIMS
-0
MAX. TYP.
"I" BEAM
2 X 8 X IG PT. WOOD SILL PL ATE
8" X 8" X 16" CONCRETE MASONARY
UNIT ON 8' X IG" X 24" CONC. FTG.
AT G'-O" ON CENTER
STEEL ANCHOR TO BE CERTIFIED AND TESTED
TO WITHSTAND 4750 lb. UPLIFT MIN.
OPTION "A" - DIRECT SOIL APPLICATION
G- O
MAX. TYP.
MAX. TYP.
—8"X8"XIG"
CONCRETE
MASON ARY
UNIT (TYP)
TIEDOWN STRAPS SHALL BE
1 1/4" X .035" GALV STEEL MIN,
TYPE I, CLASS B , GRADE I ,
OR AN EQUIVALENT STRAP 450
G'- 0" —1 2 0"
MAX. TYP.
"I" BEAM (TYP.)
8" X IG" X 24" CONC. FTG, (TYP) OR
MIN. 4" CONC. SLAB WITH 6"X G"
10/10 W.W.M. CONTINUOUS UNDER
BUILDING PER LOCAL CO DI
REQUIREMENTS. SLAB SHAL,- COVER
ALL AREA UNDER ADD -A -ROOM ,
AS A MINIMUM
WOOD SHIMS
2"X 8" X IG" PT WOOD SILL PLATE
WITH AN ULTIMATE LOAD
" X 8" X IG" CONCRETE MASONARY
CAPACITY OF 4725 lb's
UNIT ON EXISTING SLAB AT
6'- O" ON CENTER PER LOCAL
CODE REQUIREMENTS
= - - -
- _Q - '�-- 4" CONC. SLAB W/ G" X G" 10 / 10
- - -.d - -
-
W.W.M. (MIN.) WHEN MICS 2 ANCHO{A
BOLTS
ARE USED , OR WITH # 4 REBAR AT 12"
O.C.
5/8" X 3 1/2" PHI LLI PS ANCHOR BOLT
EACH WAY WHEN HN5630 ANCHOR BOLTS
ARE
WITH STANDARD ANCHOR HEAD (MODEL
USED.
NO. DTH -HEAD WITH HN5830 ANCHOR
BOLT) OR TIE DOWN ENGINEERING, INC..
4" MIN. FROM EDGE OF SLAB AND SUBJECT
PATIO SLAB ANCHOR W/EXPANSION BOLT
TO LOCAL CODE REQUIREMENTS
(MODEL NO. MICS 2)
NOTE:
TIE DOWNS TO BE WRAPPED AROUND
BOTH
"I" BEAMS AND FASTENED TO STEEL
ANCHORS
AT 4'-0" O.C. ON OUTSIDE AND 8'-0"
O.C.
INSI DE
OPTION 'rB"-EXISTING SLAB
APPLICATION
APPROVAL I APPROVAL
2
__L
CHARIOT EAGLE
OCALA , FLORIDA
TITLE
FOUNDATION PLAN
MODEL TYPICAL
0 10-31-89 12 -12- 8
as REV. DATE 10- 9-8 REV_ DATE
DATE SCALE
3/8" - 1'- 0"
DRAWN BY CHECKED BY
SPELL
SHEET 2 OF (5 DRAWING NO
FD-I
13
0 2
NOTE
140"
TYP.
G'-0" MAX. TYP- 6 - U MAX. TYP. 10 - v MAX. TYP. 6 -O MAX. TYP. G O MAX TYP . 6 O MAX . TYP .
2` 0"
8"- 0"' MAX. TYP.
8'- 0" MAX. TYP.
"I" BEAM -�
8'- 0" MAX. TYP.
8'- 0" MAX. TYP
THIS FOUNDATION DETAIL IS FOR MANUFACTURED BUILDINGS
WITH CHASSIS OUTRIGGERS AND CROSSMEMBERS AT 46" O.C. MAX,
SEE DRAWING NO FD I FOR FOUNDATION DETAILS WITH OUTRIGGERS
AND CRO55MEMBERS AT 24" O.C. MAX.
