Loading...
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method I Project Name: ROBERT DOLLAR ADDITION Builder Name: Street: 6703 ONECO WAY Permit Office: City,State,Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: _Deisign Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing Addition 9. Wall Types(242.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame-Wood, Exterior R=13.0 242.67 ftZ �umber b. N/A R= ft2 3. of units,if multiple family 1 c.N/A R= ftZ 4. Number of Bedrooms(Bedrms In Addition) 0(1) d. N/A R= ftz 1 10.CeilingTypes 250.0 s Insulation Area N0 5. Is this a worst case? yp ( sqft.) a. Under Attic(Vented) R=19.0 250.00 ftZ 6. Conditioned floor area above grade(ftZ) 250 b.N/A R= ftZ Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ 1 11. Ducts R ftZ 7. Windows(12.0 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Main 6 25 a! U-Factor: Sgl, U=0.70 12.00 ftZ SHGC: SHGC=0.35 b'. U-Factor: N/A ftZ 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 42.0 SEER:14.00 ci U-Factor: N/A ftZ SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a.Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.350 14.Hot water systems-None required a. Cap: N/A 8. Floor Types (250.0 sqft.) Insulation Area bSlab-On-Grade Edge Insulation R=0.0 250.00 ftZ b. Conservation features EF:0.000 .N/A R= ftZ .N/A R= ftZ 15.Credits CF,Pstat Glass/Floor Area: 0.048 Total Proposed Modified Loads: 8.96 PASS Total Baseline Loads: 9.05 i i I hereby certify that the plans and specifications covered by Review of the plans and 1TKE STa?, this calculation are in compliance with the Florida Energy specifications covered by this ;.' Code. calculation indicates compliance y'��,,, '�� _ .��`vc+ with the Florida Energy Code. � +++Rr ��" �.•,.• . « � PREPAR BY: !-� Before construction is completed r .� DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. wit h the Florida Energy Code. CpD WE OWNER/AGE T: A , ,% 0 - BUILDING OFFICIAL: DATE: oy i® DATE: I - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -CI ompliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). i 11/20/2018 9:36 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R4U0-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT FTB'iuilding le: ROBERT DOLLAR ADDITIO Bedrooms: 0 Address Type: Street Address Type: User Conditioned Area: 250 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 6703 ONECO WAY Permit Office: Cross Ventilation: County: St. Lucie ` Jurisdiction: Whole House Fan: City,State,Zip: FT.PIERCE, Family Type: Single-family FL, New/Existing: Addition Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low I BLOCKS Number Name Area Volume 1 Block1 250 2000 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 250 2000 No 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 60 ft 0 250 ft2 _--- 0 0 1 I ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 271 ft2 0 ft2 Light 0.5 No 0.9 No 0 22.6 I ATTIC I # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 250 ft2 N N I CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 19 Blown 250 ft2 0.11 Wood I 11/20/2018 9:36 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4 i FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below we Et In Ft In Area RA/ahle Eraction AhSor rwe% 1 S Exterior Frame-Wood Main 13 18 4 8 0 146.7 ft2 0 0.25 0.4 0 2 E Exterior Frame-Wood Main 13 12 0 8 0 96.0 ft2 0 0.25 0.4 0 DOORS Y # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated Main None .28 2 8 6 8 17.8 ft2 I WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 2 Metal Single(Tinted) Yes 0.7 0.35 N 12.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None I INFILTRATION I # j Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 233.3 12.81 24.09 .2578 7 i HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/Supplemen None COP:1 34 kBtu/hr 1 sys#1 i COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Supplemental for None SEER:14 42 kBtu/hr 1260 cfm 0.85 1 sys#1 I SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF ft2 I DUCTS ---Supply--- ----Return— Air CFM 25 CFM25 HVAC# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 25 ft2 Attic 10 ft2 Default Leakage Main (Default) (Default) 1 1 i 11/20/2018 9:36 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Pi ogramable Thermostat:Y Ceiling Fans: Cool in an Feb Mar A r Ma ri Jun rl Jul ri Aug Se [ ]Oct Nov Dec Heating lX�Jan Feb x Mar f Apr f May Jun Jul Au Sep [ ]Oct XNov Dec 'Ventin [ Jan Feb X Mar [X A r [ Ma Jun Jul Aug Se [X]Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours ,,Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz Oft 0.3 Main Name: Signature:�hftbr_ Rating Compant: Date: I I 1;1/20/2018 9:36 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: ROBERT DOLLAR ADDITION Builder Name: Street: 6703 ONECO WAY Permit Office: City,State,Zip: FT. PIERCE, FL, Permit Number: Y U Owner: Jurisdiction: 2 Design Location: FL,Fort Pierce U (COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA eneral A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,penetrations Duct shafts, utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spat as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind pjp4na and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication I xterior walls boxes or air-sealed boxes shall be installed. VAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire spr plil a! In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 1I/20/2018 9:36 AM EnergyGaugeO USA FBC 6th Edition(2017)Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. i r 1. New home or, addition 1. Addition 12. Ducts, location&insulation level a) Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/Attic 3. No. of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 0 13. Cooling system: Capacity 42.0 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq.ft.) 6. 250 d) Room unit/PTAC EER e) Other 14.0 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.700 b) Solar Heat Gain Coefficient(SHGC) 7b. 0.350 14. Heating system: Capacity 34.0 c)Area 7c. 12.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised (R-value) 9b. 15.Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b)Gas fired, natural gas EF 10.Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. 13.0 e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. f) Heat recovery unit HeatRec% B.Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 2. Masonry(Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11a. 19.0 b) Cross ventilation No b) Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes I *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 6703 ONECO WAY City/FL Zip: FT. PIERCE, FL 1 i1/20/2018 9:36:47 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 I Job: -F - wrightsoft, Project Summary By: Entire House y: QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM i Prooect Information g For. ROBERT DOLLARADDITION 6703 ONECO WAY FT.PIERCE,FL Notes: ® - •n' '.14ormation Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative Humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20835 Btuh Structure 21058 Btuh Ducts 5393 Btuh Ducts 7477 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 26228 Btuh Use manufacturer's data n Rate/swingg multipplier 0.95 Infiltration Equipmentsensibleload 27108 Btuh Method Simplified Construction quality Avera Latent Cooling Equipment Load Sizing ge Fireplaces 0 Structure 2342 Btuh Ducts 2193 Btuh Central vent(0 cfm) 0 Btuh Heatingg Coolingg (none) Area(ftz) 1550 1550 Equipment latent load 4535 Btuh Volume(it') 13950 13950 Airchangges/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 31643 Btuh Equiv AVF(cfrn) 88 47 Req.total capacity at 0.70 SHR 3.2 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade 14 SEER AC Model Cond CA14NA0420000A0 AHRI ref Coil FB4CNP042L AHRI ref 9194235 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating Input 6.4 kW Sensible cooling 27300 Btuh Heating output 21953 Btuh Latentcooling 11700 Btuh Temperature rise 50 OF Total cooling 39000 Btuh Actual airflow 400 cfm Actual airflow 1300 cfm Airflowfactor 0.015 cfm/Btuh Airflowfactor 0.046 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -r+— wrroghtsoft` 2018-Nov-2009:47:21 w,,.••o.. ,..., . w, Right-Sdte®Universal 2018 18.0.16 RSU08101 Page 1 CKUoaanentss\WrightsoftHVAC\DOLLAR,ROBERT.rup Calc=MJ8 Frorf Door faces:NE i ® Duct stem Summary Job: wrs���soft Date: Entire douse By: QUICK CALLS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772-466-6799 Email:QUICKCALCS@,AOL.COM y • • • For: ROBERT DOLLARADDITION 6703 ONECO WAY FT.PIERCE,FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.080 in/100ft 0.080 in/100ft Actual airflow 400 cfm 1300 cfiTi Total effective length(TEL) 77 ft Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (Cfm) (cfm) FR (in) (in) Mat Ln(ft) Ln(ft) Trunk EXISITNG HOUSE-E C 23803 327 1084 0.080 19.0 OX 0 MFx 0 0 NEWBEDROOM2 c 2366 36 108 0.080 8.0 Ox0 VIFx 6.4 70.0 NEWBEDROOM2-A c 2366 36 108 0.080 8.0 OXO VIFX 7.1 70.0 Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Mat Trunk rb1 Ox 0 400 1300 0 0 0 0 Ox 0 MFx Boldlrtalic values have been manually overridden wrightsoft, 2018-Nov-20 09:47:21 Right Suite®Universal2018 18.0.16 RSU08101 Page 1 kca ...CK\Doaments\WrightsoftHVAC\DOLLAR,ROBERT.rup Calc=MJ8 Frord Door toes:NE