TIE DOWN STRAPS TO BE WRAPPED AROUND I BEAM AND
FASTENED TO STEEL ANCHORS AT 4'-0" O.C. (ON BOTH "I" BEAMS)
„I„ BEAM (TYP)
TIEDOWN STRAPS SHALL BE
1 1/4" X .035" GALV STEEL
MIN TYPE I , CLASS B, GRADE
I, OR AN EQUIVALENT STRAP
WITH AN ULTIMATE LOAD
CAPACITY OF 4725 Ib's
° p
10" DI A. X 18" DEEP a
4' CONCRETE COLLAR
0
n
WOOD SHIMS
2" X 6" X IG" PT. WOOD SILL PLATE
8"X 8"X 16" CONCRETE MASONARY
UNIT ON 8" X IG" X IG CONC. FTG.
AT 8'-0" ON CENTER PER LOCAL
CODE REQUIREMENTS
STEEL ANCHOR
TO
BE
CERTIFIED AND TESTED
/ TO WITHSTAND
4750
lb
UPLIFT MIN
OPTION "A" - DIRECT SOIL APPLICATION
"I" BEAM (TYP.)
2'- 0"
X 8 X 16 ON LO K N
B" X 16" X IG" CONC. FTG. TYP.
PERIMETER PIER FOUNDATION
PER LOCAL CODE REQUIREMENTS
�- 2'- 0" FROM E N D
OF I BEAM MAX. TYP.
6" X 8" X 16" CONC. BLOCK ON
8" X 16•' X 16" CONC- FTG. TYP.
INTERIOR PIER FOUNDATION
PER LOCAL CODE REQUIREMENTS
— OR —
8 X 8" X 16" CONC. BLOCK ON MIN
-i OF 4" CONC. SLAB WITH G" X G"
10/10 W.W.M- CONTINUOUS UNDER
BUILDING PER LOCAL CODE
REQUIREMENTS. SLAB SHALL COVER
ALL AREA UNDER ADD -A - ROOM , AS
----, A MININUM
WOOD SHIMS
TIEDOWN STRAPS SHALL BE `
1 1/4" X .035" GALV. STEEL MIN.
TYPE I CLASS B , GRADE I
2"X8" X 16"
PT. WOOD SILL PLATE
OR AN EOUIVALENT STRAP 450 450
WITH AN ULTIMATE LOAD
8" X 8" X 16"
CONCRETE MASONARY
CAPACITY OF 4725 Ib's
UNIT ON
EXISTING SLAB AT
8'-0" ON
CENTER PER LOCAL
CODE REQUIREMENTS
o - o
��-4" CONC. SLAB WITH 6"X G'" 10/ 10 W.W.M.
(MIN.) WHEN MICS 2 ANCHOR BOLTS ARE
5/8'" X 3 11 PH I LLI PS ANCHOR Bt>LT USED , OR WITH # 4 REBAR AT 12'" O.C. EACH
WITH STANDARD ANCHOR HEAD (MODEL WAY WHEN HN5830 ANCHOR BOLT ARE USED
NO. DTH -HEAD WITH HN5830 ANCHOR 4" MIN. FROM EDGE OF SLAB AND
BOLT) OR TIE DOWN ENGINEERING, INC.. SUBJECT TO LOCAL CODE REQUIREMENTS
PATIO SLAB ANCHOR W/ EXPANSION BOLT
MODEL NO. MICS2)
NOTE
TIE DOWNS TO BE WRAPPED AROUND BOTH
"I• BEAMS AND FASTENED TO STEEL ANCHORS
AT 4'-0" O.C. ON OUTSIDE AND 8'-0" O.C.
I N S I DE
OPTION "B"-EXISTING SLAB APPLICATION
APPROVAL
APPROVAL
CHARIOT EAGLE
OCALA , FLORI DA
TITLE
FOUNDATION PLAN
MODEL
TYPICAL
10-31-89 12-12-89
REV. DATE 10-9-89 REV. DATE
DATE SCALE
3/8', = 1'-0',
DRAWN BY CHECKED BY
SPELL
SHEET 3 OF (5 DRAWING NO
FD-2
i� .
. erc
ASPHALT OR FIBERGLASS SHINGLE
RIDGE CAP CONT.
APPROVED a o METHOD #1
SEALANT G„ X 30 GA. GALV. RIDGE CAP W1 I" GALV.
TYP, CONT / ROOFING NAILS 4" O.C. FULL LENGTH
(BOTH SIDES)
EXISTING ADD -A- ROOM METHOD # 2
APPROVED
STRUCTURE 5/IG" X 6" LAGS e 32" 0. C. STAGGERED IN
PREDRILLED HOLES
OPT. 5/IG" X 3" LAG THRU
CLIP INTO RIM JOIST
I
1/2'' NUT AND BOLT
WITH WASHER @ 8'- 0" O. C.
KI
OUTRIGGER
ADD-A - ROOM
EXISTING Ili
APPROVED
STRUCTURE
EXISTING
APPROVED
5TPUCTU RE
APPROVED
TRUSS AT
I G" 0. C. (OR 12" O.C.)
ADD -A- ROOM
NO. 8 X 3" SCREWS THRU 2 X INTO
BOTTOM CHORD OF TRUSS (BOTH SIDES)
ADD - A - ROOM
NO. 8 X 3" SCREWS e 12" O.C. STAGGERED
ANGLED THRU STUDS AT END OF CLEAR SPAN
OPENING ( FOR FASTENING TWO HALF TOGETHER)
APPROVAL
APPROVAL
CHARIOT EAGLE
.�Ilbi(o
OCALA FLORIDA
�
AGENCY APPROVAL`
;TITLE
-: 3ridprints ufactur with uaf�
SET—UP I N S TA L L AT I O N
\,.t of 1979 Constructich Codoo
D ETA I L S
-md adhere to the followint
��itse�aa
MODEL
TYPICAL
RAP
Coast. Typ
Occupancy �g
Ak 6wable No.
REV. BY
of Floors
R E V. D AT. E
REV. DATE
*ind V¢6chy
D AT E
0 6— 15 - 6 9
SCALE
�� 1 ��
1 1/2 1— 0
Fire Rj%t r of
EA. Walls
Pl in No. --FJ
DRAWN BY
CHECKED BY
A!1 7w. Flow Loom
LE
OVER
Ar)p*oval Date
�,f G L_
SPELL
TYP.)
INSTALL
SHEET 15 OF 15
DRAWING NO.
S U — I
f
STATE OF FLORIDA
DEPARTMENT OF COMMUNITY AFFAIRS
2 7 4 0 C E N T E R V I E W DRIVE • T A L L A H A S S E E, F L O R I D A 3 2 3 9 9
KA MARTINEZ
GOMM" November 13, 1989
THUat.aS G. PELHAM
Srirel�ry
Mr. Robert Holliday
Chariot Eagle, Inc.
2402 NW Sixth Street
Ocala, FL 32674
Re: Add -A -Room Approval based on the
85-S.C.'s with 1986 Revisions
Mfgrs. I.D. No.: CEI-163
Plan Approval No.: 89-163-AAR
This Approval Expires December 31, 1990
Dear Mr. Holliday:
I am pleased to inform you that the Department of
Community Affairs has granted Chariot Eagle approval to
manufacture Add -A -Rooms for installation throughout the State of
Florida. This approval is granted pursuant to inspection of
your submitted plans which were found by this Department and your
inspection/plans review agency to be in compliance with the
applicable codes.
Provisions for resistance to uplift and overturning are
approved so long as the Add -A -Rooms is tied down on an adequate
foundation, in accordance with the approved plans and
specifications.
A copy of this letter must be attached to the approved plans
when making application for local building permits.
Sinc rely,
i
wrence H.' Jordan
Planning Manager
Manufactured Buildings Program
LHJ/jf
cc: HWC
EMERGENCY MANAGEMENT • HOUSING AND COMMUNITYIDEVELOPMENT • RESOURCE PLANNING AND MANAGEMENT
STATE OF FLORIDA
DEPARTMENT OF COMMUNITY AFFAIRS
2 7 4 0 C E N T E R V I E W DRIVE T A L L A H A S S E E, F L O R I D A 3 2 3 9 9
BOB MARTINEZ THOMAS G. PELHAM
Governor August 31, 1989 Secretary
Mr. Robert Holliday
Chariot Eagle, Inc.
2402 NW.Sixth Street
Ocala, FL 32674
Re: Add -A -Room Approval based on the
85-S.C.'s with 1986 Revisions
Mfgrs. I.D. No.: CEI-163
Plan Approval No.: 89-163-AAR
This Approval Expires December 31, 1990
Dear Mr. Holliday:
I am pleased to inform you that the Department of,
Community Affairs has granted Chariot Eagle approval to
manufacture Add -A -Rooms for installation throughout the State of
Florida except the Florida Keys. This approval is granted
pursuant to inspection of your submitted plans which were found
by this Department and your inspection/plans review agency to be
incompliance with the applicable codes.
Provisions for resistance to uplift and overturning are
approved so long as the .Add -A -Rooms is tied down on an adequate
foundation, in accordance with the approved plans and
specifications:.
A copy of this letter must be attached to the approved plans
when making application for local building permits.
Sincerely,
Lawrence H. `Jordan
Planning Manager
Manufactured Buildings Program
LHJ/jf
cc: HWC
EMERGENCY MANAGEMENT 9 HOUSING AND COMMUNITY DEVELOPMENT • RESOURCE PLANNING AND MANAGEMENT
•. : s
awe ENGINEERING • INSPECTIONS
CERTIFICATIONS * TESTING
V
CERTIFICATION
REPORT NO.:
MANUFACTURER:
1947-01
Chariot Eagle, Inc.
2402 N.W. 6th St.
Ocala, FL 32675
DATE:
8/17/89
HILBORN, WERNER, CARTER & ASSOCIATES, INC. hereby certifies
that it has examined the documents included in and referenced
in this report and that manufactured structures built in
accordance with this report comply with the applicable sections
of the following Standards:
-Florida Manufactured Building Rules and Regulations
-Florida Accessibility Codes & Standards, Part V
-Life Safety Code, 1985 Edition
-National Electric Code, 1984 Edition
-Standard Building, Plumbing, Mechanical, & Gas Codes
1985 Editions with 1986 Revisions
SIGNED BY: DATE:
Manuel Cordero
PROJECT ENGINEER
8/17/89
for HILBORN, WERNER, CARTER & ASSOCIATES, INC.
_
Kenneth A. Godfr P. .
VICE PRESIDENT AUG SO 1989
DIRECTOR OF MODULAR DEPARTMENT
HILBORN, WERNER, CARTER AND ASSOCIATES, INC.
1627 SOUTH MYRTLE AVENUE CLEARWATER. FLORIDA 34816
(813) 584.8151
.y
o
.
P
�
r•
S L1MMA R.Y
The Legislature, by enacting Chapter 71-172, La�•rs
of Florida, has preempted local authorities from
regulating the manufacture or construction of
factory -built housing units, preserving only to
local units of government the authority i.o control
• the on -site installation - or placement of the
factory built housing units.on a parcel of land.
L0=1 governments have the authority to promulgate
land use and zoning "requirei*ents, site development,
,
subdivision control,. on -site installation require-
ments and aesthetic requirements. Hawever, such -
requirements which relate to transportation, eree- -
ti on and use shall be uniformly applied and
enforced without distinction as to whether such
factory -built housing is manufactured or built in
a conventional manner, and must not discriminate
against factory-bu-ilt housing.
Sincerely, j
�61 71
Robert L. Shevin r
Attorney General
Prepared bt. 4 .•
!Q, I rA
Pa / 1 ti . 'i.,- mbcrt
Assistant Attorney General '
Ph
FOR OFFICE USE ONLY
SPECIAL APPROVALS
,i
REQUIRED DATE RECEIVED
VEGETATION
QNVIRONMENTAL
✓
PLANNING/SITE PLAN
CODE ENFORCEMENT
USA
TAZ
WATER SUPPLIER
SEWER SUPPLIER
DER CERTIFICATION
FL DNR (CCCL)'
_
FL DOT
SLC DRIVEWAY PER
SLC STORMWATER PER
MANGROVE' ALT
SEA TURTLE PROT
REQUIRED FEES
PR#
NOT REQUIRED
L---
i
Y-
BP VALUE $
PLANS EXAMINING FEE l $ RADON FEE : .
ROAD IMPACT FEE $ \ Y�
ROAD IMPACT DISTRICT- ROAD IMPACT ZONE
ROAD IMPACT CREDIT: YES}: NO:
SCHOOL IMPACT FEE $ ` DATE PAID: CHK#.
SCHOOL IMPACT CREDIT:• YES: NO:
SCHOOL BOARD APPROVED EXEMPTION:" YES: NO:
ALTERNATIVE DEV. FEE $ ( DATE PAID:
ALT. DEV. FEE ZONE:
SUB PERMITS
REQUIRED NOT REQUIRED
GAS
AIR CONDITIONING --
ELECTRIC
PLUMBING
SCREEN ENCL/FENCE:,/�
ZONING CHECKS
BBL LOT COVERAGE �� EASEMENT
CHK#
t
L SPLITS
tlWTE p-� V(-C*A bP(
}I�LR(21CAIIf� S'rapW(a&- To
P►PP260eb Me-r-td�S
iSY Lo cA L a S-M. T9 R-s LNQ I E S
LAW i
ego
We
kle
V ICH-�D L: N VILJ
L
PP k
oc-v J�y I